• Title/Summary/Keyword: similar material

Search Result 3,185, Processing Time 0.028 seconds

Comparison of Myocardial Protective Effect between the Cold Blood Cardioplegia and Histidine-Tryptophan-Ketoglutarate Solution (심정지 시 냉혈 심정지액과 Histidine-Tryptophan-Ketoglutarate 용액의 심근보호 효과에 대한 비교 분석)

  • 이덕헌;금동윤;최세영;이광숙;유영선;박남희
    • Journal of Chest Surgery
    • /
    • v.37 no.9
    • /
    • pp.735-741
    • /
    • 2004
  • Blood cardioplegia is known as an established cardioplegic solution during open heart surgery. Recently, the Histidine-Tryptophan-Ketoglutarate (HTK) solution has been introduced as a cardioplegia in Korea. This study was designed to compare the myocardial protective effect between the cold blood cardioplegia (CBC) and HTK solution. Material and Method: Forty patients who underwent valve surgery or coronary artery bypass surgery were randomly divided into CBC group (n=20) and HTK group (n=20). The perioperative hemodynamic and clinical data were analyzed. The concentration of CK-MB, Troponin 1 and Lactate from coronary sinus and radial arterial blood were compared for the evaluation of the myocardial damage. The postoperative serial CK-MB levels were measured. Result: The characteristics of preoperative patients were similar in two groups. The hemodynamic parameters and postoperative clinical data were also similar between the two groups. There were no statistical significances between the CBC and HTK group in the difference of biochemical markers: Δ CK-MB (15.3$\pm$26.0 vs 19.3$\pm$14.3), ΔTro-1 (2.4$\pm$4.9 vs 2.0$\pm$2.20), ΔLac (1.6$\pm$1.0 vs 1.9$\pm$2.5). The serial CK-MB levels were not significantly different between the two groups. Conclusion: These results suggested that the myocardial protective effect of HTK solution was similar to cold blood cardioplegia during open heart surgery.

A MOLECULAR BIOLOGIC STUDY ON BIOCOMPATIBILITY OF METALLIC DENTAL MATERIALS USED FOR CHILDREN WITH CULTURED HUMAN GINGIVAL FIBROBLASTS (인체 섬유모세포(HGF-1) 배양에서 소아용 치과금속재의 세포친화성에 대한 분자생물학적 연구)

  • Kim, Ju-Mi;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.2
    • /
    • pp.243-254
    • /
    • 2002
  • For the purpose of evaluating the biocompatability of 3 kinds of metallic materials frequently used in pediatric dentistry (stainless steel crown, orthodontic band, orthodontic wire), cellular and molecular studies, including cell growth and proliferation, screening of cell death with determination of types whether necrosis or apoptosis and changes in expressions of related signaling molecules were examined, using cultured human gingival fibroblasts (HGF-1), HGF-1 was cultured in Dulbecco's modified Eagle's medium. among which the 3rd to 6th generations of HGF-1 were used. The specimen were divided into stainless steel crown (R), band (B) and wire (W). The immunocytochemical study was done for the detection of anti-PCNA (proliferating cell nuclear antigen) labeling. With extracted protein, western blot was done for the detection of ERK1/2, JNK, and p38, using individual antibodies. Cultured cells proliferated, remarkably till 7 day and slightly at 11 day. There was no statistical significance in the counts of proliferating HGF-1 between control and experimental groups (p>0.05). Relative growth rates were no statistically significant difference between control and experimental groups (p>0.05). PCNA labeling indexes showing similar patterns in control and experimental groups. The expressions of ERK1 and ERK2, p38 were similar in control and experimental groups. The expression of JNK increased at 1st day, slightly decreased at 4th day and markedly increased at 7th and 11 day. Although the patterns of control and experimental groups were similar, the increased expressions of JNK at late period suggest a possible stress due to inhibited cell growth and proliferation, and worse culture condition. Conclusively, the 3 kinds of metal specimens used in this study did not induce cellular and molecular hazards during short term culture of HGF-1. But, for the better clinical stability, the establishment of long period culture and animal experiment was thought necessary.

