• 제목/요약/키워드: silicone-hydrogel lens

검색결과 27건 처리시간 0.018초

Preparation and Characterization of Ophthalmic Hydrophilic Silicone Lens Containing Zinc Oxide and Iron Oxide Nanoparticles

  • Shin, Su-Mi;Sung, A-Young
    • 한국재료학회지
    • /
    • 제31권8호
    • /
    • pp.427-432
    • /
    • 2021
  • This study uses silicone monomer, DMA, crosslinking agent EGDMA, and initiator AIBN as a basic combination to prepare hydrogel lenses using fluorine-based perfluoro polyether and iron oxide and zinc oxide nanoparticles as additives. After manufacturing the lens using iron oxide nanoparticles and zinc oxide nanoparticles, the optical, physical properties, and polymerization stability are evaluated to investigate the possibility of application as a functional hydrogel lens material. As a result of this experiment, it is found that the addition of the wetting material containing fluorine changes the surface energy of the produced hydrogel lens, thereby improving the wettability. Also, the addition of iron oxide and zinc oxide nanoparticles satisfies the basic hydrogel ophthalmic lens properties and slightly increases the UV blocking performance; it also increases the tensile strength by improving the durability of the hydrogel lens. The polymerization stability of the nanoparticles evaluated through the eluate test is found to be excellent. Therefore, it is judged that these materials can be used in various conditions as high functional hydrogel lens material.

실리콘 하이드로겔 렌즈의 반복적 건조로 인한 렌즈형태 및 자·타각적 증상의 변화 (The Change in the Parameters of Silicone Hydrogel Lens and Objective/Subjective Symptoms induced by Repetitive Dryness of Lens)

  • 김소라;강병호;정인필;박미정
    • 한국안광학회지
    • /
    • 제17권4호
    • /
    • pp.381-388
    • /
    • 2012
  • 목적: 본 연구에서는 반복적인 건조에 의해 유발되는 실리콘 하이드로겔 렌즈의 형태 변화 및 착용시의 자 타각적 증상의 변화에 대해 알아보고자 하였다. 방법: 재질 혹은 두께가 다른 실리콘 하이드로겔 렌즈를 4회씩 건조하고 수화시킨 후 전체 직경과 베이스커브의 변화를 비교하였으며, 건조되었던 실리콘 하이드로겔 렌즈를 착용한 후 착용자의 자각적 증상 및 비침입성 눈물막 파괴시간과 순목횟수를 측정하였다. 결과: 반복되는 건조와 수화로 인하여 모든 실리콘 하이드로겔 렌즈의 전체 직경과 베이스커브가 증가하였다. 전체 직경과 베이스커브가 변하는 정도는 재질에 따라 각기 상이하였으며 두꺼운 렌즈에서는 건조수화 횟수에 따라 불규칙적인 변화가 나타났다. 실리콘 하이드로겔 렌즈의 재질이나 두께에 관계없이 건조수화 과정을 거친 렌즈를 착용하였을 때에는 착용자의 비침입성 눈물막 파괴시간은 감소하였으며, 순목횟수는 증가하였다. 또한, 반복적인 건조수화는 렌즈의 착용감에도 영향을 미쳐 가려움, 통증, 자극감, 이물감, 건조감이 증가하는 경향이 있었다. 결론: 본 연구 결과를 통하여 반복적인 건조수화로 실리콘 하이드로겔 렌즈의 형태 변화 및 이에 따른 착용감 저하 유발을 확인하였으므로 건조한 환경에 대하여 강한 내구성을 가지는 실리콘 하이드로겔 콘택트렌즈의 개발 필요성을 제안할 수 있다.

하이드로겔 렌즈와 실리콘-하이드로겔 렌즈가 각막 두께에 미치는 영향 (Effect of Hydrogel lens and Silicone-Hydrogel lens on Corneal thickness)

  • 서정익
    • 한국임상보건과학회지
    • /
    • 제5권4호
    • /
    • pp.1021-1025
    • /
    • 2017
  • Purpose: Changes in corneal thickness after wearing hydrogel lens and silicone-hydrogel lens with different oxygen transmission rates wew syudied. Methods: Experiments were performed on 11 subjects(22 eyes). corneal thickness was measured after wearing contact lenses for 8 hours. Corneal thickness was measured using ORB Scan II(ver. 3.14) Results: In the results of the corneal thickness measurement by direction, in the case of the hydrogel-tor lens, the center thickness was $33.63{\mu}m$, the nasal was $34.29{\mu}m$, the temporal was $27.17{\mu}m$, the inferior was $27.17{\mu}m$, the superior was $18.90{\mu}m$, and change rates were 6.28%, 5.71%, 5.40%, 4.75% and 3.09%, respectively. In the results of the corneal thickness measurement by diameter, in the case of the hydrogel-tor lens, the center was $33.63{\mu}m$, the mid-peripheral was $28.19{\mu}m$, the peripheral was $24.18{\mu}m$, and change rates were 6.28%, 4.76%, and 3.79%, respectively. Conclusions: The hydrogel lenses with relatively low oxygen transmission rates resulted in a significant increase in thickness over the entire cornea compared to silicon-hydrogel lenses with high oxygen transmission rates.

