• Title/Summary/Keyword: shock loading

Search Result 164, Processing Time 0.025 seconds

Data Analysis of International Joint Road and Sea Transportation Tests Under Normal Conditions of Transport (국제공동 육해상 정상운반시험의 데이터 분석)

  • Lim, JaeHoon;Cho, Sang Soon;Choi, Woo-seok
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2_spc
    • /
    • pp.275-289
    • /
    • 2020
  • In 2017, multimodal transportation tests for evaluating road, sea, and rail transport were performed by research institutes in the US, Spain, and the Republic of Korea. In this study, acceleration and strain data determined through road and sea tests were analyzed. It was investigated whether the load generated for each transport mode was amplified or attenuated according to the load transfer path. From the results, it was confirmed that the load transfer characteristics differed according to the transportation mode and loading path. The effects of strain determined through each test on the structural integrity of the spent nuclear fuel were also investigated. It was found that the magnitude of the measured strain had a negligible effect on the structural integrity of the spent nuclear fuel, considering its fatigue strength. The results for the acceleration and strain data analyses obtained in this study will be useful for scheduled domestic transportation tests under normal transport conditions.

Elasto-Plastic Behaviors of Composite Beam using Shear Connectors installed in Driving Pins (드라이빙핀전용 전단연결재를 이용한 합성보의 탄소성 거동)

  • Yang, Il-Seung;Oh, Young-Ho;Lee, Man-Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.1
    • /
    • pp.73-80
    • /
    • 2012
  • The adoption of a composite beam system is regarded as a simple but effective solution because it improves the overall stiffness, strength and stability of the structure by welding shear studs. However, welding shear studs poses problems including electric shock and weld defects. Mechanical methods have emerged as an alternative to metallurgical methods for connecting the H-beam and shear connector. Four specimens were tested in order to compare the structural behavior of the proposed composite beams with that of the classical composite beam given the condition of horizontal loading. With the original composite beam (FCB-SB specimen) using stud bolts, hysteresis loops are stable, but its strength decreased with the crashing of the concrete slab around the column. The suggested composite beams using shear connectors also yielded stable hysteresis loops. Consequently, use of the suggested composite beams instead of the original composite beam are recommended.

An Experimental Study on the Treatment of Organic Wastewater by Soil Microbes Using Three-phase Fluidized Bed (삼상유동층 반응기에서 토양미생물에 의한 유기성 폐수처리에 관한 연구)

  • Choung, Youn Kyoo;Chun, Yang Kun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.207-217
    • /
    • 1992
  • In this study, isolated and cultured nitrogen fixed microbes were seeded in the three-phase fluidized bed in which gas, solid and liquid were contacted directly. Input velocity was varied from 8.12 cm/hr to 16.32 cm/hr. And upflow gas pressure was fixed to 80 psi. Return ratios were from 0.2 to 0.6 with the each experimental condition. According to these condition, movement of media, growth of biofilm and removal efficiency were measured. As the results, in case of briquette ash, biofilm was developed to $170{\mu}m$ when velocity was 8.12 cm/hr and return ratio was 0.6. In this condition, COD removal efficiency was 97% and $NH_4$-N removal efficiency was 83%. At the same condition, biofilm thickness of glass bead was $17.59{\mu}m$ and its COD and $NH_4$-N removal efficiency was 83% and 72%. Nitrogen fixed microbes have following characters: it formed dark-brownish sludge, excellent adhesive force, easy solid-liquid separation and low oxygen uptake ratio, but sensitive to DO concentration. Not only it endured shock loading, but required short time to steady state.

