• Title/Summary/Keyword: signal attenuation

Search Result 436, Processing Time 0.024 seconds

Power Line Simulator Development for Communication Channel (통신 채널로써 전력선 시뮬레이터 개발)

  • Park, Chong-Yeun;Jung, Dong-Youl
    • Journal of Industrial Technology
    • /
    • v.19
    • /
    • pp.81-89
    • /
    • 1999
  • We have developed a power line simulator which is one of the basic tools for the research of the power line communication and its control system. In the developed simulators, we have considered the transfer function of the power line, noises and signal attenuation characteristics. Simulator was made using the matlab tool program. We made the power line modern using the FSK chip(ST7537) and experimentalized to show the efficiency grade of simulator. We have expected that the developed simulators are very useful in the area for the power line communication research and the control system design.

  • PDF

Detection of Ultrasonic Wave Signals Associated with Partial Discharge in XLPE (가교폴리에틸렌(XLPE)의 부분방전에 의한 초음파 검출)

  • 김성규;이상우;구경철;김충년;김인식;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.136-140
    • /
    • 1999
  • Measurements of AE signals caused by partial discharges were performed by using an ultrasonic measurement technique to diagonise the electrical treeing deterioration in XLPE cable. We also examined the partial discharge magnitude and AE signals(peak-to-peak) with the increase of the deterioration time. From these results, it was found that AE signal due to partial discharge can be greatly detected at the peak value of positive polarities prior to the breakdown voltages, and the magnitude of AE signals was closely related to the current pulses by the increase of deterioration, and it appeared that AE signals(peak-to-peak) was proportional to partial discharge magnitude. Attenuation and time-delaying characteristics of ultrasonic signals propagated in various polymers sample by using ultrasonic oscillation and receiving systems are also reported as a basic data of ultrasonic measurements in XLPE cable.

  • PDF

A Study on the Power Line Control System for Electric Machinery using Power Line Communication (전력선 반송통신을 이용한 전기기기 전원 제어 시스템에 관한 연구)

  • 김경엽;문복산;김영일;서인호;천행춘;강대기;유영호
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.115-122
    • /
    • 2000
  • Recently, a study on the Power Line Communication has been done by many companies and institutes due to its own merits that we can use the power line as a communication channel. But, there are serious problems about the harsh and unpredictable characteristics - noise, signal distortion and attenuation to be overcome in order that we commercialize the Power Line Communication. In this paper, we analyse the power line characteristics and apply the technology of PLC to control power of electric machinery by using ASK modulation.

  • PDF

32-Channel EEG and Evoked Potential Mapping System (32채널 뇌파 및 뇌유전발전위 Mapping 시스템)

  • 안창범;박대준
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.2
    • /
    • pp.179-188
    • /
    • 1996
  • A clinically oriented 32-channel electroencephalogram (EEG) and evoked potential (EP) mapping system has been developed EEG and EP signals acquired from 32-channel electrodes attached on the heroid surface are amplified by a pre-amplifier which is separated from main amplifier and is located near the patient to reduce signal attenuation and noise contamination between electrodes and the amplifier. The amplified signals are further amplified by a main amplifier where various filtering and gain contr61 are achieved An automatic artifact rejection scheme is employed using neural network-based EEG and artifact classifier, by which examination time is substantially reduce4 The continuously measured EEG sigrlals are used for spectral mapping, and auditory and visual evoked potentials measured in synchronous to the auditory and visual stimuli are used for temporal evoked potential mapping. A user-friendly graphical interface based on the Microsoft Window 3.1 is developed for the operation of the system. Statistical databases for comparisons of group and individual are included to support a statistically-based diagnosis.

  • PDF

Application of DSP for Processing the Reflected Ultrasonic Signal in Biological Tissue (생체조직내의 초음파 반사신호 처리를 위한 DSP 응용)

  • Lee, S.M.;Min, H.K.;Choi, H.H.;Hong, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.720-722
    • /
    • 1988
  • The Diagnostic applications of Ultrasound are developed in many ways. In this paper, We measure the attenuation coeffient of biological tissue using DSP. This method is useful in tissue characterization with real time. In the future, We expect that this method coupling with the ultrasonic temperature dependence of biological tissue also is applied to hyperthermia.

