• 제목/요약/키워드: signal head

검색결과 414건 처리시간 0.027초

요구 적출형 잉크젯 프린트 헤드에서의 압력파 위상 정합 (Phase Matching of Pressure Wave in a Drop-On-Demand Inkjet Print Head)

  • 김명기;황준영;이상호;강경태;박문수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1444-1449
    • /
    • 2007
  • Inkjet printing technology with a drop-on-demand (DOD) inkjet head technology has been recognized as one of versatile and low cost manufacturing tools in the electronics industry. Concerned with control of driving signal, however, general strategy to optimize jetting stability has not been understood well, because of the inherent complex multi-physics nature in inkjet phenomena. Motivated by this, present study investigates the effect of driving waveforms of piezoelectric head on jetting characteristics of DOD inkjet system focused on jetting stability with phase matching of pressure waves in the print head. The results show that velocities and volumes of the ink jetted droplets were linear relations with the driving signal's maximum voltage, while periodic behaviors are observed with the driving signal's pulse widths.

  • PDF

초음파 도자를 쥐는 방법이 팔 근육의 근활성도에 미치는 영향 (The Influence of the Pattern of Gripping the Ultrasound Head on the Activity of Upper Limb Muscles)

  • 최석호;이충휘;전혜선;이정원
    • 한국전문물리치료학회지
    • /
    • 제20권2호
    • /
    • pp.28-37
    • /
    • 2013
  • This study examined differences in the activity of upper limb muscles according to how an ultrasound head is gripped. Twenty-two adult males were participated in the study. Each participant was asked to apply ultrasound treatment on to a lump of pork meat by two different ultrasound head grip patterns: spherical and cylindrical grips. Muscle activity was measured in the extensor carpi radialis longus (ECRL), flexor carpi ulnaris (FCU), and pronator teres (PT), triceps brachii (TB), middle deltoid (MD), and upper trapezius (UT) muscles. There were no significant differences in the EMG signals of any muscle according to the ultrasound head grip pattern (p>.05). There were significant differences in the EMG signal of each type of muscle (p<.05). The EMG signal of UT was the lowest and that of TB was lower than ECRL and FCU. There were interactions between ECRL and FCU, between ECRL and PT, between FCU and ECRL, and between FCU and MD. The EMG signal of ECRL using the cylindrical head was low and that of FCU with the cylindrical head was high, while the opposite was the case with the spherical head ($p_{adj}$ <.05/15). The results of this study indicate that the wrist muscles worked actively when the participants applied ultrasound therapy using both spherical and cylindrical heads. A spherical head might induce imbalanced muscle activity among the wrist muscles, leading to deviation of the wrist joint. Therefore, the cylindrical head is recommended for ultrasound therapy because it produced a constant, repeated force.

Perturbation and Perceptual Analysis of Pathological Sustained Vowels according to Signal Typing

  • 이지연;최성희;;한민수;최홍식
    • 말소리와 음성과학
    • /
    • 제2권2호
    • /
    • pp.109-115
    • /
    • 2010
  • In this paper, we investigate a signal typing on the basis of visual impression of distinctive spectrogram. Pathological voices are classified into signal type 1, 2, 3, or 4 to estimate perturbation parameters and to mark perceptual rating based on Consensus Auditory-Perceptual Evaluation of Voice (CAPE-V). The results suggest that perturbation analysis can be applied to only type 1 and 2 signals and the perceptual ratings of overall grade increase with each signal type, overall. A good inter-rater reliability is showed among three raters. We recommend that pathological voices should be marked the signal typing and CAPE-V, together, to definitely describe the characteristics of pathological voices.

  • PDF

압전세라믹을 이용한 사각보형 진동자이로의 설계 및 성능분석 (Design and Analysis of Square Beam Type Piezoelectric Vibrating Gyroscope)

  • 이정훈;박연규;이종원
    • 소음진동
    • /
    • 제5권3호
    • /
    • pp.403-411
    • /
    • 1995
  • Square beam type piezoelectric vibrating gyro is developed for the measurement of angular velocity, which is compact, small in size and mass- producible. It features that three pieces of piezoelectric ceramics and bonded onto one face of equilateral square bar type gyro head. Two of them are used as sentuators which drive the gyro head and measure Coriolis force. The third piece is used for the feedback signal in order to resonate the gyro head and measure Coriolis force. The third piece is used for the feedback signal in order to resonate the gyro head with its fundamental natural frequency. Matching two fundamental natural frequencies in the gyro head with its driving frequency is found critical in the design of vibration gyro. Calibration results show that the vibrating gyro developed has the dynamic characteristics of first-order system within the frequency range of interest, which can be easily compensated by a lead compensator.