Preparation and Physical Properties of Silicone Hydrogel Ophthalmic Lens Containing Hydrophilic Monomer

  • Lee, Min-Jae;Sung, A-Young
    • 대한화학회지
    • /
    • 제60권4호
    • /
    • pp.261-266
    • /
    • 2016
  • The major physical characteristics of macromolecules used in silicone hydrogel ophthalmic lenses include optical transmittance, oxygen permeability, water content, and refractive index. For the preparation of highly functional silicone hydrogel lens materials, two silicone monomers were used in the presence of 2-hydroxyethyl methacrylate (HEMA) and hydroxypropyl methacrylate (HPMA). The samples containing HEMA and HPMA had oxygen transmissibility (Dk) values in the range of 73.38–50.98 × 10-11 (cm2/s) (mLO2/mL×mmHg) and 71.94–42.80 × 10-11 (cm2/s) (mLO2/mL×mmHg), respectively. Furthermore, the water contents of samples containing HEMA and HPMA were in the range of 32.73–34.67% and 31.94–33.74%, respectively, and the refractive indices were in the range of 1.4348–1.4364 and 1.4385–1.4407, respectively. Thus, silicone monomers containing HEMA and HPMA are expected to be useful for fabricating high-oxygen-permeability silicon hydrogel ophthalmic lenses.

역방향으로 착용한 (inside out or everted) 실리콘 하이드로겔 렌즈가 각막형상 변화에 미치는 영향 (Effect of Everted(inside out) Silicone Hydrogel Lens on Corneal Topographical Changes)

  • 김수현;정주현
    • 한국안광학회지
    • /
    • 제17권4호
    • /
    • pp.389-394
    • /
    • 2012
  • 목적: 본 연구는 역방향(inside out or everted)으로 착용한 실리콘 하이드로겔렌즈가 각막 형상변화에 미치는 영향을 알아보기 위해 실시하였다. 방법: 역방향 실리콘 하이드로겔 렌즈의 형상과 플루오레신 패턴을 알아보고 이를 수면 중 8시간 이상 착용하여 타각적 굴절이상도와 각막지형도의 변화를 관찰하였다. 검사는 렌즈 착용 전, 렌즈 착용 후 1일, 2일, 3일, 5일, 7일 후에 시행하였으며 렌즈의 착용을 중지한 후 1일, 2일, 3일, 4일 후에 동일하게 시행하였다. 결과: 역방향 실리콘 하이드로겔 렌즈 착용 후 피팅패턴을 검사한 결과 역기하렌즈와 유사한 눌림이 있었다. 타각적 굴절이상도의 근시도와 각막 굴절력이 감소하였으며 각막지형도의 변화를 보였고 이는 렌즈 착용 중지 후 4일 동안 대부분 회복되었다. 렌즈를 뒤집어 착용하는 것에 대한 불편함은 크게 없는 것으로 나타났다. 결론: 역방향으로 착용한 실리콘 하이드로겔 렌즈의 수면 중 착용(Overnight wear)을 통하여 각막지형도상의 유의한 차이를 야기하였다. 추후 각막의 형상변화(reshaping)를 위해 실리콘 하이드로겔 렌즈의 사용이 가능할 것으로 보고, 교정효과에 대해 예측이 가능(predictable)하고 효과적인(effective) 방법을 개발하기 위해 여러 변수를 확인해야 할 것으로 생각된다.

