Developing an On-Line Monitoring System for a Forest Hydrological Environment - Development of Hardware - (산림수문환경(山林水文環境) 모니터링을 위(爲)한 원거리(遠距離) 자동관측(自動觀測)시스템의 개발(開發) - 하드웨어를 중심(中心)으로 -)

  • Lee, Heon Ho;Suk, Soo Il
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.3
    • /
    • pp.405-413
    • /
    • 2000
  • This study was conducted to develop an on-line monitoring system for a forest hydrological environment and its meteorological condition, such as temperature, wind direction and speed, rainfall and water level on V-notch, electrical conductivity(EC), potential of hydrogen(PH) by the motor drive sensor unit and measurement with a single-chip microprocessor as controller. These results are summarized as follows ; 1. The monitoring system consists of a signal process unit, motor drive sensor unit, radio modem unit and power supply. 2. The motor drive sensor unit protects the sensor from swift current or freezing and can constantly maintain fixed water level during measurements. 3. This monitoring system can transfer the data by radio modem. Additionally, this system can monitor hydrological conditions in real time. 4. The hardware was made of several modules with an independent CPU. They can be mounted, removed, repaired and added to. Their function can be changed and expanded. 5. These are the result of an accuracy test, the values of temperature, EC and pH measured within an error range of ${\pm}0.2^{\circ}C$, ${\pm}1{\mu}S$ and ${\pm}0.1pH$ respectively. 6. This monitoring system proved to be able to measure various factors for a forest hydrological environment in various experimental stations.

  • PDF

Analysis of the ESD and DAP According to the Change of the Cine Imaging Condition of Coronary Angiography and Usefulness of SNR and CNR of the Images: Focusing on the Change of Tube Current (관상동맥 조영술(Coronary Angiography)의 씨네(cine) 촬영조건 변화에 따른 입사표면선량(ESD)과 흡수선량(DAP) 및 영상의 SNR·CNR 유용성 분석: 관전류 변화를 중점으로)

  • Seo, Young Hyun;Song, Jong Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.371-379
    • /
    • 2019
  • The purpose of this study was to investigate the effect of the change in the X-ray condition on the entrance surface dose (ESD) and dose area product (DAP) in the cine imaging of coronary angiography (CAG), and to analyze the usefulness of the condition change on the dose relation and image quality by measuring and analyzing the Signal to Noise Radio (SNR) and Contrast to Nois Ratio (CNR) of the angiographic images taken by the Image J program. Data were collected from 33 patients (24 males and 9 females) who underwent CAG at this hospital from November 2017 to March 2018. In terms of imaging condition and data acquisition, the ESD and DAP of group A with a high tube current of 397.2 mA and group B with a low tube current of 370.7 mA were retrospectively obtained for comparison and analysis. For the SNR and CNR measurement and analysis via Image J, the result values were derived by substituting the obtained data into the formula. The correlations among ESD and DAP according to the change in the imaging condition, SNR, and CNR were analyzed by using the SPSS statistical analysis software. The relationships of groups A and B, having a difference in the imaging condition, mA, with ESD ($A:483.5{\pm}60.1$; $B: 464.4{\pm}39.9$) and DAP ($A:84.3{\pm}10.7$; $B:81.5{\pm}7$) were not statistically significant (p>0.05). In the relationships with SNR and CNR based on Image J, the SNR ($5.451{\pm}0.529$) and CNR ($0.411{\pm}0.0432$) of the images obtained via the left coronary artery (LCA) imaging of group B showed differences of $0.475{\pm}0.096$ and $-0.048{\pm}0.0$, respectively, from the SNR ($4.976{\pm}0.433$) and CNR ($0.459{\pm}0.0431$) of the LCA of group A. However, the differences were not statistically significant (p<0.05). In the SNR and CNR obtained via the right coronary artery (RCA) imaging, the SNR ($4.731{\pm}0.773$) and CNR ($0.354{\pm}0.083$) of group A showed increased values of $1.491{\pm}0.405$ and $0.188{\pm}0.005$, respectively, from the SNR ($3.24{\pm}0.368$) and CNR ($0.166{\pm}0.033$) of group B. Among these, CNR was statistically significant (p<0.05). In the correlation analysis, statistically significant results were shown in SNR (LCA) and CNR (LCA); SNR (RCA) and CNR (RCA); ESD and DAP; ESD and sec; DAP and CNR (RCA); and DAP and sec (p<0.05). As a result of the analyses on the image quality evaluation and usefulness of the dose change, the SNR and CNR were increased in the RCA images of the CAG obtained by increasing the mA. Based on the result that CNR showed a statistically significant difference, it is believed that the contrast in the image quality can be further improved by increasing the mA in RCA imaging.

