The influence of acid rain on the marble cultural properties investigated in two ways : 1) marble samples similar to that of Wongak-sa 10-story pagoda were directly exposed to rain in air at Chongro and Kwanghwamun sites; 2) marble samples under a protective facility were indirectly exposed to rain. The quantity of corrosion products and variations of calcium ion to rain were analyzed. The result shows that the corrosion qantity of the marble samples exposed directly under 1~8 mm rainfall in the Chongno and Kwanghwamun sites were similar, but those were 7.7 times higher than those indoor. Concentration of anions were higher than that of cations among the ion concentration over 40% in the early 1 mm rainfall. Calcium ion was produced over 30%. Because the monuments of marble, limestone and sandstone were affected by acid rain, it may be necessary to establish policies for the conservation on the National Treasures made of these materials.
Journal of the Korean Association of Oral and Maxillofacial Surgeons
/
v.37
no.4
/
pp.255-263
/
2011
Introduction: Maxillomandibular fixation (MMF) is essential before surgery under general anesthesia in maxillofacial trauma patients. MMF is used basically to reconstruct the occlusion and occlusal stability to recover the facial shape and oral functions. The arch bar and wire is a traditional method for MMF, but it can not only bring pressure to the periodontal ligaments and teeth but also cause a penetrating injury to the surgeons. Materials and Methods: In this study, 198 patients with an open reduction using a manual reduction without MMF from September 2005 to May 2010 in Dankook University Dental Hospital were subjected to a follow-up evaluation during the postoperative 4 months periods. This study evaluated the incidence of complications according to the condition of the patient (gender, age), the state of bony union of the fracture sites and a numeric rating scale evaluation for postoperative pain scoring. Results: 1. The complications were classified into major and minor according to the seriousness, and the major complication rate was as low as 2.02%. Only 2 cases of re-operations (1.01%) were encountered. In the classification according to the fracture line, plate fracture was observed in both cases of mandibular symphysis fracture, and angle fractures and loosening of two screws were noted in the case of mandibular angle fracture. 2. The complication rate was similar regardless of gender and age. 3. The degree of bony union was satisfactory, and the complication rate was reduced as the bony union improved. 4. More patients complained of pain as the operation time was increased. Conclusion: The use of MMF is not always necessary if a skilled assistant is provided to help manually reduce the fracture site. Compared to other studies of mandibular fracture surgery using MMF, the complication rate was similar using only manual reduction and the patients' discomfort was reduced without MMF.
Cavalline, Tara L.;Calamusa, Jeremy T.;Kitts, Amy M.;Tempest, Brett Q.
International Journal of Concrete Structures and Materials
/
v.11
no.1
/
pp.85-97
/
2017
Research has suggested that conventional lightweight concrete can offer durability advantages due to reduced cracking tendency. Although a number of publications exist providing the results of laboratory-based studies on the durability performance of lightweight concrete (with lightweight coarse aggregate) and internally cured concrete (using prewetted lightweight fine aggregate), far fewer field studies of durability performance of conventional lightweight concrete bridge decks in service have been performed. This study was commissioned to provide insight to a highway agency on whether enhanced durability performance, and therefore reduced maintenance and longer lifecycles, could be anticipated from existing lightweight concrete bridge decks that were not intentionally internally cured. To facilitate performance comparison, each lightweight bridge deck selected for inclusion in this study was paired with a companion normalweight bridge deck on a bridge of similar structural type, deck thickness, and geometric configuration, with similar age, traffic, and environmental exposure. The field-observed cracking of the decks was recorded and evaluated, and crack densities for transverse, longitudinal, and pattern cracking of the normalweight and lightweight deck in each pair were compared. Although some trends linking crack prevalence to geographic location, traffic, and age were observed, a distinct difference between the cracking present in the paired lightweight and normalweight bridge decks included in this study was not readily evident. Statistical analysis using analysis of covariance (ANCOVA) to adjust for age and traffic influence did not indicate that the type of concrete deck (lightweight or normalweight) is a statistically significant factor in the observed cracking. Therefore, for these service environments, lightweight decks did not consistently demonstrate reduced cracking.
