• Title/Summary/Keyword: side friction factor

Search Result 76, Processing Time 0.027 seconds

A Study for Distribution Methods Between Superelevation and Side Friction Factor Reflecting Ergonomic Characteristics by Increasing Design Speed (설계속도 상향에 따른 인간공학적 특성을 반영한 편경사와 횡방향마찰계수 분배방법에 관한 연구)

  • Jeong, Seungwon;Kim, Sangyoup;Choi, Jaisung;Kim, Hongjin;Jang, Taeyoun
    • International Journal of Highway Engineering
    • /
    • v.15 no.3
    • /
    • pp.103-115
    • /
    • 2013
  • PURPOSES: The purpose of this study is to develop a method for distribution between superelevation and side friction factor by increasing design speed. METHODS: First of all, a method for distribution between superelevation and side friction factor and a theory for the functional formula of side friction factor in compliance with horizontal radius applied in South Korea and the United States are considered. Especially, design speed of 140km/h and numerical value of design elements are applied to the theory for the functional formula of side friction factor in AASHTO's methods. Also, the anxiety EEG upon running speed is measured to reflect ergonomic characteristics through field experiments at seven curve sections of the West Coast Freeway, and this data is applied to graph for the functional formula of side friction factor. RESULTS : Matching side friction factor against the anxiety EEG, the results that a critical points of driver's anxiety EEG sharply increase locate under existing parabola are figured out. CONCLUSIONS : Therefore, we could get a new type of the functional formula that driver's driving comfortability is guaranteed if the existing the functional formula of side friction factor goes down under boundary of the critical points of the anxiety EEG.

Air-side Heat Transfer and Friction Characteristics of Fined-tube Heat Exchangers under Heating Condition (핀-관 열교환기의 난방운전 시 공기측 열전달 및 마찰특성)

  • Kwon, Young Chul;Chang, Keun Sun;Ko, Kuk Won;Kim, Young Jae;Park, Byung Kwon
    • Applied Chemistry for Engineering
    • /
    • v.17 no.5
    • /
    • pp.476-482
    • /
    • 2006
  • An experimental study has been performed to investigate the characteristics of air-side heat transfer and friction of a fined tube heat exchanger under heating conditions. Air enthalpy calorimeter was used to obtain the performance evaluation and analysis of the fined tube heat exchanger. Eight finned tube heat exchangers with slit fin, louver fin, and plain fin were used. The air-side heat transfer coefficient was calculated by the log-mean-temperature-difference. Air-side heat transfer and friction were presented in terms of j factor and friction factor on Reynolds number. From the experimental result, it was found that the variations of air-side heat transfer and friction of fined tube heat exchanger with the change of the fin configuration, row number, fin pitch, and tube circuit were obtained. j factor and friction factor decreased with Reynolds number increased. The tube circuit affected the air-side heat transfer and friction. In the case of slit and louver fin, j factor of 1st row was higher than that of 2nd row. But, with increasing Re, j factor was reversed. The characteristics of j factor and friction factor of 2nd row heat exchanger were different according to the kind of fins.

Interfacial Friction Factor in Arrested Saline Wedge (정상염수(定常塩水)쐐기에 있어서의 계면저항계수(界面低抗係數)의 평가(評價))

  • Lee, Moon Ock;Murota, Akira
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.9 no.1
    • /
    • pp.53-62
    • /
    • 1989
  • In order to determine the form and the length of saline wedge, it is necessary to evaluate interfacial friction factor. Hetherto one dimensional two-layer flow model which assumed pressure as the hydrostatic pressure distribution has been well used to the calculation of saline wedge form, it just then stands in need of relevant interfacial friction factor. For example, in the case where we calculate back to interfacial friction factor out of saline wedge form obtained at a laboratory open channel with comparatively narrow width, it is needed to correct the side-wall effect of a channel, if generally negligible in the river. In this study, we confirmed the influence of a side-wall upon the lateral velocity distributions at laboratory channel and then examined in detail the value of interfacial friction factor in the case where it was corrected by the side-wall effect and not corrected. And then we make clear the influence of a side-wall upon the arrested saline wedge and interfacial faction factor from these results.