Optimization of Subtraction Brain Perfusion SPECT with Basal/Acetazolamide Consecutive Acquisition (기저/아세타졸아미드 부하 연속 촬영 뇌관류 SPECT 최적화)

  • Lee, Dong-Soo;Lee, Tae-Hoon;Kim, Kyeong-Min;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.330-338
    • /
    • 1997
  • This study investigated the method to adjust acquisition time(a) and injection dose (i) to make the best basal and subtraction images in consecutive SPECT. Image quality was assumed to be mainly affected by signal to noise ratio(S/N). Basal image was subtracted from the second image consecutively acquired at the same position. We calculated S/N ratio in basal SPECT images($S_1/N_1$) and subtraction SPECT images(Ss/Ns) to find a(time) and i(dose) to maximize S/N of both images at the same time. From phantom images, we drew the relation of image counts and a(time) and i(dose) in our system using fanbeam-high-resolution collimated triple head SPECT. Noise by imaging process depended on Poisson distribution. We took maximum tolerable duration of consecutive acquisition as 30 minutes and maximum injectible dose as 1,850MBq(50 mCi)(sum of two injections) per study. Counts of second-acquired image($S_2$), counts($S_s$) and noise($N_s$) of subtraction SPECT were as follows. $C_1$ was the coefficient of measurement with our system. $$S_2=S_1{\cdot}(\frac{30-a}{a})+background{\cdot}(1-\frac{30-a}{a})+C_1{\cdot}(30-a){\cdot}{\epsilon}{\cdot}(50-i)$$ $$Ss=S_2-\{S_1{\cdot}(\frac{30-a}{a})+background{\cdot}(1-\frac{(30-a)}{a})\}$$ $$Ns={\sqrt{N_2^2+N_1^2{\cdot}\frac{(30-a)^2}{a^2}}={\sqrt{S_2+S_1{\cdot}\frac{(30-a)^2}{a^2}}$$ In case of rest/acetazolamide study, effect(${\epsilon}$) of acetazolamide to increase global brain uptake of Tc-99m-HMPAO could be 1.5 or less. Varying ${\epsilon}$ from 1 to 1.5, a(time) and i(dose) pair to maximize both $S_1/N_l$ and Ss/Ns was determined. 15 mCi/17 min and 35mCi/13min was the best a(time) and i(dose) pair for rest/acetazolamide study(when ${\epsilon}$ were 1.2) and came to be used for our clinical routine after this study. We developed simple method to maximize S/N ratios of basal and subtraction SPECT from consecutive acquisition. This method could be applied to ECD/HMPAO and brain activation studies as well as rest/acetazolamide studies.

  • PDF

Fabrication of Strain Sensor Based on Graphene/Polyurethane Nanoweb and Respiration Measurement (그래핀/폴리우레탄 나노웹 기반의 스트레인센서 제작 및 호흡측정)

  • Lee, Hyocheol;Cho, Hyeon-seon;Lee, Eugene;Jang, Eunji;Cho, Gilsoo
    • Science of Emotion and Sensibility
    • /
    • v.22 no.1
    • /
    • pp.15-22
    • /
    • 2019
  • The purpose of this study is to develop a strain sensor based on a nanoweb by applying electrical conductivity to a polyurethane nanoweb through the use of Graphene. For this purpose, 1% Graphene ink was pour-coated on a polyurethane nanoweb and post-treated with PDMS (Polydimethylsiloxane) to complete a wearable strain sensor. The surface characteristics of the specimens were evaluated using a field emission scanning electron microscope (FE-SEM) to check whether the conductive material was well coated on the surface of the specimen. Electrical properties of the specimens were measured by using a multimeter to measure the linear resistance of the specimen and comparing how the line resistance changes when 5% and 10% of the specimens are tensioned, respectively. In order to evaluate the performance of the specimen, the gauge factor was obtained. The evaluation of the clothing was performed by attaching the completed strain sensor to the dummy and measuring the respiration signal according to the tension using MP150 (Biopac system Inc., USA) and Acqknowledge (ver. 4.2, Biopac system Inc., U.S.A.). As a result of the evaluation of the surface characteristics, it was confirmed that all the conductive nanoweb specimen were uniformly coated with the Graphen ink. As a result of measuring the resistance value according to the tensile strength, the specimen G, which was treated with just graphene had the lowest resistance value, the specimen G-H had the highest resistance value, and the change of the line resistance value of the specimen G and the specimen G-H is increased to 5% It is found that it increases steadily. Unlike the resistance value results, specimen G showed a higher gauge rate than specimen G-H. As a result of evaluation of the actual clothes, the strain sensor made using the specimen G-H measured the stable peak value and obtained a signal of good quality. Therefore, we confirmed that the polyurethane nanoweb treated with Graphene ink plays a role as a breathing sensor.

