• Title/Summary/Keyword: side lobe

Search Result 308, Processing Time 0.022 seconds

Directional Characteristics of Sleeve-gun Arrays in Marine Seismic Survey (해양 탄성파 탐사에서 슬리브건 배열의 방향 특성)

  • Yoo, Hai-Soo;Yang, Sung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.71-80
    • /
    • 1996
  • Characteristics of sleeve-gun arrays installed on the R/V Onnuri were analyzed and compared with survey data. In the case of cluster array, the beam width in the frequency range up to 814Hz is constant as $179.5^{\circ}$, and rapidly narrows in the frequency range of 814-1631Hz. However, in the case of long and wide arrays, as the frequency increases, the beamwidth decreases. The optimal frequency is 69Hz. the main lobe of vertical inclination has its maximum amplitude at phase angle $0^{\circ}$. The optimal frequency of cluster array which produces little side lobe is less than 1631Hz, and those of long and wide arrays are less than 108Hz. As a result, the cluster array produces a good source for high-resolution seismic survey, while the long and wide arrays are suitable for the survey of deep structures. The final high-resolution seismic section with cluster array was compared with that of long and wide arrays.

  • PDF

A Case of homonymous Hemianopia after Occipital-Parietal Lobe Hemorrhage Treated with Combined Korean Medical Treatment (동측 반맹을 호소하는 후두엽-두정엽 뇌출혈 환자에 대한 복합 한의치험 1례)

  • Seong Hoon, Jeong;In Hu, Bae;Geun Young, Kim;Ki-Ho, Cho;Sang-Kwan, Moon;Woo-Sang, Jung;Seungwon, Kwon;Han-Kyul, Lee
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.23 no.1
    • /
    • pp.65-72
    • /
    • 2022
  • ■Background Overall prevalence of visual field loss after stroke was estimated at 31%, ranged from 5.5- 57%. Among them, homonymous hemianopia is the most common symptom of post-stroke visual field loss and leads to a decrease in the quality of life and therapeutic effect. However, standard treatment has not been established. ■Case report A 48-year-old male with right side homonymous hemianopia by a left occipital-parietal lobe hemorrhage was treated with Qu-Ji-Du-Huang-Wan, acupuncture and electroacupuncture for 20 days. We used confrontation visual field exam, automated perimetry and visual analog scale for evaluating symptoms. Following treatment, confrontation visual field exam and the subjective discomfort was improved. ■Conclusions The present case report suggests that combined Korean medicine treatment might be an effective treatment of post-stroke homonymous hemianopia. A number of follow up studies should be conducted to clarify the effectiveness of treatment.

Design and Fabrication of Base Station Antenna for ETCS based on DSRC (DSRC 기반의 ETCS 기지국 안테나 설계 및 제작)

  • Ko Jin-Hyun;Kim Nam-Ki;Ha Jae-Kwon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.3 no.1 s.4
    • /
    • pp.75-83
    • /
    • 2004
  • This paper describes the design, fabrication, and measurement of a low side lobe antenna for RSE base station of the ETCS which is one of the ITS services. The antenna is installed on the gantry of road side and provides the wireless communication lint between vehicles and RSE. The required characteristics of ETCS base station antenna are low sidelobe and specific beam pattern by the road and install environment and installed place of OBU. To minimize the affects of multipath signal by reflection, Circular polarization is required. To get low sidelobe of antenna, array configuration and weighting factor by Taylor distribution in radiator elements are applied. The measured results of fabricated antenna are as follows; return loss of 130MHz by -10dB, an axial ratio of 2.6dB, and a gain of 17dBi. It is found that the measured beam patterns are similar to design results.

  • PDF

Design of Small Antennas for Direction Finding Applications (방향 탐지용 소형 안테나 설계)

  • Cho, Chi-Hyun;Oh, Seung-Sub;Choo, Ho-Sung;Park, Ik-Mo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.8
    • /
    • pp.913-921
    • /
    • 2007
  • In this paper, we propose a novel small antenna for direction finding applications. The proposed antenna employs a skirt type disk to eliminate the radiation null on the broad-side direction in the high frequency range. Additionally, the multi-section matching stub is used for impedance matching in the low frequency range, The size of the proposed antenna is reduced as a half of the 60cm dipole which has a same resonance frequency of 200MHz. The antenna maintains a donut shape radiation pattern with a broad beam width for a wide range of frequency while the 60cm dipole shows radiation nulls on the broad-side direction and the high side-lobe level from 700MHz to 1,300MHz.

