• Title/Summary/Keyword: shift system change

Search Result 271, Processing Time 0.03 seconds

Fuzzy Control Method of Low Pass Filter of ASK system (ASK 시스템 Low Pass Filter의 퍼지 제어 방식)

  • NamGung, Uk;Jeong, Seong-Boo;Eom, Ki-Hwan
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.217-218
    • /
    • 2006
  • We propose a method for improving the performance of the Amplitude Shift Keying (ASK) system using a fuzzy logic system for automatically tuning the bandwidth of low pass filter. Instead of a fixed bandwidth of a low pass filter of receiver, the fuzzy logic system is used to automatically adjust the bandwidth. The inputs to the fuzzy logic system are the error and change of error, and output is a bandwidth. Simulation results showed that the proposed system improves considerably on the performance of the fixed bandwidth.

  • PDF

Determination of the Wear Limit to the Process Mean Shift Problem with Varying Product and Process Variance (생산량과 공정분산이 변하는 공정평균이동 문제의 마모한계 결정)

  • Lee, Do-Kyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.43 no.3
    • /
    • pp.95-100
    • /
    • 2020
  • Machines and facilities are physically or chemically degenerated by continuous usage. One of the results of this degeneration is the process mean shift. The representative type of the degeneration is wear of tool or machine. According to the increasing wear level, non-conforming products cost and quality loss cost are increasing simultaneously. Therefore a periodic preventive resetting the process is necessary. The total cost consists of three items: adjustment cost (or replacement cost), non-conforming cost due to product out of upper or lower limit specification, and quality loss cost due to difference from the process target value and the product characteristic value among the conforming products. In this case, the problem of determining the adjustment period or wear limit that minimizes the total cost is called the 'process mean shift' problem. It is assumed that both specifications are set and the wear level can be observed directly. In this study, we propose a new model integrating the quality loss cost, process variance, and production volume, which has been conducted in different fields in previous studies. In particular, for the change in production volume according to the increasing in wear level, we propose a generalized production quantity function g(w). This function can be applied to most processes and we fitted the g(w) to the model. The objective equation of this model is the total cost per unit wear, and the determining variables are the wear limit and initial process setting position that minimize the objective equation.

A Chromo- and Fluoroionophoric Thiaoxaaza-Macrocycle Functionalized with Nitrobenzofurazan Exhibiting Mercury(II) Selectivity

  • Lee, Ji-Eun;Lee, Shim-Sung;Choi, Kyu-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.12
    • /
    • pp.3707-3710
    • /
    • 2010
  • A chromo/fluorogenic $NO_2S_2$-macrocycle L functionalized with nitrobenzofurazan unit as a dual-signaling probe was synthesized and structurally characterized by single crystal X-ray analysis. In a cation-induced color change experiment, L exhibited excellent $Hg^{2+}$ ion selectivity by showing the color change from orange-red to yellow. However, this hypochromic shift by $Hg^{2+}$ was observed for the weaker coordinating anion system such as ${NO_3}^-$ and ${ClO_4}^-$ ions. The observed anion effect is due to the strong coordination of anions inhibits the bond formation between $Hg^{2+}$ and the macrocyclic tert-N atom, which is sensitive to induce the color change. In the fluorometric experiment, L showed chelate-enhanced fluorescence change effect only with $Hg^{2+}$ ion, together with a change from yellow to green emission. The sensing ability for $Hg^{2+}$ with the proposed chemosensor L is due to the stable complexation with 1:1 stoichiometry (metal-to-ligand).

Measurement of electron density of atmospheric pressure Ar plasma jet by using Michelson interferometer

