• Title/Summary/Keyword: signal head

Search Result 414, Processing Time 0.024 seconds

Comparison of Measurement Methods for Head-related Transfer Function(HRTF) (머리전달함수 측정법의 실험적 비교)

  • Ahn, Tae-Soo;Lee, Doo-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.12
    • /
    • pp.1260-1268
    • /
    • 2009
  • Three methods(the stepped sine method, the statistical method(random excitation method) and the maximum-length sequence(MLS) method) for head-related transfer functions(HRTFs) are experimentally compared in view point of accuracy and efficiency. First, the stepped sine method has high signal-to-noise ratio, but low efficiency. Second, the statistical method is fast measurement speed, but weak to noise than the other methods. Finally, the MLS method shows both good efficiency and high signal-to-noise ratio, but it needs additional software or equipment such as MLS signal generator. For comparison of measurement accuracy, HRTFs of KEMAR dummy are measured for various azimuths and elevations. Error norms for magnitude and phase of HRTFs are defined and calculated for the measured HRTFs. The calculated error norms show that the methods give similar results in magnitude and phase except a little phase difference in the MLS method.

A Study on mobile based EEG display and device development (모바일기반으로한 EEG표시 및 장치개발에 관한 연구)

  • Lee, Chung-Heon;Kim, Gyu-Dong;Hong, Jun-Eui;Kwon, Jang-Woo;Lee, Dong-Hoon
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.145-147
    • /
    • 2009
  • This research measures EEG signals which are generating on head skin and extracts brain concentration level related with brain activity. We have developed concentration wireless transmission system by displaying this EEG signal on PDA mobile device. The front head was used for measuring EEG signal and INA128 with TL084 and analog elements was used for measuring EEG signal, amplifying and filtering the signal. Measured analog EEG signals changed into digital signals by using ADC of PIC24FJ192 with 10bit resolution and 500Ks/s sampling rate. So The changed digital signals have transmitted to the PDA by using bluetooth. LabView 8.5 was also used for FFT transformation, frequency and spectrum analysis of the transferred EEG signal. As a result, $\alpha$ wave, $\beta$ wave, $\theta$ wave and $\delta$ wave were classified. we extracted the concentration index by adapting concentration extraction algorithm. This concentration index was transferred into PDA by wireless module and displaying.

  • PDF

Effects of Disk Thickness and Pemto Slider on Position Error Signal for High TPI Hard Disk Drive (고밀도 디스크 드라이브를 위한 디스크 두께와 Pemto 슬라이더가 PES에 미치는 영향)

  • Han Yun-Sik;Lee Ho Seong;Song Yong-Han
    • Transactions of the Society of Information Storage Systems
    • /
    • v.1 no.1
    • /
    • pp.23-28
    • /
    • 2005
  • This paper investigates the effects of disk thickness and Pemto slider on PES(position error signal) for high TPI(track per inch) drives above 150kTPI at early stage of their development. In order to reduce the disk flutter which becomes a dominant contributor to the TMR, the thicker disks with both 63 and 69mi1 have been used. Also, PES of a Pemto slider with thinner thickness than Pico slider has been estimated to decrease the conversion factor of disk motion in axial direction to head off-track motion. A frequency-domain PES estimation and prediction tool has been developed via measurement of disk flutter and HSA(head stack assembly) forced vibration. It has been validated by the measured PES in drive level. Based on the model and measurement of disk flutter, PES of a drive with the thicker disk and Pemto slider is predicted and their impact is investigated.

  • PDF

A Simulation of the Railway Signal System Using Pattern Control Technique to Upgrade the Railway Efficiency (선로효율 향상을 위한 열차 패턴제어방식의 신호보안시스템 시뮬레이션)

  • 강규현;김희식
    • Journal of the Korea Society for Simulation
    • /
    • v.7 no.2
    • /
    • pp.125-136
    • /
    • 1998
  • To upgrade railway traffic density without any change of signal block length between stations on existing railway lines, a new signalling system of train control "the pattern control technique" is suggested. It needs very little change to computerize the cab signal using transponders. A computer simulation system is developed to experiment the new control method. The new signalling system shows much increase of the railway traffic efficiency. The train head-way time by the fixed signalling system and the new pattern control system is analyzed. The pattern control technique shows 35% increasement of trair operation under same condition of railway and trains.nd trains.

