• Title/Summary/Keyword: signal control scheme

Search Result 624, Processing Time 0.03 seconds

Position Control of Servo Motor using Hybrid Controller (하이브리드 제어기를 이용한 서보 전동기의 위치제어)

  • Kwon, Se-Hyun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.3
    • /
    • pp.186-192
    • /
    • 2009
  • PID controllers are simple in structure and easy for implementation. However, they may produce large overshoots and over-oscillatory responses. Combining PID control with other control techniques often results in advanced hybrid schemes that are able to improve pure PID controllers. This paper proposes hybrid controller for position control system of servo motor. The proposed controller is composed of a subcontroller and a parallel PID controller. The subcontroller improves the transient system performance while the PID controller is mainly responsible for the steady-state system performance. A very promising advantage of this hybrid scheme, in terms of controller synthesis, is that the subcontrollers and controller components can be designed separately. Systematic design methods for various controller components are developed. The proposed hybrid scheme is applied to a DC motor position servo system. The effectiveness of the proposed controller is verified through the computer simulation results.

  • PDF

The Controller Design of a 2.4MJ Pulse Power Supply for a Electro-Thermal-Chemical Gun (전열화학포용 2.4MJ 펄스 파워 전원의 제어기 설계)

  • Kim, Jong-Soo;Jin, Y.S.;Lee, H.S.;Rim, Geun-Hie;Kim, J.S.
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.12
    • /
    • pp.511-517
    • /
    • 2006
  • The key issues in high power, high energy applications such as electromagnetic launchers include safety, reliability, flexibility, efficiency, compactness, and cost. To explore some of the issues, a control scheme for a large current wave-forming was designed, built and experimentally verified using a 2.4MJ pulse power system (PPS). The PPS was made up of eight capacitors bank unit, each containing six capacitors connected in parallel. Therefore there were 48 capacitors in total, with ratings of 22kV and 50kJ each. Each unit is charged through a charging switch that is operated by air pressure. For discharging each unit has a triggered vacuum switch (TVS) with ratings of 200kA and 250kV. Hence, flexibility of a large current wave-forming can be obtained by controlling the charging voltage and the discharging times. The whole control system includes a personal computer(PC), RS232 and RS485 pseudo converter, electric/optical signal converters and eight 80C196KC micro-controller based capacitor-bank module(CBM) controllers. Hence, the PC based controller can set the capacitor charging voltages and the TVS trigger timings of each CBM controller for the current wave-forming. It also monitors and records the system status data. We illustrated that our control scheme was able to generate the large current pulse flexibly and safely by experiments. The our control scheme minimize the use of optical cables without reducing EMI noise immunity and reliability, this is resulting in cost reduction. Also, the reliability was increased by isolating ground doubly, it reduced drastically the interference of the large voltage pulse induced by the large current pulse. This paper contains the complete control scheme and details of each subsystem unit.

Droop Control Scheme of a Three-phase Inverter for Grid Voltage Unbalance Compensation

  • Liu, Hongpeng;Zhou, Jiajie;Wang, Wei;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1245-1254
    • /
    • 2018
  • The stability of a grid-connected system (GCS) has become a critical issue with the increasing utilization of renewable energy sources. Under grid faults, however, a grid-connected inverter cannot work efficiently by using only the traditional droop control. In addition, the unbalance factor of voltage/current at the common coupling point (PCC) may increase significantly. To ensure the stable operation of a GCS under grid faults, the capability to compensate for grid imbalance should be integrated. To solve the aforementioned problem, an improved voltage-type grid-connected control strategy is proposed in this study. A negative sequence conductance compensation loop based on a positive sequence power droop control is added to maintain PCC voltage balance and reduce grid current imbalance, thereby meeting PCC power quality requirements. Moreover, a stable analysis is presented based on the small signal model. Simulation and experimental results verify the aforementioned expectations, and consequently, the effectiveness of the proposed control scheme.

Transmit Precoder Design for Two-User Broadcast Channel with Statistical and Delayed CSIT

  • Sun, Yanjing;Zhou, Shu;Cao, Qi;Wang, Yanfen;Liu, Wen;Zhang, Xiaoguang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.12 no.5
    • /
    • pp.2124-2141
    • /
    • 2018
  • Recent studies have revealed the efficacy of incorporating delayed channel state information at transmit side (CSIT) in transmission scheme design. This paper focuses on transmit precoder design to maximize the ergodic sum-rate in a two-user Multiple-Input Single-Output (MISO) system with delayed and statistical CSIT. A new transmit strategy which precodes signals in all transmit slots is proposed in this paper, denoted as all time-slots precoding Alternative MAT (AAMAT). There is a common procedure in conventional delayed-CSIT based schemes, which is retransmitting the overheard interferences. Since the retransmitting signal is intended to both users, all previous schemes tend to use only one antenna. We however figure out an improvement in spectral efficiency could be realized if all antennas can be utilized. In this paper, we detail the design of the procoder which enabling all antennas and also we compute a lower bound of the ergodic sum-rate in an ideal condition. In addition, simulation results demonstrate the superiority of our proposed scheme.