  • PDF

Field Trial of the Korean-Made 45Mb/s Optical Fiber Communication System (45Mb/s 국산 광직유 통신 시스템의 현장 시험)

  • 강민호;이용택;이상호;이만섭;유강희;박희갑;이성은;추흥로
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.32 no.2
    • /
    • pp.50-58
    • /
    • 1983
  • In this paper, a field trial of the Korean-made optical fiber communication system is described. This system was installed between Gu-Ro and Ann-Yang telephone offices on November 1981, and carries a 44.7Mb/s NRZ signal(672 voice channel equivalent). For this trial, optical fiber cable, optical terminal equipment, optical repeater, fusion splicer and measurement equipment have been developed. Employing graded index optical fiber at a wave length of $0.85\;\mu\textrm{m}$, average optical attenuation and splicing losses of 3.6 dB/km and 0.4 dB, resectively, were realized. With link margins of 8~20dB and bit error rate of less than $10^{-10}$, this system has been carrying live traffic between Seoul and Ann Yang telephone offices.

Comparison of Spectrophotometric, HPLC and Chemilumines­cence Methods for 3-Nitrotyrosine and Peroxynitrite Interaction

  • Turan Nilufer Nermin;Ark Mustafa;Demiryurek Abdullah Tuncay
    • Archives of Pharmacal Research
    • /
    • v.28 no.3
    • /
    • pp.358-363
    • /
    • 2005
  • We have studied the interaction of 3-nitrotyrosine with peroxynitrite using three different methods; chemiluminescence, spectrophotometry and HPLC. Peroxynitrite-induced luminol or lucigenin chemiluminescence were significantly decreased by 3-nitrotyrosine, in concentration­dependent manners. The intensity of the peroxynitrite spectrum was also markedly reduced in the presence of 3-nitrotyrosine in the spectrophometric assay. However, there was no attenuation of the 3-nitrotyrosine signal in the HPLC assay after mixing with peroxynitrite. The interaction of 3-nitrotyrosine and hypochlorous acid (HOCI) was also studied via the chemilumines-cence assay, where the HOCI-induced responses were markedly inhibited by 3-nitrotyrosine. These results suggest that caution should be taken when studying the levels or interactions of 3-nitrotyrosine.

Dynamic User Association based on Fractional Frequency Reuse

  • Ban, Ilhak;Kim, Se-Jin
    • Journal of Integrative Natural Science
    • /
    • v.13 no.1
    • /
    • pp.1-7
    • /
    • 2020
  • This paper proposes a novel fractional frequency reuse(FFR) based on dynamic user distribution. In the FFR, a macro cell is divided into two regions, i.e., the inner region(IR) and outer region(OR). The criterion for dividing the IR and OR is the distance ratio of the radius. However, these distance-based criteria are uncertain in measuring user performance. This is because there are various attenuation phenomena such as shadowing and wall penetration as well as path loss. Therefore, we propose a novel FFR based on dynamic user classification with signal to interference plus noise ratio(SINR) of macro users and classify the FFR into two regions newly. Simulation results show that the proposed scheme has better performance than the conventional FFR in terms of SINR and throughput of macro cell users.

Spectroscopic Study of the Ã1A" - X~1A' System of CHBr

  • Shin, Seung-Keun;Park, Seung-Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.3
    • /
    • pp.905-908
    • /
    • 2011
  • We report fluorescence excitation and emission spectra of the CHBr molecule generated via pyrolysis of $CH_3Br$ in a molecular beam experiment. The 193 nm attenuation cross sections were estimated from the reduction of the CHBr signal as a function of the excimer laser fluence. The derived 193 nm absorption cross section for CHBr [$(3.24{\pm}0.59){\times}10^{-17}\;cm^2$] is slightly higher than the absorption cross section previously determined for CHCl [$(2.6{\pm}0.8){\times}10^{-17}\;cm^2$], but the difference is within the estimated uncertainties in the measured cross section.

A Study on the Power Control System for Electric Machineries using Power Line Communication (전력선 반송통신을 이용한 전기기기 전원 제어 시스템에 관한 연구)

  • 김경엽;문복산;유영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.889-897
    • /
    • 2001
  • Recently, a lot of studies on the power line communication(PLC) are being done by many companies and institutes due to its own merit which can use the power line spread widely as a communication channel. But, there are many serious problems about the harsh and unpredictable characteristics, or noise, signal distortion and attenuation to be overcome for commercialization. In this paper, the power line characteristics as the view point of communication channel are investigated and the technologies of PLC are proposed to control the power of electric machineries by using the combined method of ASK modulation and microprocessor technologies. Also experiments are carried out to ascertain performance in case of applying to electric lights control according to various distancea as an example.

  • PDF