• Title/Summary/Keyword: signal head

Search Result 414, Processing Time 0.024 seconds

Volume Rendering Using Multi-Textures (Multi-Textures를 이용한 Volume Rendering)

  • 박재영;이병일;최흥국
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2000.12a
    • /
    • pp.169-172
    • /
    • 2000
  • Direct volume rendering has yet been restricted to high-end graphic workstations and special-purpose hardware, due to the large amount of trilinear interpolation, that are necessary to obtain high image quality. In this paper, we implemented the volume rendering techniques using the 2D-texture at the environment of standard PC hardware. In addition, we show how multi-texturing capabilities of modern PC graphics board are enable to volume rendering. Besides using extended OpenGL function, we improved pixel operations and rendering capacity.

  • PDF

A Study on Analysis and 3D Web Environment for the Treatment Alcoholism (알코중독 치료를 위한 Web 환경 시스템과 분석에 대한 연구)

  • Paek, Seung-Eun
    • The Journal of Information Technology
    • /
    • v.9 no.1
    • /
    • pp.9-19
    • /
    • 2006
  • Medications or conitive-behavior methods have been mainly used as a treatment of alcoholism. lately the virtualy technology has been applied to the kink of alcoholic disorders. A virtual environment makes him having avility to over come the drink. In this study, we were implemented by making panorama images and 3D object modules using 3D MAX, VRML, JAVA. And the BAR stimulator that composed with a position sensor, head mount display, and audio system, is suggested. To illustrate the physiological difference between a person who has a alcoholism and without a liquor bottle, heart rate was measured during experiment, and also measured a person's HR after the virtual reality training. The system measures the Physiological signals such as ECG, Temperature, analyzes those data automatically. The system has two parts, one is physiological data acquisition part which gets the body signal, and the other one is mobile nuit which includes signal processing and transmission functions, And Bluetooth allows two parts to communicate with each other. we demonstrated the subjective effectiveness of virtual reality psychotherapy through the clinical experiment.

  • PDF

Enhancement Algorithm of Panoramic Thermal Imaging Warning System for Small Target Detection (소형 표적 탐지를 위한 파노라믹 적외선 영상 개선 알고리즘)

  • Kim, Gi-Hong;Jeon, Byeong-Gyun;Kim, Ju-Yeong;Kim, Deok-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.400-403
    • /
    • 2003
  • This paper presents the signal processing of the panoramic thermal warning system that detects the small target such as aircraft and helicopter from afar. We develope the all round looking thermal imaging system which can scan all the way. This system acquires the panoramic images to reconstruct the IR images by revolving head of sensor typed line sensor at high speed. For detection, where the object of interest may be small, it is sometimes difficult to specify from object and background by conventional contrast enhancement methods. Therefore we use the adaptive plateau equalization algorithm each region to improve the contrast and make the hardware system which consists of the signal processing board for real-time display. We can verify the proposed method by the computer simulation and the hardware implementation.

  • PDF

MR Imaging of Shaken Baby Syndrome Manifested as Chronic Subdural Hematoma

  • Yul Lee;Kwan Seop Lee;Dae Hyun Hwang;In Jae Lee;Hyun Beom Kim;Jae Young Lee
    • Korean Journal of Radiology
    • /
    • v.2 no.3
    • /
    • pp.171-174
    • /
    • 2001
  • Shaken baby syndrome (SBS) is a form of child abuse that can cause significant head injuries, of which subdural hematoma (SDH) is the most common manifestation. We report the MRI findings of chronic SDH in three cases of SBS, involving two-, three- and eight-month-old babies. The SDH signal was mostly low on T1-weighted images and high on T2-weighted images, suggesting chronic SDH. In chronic SDH, a focal high signal on T1-weighted images was also noted, suggesting rebleeding. Contrast-enhanced MRI revealed diffuse dural enhancement.