  • PDF

A Distinctive Chemical Composition of the Tektites from Thailand and Vietnam, and Its Geochemical Significance (타이와 베트남에서 수집된 텍타이트의 화학조성과 지구화학적 의의)

  • Lee, Seung-Gu;Tanaka, Tsuyoshi;Asahara, Yoshihiro;Minami, Masayo
    • The Journal of the Petrological Society of Korea
    • /
    • v.26 no.3
    • /
    • pp.281-295
    • /
    • 2017
  • We determined chemical compositions like abundance of major and trace elements, Sr and Nd isotope compositions for two tektites from the Thailand and Vietnam. Their chemical compositions are similar to each other, and seem to be similar to those of PAAS (Post Archean Australian Shale) rather than upper continental crust. In particular, primitive mantle-normalized spider diagrams and chondrite-normalized REE patterns for two tektites are the same, suggesting that they might be derived from the same source material. The $^{87}Sr/^{86}Sr$ and $^{143}Nd/^{144}Nd$ ratios from Thailand tektite are $0.718870{\pm}0.000008(2{\sigma}_m)$ and $0.512024{\pm}0.000012(2{\sigma}_m)$, respectively, and those from Vietnam are $0.717022{\pm}0.000008(2{\sigma}_m)$ and $0.511986{\pm}0.000013(2{\sigma}_m)$, respectively. The $^{87}Sr/^{86}Sr$ and $^{143}Nd/^{144}Nd$ ratios from Thailand tektite are slightly enriched than those of Vietnam tektite. $^{87}Sr/^{86}Sr$ ratios from the Vietnam and Thai tektites were plotted on the range of Australasian tektites reported previously. $^{143}Nd/^{144}Nd$ ratio of Vietnam tektite from this study was lower than the range of $^{143}Nd/^{144}Nd$ ratio from the Australasian tektite reported previously whereas that of Thai tektite was included in the range of $^{143}Nd/^{144}Nd$ ratio from the Australasian tektite. The geochemical characteristics from two tektites in this study indicate that they may be derived from the very similar source materials.

Manufacturing Techniques of Bronze Medium Mortars(Jungwangu, 中碗口) in Joseon Dynasty (조선시대 중완구의 제작 기술)

  • Huh, Ilkwon;Kim, Haesol
    • Conservation Science in Museum
    • /
    • v.26
    • /
    • pp.161-182
    • /
    • 2021
  • A jungwangu, a type of medium-sized mortar, is a firearm with a barrel and a bowl-shaped projectileloading component. A bigyeokjincheonroe (bombshell) or a danseok (stone ball) could be used as a projectile. According to the Hwaposik eonhae (Korean Translation of the Method of Production and Use of Artillery, 1635) by Yi Seo, mortars were classified into four types according to its size: large, medium, small, or extra-small. A total of three mortars from the Joseon period have survived, including one large mortar (Treasure No. 857) and two medium versions (Treasure Nos. 858 and 859). In this study, the production method for medium mortars was investigated based on scientific analysis of the two extant medium mortars, respectively housed in the Jinju National Museum (Treasure No. 858) and the Korea Naval Academy Museum (Treasure No. 859). Since only two medium mortars remain in Korea, detailed specifications were compared between them based on precise 3D scanning information of the items, and the measurements were compared with the figures in relevant records from the period. According to the investigation, the two mortars showed only a minute difference in overall size but their weight differed by 5,507 grams. In particular, the location of the wick hole and the length of the handle were distinct. The extant medium mortars are highly similar to the specifications listed in the Hwaposik eonhae. The composition of the medium mortars was analyzed and compared with other bronze gunpowder weapons. The surface composition analysis showed that the medium mortars were made of a ternary alloy of Cu-Sn-Pb with average respective proportions of (wt%) 85.24, 10.16, and 2.98. The material composition of the medium mortars was very similar to the average composition of the small gun from the Joseon period analyzed in previous research. It also showed a similarity with that of bronze gun-metal from medieval Europe. The casting technique was investigated based on a casting defect on the surface and the CT image. Judging by the mold line on the side, it appears that they were made in a piece-mold wherein the mold was halved and using a vertical design with molten metal poured through the end of the chamber and the muzzle was at the bottom. Chaplets, an auxiliary device that fixed the mold and the core to the barrel wall, were identified, which may have been applied to maintain the uniformity of the barrel wall. While the two medium mortars (Treasure Nos. 858 and 859) are highly similar to each other in appearance, considering the difference in the arrangement of the chaplets between the two items it is likely that a different mold design was used for each item.

