• Title/Summary/Keyword: similar material

Search Result 3,185, Processing Time 0.032 seconds

Surface characteristics and stability of implants treated with alkali and heat (알칼리와 열처리에 의한 임플란트의 표면 특성 및 골유착 안정성에 관한 연구)

  • Song, Yun-Seok;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.490-499
    • /
    • 2008
  • Statement of problem: Bioactive materials must have the ability to spontaneously form a bone like apatite layer on their surface and induce direct biochemical bonding to bone. A simple chemical treatment via alkali and heat has been revealed to induce bioactivity in titanium. Purpose: The purpose of this study was to evaluate the surface characteristics and stability of alkali and heat treated implants. Material and methods: Specimens were divided into three groups; group 1 was the control group with machined surface implants, groups 2 and 3 were treated with alkali solutions and heat treated in the atmosphere and vacuum conditions respectively. The surface characteristics were observed with FESEM, XPS, TF-XRD and AFM. Stability was evaluated with the resonance frequency analysis, periotest and removal torque values. One-way ANOVA and Duncan test were used for statistical analysis. Results: 1. Groups treated with alkali and heat showed similar characteristics. Groups 2 and 3 showed high compositions of Na ions on the surface with sub-micron sized pores compared to group 1. Group 2 showed mixed compositions of anatase and rutile with superior contents of rutile. 2. Resonance frequency analysis : The ISQ of group 2 showed significantly higher values than that of groups 1 and 3 at 12 weeks. The ISQ of groups 1 and 2 showed significant increase after 4 weeks, and the ISQ of group 3 increased significantly after 2 and 4 weeks respectively (P < .05). 3. Periotest: The PTV of groups 1 and 2 showed significant decrease after 4 weeks, and the PTV of group 3 showed significant decrease after 2 and 4 weeks respectively (P < .05). 4. Removal torque analysis: The removal torque value of group 2 was significantly higher than those of groups 1 and 3 at 2, 4 and 8 weeks. The removal torque values of groups 1 and 3 showed increase at 4 and 12 weeks, but the removal torque value of group 2 showed increase after 4 weeks (P < .05). Conclusion: An oxide layer with appropriate crystal structure and amorphous sodium titanate layer can be obtained on titanium implants through alkali and heat treatment in the atmosphere, and even alkali and heat treatment in vacuum conditions, provided a bioactive surface containing sodium. These surface layers can be considered to be effective for enhancement of osseointegration and reduction of healing period for implant treatment.

A Study on the Meaning and Types of Banpo [斑布] during the Joseon Dynasty (조선시대 반포(斑布)의 의미와 형식 연구)

  • Ree, Jiwon
    • Korean Journal of Heritage: History & Science
    • /
    • v.53 no.3
    • /
    • pp.164-183
    • /
    • 2020
  • In the textile culture of the Joseon Dynasty, the historic record of Banpo is fragmentary and contains many missing details. The main reason is a lack of associated literature, and it is also significant that the actual substance used is not clear at present. Banpo is a kind of cotton, but this has not been confirmed in the traditional textiles that are currently handed down. The word Ban [斑] in Banpo means "stain", and the letter Po [布] means "fabric". At the border of white discourse, Banpo did not receive attention as a research topic. This study is an attempt to restore some of the textile culture of the Joseon Dynasty through Banpo. Banpo is not just limited to the Joseon Dynasty; it is an important material for examining the development of textile culture and exchange in East Asia. This study was broadly divided into three parts. First, the record and meaning of Banpo during the Joseon Dynasty were examined. Records of Banpo can be seen from the early Joseon period during King Sejo and Seongjong, and the production and actual use of Banpo have been confirmed. Banpo was maintained until the beginning of the 20th century, but is no longer observed. Banpo is a woven fabric made of cotton yarn dyed in many colors and has appeared in Southeast Asia since ancient times. In East Asia, there are other fabrics similar to Banpo, such as Ho [縞], Sum [纖], and Chim [綅]. In particular, the correlation between Banpo and Ho is an important link in understanding Banpo in the Joseon Dynasty. Second, the meaning of Banpo was examined from various angles through comprehensive analysis of Chinese and Japanese literature records and cases. The appearance and development of Banpo moved in sync with the period when cotton was introduced into East Asia. In East Asia, cotton was introduced and produced in earnest from the end of the Song Dynasty to the beginning of the Yuan Dynasty, and the meaning of Banpo was diversified. In China, the name of Banpo was changed to Hwapo [花布], Gizapo [碁子布], Gizahwapo [棋子花布], etc. Japan was late to introduce cotton and developed it in acceptance of the changed meaning. In Japan, use of the name Banpo is not on record, but a Ryujo [柳條] fabric of the same type as banpo has been identified. This Ryujo is the same concept as Ho and Hwapo, and later merged into Ho. Names such as Ho, Hwapo, Banpo, etc. were used differently in each country, but the form was shared across East Asia. Third, based on the meaning of Banpo shared in East Asia, the format of Banpo in the Joseon Dynasty was classified. The format of Banpo in the Joseon Dynasty can be divided into grid and striped versions. The name Banpo disappeared over time, but the form remained and was passed down until recently. I hope that this study will help restore Banpo in the future.