Speech intelligibility in patients with complete dentures is an important clinical problem depending on the material used. The objective of this study was to investigate the speech of two edentulous subjects fitted with a complete maxillary prosthesis made of two different palatal materials: chrome-cobalt alloy and acrylic resin. Three patients with complete dentures in the experiment group and ten people in the controls groups participated in the experiment. CSL, Visi-Pitch were used to measure speech characteristics. The test words consisted of a simple vowel /e/, meaningless three syllabic words containing fricative, affricated and stops sounds, and sustained fricative sounds /s/ and /$\int$/. The analysis speech parameters were vowel and lateral formants, VOT, sound durations, sound pressure level and fricative frequency. Data analysis was conducted by a series of paired T-test. The findings like the following: (1) Vowel formant one of patients with complete denture is higher than that of the control group (p<0.05), while lateral formant three of patients with complete denture is lower than that of the control group (p<0.0l). (2) Patients with complete denture produced lower speech intelligibility with low fricative frequency (/$\int$/) than control group (p<0.0). The speech intelligibility of patients with metal prosthesis was higher than that of those with resin prosthesis (p<0.05). (3) Fricative, lateral and stop sound durations of patients with complete denture were longer than those of the control group (p<0.01 and p<0.05), respectively. Total sound durations of patients with metal prosthesis were similar to that of the control group (p<0.05), while those with resin prosthesis had a shorter duration (p<0.01). This implied that those with metal prosthesis had higher speech intelligibility than those with resin prosthesis. (4) Patients with complete denture had higher sound pressure levels /t/ and /c/ than the control group (p<0.01). However, sound pressure levels for /c/ of patients with metal prosthesis or resin prosthesis was similar to the control group (p<0.05). (5) Patients with complete denture had higher fundamental frequency than the control group (p<0.01).
Objective : The mechanism of acupuncture to increase cerebral blood flow is still uncertain. The purpose of this study was to evaluate the neural basis of acupuncture by comparing the cerebral regions activated by the stimulation of two different methods of acupunctures at the same acupoint which was suggested by oriental medicine to increase rCBF. Materials and Methods : Thirty-nine healthy volunteers(26 males, 13 females, age $31{\pm}11$ years) were studies by rest/acupuncture Tc-99m ECD brain SPECT using a subtraction method. SPECTs using two methods(needle retention and heated needle with 90% alcohol) at two acupoints (right LI. 4 and ST. 36) were peformed at an interval of three days. For the needle retention method, acupuncture needle was inserted to a depth of about 2 cm into each acupoint 8 minutes after the lst acquisition and continued to retain, and the second injection of Tc-99m ECD was done 15 minutes after the insertion of needle. For the heated acupuncture method, heated needle was inserted in a twinkle within several msec 20 second after the second injection of Tc-99m ECD. The differences of between rest and acupuncture activation state were statistically analyzed using a statistical parametric mapping software. Result : Acupunctures of both methods reveal similar patterns of increase in rCBF. Acupuncture at ST.36 increase rGBF in left anterior temporal, right inferior frontal lobes, and left cerebellum. Acupuncture at LI. 4 increase rCBF in the left frontal cortex, right temporal pole, both inferior frontal cortices and right cerebellum. Conclusion : The effects of two different acupunctures to the same acupoints on rCBF were similar. Therefore, this result suggests Chat the mechanism of acupuncture in the increase of cerebral blood flow have a neural basis.
Kim, Da-Hye;Son, Jun-Sik;Jeong, Seong-Hwa;Kim, Young-Kyung;Kim, Kyo-Han;Kwon, Tae-Yub
The Journal of Advanced Prosthodontics
/
v.7
no.2
/
pp.85-92
/
2015
PURPOSE. This study aimed to investigate the efficacy of cleaning solutions on saliva-contaminated zirconia in comparison to air-abrasion in terms of resin bonding. MATERIALS AND METHODS. For saliva-contaminated air-abraded zirconia, seven cleaning methods)-no contamination (NC), water-spray rinsing (WS), additional air-abrasion (AA), and cleaning with four solutions (Ivoclean [IC]; 1.0 wt% sodium dodecyl sulfate [SDS], 1.0 wt% hydrogen peroxide [HP], and 1.0 wt% sodium hypochlorite [SHC])-were tested. The zirconia surfaces for each group were characterized using various analytical techniques. Three bonded resin (Panavia F 2.0) cylinders (bonding area: $4.5mm^2$) were made on one zirconia disk specimen using the Ultradent jig method [four disks (12 cylinders)/group; a total of 28 disks]. After 5,000 thermocycling, all specimens were subjected to a shear bond strength test with a crosshead speed of 1.0 mm/minute. The fractured surfaces were observed using an optical and scanning electron microscope (SEM). RESULTS. Contact angle measurements showed that groups NC, AA, IC, and SHC had hydrophilic surfaces. The X-ray photoelectron spectroscopy (XPS) analysis showed similar elemental distributions between group AA and groups IC and SHC. Groups IC and SHC showed statistically similar bond strengths to groups NC and AA (P>.05), but not groups SDS and HP (P<.05). For groups WS, SDS, and HP, blister-like bubble formations were observed on the surfaces under SEM. CONCLUSION. Within the limitations of this in vitro study, some of the cleaning solutions (IC or SHC) were effective in removing saliva contamination and enhancing the resin bond strength.
