• 제목/요약/키워드: similar materials

검색결과 4,776건 처리시간 0.314초

Impact of Additional Preoperative Computed Tomography Imaging on Staging, Surgery, and Postsurgical Survival in Patients With Papillary Thyroid Carcinoma

  • So Yeong Jeong;Sae Rom Chung;Jung Hwan Baek;Young Jun Choi;Sehee Kim;Tae-Yon Sung;Dong Eun Song;Tae Yong Kim;Jeong Hyun Lee
    • Korean Journal of Radiology
    • /
    • 제24권12호
    • /
    • pp.1284-1292
    • /
    • 2023
  • Objective: We investigated the impacts of computed tomography (CT) added to ultrasound (US) for preoperative evaluation of patients with papillary thyroid carcinoma (PTC) on staging, surgical extent, and postsurgical survival. Materials and Methods: Consecutive patients who underwent surgery for PTC between January 2015 and December 2015 were retrospectively identified. Of them, 584 had undergone preoperative additional thyroid CT imaging (CT + US group), and 859 had not (US group). Inverse probability of treatment weighting (IPTW) and propensity score matching (PSM) were used to adjust for 14 variables and balance the two groups. Changes in nodal staging and surgical extent caused by CT were recorded. The recurrence-free survival and distant metastasis-free survival after surgery were compared between the two groups. Results: In the CT + US group, discordant nodal staging results between CT and US were observed in 94 of 584 patients (16.1%). Of them, CT accurately diagnosed nodal staging in 54 patients (57.4%), while the US provided incorrect nodal staging. Ten patients (1.7%) had a change in the extent of surgery based on CT findings. Postsurgical recurrence developed in 3.6% (31 of 859) of the CT + US group and 2.9% (17 of 584) of the US group during the median follow-up of 59 months. After adjustment using IPTW (580 vs. 861 patients), the CT + US group showed significantly higher recurrence-free survival rates than the US group (hazard ratio [HR], 0.52 [95% confidence interval {CI}, 0.29-0.96]; P = 0.037). PSM analysis (535 patients in each group) showed similar HR without statistical significance (HR, 0.60 [95% CI, 0.31-1.17]; P = 0.134). For distant metastasis-free survival, HRs after IPTW and PSM were 0.75 (95% CI, 0.17-3.36; P = 0.71) and 0.87 (95% CI, 0.20-3.80; P = 0.851), respectively. Conclusion: The addition of CT imaging for preoperative evaluation changed nodal staging and surgical extent and might improve recurrence-free survival in patients with PTC.

Is the Mixed Use of Magnetic Resonance Enterography and Computed Tomography Enterography Adequate for Routine Periodic Follow-Up of Bowel Inflammation in Patients with Crohn's Disease?

  • Jiyeon Ha;Seong Ho Park;Jung Hee Son;Ji Hun Kang;Byong Duk Ye;So Hyun Park;Bohyun Kim;Sang Hyun Choi;Sang Hyoung Park;Suk-Kyun Yang
    • Korean Journal of Radiology
    • /
    • 제23권1호
    • /
    • pp.30-41
    • /
    • 2022
  • Objective: Computed tomography enterography (CTE) and magnetic resonance enterography (MRE) are considered substitutes for each other for evaluating Crohn's disease (CD). However, the adequacy of mixing them for routine periodic follow-up for CD has not been established. This study aimed to compare MRE alone with the mixed use of CTE and MRE for the periodic follow-up of small bowel inflammation in patients with CD. Materials and Methods: We retrospectively compared two non-randomized groups, each comprising 96 patients with CD. One group underwent CTE and MRE (MRE followed by CTE or vice versa) for the follow-up of CD (interval, 13-27 months [median, 22 months]), and the other group underwent MRE alone (interval, 15-26 months [median, 21 months]). However, these two groups were similar in clinical characteristics. Three independent readers from three different institutions determined whether inflammation had decreased, remained unchanged, or increased within the entire small bowel and the terminal ileum based on sequential enterography of the patients after appropriate blinding. We compared the two groups for inter-reader agreement and accuracy (terminal ileum only) using endoscopy as the reference standard for enterographic interpretation. Results: The inter-reader agreement was greater in the MRE alone group for the entire small bowel (intraclass correlation coefficient [ICC]: 0.683 vs. 0.473; p = 0.005) and the terminal ileum (ICC: 0.656 vs. 0.490; p = 0.030). The interpretation accuracy was higher in the MRE alone group without statistical significance (70.9%-74.5% vs. 57.9%-64.9% in individual readers; adjusted odds ratio = 3.21; p = 0.077). Conclusion: The mixed use of CTE and MRE was inferior to MRE alone in terms of inter-reader reliability and could probably be less accurate than MRE alone for routine monitoring of small bowel inflammation in patients with CD. Therefore, the consistent use of MRE is favored for this purpose.