  • PDF

Treatment of Benzene Vapor Gas with Compost and Calcium Silicate Porous Biofilters (퇴비 및 규산칼슘계 다공성 바이오필터의 벤젠휘발가스 처리)

  • Park, Joon-Seok;Namkoong, Wan;Kim, Sun-A;Park, Young-Goo;Lee, Noh-Sup
    • Journal of the Korean Applied Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.21-27
    • /
    • 2005
  • This study was conducted to evaluate the biofiltration treatment characteristic for benzene vapor gas. Compost and calcium silicate porous material were used as biofilter fillers. Gas velocity and empty bed retention time were 15 m/hr and 4 min, respectively. Benzene gas removal efficiency of P-Bio (calcium silicate porous material with inoculation) was the highest and maintained in over 98%. After shock input of benzene gas, the removal efficiency of P-Bio biofilter was recovered within 2 days, while 5 days were taken in CP-Bio (compost + calcium silicate porous material mixture with inoculation) and CP (compost + calcium silicate porous material mixture without inoculation) biofilters. The removal efficiency of P-Bio biofilter was near 100% in the loading rate of <$85g/m^3$(filling material)/hr, It was shown that the maximum elimination capacities of P-Bio, CP-Bio, and CP biofilters were 95, 69, and $66\;g/m^3$(filling material)/hr, respectively. Microbial number of P-Bio, which the number was the lowest at start-up, was 3 orders increased on operational day 48. $CO_2$ was generated greatly in order of P-Bio, CP-Bio, and CP biofilters.

Comparative behaviour of stiffened and unstiffened welded tubular joints of offshore platforms

  • Thandavamoorthy, T.S.
    • Steel and Composite Structures
    • /
    • v.3 no.5
    • /
    • pp.321-331
    • /
    • 2003
  • The paper presents the results of an experimental investigation conducted on welded tubular joints, that are employed in offshore platforms, to study the behaviour and strength of these joints under axial brace compression loading. The geometrical configuration of the joints tested were T and Y. The nominal diameter of the chord and brace members of the joint were 324 and 219 mm respectively. The chord thickness was 12 mm and the brace 8 mm. The tested joints are approximately quarter size when compared to the largest joints in the platforms built in a shallow water depth of 80 m in the Bombay High field. Some of the joints were actually fabricated by a leading offshore agency which firm is directly involved in the fabrication of prototype structures. Strength of the internally ring-stiffened joints was found to be almost twice that of the unstiffened joints of the same configuration and dimensions. Bending of the chord as a whole was observed to be the predominant mode of deformation of the internally ring-stiffened joints in contrast to ovaling and punching shear of the unstiffened joints. It was observed in this investigation that unstiffened joint was stiffer in ovaling mode than in bending and that midspan deflection of unstiffened joint was insignificant when compared to that of the internally ring stiffened joint. The measured midspan deflection of the unstiffened joint in this investigation and its relation with the applied axial load compares very well with that predicted for the brace axial displacement by energy method published in the literature. A comparison of the measured deflection and ovaling of the unstiffened joint was made with that published by the author elsewhere in which numerical prediction of both quantities have been made using ANSYS software package. The agreement was found to be quite good.

Module Design and Performance Evaluation of Surge Arrester for Loading In Railway Rolling Stock (전철 탑재형 피뢰기의 모듈설계 및 성능평가기술)

  • Cho, H.G.;Kim, S.S.;Han, S.W.;Lee, U.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2038-2040
    • /
    • 2000
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for AC power system of railroad vehicles. Metal oxide surge arrester for most electric power system applications, electric train and subway are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of ZnO elements in a surge arrester occurs due to flashover, fault short current flows through the arrestor and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise. etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion. The main research works are focused on the structure design by finite element method, pressure relief of module, and studies of performance of surge arrester for electric railway vehicle.

  • PDF

Validation study on numerical simulation of RC response to close-in blast with a fully coupled model

  • Gong, Shunfeng;Lu, Yong;Tu, Zhenguo;Jin, Weiliang
    • Structural Engineering and Mechanics
    • /
    • v.32 no.2
    • /
    • pp.283-300
    • /
    • 2009
  • The characteristic response of a structure to blast load may be divided into two distinctive phases, namely the direct blast response during which the shock wave effect and localized damage take place, and the post-blast phase whereby progressive collapse may occur. A reliable post-blast analysis depends on a sound understanding of the direct blast effect. Because of the complex loading environment and the stress wave effects, the analysis on the direct effect often necessitates a high fidelity numerical model with coupled fluid (air) and solid subdomains. In such a modelling framework, an appropriate representation of the blast load and the high nonlinearity of the material response is a key to a reliable outcome. This paper presents a series of calibration study on these two important modelling considerations in a coupled Eulerian-Lagrangian framework using a hydrocode. The calibration of the simulated blast load is carried out for both free air and internal explosions. The simulation of the extreme dynamic response of concrete components is achieved using an advanced concrete damage model in conjunction with an element erosion scheme. Validation simulations are conducted for two representative scenarios; one involves a concrete slab under internal blast, and the other with a RC column under air blast, with a particular focus on the simulation sensitivity to the mesh size and the erosion criterion.