PURPOSE. The aims of this pilot study were to introduce implant loading devices designed for animal study and to evaluate the validity of the load transmission ability of the loading devices. MATERIALS AND METHODS. Implant loading devices were specially designed and fabricated with two implant abutments and cast metal bars, and orthodontic expansion screw. In six Beagles, all premolars were extracted and two implants were placed in each side of the mandibles. The loading device was inserted two weeks after the implant placement. According to the loading protocol, the load was applied to the implants with different time and method, simulating early, progressive, and delayed loading. The implants were clinically evaluated and the loading devices were removed and replaced to the master cast, followed by stress-strain analysis. Descriptive statistics of remained strain (${\mu}{\varepsilon}$) was evaluated after repeating three cycles of the loading device activation. Statistic analysis was performed using nonparametric, independent t-test with 5% significance level and Friedman's test was also used for verification. RESULTS. The loading devices were in good action. However, four implants in three Beagles showed loss of osseointegration. In stress-strain analysis, loading devices showed similar amount of increase in the remained strain after applying 1-unit load for three times. CONCLUSION. Specialized design of the implant loading device was introduced. The loading device applied similar amount of loads near the implant after each 1-unit loading. However, the direction of the loads was not parallel to the long axis of the implants as predicted before the study.
To examine sediment characteristics and find anthropogenic effects on riverine wetland ecosystems, paleoecological study was carried out at Bam islands in Seoul. Three hundred cm deep sediment cores were retrieved and dated with the lamination analysis method until 36 cm depth (1986). Sediments were divided into three zones based on the depth profiles of physico-chemical variables: below 160 cm depth (before 1968), between 160 and 40cm depths and above 40cm depth (after 1986). Physico-chemical characteristics were very variable between 160 and 40cm depths and this indicates unstable sedimentation environment. Even though heavy metal concentrations were relatively low, Cd and As contents have increased continuously. Dry mass accumulation rates during $1968{\sim}1986\;and\;1987{\sim}2003$ were 140 and $21\;kg\;m^{-2}\;yr^{-1}$, respectively. This was related to flooding intensity and duration. Bulk density, water content, loss on ignition, N, C, C/N ratio were very similar to other river delta but Ca, Na and K contents were 2 to 4 times higher than others. Heavy metal contents except Pb were lower or similar to those in other studied marshes in Korea. Heavy metal and Mg contents were correlated with each other and this suggests that the source of heavy metals be parent rock. From $^{13}C$ dating dates of organic materials in sediment, it is suggested that organic matter originated from the watershed and flooding intensity in the watershed might be responsible for the source of sediments. This study provides reference data for the comparison of sediment characteristics at islands in river and for the management of Bam islands.
Objectives: This micro-computed tomographic (CT) study aimed to compare the shaping abilities of ProTaper Next (PTN), One Shape (OS), and One Curve (OC) files in 3-dimensionally (3D)-printed mandibular molars. Materials and Methods: In order to ensure standardization, 3D-printed mandibular molars with a consistent mesiobuccal canal curvature (45°) were used in the present study (n = 18). Specimens were instrumented with the OC, OS, or PTN files. The teeth were scanned pre- and post-instrumentation using micro-CT to detect changes of the canal volume and surface area, as well as to quantify transportation of the canals after instrumentation. Two-way analysis of variance was used for statistical comparisons. Results: No statistically significant differences were found between the OC and OS groups in the changes of the canal volume and surface area before and after instrumentation (p > 0.05). The OC files showed significantly less transportation than the OS or PTN systems for the apical section (p < 0.05). In a comparison of the systems, similar values were found at the coronal and middle levels, without any significant differences (p > 0.05). Conclusions: These 3 instrumentation systems showed similar shaping abilities, although the OC file achieved a lesser extent of transportation in the apical zone than the OS and PTN files. All 3 file systems were confirmed to be safe for use in mandibular mesial canals.
Proteins combine with other materials to achieve their function and have similar function if their active sites are similar. Thus we can infer the function of protein by identifying the binding area of proteins. This paper suggests the novel method to select binding area of protein using MCL (Markov Cluster) algorithm. We construct the distance matrix from surface residues distance on protein. Then this distance matrix is transformed to connectivity matrix for applying MCL process. We adopted Catalytic Site Atlas (CSA) data to evaluate the proposed method. In the experimental result using CSA data (94 selected single chain proteins), our algorithm detects the 91 (97%) binding area near by active site of each protein. We introduced a new geometrical features and this mainly contributes to reduce the time to analyze the protein by selecting the residues near by active site.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.