Direction of Tissue Contraction after Microwave Ablation: A Comparative Experimental Study in Ex Vivo Bovine Liver

  • Junhyok Lee;Hyunchul Rhim;Min Woo Lee;Tae Wook Kang;Kyoung Doo Song;Jeong Kyong Lee
    • Korean Journal of Radiology
    • /
    • 제23권1호
    • /
    • pp.42-51
    • /
    • 2022
  • Objective: This study aimed to investigate the direction of tissue contraction after microwave ablation in ex vivo bovine liver models. Materials and Methods: Ablation procedures were conducted in a total of 90 sites in ex vivo bovine liver models, including the surface (n = 60) and parenchyma (n = 30), to examine the direction of contraction of the tissue in the peripheral and central regions from the microwave antenna. Three commercially available 2.45-GHz microwave systems (Emprint, Neuwave, and Surblate) were used. For surface ablation, the lengths of two overlapped square markers were measured after 2.5- and 5-minutes ablations (n = 10 ablations for each system for each ablation time). For parenchyma ablation, seven predetermined distances between the markers were measured on the cutting plane after 5- and 10-minutes ablations (n = 5 ablations for each system for each ablation time). The contraction in the radial and longitudinal directions and the sphericity index (SI) of the ablation zones were compared between the three systems using analysis of variance. Results: In the surface ablation experiment, the mean longitudinal contraction ratio and SI from a 5-minutes ablation using the Emprint, Neuwave, and Surblate systems were 28.92% and 1.04, 20.10% and 0.53, and 24.90% and 0.45, respectively (p < 0.001). A positive correlation between longitudinal contraction and SI was noted, and a similar radial contraction was observed. In the parenchyma ablation experiment, the mean longitudinal contraction ratio and SI from a 10-minutes ablation using the three pieces of equipment were 38.60% and 1.06, 32.45% and 0.61, and 28.50% and 0.50, respectively (p < 0.001). There was a significant difference in the longitudinal contraction properties, whereas there was no significant difference in the radial contraction properties. Conclusion: The degree of longitudinal contraction showed significant differences depending on the microwave ablation equipment, which may affect the SI of the ablation zone.

Feasibility of Free-Breathing, Non-ECG-Gated, Black-Blood Cine Magnetic Resonance Images With Multitasking in Measuring Left Ventricular Function Indices

