• Title/Summary/Keyword: shunt calibration

Search Result 9, Processing Time 0.025 seconds

A calibration of high current measuring sensors by comparison tests (비교 시험에 따른 대전류 측정 센서 교정 결과 분석)

  • Han, Jong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.312-313
    • /
    • 2015
  • For the traceability of high current measuring sensors of high power testing department II(HPTD II) in Korea Electrotechnology Research Institute(KERI), additional comparison tests with reference test object were performed repeatedly. The first intercomparison has been carried out between the reference shunt for Asia and high current shunt of HPTD II in 2013. This paper compares the test results of the calibration in 2014 with them in 2015. The assigned new scale factor of high current sensors will be applied to high power tests in HPTD II until the next high current intercomparison.

  • PDF

Development of High Current Shunt Regulator for Beam Based Alignment in PLS 2GeV Storage Ring (포항방사광가속기 빔위치 정렬 용 정밀전원장치 개발)

  • Nam, S.H.;Suh, J.H.;Ha, K.M.;Huang, J.Y.;Ko, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2249-2251
    • /
    • 1997
  • Total 144 quadrupole magnets are installed in PLS. The magnets are connected in series with groups of two or 24. Each group is powered by a high-precision constant-current DC power supply. For the purpose of the beam based alignment of beam position monitors in the PLS, it is necessary to adjust the current of each quadrupole independently. To achieve this, a high current shunt regulator is designed. It can shunt a maximum 50 A of the quadrupole magnet current. The shunt regulator is programmable and the current amplitude can be varied linearly with a 12-bit resolution. Power transistors are used in the current shunt regulator. The operation of transistors is in linear region. The RS232C protocol is used for remote control and status report of the shunt regulator to the main control centre of the PLS. Preliminary result indicates that the calibration accuracy of the beam position monitor can be achievable in less than $10{\mu}m$.

  • PDF

Precise Measurement of High Current Shunt Resistance (대전류 분류기 저항의 정밀측정)

  • Kim K.-T.;Han K.-S.;Kwon S.-W.;Kim M.-S.;Jeong J.Y.;Kim I.S.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.9
    • /
    • pp.403-406
    • /
    • 2005
  • Precise measurement of extremely low resistance shunt is important for characterization and calibration of high current instruments. We tested resistance measurement method for extremely high current shunt (up to 140 kA), where resistance is determined by precise measurement of voltage drop at 10 A test current in the frequency range of 40 Hz to 10 kHz. For the extremely low ac voltage to be precisely measured, a verification of the measurement method was also carried, where the inherent noise is systematically evaluated. The measurement uncertainty was estimated to be $1\;\%\;at\;95\;\%$ confidence level (k=2) for about 50 $\mu\Omega$.

Implementation of cost-effective wireless photovoltaic monitoring module at panel level

  • Jeong, Jin-Doo;Han, Jinsoo;Lee, Il-Woo;Chong, Jong-Wha
    • ETRI Journal
    • /
    • v.40 no.5
    • /
    • pp.664-676
    • /
    • 2018
  • Given the rapidly increasing market penetration of photovoltaic (PV) systems in many fields, including construction and housing, the effective maintenance of PV systems through remote monitoring at the panel level has attracted attention to quickly detect faults that cause reductions in yearly PV energy production, and which can reduce the whole-life cost. A key point of PV monitoring at the panel level is cost-effectiveness, as the installation of the massive PV panels that comprise PV systems is showing rapid growth in the market. This paper proposes an implementation method that involves the use of a panel-level wireless PV monitoring module (WPMM), and which assesses the cost-effectiveness of this approach. To maximize the cost-effectiveness, the designed WPMM uses a voltage-divider scheme for voltage metering and a shunt-resistor scheme for current metering. In addition, the proposed method offsets the effect of element errors by extracting calibration parameters. Furthermore, a design method is presented for portable and user-friendly PV monitoring, and demonstration results using a commercial 30-kW PV system are described.

On-Site Evaluation Technique of Current Transformer Comparator System (전류변성기 비교측정 장치의 현장 평가기술)

  • Jung, Jae-Kap;Lee, Sang-Hwa;Kwon, Sung-Won;Kang, Jeon-Hong;Kim, Myung-Soo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.926-932
    • /
    • 2007
  • A recently developed methods for on-site calibration of the current transformer (CT) comparator system have been reviewed in the paper. The method utilizes several traveling standards, which consist of the CT, non-reactive standard resistors, wide ratio error CT, and shunt resistors. The traveling CT is used for absolute evaluation of a standard CT belonging to industry. The non-reactive standard resistors and a wide ratio error CT are used for the linearity check of errors in the current comparator. The shunt resistors are used for evaluation of CT burden of industry.