Trapping and A4-A4 end-to-side anastomosis for the treatment of a ruptured A3 fusiform aneurysm: Potential risk of in-situ bypass

  • Young Rak Kim;Sung Ho Lee;Jin Woo Bae;Young Hoon Choi;Eun Jin Ha;Kang Min Kim;Won-Sang Cho;Hyun-Seung Kang;Jeong Eun Kim
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.1
    • /
    • pp.62-68
    • /
    • 2023
  • The treatment of complicated anterior cerebral artery aneurysms remains challenging. Here, the authors describe a case of ruptured complicated A3 aneurysm, which was treated with trapping and in-situ bypass. A 47-year-old man presented to the emergency department with severe headache and vomiting. Computed tomography illustrated acute intracerebral hemorrhage in the right frontal lobe. Digital subtraction angiography (DSA) confirmed a ruptured fusiform A3 aneurysm with lobulation and a daughter sac. Trapping of the ruptured fusiform A3 aneurysm and distal end-to-side A4 anastomosis was performed. DSA on postoperative day 7 showed mild vasospasm to the afferent artery. However, 2 months later, DSA demonstrated that the antegrade flow through the anastomosis site had recovered. Thus, surgeons should be aware of the possibility of postsurgical vasospasm of anastomosed arteries, especially in cases of ruptured aneurysms.

The Nuclear Medical Study on the Effect of LI4 Acupucture on Cerebral Blood Flow (좌측(左側) 합곡(合谷) 자침(刺鍼)이 뇌혈류(腦血流)에 미치는 영향(影響)에 관한 핵의학적(核醫學的) 고찰(考察))

  • Oh, Hee-Hong;Byun, Jae-Yung;Kim, Il-Du;Ahn, Soo-Gi;Mun, Hyung-Cheal;Hwang, Woo-Jun;Lee, Geon-Mok;Lee, Byung-Chul;Cho, Jae-Woon;Yang, Gui-Bee
    • Journal of Acupuncture Research
    • /
    • v.18 no.4
    • /
    • pp.46-54
    • /
    • 2001
  • Objective : To study correlation of the brain areas with acupoints used in the treatment of cerebrovascular diseases to evaluate the hypothesis that selecting acupoints on the left side to treat disorders on the right side and vice versa is known as the crossing combination of acupoints. Materials and Methods: Rest/acupuncture-stimulation Tc-99m ECD brain SPECT using a same-dose subtraction method was performed on 5 normal male volunteers (age range from 27 to 30 years) using acupuncture at acupoint, LI4 located in the left hand. In the control study, needle location was chosen on a non-meridian focus 1cm posterior to the right fibular head. All images were spatially normalized and the differences between rest and acupuncture stimulation were statistically analyzed using SPM(R) for Windows(R). Results : Acupuncture applied at LI4 located in the left hand increased rCBF in the right hemisphere, that is, the right parietal lobe(angular gyrus) and a part of the right middle posterior temporal gyrus and the right inferior occipital lobe. In the control stimulation, no significant rCBF increase was observed. Conclusion : The results demonstrated a correlation between stimulation at acupoint with increase in rCBF to the controlateral hemisphere.

  • PDF

Analysis of the Radiation Patterns of Satellite SAR System with Active-Transponder (능동전파반사기를 이용한 위성 SAR 시스템 방사 패턴 분석)

  • Hwang, Ji-Hwan;Kweon, Soon-Koo;Oh, Yisok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.10
    • /
    • pp.1204-1211
    • /
    • 2012
  • Measurement and analysis results of the extracted radiation-patterns from the field-experiments which were conducted to acquire the generic technology for calibration and validation of the satellite SAR system(Synthetic Aperture Radar) are presented in this study. Prototype of active transponder is adjustable within maximum 63.1 dBsm of RCS (Radar Cross Section) and includes the receiving-function with external receiver. To increase an accuracy of these field experiments, we repetitively measured satellite SAR systems of the same operating mode(i.e., COSMO-SkyMed No. 2 & 3, hh-pol., strip-map himage mode, 3 m resolution). Then, the reliability of experimental results was cross-checked through analysis of the RCS of active transponder on SAR image. The property of azimuth radiation patterns of satellite SAR system extracted from them has $0.352^{\circ}$ of HPBW(half-power beamwidth), $0.691^{\circ}$ of FNBW(first-null beamwidth), and 11.17 dB of PSLR(peak to side lobe ratio), respectively.