  • PDF

A Study on Indirect Attachment Method of Compensation Materials to Increase Signal Intensity in Magnetic Resonance Imaging (자기공명영상검사 시 신호강도를 높이기 위한 보상물질의 간접부착 방식에 관한 연구)

  • Son, Soon-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.7
    • /
    • pp.437-442
    • /
    • 2017
  • Previously, studies on compensation material to increase the signal intensity have been conducted which does not affect the reading of images. However, the compensation material has a concern on patient infection as it is attached directly on the skin. Therefore, in this study, we tested an indirect attachment of the compensation material as an alternative method of the direct attachment. The silicon compensation material was fabricated in the form of a cylindrical bar and attached to each element of the 8 channel head coil. Then the signal intensities of the water phantom pre and post application of the silicon were measured. T1 and T2-weighted images were acquired using an 8-channel head coil and a 3.0T superconducting MRI. Signal intensities were measured by using an image measuring program. Paired t-test was used to verify if there were significant differences. The signal intensity before application of the silicon was significantly increased by 3.39% and 2.62% in T1 and T2 weighted images, respectively. Although the indirect attachment method had a limitation to completely replace the existing method, it was considered to be useful in patients with infectious diseases such as diabetic complications since it had a meaningful improvement in signal intensity based on the filling factor increase.

Combustion Condition Monitoring of the Marine Diesel Engine using Acceleration Signal of Cylinder Head (실린더 헤더의 가속도 신호를 이용한 선박용 디젤엔진의 연소 상태 모니터링)

  • Seo, Jong-Cheol;Kim, Sang-Hwan;Lee, Don-Chool
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.607-610
    • /
    • 2009
  • The abnormal combustion in the running engine results to knocking which increases the pressure and temperature in the cylinder, thereby decreasing the generated power by reducing the thermal efficiency. When the temperature and pressure in the cylinder increased rapidly by knocking, abnormal combustion takes place and the engine power is decreased. To investigate the knocking phenomenon, accelerometers are installed in the cylinder head to monitor and diagnose the vibration signal. As method of signal analysis, the time-frequency analysis method was adapted for acquisition of vibration signal and analyzes engine combustion in the short time. In this experiment, after analyzing time data which is stored in the signal recorder in one unit work (4 strokes: 2 revolutions), the signal with frequency and Wavelet methods with extracted one engine combustion data was also analyzed. Then, normal condition with no knocking signal is analyzed at this time. Hereafter, the experiments made a standard for distinguishing normal and abnormal condition to be carried out in acquisition of vibration signal at all cylinders and extracting knocking signal. In addition, analyzing methods can be diverse with Symmetry Dot Patterns (SDP), Time Synchronous Average (TSA), Wigner-Ville Distribution (WVD), Wigner-Ville Spectrum (WVS) and Mean Instantaneous Power (MIP) in the cold test [2]. With signal processing of vibration from engine knocking sensor, the authors adapted a part of engine /rotor vibration analysis and monitoring system for marine vessels to prevent several problems due to engine knocking

  • PDF

Settling time of dental x-ray tube head after positioning (치과용 X-선 관구의 조정시간)