Wet Drop Impact Response Analysis of CCS in Membrane Type LNG Carriers -I : Development of Numerical Simulation Analysis Technique through Validation- (멤브레인형 LNG선 화물창 단열시스템의 수면낙하 내충격 응답해석 -I : 검증을 통한 수치해석 기법 개발-)

  • Lee, Sang-Gab;Hwang, Jeong-Oh;Kim, Wha-Soo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.6
    • /
    • pp.726-734
    • /
    • 2008
  • While the structural safety assessment of Cargo Containment System(CCS) in membrane type LNG carriers has to be carried out in consideration of sloshing impact pressure, it is very difficult to figure out its dynamic response behaviors due to its very complex structural arrangements/materials and complicated phenomena of sloshing impact loading. For the development of its original technique, it is necessary to understand the characteristics of dynamic response behavior of CCS structure under sloshing impact pressure. In this study, for the exact understanding of dynamic response behavior of CCS structure in membrane Mark III type LNG carriers under sloshing impact pressure, its wet drop impact response analyses were carried out by using Fluid-Structure Interaction(FSI) analysis technique of LS-DYNA code, and were also validated through a series of wet drop experiments for the enhancement of more accurate shock response analysis technique. It might be thought that the structural response behaviors of impact response analysis, such as impact pressure impulses and resulted strain time histories, generally showed very good agreement with experimental ones with very appropriate use of FSI analysis technique of LS-DYNA code, finite element modeling and material properties of CCS structure, finite element modeling and equation of state(EOS) of fluid domain.

A Study on the Theory and Its Verification of Dynamic Analysis Program (MPDAP) for Modelling of Saturated Multi Phase Porous Media (포화된 다공성 지반의 모델링을 위한 동적해석 프로그램(MPDAP)의 이론 및 이의 검증에 괄한 연구)

  • 김광진;문홍득
    • Geotechnical Engineering
    • /
    • v.13 no.1
    • /
    • pp.5-18
    • /
    • 1997
  • In order to make reliable ground shock predictions in saturated geological media, it is necessary to use multi -phase material models and numerical codes. This paper presents the results of theoretical study of the fundamental behavior of multi-phase porous media subjected to high dynanlic loadings, and deals with the development of numerical code MPDAP with JWL(Jones-Wilkins-Lee) model, which is capable of considering the kinds and characters of explosives. To check the global equilhorium equations of the numerical code, we carried out some verifications. In the cases of the elastic spherical wave propagation in a single phase medium, one-dimensional linear ronsolidation, and one timensional wave propagation in saturated linear elastic soils and rocks, the results calculated by MPDAP show close agreement with closed-form solutions or numerical solutions generated with two phase code.

  • PDF

Design and Performance Evaluation of Surge Arrester for Loading in Railway Rolling Stock (전철 탑재용 피뢰기의 설계 및 성능평가)

  • Cho, H.G.;Han, S.W.;Lee, U.Y.;Kim, S.S.;Chang, T.B.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.74-77
    • /
    • 2000
  • The main objective of this paper is to design and test a new type of polymer ZnO surge arrester for AC power system of railroad vehicles. Metal oxide surge arrester for most electric power system applications, electric train and must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of ZnO elements in a surge arrester occurs due to flashover, fault short current flows through the arrester and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock. pressure rise, etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion. The main research works are focused on the structure design by finite element method, pressure relief of module, and studies of performance of surge arrester for electric railway vehicle.

  • PDF