  • Pengfei Peng;Xun Yue;Lu Tang;Xi Wu;Qiao Deng;Tao Wu;Lei Cai;Qi Liu;Jian Xu;Xiaoqi Huang;Yucheng Chen;Kaiyue Diao;Jiayu Sun
    • Korean Journal of Radiology
    • /
    • 제24권12호
    • /
    • pp.1221-1231
    • /
    • 2023
  • Objective: To clinically validate the feasibility and accuracy of cine images acquired through the multitasking method, with no electrocardiogram gating and free-breathing, in measuring left ventricular (LV) function indices by comparing them with those acquired through the balanced steady-state free precession (bSSFP) method, with multiple breath-holds and electrocardiogram gating. Materials and Methods: Forty-three healthy volunteers (female:male, 30:13; mean age, 23.1 ± 2.3 years) and 36 patients requiring an assessment of LV function for various clinical indications (female:male, 22:14; 57.8 ± 11.3 years) were enrolled in this prospective study. Each participant underwent cardiac magnetic resonance imaging (MRI) using the multiple breath-hold bSSFP method and free-breathing multitasking method. LV function parameters were measured for both MRI methods. Image quality was assessed through subjective image quality scores (1 to 5) and calculation of the contrast-to-noise ratio (CNR) between the myocardium and blood pool. Differences between the two MRI methods were analyzed using the Bland-Altman plot, paired t-test, or Wilcoxon signed-rank test, as appropriate. Results: LV ejection fraction (LVEF) was not significantly different between the two MRI methods (P = 0.222 in healthy volunteers and P = 0.343 in patients). LV end-diastolic mass was slightly overestimated with multitasking in both healthy volunteers (multitasking vs. bSSFP, 60.5 ± 10.7 g vs. 58.0 ± 10.4 g, respectively; P < 0.001) and patients (69.4 ± 18.1 g vs. 66.8 ± 18.0 g, respectively; P = 0.003). Acceptable and comparable image quality was achieved for both MRI methods (multitasking vs. bSSFP, 4.5 ± 0.7 vs. 4.6 ± 0.6, respectively; P = 0.203). The CNR between the myocardium and blood pool showed no significant differences between the two MRI methods (18.89 ± 6.65 vs. 18.19 ± 5.83, respectively; P = 0.480). Conclusion: Multitasking-derived cine images obtained without electrocardiogram gating and breath-holding achieved similar image quality and accurate quantification of LVEF in healthy volunteers and patients.

Improvement in Image Quality and Visibility of Coronary Arteries, Stents, and Valve Structures on CT Angiography by Deep Learning Reconstruction

  • Chuluunbaatar Otgonbaatar;Jae-Kyun Ryu;Jaemin Shin;Ji Young Woo;Jung Wook Seo;Hackjoon Shim;Dae Hyun Hwang
    • Korean Journal of Radiology
    • /
    • 제23권11호
    • /
    • pp.1044-1054
    • /
    • 2022
  • Objective: This study aimed to investigate whether a deep learning reconstruction (DLR) method improves the image quality, stent evaluation, and visibility of the valve apparatus in coronary computed tomography angiography (CCTA) when compared with filtered back projection (FBP) and hybrid iterative reconstruction (IR) methods. Materials and Methods: CCTA images of 51 patients (mean age ± standard deviation [SD], 63.9 ± 9.8 years, 36 male) who underwent examination at a single institution were reconstructed using DLR, FBP, and hybrid IR methods and reviewed. CT attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and stent evaluation, including 10%-90% edge rise slope (ERS) and 10%-90% edge rise distance (ERD), were measured. Quantitative data are summarized as the mean ± SD. The subjective visual scores (1 for worst -5 for best) of the images were obtained for the following: overall image quality, image noise, and appearance of stent, vessel, and aortic and tricuspid valve apparatus (annulus, leaflets, papillary muscles, and chordae tendineae). These parameters were compared between the DLR, FBP, and hybrid IR methods. Results: DLR provided higher Hounsfield unit (HU) values in the aorta and similar attenuation in the fat and muscle compared with FBP and hybrid IR. The image noise in HU was significantly lower in DLR (12.6 ± 2.2) than in hybrid IR (24.2 ± 3.0) and FBP (54.2 ± 9.5) (p < 0.001). The SNR and CNR were significantly higher in the DLR group than in the FBP and hybrid IR groups (p < 0.001). In the coronary stent, the mean value of ERS was significantly higher in DLR (1260.4 ± 242.5 HU/mm) than that of FBP (801.9 ± 170.7 HU/mm) and hybrid IR (641.9 ± 112.0 HU/mm). The mean value of ERD was measured as 0.8 ± 0.1 mm for DLR while it was 1.1 ± 0.2 mm for FBP and 1.1 ± 0.2 mm for hybrid IR. The subjective visual scores were higher in the DLR than in the images reconstructed with FBP and hybrid IR. Conclusion: DLR reconstruction provided better images than FBP and hybrid IR reconstruction.