  • PDF

An Experimental Study on the Effect of the Air Temperature on the Air-Side Heat-Transfer Coefficient and the Friction Factor of a Fin-and-Tube Heat Exchanger (외기 온도 변화가 핀-관 열교환기의 공기측 열전달계수와 마찰계수에 미치는 영향에 관한 실험적 연구)

  • Kim, Nae-Hyun;Cho, Honggi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.4
    • /
    • pp.149-158
    • /
    • 2017
  • In general, the air-side j and f factors of evaporators or condensers are obtained through single-design tests performed under air-dry and wet-bulb temperatures. Considering that the indoor or outdoor air temperatures vary significantly during the operation of an air conditioner, it is necessary to confirm that the experimentally-obtained j and f factors are widely applicable under variable air conditions. In this study, a series of tests were conducted on a two-row slit-finned heat exchanger to confirm the applicability. The results showed that, for the dry-surface condition, the changes of the tube-side water temperature, water-flow rate, and air temperature had virtually no effect on the air-side j and f factors. For the wet condition, however, the f factor was significantly affected by these changes; contrarily, the j factor is relatively independent regarding this change. The formulation of the possible reasoning is in consideration of the condensation behavior underneath the tube. The wet-surface j and f factors are larger than those of the dry surface, with a larger amount for the f factor.

Effect of Side Friction on Consolidation Test of Normally Consolidated Kaolinite Slurry (정규압밀된 연약점토의 압밀시험시 측면 마찰의 영향)

  • Lee, Jangguen;Fox, Patrick J.
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.3
    • /
    • pp.61-68
    • /
    • 2008
  • Side friction is often neglected in the analysis of the results of a consolidation test when the specimen has a high ratio of diameter to height. As the height of a specimen increases, however, side friction becomes important. This paper presents an investigation of the effect of side friction on consolidation test results for normally consolidated kaolinite slurry. Consolidation tests were performed to obtain settlement, pore pressure, compressibility, and hydraulic conductivity of kaolinite slurry. The compressibility relationship is corrected for side friction using a modified form of Taylor (1942) analytical solution. Numerical simulations using the CS2 piecewise-linear model are compared with settlement and excess pore pressure measurements. Experimental results show improved agreement with a modified CS2 model in which the effect of side friction is considered. The numerical and experimental results indicate that the side friction is an important factor affecting the rate of consolidation as well as the compressibility relationship for the specimen.

  • PDF

A Study on Beat Transfer Characteristics in the Air Side of Large-scaled Heat Exchanger (확대모형 열교환기를 이용한 공기측 열전달 성능에 관한 연구)

  • Byun Ju-Suk;Lee Jinho;Hong Man-Gi;Jeon Chang-Duk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.9 s.240
    • /
    • pp.1032-1041
    • /
    • 2005
  • This study is performed to investigate the heat transfer characteristics of heat exchanger according to the arrangement of fins as well as fin configuration by using the four times enlarged model. Friction factor, Colburn j factor and goodness factors are compared to each other to estimate performance of each case for 4 different kinds of fins, which are plain, single side slit, double side slit and louver fin. Results show that heat transfer would be altered by fin arrangement and that friction loss is more affected by fin configurations than by the fin arrangements. In particular, heat transfer depends more on the shape of front row than that of rear row. The heat transfer rate of combined fin arrangement increases a lot more under the same pressure drop than that of conventional fin arrangement. This indicates that the heat exchanger of higher efficiency would be designed by the proper combination of fins, of different shapes.