Experimental Study for Confirmation of Relaxation Zone in the Underground Cavity Expansion (지중 내 공동 확장에 따른 이완영역 확인을 위한 실험적 연구)

  • Kim, Youngho;Kim, Hoyeon;Kim, Yeonsam;You, Seung-Kyong;Han, Jung-Geun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.4
    • /
    • pp.231-240
    • /
    • 2017
  • Recently, there have been frequent occurrences of ground sink in the urban area, which have resulted in human and material damage and are accompanied by economic losses. This is caused by artificial factors such as soil loss, poor compaction, horizontal excavation due to the breakage of the aged sewage pipe, and lack of water proof at vertical excavation. The ground sink can be prevented by preliminary restoration and reinforcement through exploration, but it can be considered that it is not suitable for urgent restoration by the existing method. In this study, a model experiment was carried out to simulate the in-ground cavities caused by groundwater flow for developing non-excavation urgent restoration in underground cavity and the range of the relaxation zone was estimated by detecting the around the cavity using a relaxation zone detector. In addition, disturbance region and relaxation region were separated by injecting gypsum into cavity formed in simulated ground. The shape of the underground cavity due to the groundwater flow was similar to that of the failure mode III formed in the dense relative density ground due to water pipe breakage in the previous study. It was confirmed that the relaxed region detected using the relaxation zone detector is formed in an arch shape in the cavity top. The length ratio of the relaxation region to the disturbance region in the upper part of the cavity center is 2: 1, and it can be distinguished by the difference in the decrease of the shear resistance against the external force. In other words, it was confirmed that the secondary damage should not occur in consideration of the expandability of the material used as the injecting material in the pre-repair and reinforcement, and various ground deformation states will be additionally performed through additional experiments.

Changes of Radiation Dose and Image Quality Due to Additional Filtration Material in Computed Radiography (Computed Radiography에서 Additional Filtration Material에 따른 Radiation Dose와 Image Quality의 변화)

  • Kwon, Soon-Mu;Cho, Hyung-Wook;Kang, Yeong-Han;Kim, Boo-Soon;Kim, Jung-Su
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.239-246
    • /
    • 2014
  • Filter absorbs low-energy X-ray to increase the average energy and reduces patient exposure dose. This study investigates if the materials of Mo and W could be used for the digital imaging device CR by conducting image assessment and dose measurement of SNR, FOM and histogram. In addition, measurement of beam quality was conducted depending on the material of the filter, and at the same time, a proper combination of filters was examined depending on the change in tube voltage (kVp). In regard to entrance skin dose, Mo filter showed the dose reduction by 42~56%, compared to Cu filter. Moreover, Mo filter showed higher transmission dose by around 1.5 times than that of Cu filter. In image assessment, it was found that W was unsuitable to be used as a filter, whereas Mo could be used as a filter to reduce dose without decline in image quality at the tube voltage of 80 kVp or higher. As tube voltage increased, 2.0 mm Al+0.1 mm Mo almost had a similar histogram width to that of 2.0 mm Al+0.2 mm Cu. Therefore, Mo filter can be used at relatively high tube voltage of 80 kVp, 100 kVp and 120 kVp. The SNR of 2.0 mm Al+0.1 mm Mo did not show any significant difference from those of 2.0 mm Al+0.2 mm Cu and 2.0 mm Al+0.1 mm Cu. As a result, if Mo filter is used to replace Cu filter in general radiography, where 80 kVp or higher is used for digital radiation image, patient exposure dose can be reduced significantly without decline in image quality, compared to Cu filter. Therefore, it is believed that Mo filter can be applied to chest X-ray and high tube voltage X-ray in actual clinical practice.