Computer-Aided Diagnosis of Liver Cirrhosis using Wave Pattern of Spleen in Abdominal CT Imaging (복부 CT영상에서 비장의 웨이브 패턴을 이용한 간경변의 자동 진단)

  • Seong Won;Cho June-Sik;Noh Seung-Moo;Park Jong-Won
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.6
    • /
    • pp.532-541
    • /
    • 2005
  • We examined the wave pattern of the spleen by using abdominal CT images of a patient with liver cirrhosis, and found that they are different from those of a person with a normal liver. In the abdominal CT image of the patient with liver cirrhosis, there is a deep wave part on the left side of the spleen. In the case of the normal liver, there are waves on the left side, but they aren't deep. Therefore, the total area of waving parts of the spleen with liver cirrhosis is found to be greater than that of the spleen with the normal liver. Moreover, when examining circularity by abstracting the waves of the spleen from the image with liver cirrhosis, we found they are more circular than those of the spleen accompanied by a normal liver. This paper suggests an automatic method to diagnose liver cirrhosis by using the wave pattern of the spleen in abdominal CT images on the basis of the two principles. It tells us that we can judge if the liver has liver cirrhosis automatically, without the manual test of the ratio of caudate lobe to right lobe, only with the spleen.

Design of a 1 × 2 Array Microstrip Antenna for Active Beam Compensation at X-band (X-밴드 능동적 빔 보상 1 × 2 배열 마이크로스트립 안테나 설계)

  • Choi, Yoon-Seon;Woo, Jong-Myung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.2
    • /
    • pp.111-118
    • /
    • 2016
  • This paper presents an X-band (9.375 GHz) $1{\times}2$ array microstrip antenna which is capable of active beam compensation for installation of an unmanned aerial vehicle (UAV). First of all, a basic $1{\times}2$ array microstrip antenna incorporated with wilkinson power divider was designed and performance of the array antenna was verified. Next, to verify beam steering performance of the designed array microstrip antenna, we fabricated a phase shifter, and the wilkinson power divider as module structure and measured characteristics of beam steering according to phase shifting. The main lobe is 0.6 dBi at $0^{\circ}$, and the side lobe decreased 18.8 dB. The reliable radiation pattern was achieved. Finally, an active beam steering microstrip array antenna attached with the phase shifter and the power divider on the back side of the antenna was designed and fabricated to install wing of UAV for compactness. The maximum gain is 0.1 dBi. Therefore, we obtained a basic antenna technology for compensating beam error according to wing deformation of an UAV installed array antennas.

Assessment of Resistance Spot Weldability of Dissimilar Joints of Austenitic Stainless Steels/IF Steels and Ferritic Stainless Steels/IF Steels (페라이트계 및 오스테나이트계 스테인리스강과 IF강의 이종 접합부의 저항 점 용접성 평가)

  • Lee, Jin-Beom;Kim, Dong-Cheol;Nam, Dae-Geun;Kang, Nam Hyun;Kim, Soon-Kook;Yu, Ji-Hun;Rhym, YoungMok;Park, Yeong-Do
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.1
    • /
    • pp.64-72
    • /
    • 2011
  • The spot weldability of dissimilar metal joints between austenitic stainless steels (STS316)/IF steels and ferritic stainless steels (STS430)/IF steels was investigated. This study was aimed to determine the spot welding parameters for a dissimilar metal joint and to evaluate the dissimilar metal joint's weldability, including its welding nugget shape, tensile-shear strength, hardness, and microstructure. The comparison of these results was described in terms of fracture behavior. Compared with the weld lobe of similar metal joints, dissimilar metal joints (STS430/IF) had reduced weld current range. However, the weld lobe of STS316/IF steel joint showed increased weld current range. This is because the dilution of chemical composition in the molten weld pool suppressed the heat input being caused by Joule heat with current flow through the samples. The microstructure of the fusion zone was fully martensite and mixture of ferrite and martensite for austenitic stainless steel/IF steel and ferritic stainless steel/IF steel combination, respectively. The experimental results showed that the shape of nugget was asymmetric, in which the fusion zone of the austenitic and ferritic stainless steel sheet was larger due to the higher bulk-resistance. The predicted microstructure by using the Schaeffler diagram was well matched with experimental results. After peel test, the fracture was initiated from heat affected zone of ferritic stainless steel sheet side, however the final fracture was propagated into the IF steel sheet side due to its lower strength.