Evaluation of Air-side Heat Transfer and Friction Characteristics on Design Conditions of Evaporator (증발기의 설계조건에서 공기측 열전달계수 및 압력강하 산출)

  • 김창덕;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1007-1017
    • /
    • 2003
  • An experimental study on the air-side pressure drop and heat transfer coefficient of slit fin-tube heat exchanger has been carried out. The data reduction methodology for air-side heat transfer coefficients in the literature is not based on a consistent approach. This paper focuses on new method of data reduction to obtain the air-side performance of fin-tube heat exchanger using R22 and recommends standard procedures for dry and wet surface heat transfer estimation in fin-tube heat exchanger having refrigerant on the tube-side. Results are presented as plots of friction f-factor and Colburn j -factor against Reynolds number based on the fin collar outside diameter and compared with previous studies. The data covers a range of refrigerant mass fluxes of 150∼250 kg/$m^2$s with air flows at velocity ranges from 0.3 m/s to 0.8 m/s.

Evaluation of Air-side Heat Transfer and Friction Characteristics on Design Conditions of Condenser (응축기의 설계조건에서 공기측 열전달계수 및 압력강하 산출)

  • 김창덕;전창덕;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.3
    • /
    • pp.220-229
    • /
    • 2003
  • An experimental study on the air-side pressure drop and heat transfer coefficient of slit fin-tube heat exchanger has been carried out. The data reduction methodology for air-side heat transfer coefficients in the literature is not based on a consistent approach. This paper focuses on new method of data reduction to obtain the air-side performance of fin-tube heat exchanger using R22 and recommends standard procedures for dry surface heat transfer estimation in fin-tube heat exchanger having refrigerant on the tube-side. Results are presented as plots of friction f-factor and Colburn j -factor against Reynolds number based on the fin collar outside diameter and compared with previous studies. The data covers a range of refrigerant mass fluxes of 150~250 kg/$m^2$s with air flows at velocity ranges from 0.6 m/s to 1.6 m/s.

Air-side Heat Transfer and Friction Characteristics of Finned Tube Beat Exchangers with Slit Fin or Plain Fin (슬릿과 평판 핀-관 열교환기의 공기측 열전달 및 마찰특성)

  • Kwon, Young-Chul;Chang, Keun-Sun;Park, Byung-Kwon;Kwon, Jeong-Tae;Jeong, Ji-Hwan
    • Journal of Energy Engineering
    • /
    • v.16 no.1 s.49
    • /
    • pp.7-14
    • /
    • 2007
  • An experimental study is performed to investigate the effect of air-side heat transfer and friction on characteristics of finned tube heat exchanger under dry surface and wet surface conditions (RH 50%, 70%). Air enthalpy calorimeter is used to obtain the performance evaluation and analysis of a fined tube heat exchanger. Four finned tube heat exchangers with slit fin or plain fin are tested. The number of tube rows are 2 and 3, and the tube diameter is 7 mm. Air-side heat transfer and friction are presented in terms of j factor and friction factor. At dry surface condition, j factor decreases with increasing Re and j factor of 3 row is lower than that of 2 row. Also, the friction factor of a slit fin is larger than that of a plain fin. At wet surface condition, the heat transfer effect is more significant in the case of the slit fin than the plain fin and 2 row than 3 row. The j factor and friction factor are affected by humidity, tube row and fin configuration.

Heat Transfer and Friction Behaviour in a Channel with an Inclined Perforated Baffle

  • Krishna Putra, Ary Bachtiar;Ahn, Soo-Whan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.2
    • /
    • pp.70-76
    • /
    • 2008
  • The effects of the inclined perforated baffles on the distributions of the local heat transfer coefficients and friction factors for air flows in a rectangular channel were determined for Reynolds numbers from 23,000 to 57,000. Four different types of the baffle are used. The inclined baffles have the width of 19.8cm, the square diamond type hole having one side length of 2.55cm, and the inclination angle of $5^{\circ}$, whereas the corresponding channel width-to-height ratio was 4.95. Results show that the heat transfer and friction factor depend significantly on the number of baffle holes and Reynolds number. The friction factor decreases with increasing Reynolds number and the number of holes on the baffle, and the heat transfer performance of baffle type II (3 hole baffle) has the best value.