Property of tow Shrinkage High Performance Concrete depending on Mixture Proportions and Material Characteristics (배합 및 재료요인에 따른 저수축 고성능 콘크리트의 품질 특성)

  • Han Cheon-Goo;Kim Sung-Wook;Koh Kyoung-Taek;Han Mu-Cheol
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.6 s.84
    • /
    • pp.805-811
    • /
    • 2004
  • In this paper, effects of mixture proportion and material condition on both fundamental properties, drying and autogenous shrinkage of high performance concrete are discussed. According to the results, for the effect of mixture proportion on the fundamental properties, decrease in W/B and unit water content results in reduction of fluidity, while air content has no variation. Compressive strength exhibits an decreasing tendency with an increase in W/B and unit water content do not remarkable affect the compressive strength. For the effect of materials on the fluidity, the fluidity of low heat portland cement(LPC) is smaller than that of ordinary portland cement(OPC). The use of Polycarbonic acid based superplasticizer(PS) has more favorable effect on enhancing fluidity than Naphtalene based superplasticlzer(NS) and Melamine based superplasticizer(MS). Air content of concrete using LPC is larger than that using OPC. The effects of superplasticizer type on the air content is larger in order of MS, PS and NS. The use of LPC exhibited lower strength development at early age than OPC, whereas after 91days, similar level of compressive strength is achieved regardless of cement type. Compressive strength of concrete is not affected by SP type. For the effect of mixture proportion and materials on drying and autogenous shrinkage, an increase in W/B results in reduction of drying shrinkage and an decrease in water content leads to reduce drying shrinkage. Autogenous shrinkage is not observed until 49 days with the concrete mixture with $35\%$ of W/B and $145 kg/m^3$ of water content. This is due to the combination effects of expansion admixture and shrinkage reducing admixture, which causes an offset of autogenous shrinkage. The use of LPC results in a reduction in autogenous shrinkage compared with OPC. SP type has little influence on the autogenous shrinkage. It is found from the results that mixture proportioning of high performance concrete incorporating fly ash, silica fume, expansion admixture and shrinkage reducing admixture is need to focus on the increase in W/B and the reduction in water content and the use of LPC and MS is also required to use to secure the stability against shrinkage properties.

Ultrastructure of the Integument of Capillaria hepatica (syn. Calodium hepatica) (간모세선충(Capillaria hepatica) 표피의 미세구조)

  • Kim, Soo-Jin;Min, Byoung-Hoon;Lee, Haeng-Sook;Lee, Byoung-Wook;Joo, Kyoung-Hwan
    • Applied Microscopy
    • /
    • v.39 no.2
    • /
    • pp.167-173
    • /
    • 2009
  • Capillaria hepatica is a parasitic nematode which causes hepatic capillariasis in rodents and other mammals, including man. Rat species of the genus Rattus are main primary host and rates of genus Rattus of up to 100% have been reported. Infection to reservoir and other mammalian hosts occur incidentally due to ingestion of water or food contaminated with C. hepatica embryonated eggs. The worms mature exclusively inside the liver, but they die and disassemble soon after egg spawning in rats. Dead worms and their eggs cause immune response of focal necrosis and inflammation within the liver. C. hepatica adult with a thin and long body is similar to capillary. The members of Order Trichurida are characterized by having a stichosome and the bacillary bands in front of the body. As already mentioned, the adult C. hepatica residesin the liver, where it deposits groups of eggs, and finally die in the encapsulated tissue of the liver. They produce eggs that elicit a marked granulomatous reaction that eventually destroy the worms. And the adult worms were mixed with eggs. So the complete isolation of the worm and observation of intact ultrastructure is very difficult. In this study, integument structure of C. hepatica isolated from the liver of mouse at 7 weeks after inoculation of embryonated eggs were observed with scanning and transmission electron microscopy. As a results, body length of isolated C. hepatica was about 99 mm. Cuticle, bacillary band and bacillary pore were obtained in the integument of worm. Bacillary pore across cuticular surface of the worm were observed. According to the existence of cap material, external forms of bacillary pore can be divided into three types such as flat, ingression, and ingression with the cap material type. The complete isolation of the worm and observation of ultrastructure of integument will provide the fundamental data which is important in the nematode research including C. hepatica.