1910's Tap-gol Park Construction Process through Design Document Interpretation (설계도서를 중심으로 본 1910년대 탑골공원의 성립과정)

  • Kim, Hai-Gyoung;Kim, Young-Soo;Yun, Hye-Jin
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.31 no.2
    • /
    • pp.103-117
    • /
    • 2013
  • This research analyzed the spatial components and establishment of the Tap-gol Park according to the plans between 1897 to 1916 when the discussions on the construction of the park began and it was accomplished as an urban park. The results are as follows. The establishment of Tap-gol Park can be divided by three period. Firstly, Tap-gol Park was owned by the royal family from 1987 to 1904. The discussions on construction of Tap-gol Park as a first urban park of Gyeongseong(京城) in 1897, and the private houses were tear down in order to secure land for the park in 1899. Gates and fences surrounding of Tap-gol Park were organized and it was opened in 1902 based on park plane of turtle - shaped. The octagonal pavilion for 'Lee-Wang-Jik musical band(李王職音樂隊)' was relocated in the southwestern part of the park in 1903. Secondly, Tap-gol Park was used actively by the public between 1910 to 1913, because it was opened for individuals. Also The boundary of Park were changed by surrounding facilities and recreational facilities and benefits was complemented for users. Tap-gol park was opened at nighttime in August 1913. Tap-gol Park was used as a place of amusement park. Thirdly, commercial facilities were made as the park facility between 1914 to 1916. The purpose of 'Kkikdajeom(喫茶店)' was similar to the one of modern cafes. It was built as a typical Japanese tea-house with a small pond having an island and a bridge constructed inside. With the increase of usage of Tap-gol Park as a recreational area by the citizens in 1916, the pavilion as a rest area and toilet as amenities were supplemented. Superintendent's office was equipped too. Simple chairs made from the wooden logs were installed around greenhouse, concert hall, the Wongaksa Buddhist temple(圓覺寺址十層石塔), and the flower garden was fenced round. After the relocation of Yongsan music band to Tap-gol Park, the existing concert hall was demolished. The shape of the park which was seen from the pictures of the magazines of 1920s were achieved as early as 1916. The importance of this research includes the basis to revise the errors of the preexistence researches and value of historical material of the design plan reference of the park which was accomplished during the Japanese colonial era. Also this research is to study on the spatial components of the modern landscape architecture and parks.

Study of Anti-oxidant Analysis to Vegetable Juice Containing Barley Sprouts (보리새싹 함유 녹즙의 항산화력 분석에 관한 연구)

  • Yoo, In-Sik;Baek, Cheong-Mok;Joung, Mi-Yeun;Kwon, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.248-253
    • /
    • 2017
  • This study was conducted to analyze the anti-oxidant activity of green juice containing barley sprouts. The specimens used in the experiments were supplied byCSJ company located in Jincheon-gun, Chungbuk province. Polyphenol and flavonoid was detected in Huttuynia cordata Thunb fermentation sprout juiceat $1.075{\pm}0.174mg/mL$ and $2.736{\pm}0.187\;quercetin\;mg/mL$, in organic dandelion at $1.048{\pm}0.173mg/mL$ and $2.685{\pm}0.245\;quercetin\;mg/mL$, kan andRakat $1.013{\pm}0.083mg/mL$ and $3.624{\pm}0.237\;quercetin\;mg/mL$, broccoli blending juice at $1.494{\pm}0.255mg/mL$ and $3.826{\pm}0.286\;quercetin\;mg/mL$, and barley sprouts at $1.043{\pm}0.220mg/mL$ and $1.990{\pm}0.223\;quercetin\;mg/mL$, respectively.Antioxidant activity testing revealed the electron donating ability of Huttuynia cordata Thunb fermentation sprout juice for DPPH was 81.97%. Moreover, the free radical scavenging ability measured by ABTS assay showed that the activity was increased in the order of broccoli blending juice, Huttuynia cordata Thunb fermentation sprout juice, organic dandelion, 'kan andRak', barley sprout, and thatthe effects were similar to those of ascorbic acid at $100{\mu}g/mL$. Statistical processing is using SPSS 24, analysis of distributed layout and Duncan's multiple range (p<0.05). Therefore, the use of functional assistance material of products in the future indicates that it is worth a healthy functional drink.