Calibration of micro-ohm shunt used for large current measurement (대전류 측정용 마이크로-옴 분류기의 교정에 관한 연구)

  • Kim, M.K.;Kim, I.K.;Jeong, J.Y.;Kim, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1862-1864
    • /
    • 2002
  • In this study, micro-ohm shunts with rated ac current of 2, 20, 80kA intended for use as an approved system for ac current measurement were calibrated according to IEC 60060. The scale factor and linearity were determined by comparison with the reference measuring system. Measurements of temperature rise due to the rated current was also investigated to analyze a temperature effect. One of the main goals was the determination of the measurement uncertainty of the shunt. The expanded uncertainty of the scale factor for the complete measuring system was satisfied with the STL(Short-circuit Testing Liaison) guide recognized tentatively.

  • PDF

Study on Torque precision measuring System using Curve Fitting Algorithm (커브피팅 알고리즘이 적용된 토크 정밀 측정 시스템 개발에 관한 연구)

  • Lee, Ki Won;Ha, Jae Seung;Kang, Seung Soo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.8 no.4
    • /
    • pp.1-11
    • /
    • 2012
  • This paper is the study on the development of a torque precision measuring system using the curve fitting algorithm. This system can be divided into the hardware part and the software part. The hardware part consists of the main base board, the DAQ(Data Aquisition) board and Calibration parts. The software part consists of the software filter module and the curve fitting algorithm module. We have tested the torque transducer including the strain gauge for 200 Nm range and have analyzed the data acquired with the curve fitting algorithm by using this system. The DAQ board converts the electric signal induced by the transducer to the digital value precisely by using the shunt calibration procedure. The main board including the curve fitting algorithm calculates the exact digital torque value by using the digital value from the DAQ board. In this study, we confirmed that the result of the appropriate high-order power-series polynomial function is more accurate than the result of the low-order power-series polynomial through the system.

Experimental Study of Hydroelastic Behaviors of VLFS Considering Breakwaters (방파제를 고려한 초대형 부유식 해상구조물의 유탄성 응답 특성에 관한 실험적 연구)

  • 신현경;이형락;유경훈;윤명철;강점문;김화수
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.41 no.1
    • /
    • pp.31-39
    • /
    • 2004
  • In this paper, an experimental study on the hydroelastic behaviors of a VLFS with L=5,000m was made considering a breakwater. The principal dimensions of the VLFS model were 9m${\times}$1.8${\times}$0.0108m(L${\times}$B${\times}$D) and the length of breakwater was 12.6m (1.4L). The distance between the VLFS and the breakwater varied from B/2 to 28. The wide tank test results were compared with the numerical predictions and the comparison showed a little gap along its longitudinal axis, in spite of using the very small model size due to the scale 1/555.5

Develoment of high-sensitivity wireless strain sensor for structural health monitoring

  • Jo, Hongki;Park, Jong-Woong;Spencer, B.F. Jr.;Jung, Hyung-Jo
    • Smart Structures and Systems
    • /
    • v.11 no.5
    • /
    • pp.477-496
    • /
    • 2013
  • Due to their cost-effectiveness and ease of installation, wireless smart sensors (WSS) have received considerable recent attention for structural health monitoring of civil infrastructure. Though various wireless smart sensor networks (WSSN) have been successfully implemented for full-scale structural health monitoring (SHM) applications, monitoring of low-level ambient strain still remains a challenging problem for WSS due to A/D converter (ADC) resolution, inherent circuit noise, and the need for automatic operation. In this paper, the design and validation of high-precision strain sensor board for the Imote2 WSS platform and its application to SHM of a cable-stayed bridge are presented. By accurate and automated balancing of the Wheatstone bridge, signal amplification of up to 2507-times can be obtained, while keeping signal mean close to the center of the ADC span, which allows utilization of the full span of the ADC. For better applicability to SHM for real-world structures, temperature compensation and shunt calibration are also implemented. Moreover, the sensor board has been designed to accommodate a friction-type magnet strain sensor, in addition to traditional foil-type strain gages, facilitating fast and easy deployment. The wireless strain sensor board performance is verified through both laboratory-scale tests and deployment on a full-scale cable-stayed bridge.