Prediction of Pulmonary Function in Patients with Chronic Obstructive Pulmonary Disease: Correlation with Quantitative CT Parameters

  • Hyun Jung Koo;Sang Min Lee;Joon Beom Seo;Sang Min Lee;Namkug Kim;Sang Young Oh;Jae Seung Lee;Yeon-Mok Oh
    • Korean Journal of Radiology
    • /
    • 제20권4호
    • /
    • pp.683-692
    • /
    • 2019
  • Objective: We aimed to evaluate correlations between computed tomography (CT) parameters and pulmonary function test (PFT) parameters according to disease severity in patients with chronic obstructive pulmonary disease (COPD), and to determine whether CT parameters can be used to predict PFT indices. Materials and Methods: A total of 370 patients with COPD were grouped based on disease severity according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD) I-IV criteria. Emphysema index (EI), air-trapping index, and airway parameters such as the square root of wall area of a hypothetical airway with an internal perimeter of 10 mm (Pi10) were measured using automatic segmentation software. Clinical characteristics including PFT results and quantitative CT parameters according to GOLD criteria were compared using ANOVA. The correlations between CT parameters and PFT indices, including the ratio of forced expiratory volume in one second to forced vital capacity (FEV1/FVC) and FEV1, were assessed. To evaluate whether CT parameters can be used to predict PFT indices, multiple linear regression analyses were performed for all patients, Group 1 (GOLD I and II), and Group 2 (GOLD III and IV). Results: Pulmonary function deteriorated with increase in disease severity according to the GOLD criteria (p < 0.001). Parenchymal attenuation parameters were significantly worse in patients with higher GOLD stages (P < 0.001), and Pi10 was highest for patients with GOLD III (4.41 ± 0.94 mm). Airway parameters were nonlinearly correlated with PFT results, and Pi10 demonstrated mild correlation with FEV1/FVC in patients with GOLD II and III (r = 0.16, p = 0.06 and r = 0.21, p = 0.04, respectively). Parenchymal attenuation parameters, airway parameters, EI, and Pi10 were identified as predictors of FEV1/FVC for the entire study sample and for Group 1 (R2 = 0.38 and 0.22, respectively; p < 0.001). However, only parenchymal attenuation parameter, EI, was identified as a predictor of FEV1/FVC for Group 2 (R2 = 0.37, p < 0.001). Similar results were obtained for FEV1. Conclusion: Airway and parenchymal attenuation parameters are independent predictors of pulmonary function in patients with mild COPD, whereas parenchymal attenuation parameters are dominant independent predictors of pulmonary function in patients with severe COPD.

Coexisting Bronchogenic Carcinoma and Pulmonary Tuberculosis in the Same Lobe: Radiologic Findings and Clinical Significance