  • PDF

Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch (대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • Purpose : To assess the clinical utility of turbo contrast-enhanced magnetic resonance angiography(CE MRA) in the evaluation of the aortic arch and its major branches and to compare the image quality of CE MRA among different coils used. Materials and Methods : Turbo three-phase dynamic CE MRA encompassing aortic arch and its major branches was prospectively performed after manual bolus IV injection of contrast material in 29 patients with suspected cerebrovascular diseases at 1.0T MR unit. the raw data were obtained with 3-D FISH sequence (TR 5.4ms, TE 2.3ms, flip angle 30, slab thickness 80nm, effective slice thickness 4.0mm, matrix size $100{\times}256$, FOV 280mm). Total data acquisition time was 4. to 60 seconds. We subjectively evaluated the imge quality with three-rating scheme : "good" for unequivocal normal finding, "fair" for relatively satisfactory quality to diagnose 'normal' despite intravascular low signal, and "poor" for equivocal diagnosis or non-visualization of the origin or segment of the vessels due to low signal or artifacts which needs catheter angiography. At the level of the carotid bifurcation, it was compared with conventional 2D-TOF MRA image. Overall image quality was also compared visually and quantitatively by measuring signal-to-noise ratios (SNRs) of the ascending aorta, the innominate artery and both common carotid arteries among the three different coils used(CP body array(n=12), CP neck array(n=9), and head-and-neck(n=8). Results : Demonstration of the aortic arch and its major branches was rated as "good" in 55% (16/29) and "fair" in 34%(10/29). At the level of the carotid bifurcation, image quality of turbo CE MRA was same as or better than conventional 2D-TOF MRA in 65% (17/26). Overall image quality and SNR were significantlygreater with CP body array coil than with CP neck array or head-and-neck coil. Conclusions : Turbo CE MRA can be used as a screening exam in the evaluation of the major branches of the aortic arch from their origin to the skull base. Overall imagequality appears to be better with CP body array coil than with CP neck array coil or head-and-neck coil.

  • PDF

An Hybrid Clustering Using Meta-Data Scheme in Ubiquitous Sensor Network (유비쿼터스 센서 네트워크에서 메타 데이터 구조를 이용한 하이브리드 클러스터링)

  • Nam, Do-Hyun;Min, Hong-Ki
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.4
    • /
    • pp.313-320
    • /
    • 2008
  • The dynamic clustering technique has some problems regarding energy consumption. In the cluster configuration aspect the cluster structure must be modified every time the head nodes are re-selected resulting in high energy consumption. Also, there is excessive energy consumption when a cluster head node receives identical data from adjacent cluster sources nodes. This paper proposes a solution to the problems described above from the energy efficiency perspective. The round-robin cluster header(RRCH) technique, which fixes the initially structured cluster and sequentially selects duster head nodes, is suggested for solving the energy consumption problem regarding repetitive cluster construction. Furthermore, the issue of redundant data occurring at the cluster head node is dealt with by broadcasting metadata of the initially received data to prevent reception by a sensor node with identical data. A simulation experiment was performed to verify the validity of the proposed approach. The results of the simulation experiments were compared with the performances of two of the must widely used conventional techniques, the LEACH(Low Energy Adaptive Clustering Hierarchy) and HEED(Hybrid, Energy Efficient Distributed Clustering) algorithms, based on energy consumption, remaining energy for each node and uniform distribution. The evaluation confirmed that in terms of energy consumption, the technique proposed in this paper was 29.3% and 21.2% more efficient than LEACH and HEED, respectively.