  • Lim, Jun-Sup;Hong, Young June;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.195.1-195.1
    • /
    • 2016
  • Currently, as Plasma application is expanded to the industrial and medical industrial, low temperature plasma applications became important. Especially in medical and biology, many researchers have studied about generated radical species in atmospheric pressure low temperature plasma directly adapted to human body. Therefore, so measurement their plasma parameter is very important work and is widely studied all around world. One of the plasma parameters is electron density and it is closely relative to radical production through the plasma source. some kinds of method to measuring the electron density are Thomson scattering spectroscopy and Millimeter-wave transmission measurement. But most methods have very expensive cost and complex configuration to composed of experiment system. We selected Michelson interferometer system which is very cheap and simple to setting up, so we tried to measuring electron density by laser interferometer with laser beam chopping module for measurement of temporal phase difference in plasma jet. To measuring electron density at atmospheric pressure Ar plasma jet, we obtained the temporal phase shift signal of interferometer. Phase difference of interferometer can occur because of change by refractive index of electron density in plasma jet. The electron density was able to estimate with this phase difference values by using physical formula about refractive index change of external electromagnetic wave in plasma. Our guiding laser used Helium-Neon laser of the centered wavelength of 632 nm. We installed chopper module which can make a 4kHz pulse laser signal at the laser front side. In this experiment, we obtained more exact synchronized phase difference between with and without plasma jet than reported data at last year. Especially, we found the phase difference between time range of discharge current. Electron density is changed from Townsend discharge's electron bombardment, so we observed the phase difference phenomenon and calculated the temporal electron density by using phase shift. In our result, we suggest that the electron density have approximately range between 1014~ 1015 cm-3 in atmospheric pressure Ar plasma jet.

  • PDF

The electronic structure of the ion-beam-mixed Pt-Cu alloys by XPS and XANES

  • Lim, K.Y.;Lee, Y.S.;Chung, Y.D.;Lee, K.M.;Jeon, Y.;Whang, C.N.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.133-133
    • /
    • 1998
  • In the thin film alloy formation of the transition metals ion-beam-mixing technique forms a metastable structure which cannot be found in the arc-melted metal alloys. Sppecifically it is well known that the studies about the electronic structure of ion-beam-mixed alloys pprovide the useful information in understanding the metastable structures in the metal alloy. We studied the electronic change in the ion-beam-mixed ppt-Ct alloys by XppS and XANES. These analysis tools pprovide us information about the charge transfer in the valence band of intermetallic bonding. The multi-layered films were depposited on the SiO2 substrate by the sequential electron beam evapporation at a ppressure of less than 5$\times$10-7 Torr. These compprise of 4 ppairs of ppt and Cu layers where thicknesses of each layer were varied in order to change the alloy compposition. Ion-beam-mixing pprocess was carried out with 80 keV Ae+ ions with a dose of $1.5\times$ 1016 Ar+/cm2 at room tempperature. The core and valence level energy shift in these system were investigated by x-ray pphotoelectron sppectroscoppy(XppS) pphotoelectrons were excited by monochromatized Al K a(1486.6 eV) The ppass energy of the hemisppherical analyzer was 23.5 eV. Core-level binding energies were calibrated with the Fermi level edge. ppt L3-edge and Cu K-edge XANES sppectra were measured with the flourescence mode detector at the 3C1 beam line of the ppLS (ppohang light source). By using the change of White line(WL) area of the each metal sites and the core level shift we can obtain the information about the electrons pparticippating in the intermetallic bonding of the ion-beam-mixed alloys.

  • PDF

A Development of the Optimization Model for Reactive Scheduling Considering Equipment Failure (장치이상을 고려한 동적 생산계획 최적화 모델 개발)

  • Ha, Jin-Kuk;Lee, Euy Soo
    • Korean Chemical Engineering Research
    • /
    • v.43 no.5
    • /
    • pp.571-578
    • /
    • 2005
  • We propose a new optimization framework for the reactive scheduling. The proposed rescheduling scheme is specially focused on how to generate rescheduling results when equipment failure occurs. The approach is based on a continuous-time problem representation that takes into account the schedule in progress, the updated information on the batches still to be processed, the present plant state, the deviations in plant parameters and the time data. To update the predictive scheduling, we used right shift rescheduling and total regeneration when equipment failure occurs. And, a practical solution to the rescheduling problem requires satisfaction of two often confliction measures: the efficiency measure that evaluates the satisfaction of a desired objective function value and the stability measure that evaluates the amount of change between the schedules before and after the disruption. In this paper, the efficiency is measured by the makespan of all jobs in the system. And, the stability is measured by the percentage change in makespan and the modified sequence deviation in the predictive scheduling and rescheduling.

Detecting and Counting People system based on Vision Sensor (비전 센서 기반의 사람 검출 및 계수 시스템)

  • Park, Ho-Sik
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.6 no.1
    • /
    • pp.1-5
    • /
    • 2013
  • The number of pedestrians is considered essential information which can be used to control a person who makes a entrance or a exit into a building. The number of pedestrians, also, can be used to help to manage pedestrian traffic and the volume of pedestrian flow within the building. Due to the fact there is incorrect detection by occluded, shadows, and illumination, however, difficulty can arise in existing system which is for detection and counts of a person who makes a entrance or a exit into a building. In this paper, it is minimized that the change of illumination and the effect of shadow through the transmitted image from camera which is created and processed with great adaptability. The accuracy of the calculations can be increase as well by using Kalman Filter and Mean-Shift Algorithm in order to avoid overlapped counts. As a result of the test, it is proved that the count method that shows the accuracy of 95.4% should be effective for detection and counts.