  • Yoon Suk-Ja;Kang Byung-Cheol;Wang Se-Myung;Koh Chang-Sung
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.159-165
    • /
    • 2002
  • Purpose: The aim of this study was to introduce a method of obtaining the oscillation graphs of the dental x-ray tube heads relative to time using an accelerometer. Materials and Methods: An Accelerometer, Piezotron type 8704B25 (Kistler Instrument Co., Amherst, NY, USA) was utilized to measure the horizontal oscillation of the x-ray tube head immediately after positioning the tube head for an intraoral radiograph. The signal from the sensor was transferred to a dynamic signal analyzer, which displayed the magnitude of the acceleration on the Y-axis and time lapse on the X -axis. The horizontal oscillation of the tube head was measured relative to time, and the settling time was also determined on the basis of the acceleration graphs for 6 wall type, 5 floor-fixed type, and 4 mobile type dental x-ray machines. Results : The oscillation graphs showed that tube head movement decreased rapidly over time. The settling time varied with x-ray machine types. Wall-type x-ray machines had a settling time of up to 6 seconds, 5 seconds for fixed floor-types, and 1 I seconds for the mobile-types. Conclusion: Using an accelerometer, we obtained the oscillation graphs of the dental x-ray tube head relative to time. The oscillation graph with time can guide the operator to decide upon the optimum exposure moment after x-ray tube head positioning for better radiographic resolution.

  • PDF

Effects of Head-Up Tilt on Nonlinear Properties of Heart Rate Variability in Young and Elderly Subjects

  • Jin, Seung-Hyun;Kim, Wuon-Shik;No, Ki-Yong
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.3 no.1
    • /
    • pp.14-22
    • /
    • 2005
  • In the present study, our aim is to investigate whether responses to the head-up tilt (HUT) on nonlinear properties of heart rate variability (HRV) in young and elderly subjects are different or not. Thirteen young-healthy subjects ($24.5{\pm}3.7$ years) and 18 old-aged healthy subjects ($74.5{\pm}7.4$ years) participated in this study. An electrocardiogram (ECG) in the supine posture, at $0^{\circ}$, and in the standing posture, at $70^{\circ}$ of head-up tilt, was recorded. Detrended fluctuation analysis (DFA) and approximate entropy (ApEn), measures of short-/long-term correlation properties and overall complexity of heart rate (HR) respectively, along with spectral components of HR variability (HRV) were analyzed for both the supine and HUT postures. We observed that the short-term fractal exponent ${\alpha}_1$ increased during HUT posture (F(1, 29) = 39.79, P = 0.000), especially, the young subjects showed a significantly higher values compared to the elderly subjects. ApEn significantly decreased (F(1, 29) = 8.61, P = 0.006) during HUT posture. HUT posture decreased the complexity in HR dynamics and increased short-term fractal exponent values in young subjects but not in elderly subjects. These results imply that there are differences of response to HUT on nonlinear properties between young and elderly subjects.

  • PDF

The Methods Of Synthesis And Matched Processing The Normal System Of Orthogonal Circle M-Invariant Signal

  • Inh Tran Due
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.897-899
    • /
    • 2004
  • There is scientific work containing the recurrence method of synthesis the new class of orthogonal circle m-invariant signals: designed effective algorithms of fast-direct computing m-convolution in time domain: engineer methods of design economic scheme of decoders for optimal receiving in aggregate of suggested signal.

  • PDF

A Study on Projection for Apophyseal Joints Diagnosis in X-ray Thoracic Bone Oblique Projection (X-ray 등뼈의 사위 촬영에서 돌기사이관절의 진단을 위한 촬영법 연구)

  • Jun-Heang Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.351-357
    • /
    • 2023
  • This Study Rreceived Subjective Evaluation ROC Evaluation from five projection. of projection. at a University Hospital to Obtain and Diagnose Sharp images of apophyseal joints and Vertral arch of Thoracic vertebrae from thoracic X-ray projection. In the Subjective evaluation, the highest Score was obtained by raising the phantom from Supine to LAO by 70° and scoring 20 points at 5° with the X-ray Tube facing the head. In addition, he scored the highest score of 19 points at 8° with the Prone Phantom standing 60° with RAO and the X-ray Tube facing the head. For Objective Evaluation, the Signal-to-noise ratio, was calculated. ROI was set at 1,564 mm2 to obtain the image signal average value (Mean value) and the Standard deviation (SD value). Objective Evaluation The signal-to-noise ratio, was the highest at 5° toward the head in the LPO 70° position of the phantom in the lying position of the Thoracic spine projection, and the Thoracic Spine was the highest at 8° toward the head of the RAO posture of 5,645.