Analysis of Physical Properties of Hydrogel Lenses Polymer Containing Styrene and PVP

  • Lee, Min-Jae;Sung, A-Young
    • 한국재료학회지
    • /
    • 제29권7호
    • /
    • pp.399-407
    • /
    • 2019
  • This research is carried out to analyze the effects of Styrene and PVP on the properties of silicone hydrogel lenses. Styrene group and PVP(Polyvinylpyrrolidone) are used as additives for a basic combination containing silicone monomer, TSMA(trimethylsilyl methacrylate) and DMA(n,n-dimethylacrylamide) added to the mix at ratios of 1~10 %. Silicone hydrogel lens is produced by cast-mold method. The polymerized lens sample is hydrated in a 0.9 % saline solution for 24 hours before its optical and physical characteristics are measured. Measurement of the physical characteristics of the produced material shows that the refractive index is 1.3682~1.4321, water content 77.11~45.73 %, visible light transmittance 95.14~88.20 %, and tensile strength 0.0652~0.3113 kgf. The results show a decrease of refractive index as the ratio of additives and water content decreases. The result of the stabilization test of polymerization show an increase of extractables along with increase of the ratio of additives, but the difference is not significant for all samples, so it can be judged that the stabilization of the polymer is maintained. Therefore, the additions of styrene and PVP should be taken into consideration for their effects on the physical properties of silicone hydrogel lens.

콘택트렌즈의 재질별 각막부종의 비교 (Comparison of Corneal Edema Induced by Material of Contact Lens)

  • 김기성;김선경;김태훈;김효진
    • 한국안광학회지
    • /
    • 제20권2호
    • /
    • pp.151-156
    • /
    • 2015
  • 목적: 콘택트렌즈를 권장착용시간 동안 착용한 후에 렌즈의 재질에 따라 발생하는 각막부종의 정도를 비교해 보고자 한다. 방법: 안질환이나 약물사용이 없는 성인남녀 43명 77안을 대상으로 하였다. Narafilcon A, HEMA, 실리콘 하이드로젤 재질의 정기교체형 렌즈 3종의 렌즈를 사용하였다. 중심각막두께는 Pentacam을 사용하여 렌즈 착용 전과 8시간 착용 후를 측정하였다. 착용 전과 후의 차이 값으로 각막부종의 정도를 판단하였다. 결과: Narafilcon A, HEMA 재질의 렌즈, 실리콘 하이드로젤 재질의 정기교체형 렌즈의 평균 각막부종은 각각 $2.36{\pm}6.15{\mu}m(Mean{\pm}SD)$, $23.61{\pm}10.71{\mu}m$, $18.25{\pm}8.64{\mu}m$였다. Narafilcon A를 착용한 뒤 측정된 중심각막두께는 착용 전 측정한 중심각막두께와 통계적으로 유의한 차이가 없었다. HEMA와 실리콘 하이드로젤 재질의 렌즈에서 착용 후에 유발된 각막부종은 그 정도에 있어 narafilcon A와 통계적으로 유의한 차이가 있었다. 결론: 정기교체형 실리콘 하이드로젤 재질 렌즈에서 유발된 각막부종의 양은 HEMA 재질의 렌즈에서 유발된 각막부종의 양과 통계적으로 유의한 차이가 없었지만 narafilcon A와는 유의한 차이가 있었다. 따라서 콘택트렌즈 재료의 조성에 따라 권장착용시간을 초과하지 않도록 주의해야 할 것으로 판단된다.

표면 오염시 소프트콘택트렌즈의 재질에 따른 가시광선투과도 및 표면 변화 (Changes in Optical and Surface Properties of Contaminated Soft Contact Lenses)

  • 김정은;정보영;노혜란
    • 한국안광학회지
    • /
    • 제17권1호
    • /
    • pp.83-89
    • /
    • 2012
  • 목적: 본 연구는 아이메이크업에 침지된 소프트콘택트렌즈의 가시광선투과도와 표면 변화를 알아보고자 하였다. 방법: 눈 화장에 사용되는 4가지 종류의 아이메이크업에 침지된 시간에 따라 etafilcon A(이하 HEMA를 기초로 한 하이드로겔 제품)렌즈와 lotrafilcon B(이하 실리콘을 기초로 한 하이드로겔 제품)렌즈의 가시광선투과도 변화를 알아보았다. 1주일간 지속적으로 아이메이크업에 침지된 렌즈를 다목적용액(MPS)을 이용한 세척 후 가시광선 투과도 및 표면 변화를 알아보았다. 결과: 각각의 렌즈를 아이메이크업에 침지시켰을 때 30분 후의 가시광선 투과도는 평균 93.4%(HEMA를 기초로 한 하이드로겔 제품), 90.0%(실리콘을 기초로 한 하이드로겔 제품)로 각각의 대조군의 가시광선투과도(97.8%, 96.4%)와 비교하여 감소하였다. 1주일간 지속적으로 가루 아이섀도우와 마스카라에 침지된 렌즈는 모두 세척 후에도 부착된 아이메이크업 잔여물이 완전하게 제거 되지 않았다. 특히, silicone 계열의 렌즈에서 잔여물이 많은 것으로 나타났는데, 이는 감소된 가시광선 투과도 및 주사전자현미경을 통한 표면 결과로 확인할 수 있었다. 결론: 아이메이크업에 침지된 콘택트렌즈의 경우 렌즈의 소재와 아이메이크업의 소재에 따라 일반적인 세척방법으로는 아이메이크업이 제거되지 않았고 이는 렌즈 표면의 변화와 렌즈의 가시광선 투과도 저하로 나타났다.