  • PDF

교통소음의 모노럴과 바이노럴 청감 비교 연구 I: 측정 및 분석 (Comparison of Human Responses to Transportation Noise in Monaural and Binaural Hearing, Part I: Measurement and Analysis)

  • 김재환;임창우;정원태;홍지영;정완섭;이수갑
    • 한국소음진동공학회논문집
    • /
    • 제14권12호
    • /
    • pp.1268-1278
    • /
    • 2004
  • Measurement of noise is not only to know the information of acoustic pressure but to assess human response to noise. To find human response to transportation noise through the laboratory study we have to measure and reproduce noise. The method of noise reproduction is largely divided into monaural and binaural techniques. But human fundamentally hears sound through both ears, referred as binaural hearing. Binaural signal is different from monaural signal because it includes more information of physical phenomena like acoustical reflection, diffraction and refraction. Especially head and pinna play an important role in perceiving change of signal origin. So, the amplitude of binaural signal is higher than that of monaural signal and spectrum of both signals is discriminated. Most of assessment and regulation of transportation noise are, however, based on monaural measurement techniques. The quantitative difference between monaural and binaural measurement is investigated in this study. Comparison on several transportation noisesshows defect of information in monaural measurements.

TAA신호를 이용한 하드디스크의 헤드/디스크 인터페이스 분석 (Evaluation of Head/Disk interface using TAA Signal)

  • 박용식;이재모;김대은
    • 한국정밀공학회지
    • /
    • 제18권3호
    • /
    • pp.107-114
    • /
    • 2001
  • The durability of head/disk interface is an important issue for hard disk drives. Currently, there are several means of assessing the performance and integrity of the head/disk interface. In this work Track Average Amplitude(TAA) signal was used to analyzed the head/disk interface with respect to variations in disk velocity, slider pre-load and preformed scratch on the disk. Particularly, TAA variation due to disk defect in the form of a scratch was investigated.

  • PDF

Natural Frequency Analysis of Sliders and Head/Disk Interaction Detection by Acoustic Emission

  • Hwang, Pyung;Pan, Galina;Khan, Polina
    • KSTLE International Journal
    • /
    • 제5권1호
    • /
    • pp.28-31
    • /
    • 2004
  • The object of the present work is the natural frequency analysis of subambient pressure tri-pad and pico sliders. Head/disk interaction during start/stop and constant speed were detected by using the acoustic emission (AE) test system. The frequency spectrum analysis is performed using the AE signal obtained during the head/disk interaction. The FFT (Fast Fourier Transform) analysis of the AE signals is used to understand the interaction between the AE signal and the state of contact. Natural frequency analysis was performed using the Ansys program. The results indicate acceptable accordance of finite element calculation results with the experimental results.

Gadoteridol을 이용한 Head & Neck MR Angiography에서의 적정 Flip Angle (Optimization of Flip Angle at Head & Neck MR Angiography using Gadoteridol)