  • Young Il Kim;Jin Mo Goo;Hyae Young KIm;Jae Woo Song;Jung-Gi Im
    • Korean Journal of Radiology
    • /
    • 제2권3호
    • /
    • pp.138-144
    • /
    • 2001
  • Objective: Bronchogenic carcinoma can mimic or be masked by pulmonary tuberculosis (TB), and the aim of this study was to describe the radiologic findings and clinical significance of bronchogenic carcinoma and pulmonary TB which coexist in the same lobe. Materials and Methods: The findings of 51 patients (48 males and three females, aged 48-79 years) in whom pulmonary TB and bronchogenic carcinoma coexisted in the same lobe were analyzed. The morphologic characteristics of a tumor, such as its diameter and margin, the presence of calcification or cavitation, and mediastinal lymphadenopathy, as seen at CT, were retrospectively assessed, and the clinical stage of the lung cancer was also determined. Using the serial chest radiographs available for 21 patients, the possible causes of delay in the diagnosis of lung cancer were analyzed. Results: Lung cancers with coexisting pulmonary TB were located predominantly in the upper lobes (82.4%). The mean diameter of the mass was 5.3 cm, and most tumors (n=42, 82.4%) had a lobulated border. Calcification within the tumor was seen in 20 patients (39.2%), and cavitation in five (9.8%). Forty-two (82.4%) had mediastinal lymphadenopathy, and more than half the tumors (60.8%) were at an advanced stage [IIIB (n=11) or IV (n=20)]. The average delay in diagnosing lung cancer was 11.7 (range, 1-24) months, and the causes of this were failure to observe new nodules masked by coexisting stable TB lesions (n=8), misinterpretation of new lesions as aggravation of TB (n=5), misinterpretation of lung cancer as tuberculoma at initial radiography (n=4), masking of the nodule by an active TB lesion (n=3), and subtleness of the lesion (n=1). Conclusion: Most cancers concurrent with TB are large, lobulated masses with mediastinal lymphadenopathy, indicating that the morphologic characteristics of lung cancer with coexisting pulmonary TB are similar to those of lung cancer without TB. The diagnosis of lung cancer is delayed mainly because of masking by a tuberculous lesion, and this suggests that in patients in whom a predominant or growing nodule is present and who show little improvement of symptoms despite antituberculous or other medical therapy, coexisting cancer should be suspected.

  • PDF

Study on Establishment of Space Operation Plan for Yangpyeong-gun Public Library (양평군 공공도서관 공간 운영 계획 수립에 관한 연구)

  • Inho Chang;Younghee Noh;Woojung Kwak
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • 제35권1호
    • /
    • pp.301-324
    • /
    • 2024
  • In this study, we attempted to propose operational directions for each space in order to transform the newly built library in Yangpyeong-gun into a space for cultural enjoyment and creativity development for local residents. To this end, the purpose is to understand the space composition status of Yangpyeong-gun public libraries and establish an operation plan (draft) for the space to be constructed. To this end, we analyzed the names, operation status, and cases of similar spaces in other libraries, and analyzed the spatial characteristics of library cases to establish a space operation plan for the Yangpyeong-gun public library. As a result of the study, it is important to utilize spaces such as children's resource rooms to improve early reading habits for infants and children, contribute to development, and develop various senses, and small theaters should be planned with a focus on large-scale performances. Furniture and space for reading and relaxation should be provided next to Byeokmyeonga & Bookstair, and it should be operated as a communication space where small talk is possible within a certain limit. It is necessary to operate the multipurpose room by activating experiential creative activities and creative performances. It is necessary for the club room to establish an operation plan through regular communication and opinion sharing. The maker space space is a space that supports various creative activities, and the general data room is a place that provides materials on all topics and must be operated by regularly communicating with users and reflecting their opinions. Lastly, I would like to suggest that the family room should be used like a book cafe where children and parents can freely drink tea together in the same space.

Twelve-Month Volume Reduction Ratio Predicts Regrowth and Time to Regrowth in Thyroid Nodules Submitted to Laser Ablation: A 5-Year Follow-Up Retrospective Study