A comparative study of dose distribution for whole brain with field-in-field technique (전뇌(Whole Brain)치료 시 Field-in-Field Technique 적용에 관한 고찰)

  • Kim Bo Kyoum;Lee Je Hee;Jung Chi Hoon;Pack Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.9-17
    • /
    • 2005
  • Purpose : Uniform dose distribution of the target volume is very important in the radiation treatment. We will evaluate the usefulness of Field-in-Field Technique use to get uniform dose distribution of the target volume and try to find Apply possibility out to a whole brain treatment patient of various thickness. Material and method : We compare the dose distribution when we applied Field-in-Field Technique and parallel opposed fields technique. establish the treatment plan to a phantom(acryl 16cm spheral phantom) and do the measurement, assessment use the TLD and Low sensitivity film. Also the assessment did Apply possibility of Field-in-Field Technique to 20 patient object of various thickness. Result : In the case to use the parallel opposed fields at the whole brain treatment $10-12\%$ high dose region appeared but reduce to $3-4\%$ lesses when we used the Field-in-Field technique. We could get similar numerical value the film and TLD measurement result also. The change of the dose distribution appeared to its ${\pm}1{\sim}2\%$ although it applied such Field-in-Field technique to various patient so that we were identical. Conclusion : We can get uniform dose distribution of in the treatment region if we apply the Field-in-Field technique at the whole brain treatment. Also alternate can play the role of the wedge filter and 3D compensator and We are thought by minimizing the obstacle to be happened due to the high dose region when radiation treatment.

  • PDF

Efficacy of Positron Emission Tomography in Diagnosing Pulmonary Tumor and Staging of Lung Cancer : Comparing to Computed Tomography (폐종양과 폐암의 병기결정에 대한 양전자단층촬영(PET)의 유용성 -전산화단층촬영 (CT)과의 비교-)

  • 김오곤;조중행;성숙환
    • Journal of Chest Surgery
    • /
    • v.36 no.2
    • /
    • pp.79-85
    • /
    • 2003
  • Diagnosing and determining the stage of lung cancer by means of positron emission tomography (PET) ha.. been proven valuable because of the limitations of diagnosis by computed tomography (CT). We compared the efficacy of PET with that of CT in diagnosing pulmonary tumor and staging of lung cancer Material and Method: We performed F-18 FDG PET to determine the malignancy and the staging on patients who have been suspicious or were diagnosed as lung cancer by chest X-ray and CT. The findings of PET and of CT of 41 patients (male, 29: female, 12: mean age, 59) were compared with pathologic findings obtained from a mediastinoscopy and thoracotomy. Result: Out of 41 patients, 35 patients had malignant lesions (squamous cell carcinonla 19 cases, adenocarcinoma 14 cases, adenosquamous cell carcinoma 2 cases) and 6 patients had benign lesions. Diagnosing of lung cancer, the sensitivity, specificity and accuracy of CT and PET were the same for two method and the numbers were 100%, 50%, and 92.7% respectively. Eighteen LN groups out of 108 mediastinal LN groups who recieved histologic examination proved to be malignant. Pathologic lymph node (LN) stage was N0-Nl 31 cases, N2 8 cases, N3 2 cases. The correct identification of the nodal staging with CT, PET scans were 31 cases (75.6%), 28 cases (68.3%) respectively. The LN group was underestimated in each 6 cases of CT and PET. In 4 cases of CT and 7 cases of PET, they were overestimated in compare to histologic diagnosis. In the detection of mediastinal LN groups invasion, the sensitivity, specificity and accuracy of CT were 39.8 %, 93.3 %, and 84.3 % respectively. For PET, they were 61.1 %, 90.0 %, and 85.2 %. When two methods considered together (CT+PET), they were increased to 77.8 %, 93.3 %, and 90.7 % respectively. Conclusion: PET appears to be similar to CT in the diagnosis and the nodal taging of pulmonary tumor. Two tests may stage patients with lung cancer more accurately than CT alone.