Steel Plate Faults Diagnosis with S-MTS (S-MTS를 이용한 강판의 표면 결함 진단)

  • Kim, Joon-Young;Cha, Jae-Min;Shin, Junguk;Yeom, Choongsub
    • Journal of Intelligence and Information Systems
    • /
    • v.23 no.1
    • /
    • pp.47-67
    • /
    • 2017
  • Steel plate faults is one of important factors to affect the quality and price of the steel plates. So far many steelmakers generally have used visual inspection method that could be based on an inspector's intuition or experience. Specifically, the inspector checks the steel plate faults by looking the surface of the steel plates. However, the accuracy of this method is critically low that it can cause errors above 30% in judgment. Therefore, accurate steel plate faults diagnosis system has been continuously required in the industry. In order to meet the needs, this study proposed a new steel plate faults diagnosis system using Simultaneous MTS (S-MTS), which is an advanced Mahalanobis Taguchi System (MTS) algorithm, to classify various surface defects of the steel plates. MTS has generally been used to solve binary classification problems in various fields, but MTS was not used for multiclass classification due to its low accuracy. The reason is that only one mahalanobis space is established in the MTS. In contrast, S-MTS is suitable for multi-class classification. That is, S-MTS establishes individual mahalanobis space for each class. 'Simultaneous' implies comparing mahalanobis distances at the same time. The proposed steel plate faults diagnosis system was developed in four main stages. In the first stage, after various reference groups and related variables are defined, data of the steel plate faults is collected and used to establish the individual mahalanobis space per the reference groups and construct the full measurement scale. In the second stage, the mahalanobis distances of test groups is calculated based on the established mahalanobis spaces of the reference groups. Then, appropriateness of the spaces is verified by examining the separability of the mahalanobis diatances. In the third stage, orthogonal arrays and Signal-to-Noise (SN) ratio of dynamic type are applied for variable optimization. Also, Overall SN ratio gain is derived from the SN ratio and SN ratio gain. If the derived overall SN ratio gain is negative, it means that the variable should be removed. However, the variable with the positive gain may be considered as worth keeping. Finally, in the fourth stage, the measurement scale that is composed of selected useful variables is reconstructed. Next, an experimental test should be implemented to verify the ability of multi-class classification and thus the accuracy of the classification is acquired. If the accuracy is acceptable, this diagnosis system can be used for future applications. Also, this study compared the accuracy of the proposed steel plate faults diagnosis system with that of other popular classification algorithms including Decision Tree, Multi Perception Neural Network (MLPNN), Logistic Regression (LR), Support Vector Machine (SVM), Tree Bagger Random Forest, Grid Search (GS), Genetic Algorithm (GA) and Particle Swarm Optimization (PSO). The steel plates faults dataset used in the study is taken from the University of California at Irvine (UCI) machine learning repository. As a result, the proposed steel plate faults diagnosis system based on S-MTS shows 90.79% of classification accuracy. The accuracy of the proposed diagnosis system is 6-27% higher than MLPNN, LR, GS, GA and PSO. Based on the fact that the accuracy of commercial systems is only about 75-80%, it means that the proposed system has enough classification performance to be applied in the industry. In addition, the proposed system can reduce the number of measurement sensors that are installed in the fields because of variable optimization process. These results show that the proposed system not only can have a good ability on the steel plate faults diagnosis but also reduce operation and maintenance cost. For our future work, it will be applied in the fields to validate actual effectiveness of the proposed system and plan to improve the accuracy based on the results.

Dosimetric Characterization of an Ion Chamber Matrix for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료 선량분포 확인을 위한 2차원적 이온전리함 배열의 특성분석)

  • Lee, Jeong-Woo;Hong, Se-Mie;Kim, Yon-Lae;Choi, Kyoung-Sik;Jung, Jin-Beom;Lee, Doo-Hyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.131-135
    • /
    • 2006
  • A commercial ion chamber matrix was examined the characteristics and its performance for radiotherapy qualify assurance. The device was the I'mRT 2D-MatriXX (Scanditronix-Wellhofer, Schwarzenbruck, Germany). The 2D-MatriXX device consists of a 1020 vented ion chamber array, arranged in $24{\times}24cm^2$ matrix. Each ion chamber has a volume of $0.08cm^3$, spacing of 0.762 cm and minimum sampling time of 20 ms. For the investigation of the characteristics, dose linearity, output factor, short-term reproducibility and dose rate dependency were tested. In the testing of dose linearity. It has shown a good signal linearity within 1% in the range of $1{\sim}800$cGy. Dose rate dependency was found to be lower than 0.4% (Range: 100-600 Mu/min) relative to a dose rate of 300 Mu/min as a reference. Output factors matched very well within 0.5% compared with commissioned beam data using a ionization chamber (CC01, Scanditronix-Wellhofer, Schwarzenbruck, Germany) in the range of field sizes $3{\times}3{\sim}24{\times}24cm^2$. Short-term reproducibility (6 times with a interval of 15 minute) was also shown a good agreement within 0.5%, when the temperature and the pressure were corrected by each time of measurement. in addition, we compared enhanced dynamic wedge (EDW, Varian, Palo Alto, USA) profiles from calculated values in the radiation planning system with those from measurements of the MatriXX. Furthermore, anon-uniform IMRT dose fluence was tested. All the comparison studies have shown good agreements. In this study, the MatriXX was evaluated as a reliable dosimeter, and it could be used as a simplistic and convenient tool for radiotherapy qualify assurance.

  • PDF