Rapid Detection of Salmonella spp. by Antibody Immobilization with Gold-protein A Complex (Gold-protein A Complex 항체 고정화법을 이용한 Salmonella spp.의 신속 검출)

  • Park, In-Seon;Kim, Nam-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.1-6
    • /
    • 1999
  • A piezoelectric (PZ) biosensor system detecting Salmonella spp. was developed. The system consisted of an oscillator, a frequency counter and an antibody-immobilized quartz crystal. An anti-Salmonella antibody was immobilized on one gold. surface of the quartz crystal with protein A. Salmonella detection was made by measuring resonant frequency shift owing to a mass change by specific binding of microbial cells to the gold surface of the PZ crystal. The PZ antibody sensor was operated optimally at 0.1M phosphate buffer, pH 7.2 and $35^{\circ}C$. The sensor was quite specific to Salmonella spp. The obtained frequency shift was correlated with the Salmonella concentration in the range of $10^5{\sim}10^6\;CFU/mL$. The frequency shift increased further by addition of polystyrene beads. The Salmonella detection which is indicated by a steady-state microbial adsorption to the quartz crystal was accomplished within 50min.

  • PDF

($^{31}P-NMR$ chemical shift variation of O-ethyl ethylphosphonic acid with change of pH's and solvents in metabolic and chemical oxidation of O-ethyl S-methyl ethyphosphonothioate (O-Ethyl S-methyl ethylphosphonothioate의 대사(代謝) 주생성물(主生成物인) O-ethyl ethylphosphonic acid의 $^{31}P-NMR$ chemical shift 에 대한 pH 및 용매 효과)

  • Hur, Jang-Hyun;Han, Dae-Sung
    • Korean Journal of Environmental Agriculture
    • /
    • v.12 no.2
    • /
    • pp.169-175
    • /
    • 1993
  • O-Ethyl S-methyl ethylphosphonothioate was studied for chemical and metabolic oxidation using $^{31}P-NMR$ analyses. The chemical shifts of O-ethyl ethylphosphonic acid (2) which is one of major metabolites were changed with the variation of oxidation systems. $^{31}P-NMR$ chemical shifts of 2 were observed at 40.15ppm from oxidaton by MCPBA, 30.98 ppm by MMPP, 29.31 ppm from in vitro rat liver microsomal oxidation, and 29.10 ppm from in vivo metabolism in houseflies. $^{31}P-NMR$ chemical shift of 2 in two different solvents such as deutero-chloroform and deuterium oxide were observed at 30.70 ppm and 40.15 ppm, respectively. And those of the metabolites were also observed at around 30 ppm under the conditions of pH 3, 5.6 and 14 and 47.91 ppm under pH 1 which is a strong acidic condition. It could be explained that the ionized form of 2 should have greater shielding effect on phosphorus atom and hence shows upfield chemical shift in polar solvents and alkaline conditions. On the other hand, a protonated form under organic solvents and the strong acidic condition should have less shielding effect than its ionized form, shifting the peak downfield.

  • PDF

Phase transformer method and its application (위상변성방식과 그 응용)

  • 오상세
    • 전기의세계
    • /
    • v.13 no.2
    • /
    • pp.1-4
    • /
    • 1964
  • Phase transformation is used to change some phase from phase in A.C. system. We have been used Scott or Fork connection in phase transformation the otherwise phase transformation was constructed from M-G set. From this M-G set, we could make phase shift facilities by mannual. Now, I can derive more easy phase transformation from taking another method. I believe this new phase transformation method in the first thing in the world. And so, I am going to explain about phase transformer construction process. The first, we could devide into equal part of core around the iron core as to be same size. The second, you will make primary and secondary winding on the core. The third, when you will supplied three phase A.C. at the terminal of primary winding you can get e.m.f. inducing of some phase at secondary. And so, we could make phase change from some phase A.C. We can apply this principle in many fields, i.e., freequency changer, phase leader of no use condenser, voltage regulator in keeping balance, and D.C. generator. And more, I will introduce in details concerning main pinciple and theory through following chapter.

  • PDF