Application of the Pulsatile Cardiopulmonary Bypass in Animal Model (이중 박동성 인공심폐기의 동물 실험)

  • Shin, Hwa-Kyun;Won, Yong-Soon;Lee, Jea-Yook;Her, Keun;Yeum, Yook;Kim, Seung-Chul;Min, Byoung-Goo
    • Journal of Chest Surgery
    • /
    • v.37 no.1
    • /
    • pp.1-10
    • /
    • 2004
  • Background: Currently, the cardiopulmonary machine with non-pulsatile pumps, which are low in internal circuit pressure and cause little damage to blood cells, is widely used. However, a great number of experimental studies shows that pulsatile perfusions are more useful than non-pulsatile counterparts in many areas, such as homodynamic, metabolism, organ functions, and micro-circulation. Yet, many concerns relating to pulsatile cardiopulmonary machines, such as high internal circuit pressure and blood cell damage, have long hindered the development of pulsatile cardiopulmonary machines. Against this backdrop, this study focuses on the safety and effectiveness of the pulsatile cardiopulmonary machines developed by a domestic research lab. Material and Method: The dual-pulsatile cardiopulmonary bypass experiment with total extracorporeal circulation was conducted on six calves, Extracorporeal circulation was provided between superior/inferior vena cava and aorta. The membrane oxygenator, which was placed between the left and right pumps, was used for blood oxygenation. Circulation took four hours. Arterial blood gas analysis and blood tests were also conducted. Plasma hemoglobin levels were calculated, while pulse pressure and internal circuit pressure were carefully observed. Measurement was taken five times; once before the operation of the cardiopulmonary bypass, and after its operation it was taken every hour for four hours. Result: Through the arterial blood gas analysis, PCO2 and pH remained within normal levels. PO2 in arterial blood showed enough oxygenation of over 100 mmHg. The level of plasma hemoglobin, which had total cardiopulmonary circulation, steadily increased to 15.87 $\pm$ 5.63 after four hours passed, but remained below 20 mg/㎗. There was no obvious abnormal findings in blood test. Systolic blood pressure which was at 97.5$\pm$5.7 mmHg during the pre-circulation contraction period, was maintained over 100 mmHg as time passed. Moreover, diastolic blood pressure was 72.2 $\pm$ 7.7 mmHg during the expansion period and well kept at the appropriate level with time passing by. Average blood pressure which was 83$\pm$9.2 mmHg before circulation, increased as time passed, while pump flow was maintained over 3.3 L/min. Blood pressure fluctuation during total extracorporeal circulation showed a similar level of arterial blood pressure of pre-circulation heart. Conclusion: In the experiment mentioned above, pulsatile cardiopulmonary machines using the doual-pulsatile structure provided effective pulsatile blood flow with little damage in blood cells, showing excellence in the aspects of hematology and hemodynamic. Therefore, it is expected that the pulsatile cardiopulmonary machine, if it becomes a standard cardiopulmonary machine in all heart operations, will provide stable blood flow to end-organs.

Endoscopic Radial Artery Harvest: Techniques & Results (내시경을 이용한 요골동맥 수확법의 수술 방법과 결과)

  • Jeong, Young-Kyun;Lee, Jong-Tae;Cho, Jun-Yong;Kim, Kyu-Tae;Chang, Bong-Hyun
    • Journal of Chest Surgery
    • /
    • v.39 no.1 s.258
    • /
    • pp.35-41
    • /
    • 2006
  • Background: The radial arteries are being used more often for coronary artery bypass grafting, We tried to the endoscopic radial artery harvest to reduce the cosmetic problems and neurologic complications of the conventional open harvesting and report the techniques and early results. Material and Method: The 86 patients underwent coronary artery bypass grafting between May 2003 and April 2005 had their nondominant radial artery endoscopically removed through a 2 cm incision at the wrist. The radial pedicle was dissected and was divided at antecubial area through a 5 mm counterincision. Result: The 23 patients complained of neuralgias on territory of superficial raidal none but no one complained of neuralgias on territory of lateral antebrachial cutaneous none. There was no functional impairment of the hand. There was no wound complication except a localized hematoma. All patients were contacted by telephone after postoperative 7.9$\pm$3.6 months. The 4 patients still complained of neuralgia. All the patients were satisfied with the aesthetics of the wounds. The multidetectional tomography was done on the 66 patients for the estimation of early patency of radial artery. There were 2 cases of stenosis and a case of occlusion. Conclusion: Endoscopic radial artery harvest had no functional impairment of the hand, lesser rate of neurologic complications and outstanding aesthetics. The results of early patency of the radial artery was similar to conventional methods. Therefore, we think that endoscopic radial artery harvest is the optimal procedure.