Preparation and Analysis of High Functional Silicone Hydrogel Lens Containing Metal Oxide Nanoparticles by Photopolymerizaion

  • Heo, Ji-Won;Sung, A-Young
    • 한국재료학회지
    • /
    • 제32권4호
    • /
    • pp.193-199
    • /
    • 2022
  • In this study, lenses are fabricated using various nanomaterials as additives to a silicone polymer made with an optimum mixing ratio and short polymerization time. In addition, PVP is added at a ratio of 1 % to investigate the physical properties according to the degree of dispersion, and the compatibility with hydrophobic silicone and the possibility of application as a functional lens material are confirmed. The main materials are SIU as a silicone monomer, DMA, a hydrophilic copolymer, EGDMA as a crosslinking agent, and 2H2M as a photoinitiator. Holmium (III) oxide, Europium (III) oxide, aluminum oxide, and PVP are used. When Holmium (III) oxide and Europium (III) oxide are added based on the Ref sample, the characteristics of the lens tend to be similar overall, and the aluminum oxide shows a tendency slightly different from the previous two oxides. This material can be used as a silicone lens material with various nano oxides and polyvinylpyrrolidone (PVP) acting as a dispersant.

매일착용 실리콘 하이드로겔렌즈로 바꿔 착용한 소프트 콘택트렌즈 착용자에서 나타난 증상 변화 (Changes in Objective and Subjective Responses in Soft Contact Lens Wearers Refitted to Daily-Wear Silicone Hydrogel Contact Lenses)

  • 이군자;문미영;변장원;임현성
    • 한국안광학회지
    • /
    • 제12권4호
    • /
    • pp.43-54
    • /
    • 2007
  • 계속 착용렌즈(continuous wear lens)로 개발된 실리콘 하이드로겔렌즈가 최근에는 매일 착용렌즈로 사용되고 있다. 본 연구에서는 소프트 콘택트렌즈를 성공적으로 수년 동안 착용한 성인을 대상으로 매일 착용렌즈로 개발된 $O_2OPTIX$ 실리콘 하이드로겔렌즈를 바꿔 착용시킨 후 나타나는 임상 증상의 변화를 비교 분석하였다. $O_2OPTIX$ 실리콘 하이드로겔렌즈로 바꿔 착용한 소프트 콘택트렌즈 착용자 65명 중 62명(평균 착용기간: $30.7{\pm}19.9$개월)이 마지막까지 연구에 참여하였으며 렌즈 착용 기간 중 연구 대상자에서 나타나는 자각적 증상과 타각적 증상을 CCLRU 기준에 따라 평가하였다. 단일커브의 O2OPTIX 실리콘 하이드로겔렌즈를 피팅한 결과 피팅 성공률은 98%로 나타났고 착용하던 소프트 콘택트렌즈보다 추가 교정도수가 필요한 경우는 33.9%로 나타났다. 대부분의 착용자는 전에 착용하던 소프트 콘택트렌즈보다 건조감과 충혈, 피곤함이 모두 줄었다고 응답했으며 자각적증상과 타각적증상 중 건조감, 피곤함, 가려움증, 구결막 충혈 및 윤부 충혈은 모두 감소했으며(p<0.0001) 특히 소프트 콘택트렌즈 착용 중 증상을 많이 느꼈던 착용자에서 증상이 더 많이 개선되었다. 그러나 각막 염색 증상은 많은 착용자에서 관찰되었고 정도도 심해졌다(p<0.0001). 소프트 콘택트렌즈 착용자가 실리콘 하이드로겔렌즈로 바꿔 착용하면 건조감과충혈 및 피곤함의 증상이 해결될 수 있을 것으로 사료되며 특히 소프트 콘택트렌즈를 착용하는 동안 증상을 심하게 느낀 사람에서 더 효과적일 것으로 생각된다. 소프트 콘택트렌즈 착용자가 실리콘 하이드로겔렌즈로 바꿔 착용하는 경우 각막염색이 발생될 수 있으므로 지속적인 관찰이 요망되며 최대교정시력을 제공하기 위해서는 피팅 후 반드시 덧댐굴절검사(over-refraction)가 필요할 것으로 생각된다.

  • PDF