  • Roberto Negro;Gabriele Greco;Maurilio Deandrea;Matteo Rucco;Pierpaolo Trimboli
    • Korean Journal of Radiology
    • /
    • 제21권6호
    • /
    • pp.764-772
    • /
    • 2020
  • Objective: Laser ablation is a therapeutic modality used to reduce the volume of large benign thyroid nodules. Unsatisfactory reduction and regrowth are observed in some treated nodules. The aim of the study was to evaluate the long-term outcomes of laser treatment for solid nodules during a 5-year follow-up period, the regrowth rate, and the predictive risk factors of nodule regrowth. Materials and Methods: We retrospectively evaluated patients with benign, solid, cold thyroid nodules who underwent laser ablation and were followed-up for 5 years. According to the selection criteria, 104 patients were included (median baseline nodule volume, 12.5 mL [25.0-75.0%, 8-18 mL]; median energy delivered, 481.5 J/mL [25.0-75.0%, 370-620 J/mL]). Nodule volume, thyroid function test results, and ultrasound were evaluated at baseline and then annually after the procedure. Results: Of 104 patients, 31 patients (29.8%) had a 12-month volume reduction ratio (VRR) < 50.0% and 39 (37.5%) experienced nodule regrowth. Of these 39 patients, 17 (43.6%) underwent surgery and 14 (35.9%) underwent a second laser treatment. The rate of nodule regrowth was inversely related to the 12-month VRR, i.e., the lower the 12-month VRR, the higher the risk of regrowth (p < 0.001). The mean time for nodule regrowth was 33.5 ± 16.6 months. The 12-month VRR was directly related to time to regrowth, i.e., the lower the 12-month VRR, the shorter the time to regrowth (p < 0.001; R2 = 0.3516). Non-spongiform composition increased the risk of regrowth with an odds ratio of 4.3 (95% confidence interval [CI] 1.8-10.2; p < 0.001); 12-month VRR < 50.0% increased the risk of regrowth with an odds ratio of 11.7 (95% CI 4.2-32.2; p < 0.001). Conclusion: The VRR of thyroid nodules subjected to similar amounts of laser energy varies widely and depends on the nodule composition; non-spongiform nodules are reduced to a lesser extent and regrow more frequently than spongiform nodules. A 12-month VRR < 50.0% is a predictive risk factor for regrowth and correlates with the time to regrowth.

Effect of the initial imperfection on the response of the stainless steel shell structures

  • Ali Ihsan Celik;Ozer Zeybek;Yasin Onuralp Ozkilic
    • Steel and Composite Structures
    • /
    • 제50권6호
    • /
    • pp.705-720
    • /
    • 2024
  • Analyzing the collapse behavior of thin-walled steel structures holds significant importance in ensuring their safety and longevity. Geometric imperfections present on the surface of metal materials can diminish both the durability and mechanical integrity of steel shells. These imperfections, encompassing local geometric irregularities and deformations such as holes, cavities, notches, and cracks localized in specific regions of the shell surface, play a pivotal role in the assessment. They can induce stress concentration within the structure, thereby influencing its susceptibility to buckling. The intricate relationship between the buckling behavior of these structures and such imperfections is multifaceted, contingent upon a variety of factors. The buckling analysis of thin-walled steel shell structures, similar to other steel structures, commonly involves the determination of crucial material properties, including elastic modulus, shear modulus, tensile strength, and fracture toughness. An established method involves the emulation of distributed geometric imperfections, utilizing real test specimen data as a basis. This approach allows for the accurate representation and assessment of the diversity and distribution of imperfections encountered in real-world scenarios. Utilizing defect data obtained from actual test samples enhances the model's realism and applicability. The sizes and configurations of these defects are employed as inputs in the modeling process, aiding in the prediction of structural behavior. It's worth noting that there is a dearth of experimental studies addressing the influence of geometric defects on the buckling behavior of cylindrical steel shells. In this particular study, samples featuring geometric imperfections were subjected to experimental buckling tests. These same samples were also modeled using Finite Element Analysis (FEM), with results corroborating the experimental findings. Furthermore, the initial geometrical imperfections were measured using digital image correlation (DIC) techniques. In this way, the response of the test specimens can be estimated accurately by applying the initial imperfections to FE models. After validation of the test results with FEA, a numerical parametric study was conducted to develop more generalized design recommendations for the stainless-steel shell structures with the initial geometric imperfection. While the load-carrying capacity of samples with perfect surfaces was up to 140 kN, the load-carrying capacity of samples with 4 mm defects was around 130 kN. Likewise, while the load carrying capacity of samples with 10 mm defects was around 125 kN, the load carrying capacity of samples with 14 mm defects was measured around 120 kN.