A Study on Bismuth tri-iodide for X-ray direct and digital imagers (직접방식 엑스선 검출기를 위한 $BiI_3$ 특성 연구)

  • Lee, S.H.;Kim, Y.S.;Kim, Y.B.;Jung, S.H.;Park, J.K.;Jung, W.B.;Jang, M.Y.;Mun, C.W.;Nam, S.H.
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.27-31
    • /
    • 2009
  • Now a days, the Medical X-ray equipments has become digitalized from analog type such as film, cassette to CR, DR. And many scientists are still researching and developing the Medical X-ray equipment. In this study, we used the Bismuth tri-iodide to conversion material for digital X-ray equipments and we couldn't get the satisfying result than previous study, but it opened new possibility to cover the disadvantage of a-Se is high voltage aplly and difficultness of make. In this paper, we use $BiI_3$ powder(99.99%) as x-ray conversion material and make films that have thickness of 200um and the film size is $3cm{\times}3cm$. Also, we deposited an ITO(Indium Tin Oxide) electrode as top electrode and bottom electrode using a Magnetron Sputtering System. To evaluate a characteristics of the produced films, an electrical and structural properties are performed. Through a SEM analysis, we confirmed a surface and component part. And to analyze the electrical properties, darkcurrent, sensitivity and SNR(Signal to Noise Ratio) are measured. Darkcurrent is $1.6nA/cm^2$ and sensitivity is $0.629nC/cm^2$ and this study shows that the electrical properties of x-ray conversion material that made by screen printing method are similar to PVD method or better than that. This results suggest that $BiI_3$ is suitable for a replacement of a-Se because of the reduced manufacture processing and improved yield.

  • PDF

Evaluation of the Efficiency of the Foxtail Millet Vacuum Cushion in Skin Cancer Radiation Treatment (자체 제작한 Foxtail Millet Vacuum Cushion의 광자선 피부암 치료 시 유용성 검증)

  • Choi, Shin-Cheol;Lee, Kyung-Jae;Jung, Sung-Min;Oh, Tae-Seong;Park, Jong-Il;Shin, Hyun-Kyo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.189-196
    • /
    • 2012
  • Purpose: The sufficiency of skin dose and the reemergence of patient set-up position to the success of skin cancer radiation treatment is a very important element. But the conventional methods to increase the skin dose were used to vacuum cushion, bolus and water tank have several weak points. For this reason, we producted Foxtail Millet Vacuum Cushion and evaluated the efficiency of the Foxtail Millet Vacuum Cushion in skin cancer Radiation treatment. Materials and Methods: We measured absolute dose for 3 materials (Foxtail Millet Vacuum Cushion, bolus and solid water phantom) and compared each dose distribution. We irradiated 6 MV 100 MU photon radiation to every material of 1 cm, 2 cm, 3 cm thickness at three times. We measured absolute dose and compared dose distribution. Finally we inspected the CT simulation and radiation therapy planing using the Foxtail Millet Vacuum Cushion. Results: Absolute dose of Foxtail Millet Vacuum Cushion was similar to absolute dose of bolus and solid water phantom's result in each thickness. it Showed only the difference of 0.1~0.2% between each material. Also the same result in dose distribution comparison. About 97% of the dose distribution was within the margin of error in the prescribed ranges ($100{\pm}3%$), and achieved the enough skin dose (Gross Tumor Volume dose : $100{\pm}5%$) in radiation therapy planing. Conclusion: We evaluated important fact that Foxtail Millet Vacuum Cushion is no shortage of time to replace the soft tissue equivalent material and normal vacuum cushion at the low energy radiation transmittance. Foxtail Millet Vacuum Cushion can simultaneously achieve the enough skin dose in radiation therapy planing with maintaining normal vacuum cushion' function. Therefore as above We think that Foxtail Millet Vacuum Cushion is very useful in skin cancer radiation treatment.

  • PDF