Speaker Verification System with Hybrid Model Improved by Adapted Continuous Wavelet Transform

  • Kim, Hyoungsoo;Yang, Sung-il;Younghun Kwon;Kyungjoon Cha
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.3E
    • /
    • pp.30-36
    • /
    • 1999
  • In this paper, we develop a hybrid speaker recognition system [1] enhanced by pre-recognizer and post-recognizer. The pre-recognizer consists of general speech recognition systems and the post-recognizer is a pitch detection system using adapted continuous wavelet transform (ACWT) to improve the performance of the hybrid speaker recognition system. Two schemes to design ACWT is considered. One is the scheme to search basis library covering the whole band of speech fundamental frequency (speech pitch). The other is the scheme to determine which one is the best basis. Information cost functional is used for the criterion for the latter. ACWT is robust enough to classify the pitch of speech very well, even though the speech signal is badly damaged by environmental noises.

  • PDF

Implementation of Random Carrier-Frequency Modulation Scheme for a DSP based PWM Inverter for Acoustic Noise Reduction of Induction Motors (유도전동기의 소음저감을 위한 DSP기반 PWM인버터의 랜덤 캐리어 주파수 변조기법의 구현)

  • 정영국;나석환;임영철;정성기
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.12
    • /
    • pp.608-615
    • /
    • 2003
  • This paper describes an implementation of a DSP (Digital Signal Processor) controlled random carrier frequency modulation for the PWM inverter for acoustic noise reduction of induction motors. Real-time generation of the random variable and RPWM(Random PWM) along with the speed control was achieved by DSP TMS320C31. The experimental results show that the voltage and current harmonics are spread to a wide band area and the power spectrum of the acoustic switching noise was spread to create a more appealing, less annoying sound. Also, the speed response of the implemented method and the conventional method is nearly similar to each other from the viewpoint of the v/f constant control.

Link Quality Based Transmission Power Control in IEEE 802.15.4 for Energy Conservation

  • Nepali, Samrachana;Shin, Seokjoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.12
    • /
    • pp.1925-1932
    • /
    • 2016
  • One of the major challenges in the design of wireless sensor network (WSN) is to reduce the energy consumption of sensor nodes for prolonging the network lifetime. In the sensor network, communication is the most energy consuming event. Therefore, most of the energy saving techniques conserve energy by adjusting different parameters of the trans-receiver. Among them, one of the promising methods is the transmission power control (TPC). In this paper, we investigated the effects of the link quality based TPC scheme employed to the IEEE 802.15.4 standard for energy saving. The simulation results demonstrated that the link quality based TPC scheme works effectively in conserving energy as compared to the conventional IEEE 802.15.4.

Sensorless Control of IPMSM using State Observer (상태관측기를 이용한 IPMSM의 센서리스 제어)

  • Song, Jae-Joo;Lee, Jeong-Cheol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05b
    • /
    • pp.71-74
    • /
    • 2003
  • The paper is proposed to position and speed control of interior permanent magnet synchronous motor(IPMSM) drive without mechanical sensor. A minimum order state observer is used for the mechanical state estimation of the motor. The observer was developed based on nonlinear model of IPMSM, that employs a d-q rotating reference frame attached to the rotor. A minimum order state observer is implemented to compute the speed and position feedback signal. The validity of the proposed sensorless scheme is confirmed by various response characteristics.

  • PDF

Predictive Instantaneous Control of inverter for UPS (UPS용 예측 순시제어형 인버터)

  • Kim, B.J.;Kim, J.H.;Cho, J.H.;Kim, J.S.;Lee, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.237-239
    • /
    • 1995
  • The inverter for UPS system is required to satisfy pure sinusoidal output voltage with very low THD(Total Harmonic distortion). This paper proposes a TMS320c31 digital signal processor based predictive instantaneous control scheme of inverter. The proposed scheme is able to satisfy the conditions; high capability, high efficiency, low audible noise and robustness of inverter. The transient state characteristics of proposed inverter has been improved. in case of power failure or recovery, nonlinear load, sudden load change or parameters variations. Finally, the performance of the proposed inverter is shown and discussed by simulation and experiment.

  • PDF

GPS L1, L2C Signal Acquisition Performance of GPS Software Receiver with respect to Pseudolite Pulsing Scheme (의사위성의 펄싱 방법에 대한 GPS L2C 신호획득 성 소능프분트석웨어 수신기의 L1, L2C 신호획득 성능분석)

  • Kwon, Keum-Cheol;Yand, Cheol-Kwan;Shim, Duk-Sun;Chung, Tae-Sang;Kee, Chand-Don
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.1
    • /
    • pp.16-26
    • /
    • 2012
  • Pseudolites are ground-based transmitters that can be configured to emit GPS-like signals for enhancing the GPS by providing increased accuracy, integrity, and availability. However, a pseudolite (PL) can interfere with GPS satellite signals while it is transmitting or cause saturation to automatic gain control circuit. To solve these problems pulsing scheme is used, which transmits PL signal during a short period of time. In this paper the effect of the number of PL and pulsing scheme on the software GPS L1 and L2C signal acquisition performance is studied for the three pulsing schemes such as static pulsing, sweep pulsing, and pseudo random pulsing. For GPS L1 signal, static pulsing shows the best signal acquisition and tracking performance with one PL, and random pulsing shows the best performance with more than or equal to two PLs. For GPS L2C signal, all three pulsing schemes show the similar signal acquisition and tracking performance, but static pulsing shows a little better performance. For GPS L1 and L2C signals, software GPS receivers can do positioning with up to three PLs.