  • 정현근;김민기;송재준;남기창;최현성;정현도;김호철
    • 전자공학회논문지
    • /
    • 제53권3호
    • /
    • pp.151-159
    • /
    • 2016
  • 본 연구의 목적은 가돌리늄 조영제를 사용한 Head & Neck MR Angio검사에 있어서 매개변수인 FA(Flip Angle)이 MR신호에 미치는 영향에 대해서 알아보고자 하였으며, 이에 따른 FA의 적정 값을 제시하는 것이다. 실험은 FA증가에 따른 MR팬텀실험과 임상실험으로 진행하였고, 이에 대한 정량적 분석이 이루어졌다. 실험결과 팬텀실험에서의 조영증강 반응시작 지점인 RSP(Reaction Starting Point)는 FA증가에 따라 300~400 mmol 사이에서 반응하였고, 최대 신호강도인 MPSI(Max Peak Signal Intensity)는 2,086, 3,705, 5,109, 6,194, 7.096, 7,192 [a.u]를 기록하였다. MPSI가 형성되는 몰농도 지점인 MPP(Max Peak Point)는 FA에 증가에 따라 40, 50, 50, 40, 50, 40 mmol에서 보였으며, MPSI의 증가율인 IRMPSI(Increase Rate of MPSI)는 77.6%, 37.9%, 21.2%, 14.6%, 1.4%임을 확인하였다. 임상실험에서의 평가기준인 SICB(Signal Intensity of Carotid artery Bifurcation)는 FA증가에 따라 각 평균값 2392.5, 4165.2, 4270, 3502.2, 3263.7, 3119.6 [a.u]를 기록하였고, 아티팩트 발생율인 ORA(Occurence Rate of Artifact)는 0, 0, 20, 40, 50, 70%로 점차 증가하였다. 본 연구를 통하여 FA의 증가는 혈관 내 가돌리늄과 결합한 H1스핀의 신호강도와 아티팩트에 영향을 미친다는 사실을 확인하였고, 이는 실제 임상에서의 CE(Contrast Enhanced)-Head&Neck MR Angio검사에 있어서 본 연구의 데이터를 활용한다면 진단학적으로 효율적인 MR Angiography 영상을 구현할 수 있을 것으로 사료된다.

Clinical Factors Influencing the Trial and Purchase of Bilateral Microphones with Contralateral Routing of Signal in Patients with Asymmetric Sensorineural Hearing Loss

  • Seong, Jeon;Yang, Seung Koo;Jang, Pilkeun;Lee, Sang-Yeon;Carandang, Marge;Choi, Byung-Yoon
    • Journal of Audiology & Otology
    • /
    • 제24권1호
    • /
    • pp.29-34
    • /
    • 2020
  • Background and Objectives: Bilateral microphones with contralateral routing of signal (BiCROS) hearing aid is an option for hearing rehabilitation in individuals with asymmetric sensorineural hearing loss (ASNHL). The clinical factors influencing the trial and purchase of BiCROS were investigated. Subjects and Methods: We reviewed the medical records of 78 patients with ASNHL who were recommended to use BiCROS and analyzed the demographic and audiological factors influencing the trial and purchase of BiCROS. Results: Among the 78 patients, 52 (66.7%) availed of the free BiCROS trial and 21 (26.9%) purchased BiCROS. The mean pure tone audiometry (PTA) air conduction (AC) threshold of the better- and worse-hearing ears were 44.2±12.8 dB and 90.7±22.5 dB HL, respectively. The decision for trial or purchase of BiCROS was not influenced by age, sex, duration of hearing loss of the worse-hearing ear, or PTA AC threshold or speech discrimination score of both ears. The first and third quartiles of the PTA AC thresholds for the better-hearing ear of BiCROS buyers were 38.75 dB and 53.75 dB HL, respectively. The counterpart values for the worse-hearing ear were 72.50 dB and 118.75 dB HL, respectively. Conclusions: The clinical factors analyzed in this study were found to be irrelevant to the trial and purchase of BiCROS in patients with ASNHL. Nevertheless, the distribution range of the auditory thresholds of the subjects using BiCROS can be a useful basis for the counseling of patients with ASNHL and selection of candidates for BiCROS use.

A Study of contact Detection and Position Sensitivity of AE Sensor

  • Kwon, Haesung;Choa, Sung-Hoon
    • KSTLE International Journal
    • /
    • 제1권1호
    • /
    • pp.29-33
    • /
    • 2000
  • In this study, a methodology is developed and confirmed to find the physical contact between the slider and disc due to the defects of disk during head seeking operation using acoustic emission (AE) signal. The head/disk contact was detected during random and standard seeks, whereas no contact was detected during track fellowing. During standard and random seeks, the torsion mode of slider excitation was observed at 680KHz. Therefore, it is thought that AE technique can be used as an alternative method of the glide test by monitoring existence of the torsional mode of the slider during seek operation or can be used to detect the spacing loss during seeking operation. By appropriately choosing the location of the sensor an order of magnitude increase in the sensitivity for RMS AE signal is observed. Therefore we can find take-off velocity clearly with high signal to noise ratio of AE signal.

  • PDF