  • PDF

Adaptation of Deep Learning Image Reconstruction for Pediatric Head CT: A Focus on the Image Quality (소아용 두부 컴퓨터단층촬영에서 딥러닝 영상 재구성 적용: 영상 품질에 대한 고찰)

  • Nim Lee;Hyun-Hae Cho;So Mi Lee;Sun Kyoung You
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.240-252
    • /
    • 2023
  • Purpose To assess the effect of deep learning image reconstruction (DLIR) for head CT in pediatric patients. Materials and Methods We collected 126 pediatric head CT images, which were reconstructed using filtered back projection, iterative reconstruction using adaptive statistical iterative reconstruction (ASiR)-V, and all three levels of DLIR (TrueFidelity; GE Healthcare). Each image set group was divided into four subgroups according to the patients' ages. Clinical and dose-related data were reviewed. Quantitative parameters, including the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and qualitative parameters, including noise, gray matter-white matter (GM-WM) differentiation, sharpness, artifact, acceptability, and unfamiliar texture change were evaluated and compared. Results The SNR and CNR of each level in each age group increased among strength levels of DLIR. High-level DLIR showed a significantly improved SNR and CNR (p < 0.05). Sequential reduction of noise, improvement of GM-WM differentiation, and improvement of sharpness was noted among strength levels of DLIR. Those of high-level DLIR showed a similar value as that with ASiR-V. Artifact and acceptability did not show a significant difference among the adapted levels of DLIR. Conclusion Adaptation of high-level DLIR for the pediatric head CT can significantly reduce image noise. Modification is needed while processing artifacts.

Characteristics of temporomandibular joint structures after mandibular condyle fractures revealed by magnetic resonance imaging

  • Kim, Bong Chul;Lee, Yoon Chang;Cha, Hyung Seok;Lee, Sang-Hwy
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.24.1-24.7
    • /
    • 2016
  • Background: This study aimed to evaluate the structural changes of temporomandibular joint immediately after condylar fractures with magnetic resonance imaging (MRI). Method: We evaluated 34 subjects of condylar fractures with MRI. The position, shape, and signal intensity of the condyle, disc, and retrodiscal tissue were analyzed with MR images. Results: Immediately after trauma, the disc was displaced with the fractured segment in almost all cases. And, the changes of signal intensity at the retrodiscal tissue were found but less related to the degree of fracture displacement. And, the high signals were observed almost at all fractured joint spaces and even at some contralateral joints. Conclusions: The displaced disc as well as the increased signal intensity of the joint space, condylar head, and retrodiscal tissue demands more attention to prevent the possible sequela of joint.

An Acoustic Echo Canceler under 3-Dimensional Synthetic Stereo Environments (3차원 합성 입체음향 환경에서의 음향반향제거기)

  • 김현태;박장식
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.7A
    • /
    • pp.520-528
    • /
    • 2003
  • This paper proposes a method of implementing synthetic stereo and an acoustic echo cancellation algorithm for multiple participant conference system. Synthetic stereo is generated by HRTF and two loudspeakers. A robust adaptive algorithm for synthetic stereo echo cancellation is proposed to reduce the weight misalignment due to near-end speech signals and ambient noises. The proposed adaptive algorithm is modified version of SMAP algorithm and the coefficients of adaptive filter is updated with cross correlation of input and estimation error signal normalized with sum of the autocorrelation of input signal and the power of the estimation error signal multiplied with projection order. This is more robust to projection order and ambient noise than conventional SMAP. Computer simulation show that the proposed algorithm effectively attenuates synthetic stereo acoustic echo.

Effect of Recording Density On the Reproducin Voltage in Perpendicular Magnetic Recording System (수직자기 기록장치에서 기록밀도가 재생전압에 미치는 영향)

  • 박관수;이향범;한송엽;이택동;징평우
    • Journal of the Korean Magnetics Society
    • /
    • v.1 no.2
    • /
    • pp.74-78
    • /
    • 1991
  • The method for analyzing the recording and reading process of magnetic recording system by numerical simulation is introduced. which can simulate the effect of elements of the magnetic recording system. During the whole simulation, hysteresis characteristics must be included. Preisach model and finite element method are used to construct the algorithm. From the wave of recording current, recorded pattern of magnetization in recording media is simulated in recording process, and then waveform of reading signal in head coil is obtained in reading process. To show the validity of this method, this is applied to perpendicular magnetic recording system. Waveform of recording signal and reproduced signal is obtained in several density. Pattern of reprocuced voltage magnitude according to increase of recording density shows roll-off curve.

  • PDF