Video Assisted Thoracoscopic Sympathetic Ramus Clipping in Essential Hyperhidrosis -Cadaver Fitting Test and Clinical Application (다한증 환자에서 클립을 이용한 교감신경 교통가지 차단술 -사체 연구 및 임상적용-)

  • Lee, Sung-Ho;Cho, Seong-Joon;Jung, Jae-Seung;Kim, Tae-Sik;Son, Ho-Sung;Sun, Kyung;Kim, Kwang-Taik;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.36 no.8
    • /
    • pp.595-601
    • /
    • 2003
  • Background: It has been known that the most effective treatment method of hyperhidrosis is video-assisted thoracoscopic sympathetic nerve block. Postoperative compensatory hyperhidrosis and anhidrosis are major factors that decrease the postoperative satisfaction. Although sympathetic rami have been selectively blocked to decrease the complications, technical difficulties and excessive bleeding have prevented the universal application. Material and Method: Three pre-fixative cadavers were dissected before clinical application. Bilateral sympathetic chains were exposed in supine position after the whole anterior chest wall was removed. Second and third sympathetic rami were blocked using clips. After the sympathetic chains including ganglia were removed, we evaluated the extents of rami block. Twenty-five patients were subjected to the clinical application. Surgeries were performed in semi-fowlers position under general anesthesia and bilateral ventilation. 2 mm thoracoscopy and 5 mm trocar were intro-duced through third and fourth intercostal space, respectively. Second and third sympathetic rami were blocked using thoracoscopic clips. The postoperative complications, satisfaction, and compensatory hyperhidrosis rate were evaluated retrospectively. Result: Sympathetic rami were completely blocked in cadaver dissection study Hyper-hidrosis symptom was improved in all patients without operative complication. Operative time was shorter than that of traditional ramicotomy. All patients, except four, were satisfied with postoperative palmar hyperhidrosis. Com-pensatory hyperhidrosis was more severely happened in fifteen patients (60%). The remaining six patients had no complaint. Two patients had a minimal degree of gustatory hyperhidrosis. Conclusion: This operative method had shorter operative time and less complication rate, compared with traditional ramicotomy Operative success rate was similar to the traditional syrnpathicotorny; lower extent and occurrence rate of compensatory hyperhidrosis. The thoracic sympathetic rami clipping was suggested as an alternative method for treatment of palmar hyperhidrosis.

Analysis of Urine Iodine Excretion Decrease by Two-Week Stringent Low Iodine Diet for Remnant Thyroid Ablation with Radioactive Iodine in Korean Patients with Thyroid Cancer; Prospective Study (한국 갑상선암 환자들에서 잔여갑상선 제거를 위한 방사성요오드 치료 전 2주간의 엄격한 저요오드식이에 의한 소변 내 요오드량 감소 분석; 전향적 연구)

  • Choi, Joon-Hyuk;Kim, Hoon-Il;Park, Jang-Won;Song, Eun-Hoon;Ko, Bong-Jin;Cheon, Gi-Jeong;Kim, Byung-Il
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.375-382
    • /
    • 2008
  • A low iodine diet (LID) is the recommended preparation for radioactive iodine treatment. However, the recommended duration and stringency of LID are different among each recommendation. More stringent LID is expected in Korea because Korea is a iodine-rich region. We investigated the decrement of urine iodine excretion by two-week stringent LID for remnant thyroid ablation with radioactive iodine in Korean patients with thyroid cancer, prospectively. Material and Method: From November 2006, patients who referred to our hospital for remnant ablation after total thyroidectomy were included in this study. To decrease total body iodine, our protocol included three strategies. First, we checked medication which could inhibit the radioactive iodine uptake. Second, the date of 1-131 treatment was scheduled at least 3 months later if contrast agent had been used. The last strategy was two-week stringent LID education by specialized nutritionist. Before and after two-week stringent LID, 24hr-urine iodine was analyzed respectively. 24hr-urine creatinine was also analyzed for determining more valid 24hr urine sampling subgroup. Results: Total 51 patients were finally enrolled. Average of 24hr-urine iodine excretion was significantly lowered ($787{\pm}2242\;{\rightarrow}\;85{\pm}85\;{\mu}g/d$, p=0.03) after LID and 74.4% of patients reached below the recommended urine iodine excretion level ($<100\;{\mu}g/d$). In subgroup (n=14), similar results was showed ($505{\pm}666\;{\rightarrow}\;99{\pm}116\;{\mu}g/d$, p=0.05) and 78.6% of patients met the criteria. Conclusion: Most patients could reach below the recommended urine iodine level after two-week stringent LID. Therefore, in our opinion, at least two-week stringent LID should be recommended in Korea.