• 제목/요약/키워드: shielding device

검색결과 117건 처리시간 0.028초

방음벽 상단소음저감장치의 성능평가 방법에 관한 연구(3) - 시험 및 평가방법의 제안 - (Estimation Method of Noise Reducing Devices Installed on the Noise Barrier(3) - Suggestion of Test and Estimation Method -)

  • 김철환;장태순;강희만;전기성;김동준;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.496-499
    • /
    • 2008
  • The noise reducing devices installed on the noise barrier have been developed in many shapes and ways to reduce noise around road traffic areas. In this study, test and estimation method for the noise reducing device witch installed on the top of a noise barrier was suggested. For this, the authors have considered sound power flow around the device and sound pressure levels for the far field area. To estimate the area effect behind the barrier, area average of noise pressure level difference divided by two area, upper and bellow the sight-line. Comparing the attenuation difference of these areas, the tendency of noise reduction effect was studied according to type of noise reducing devices. Compared with noise shielding efficiency of the devices that using equivalent height of a simple barrier calculated by the SoundPlan, the commercial environment noise simulation software.

  • PDF

자동노출제어장치의 채광창 차폐정도와 농도, 감도의 변화가 관전류량과 영상품질에 미치는 영향 (Effects of Field Configuration Shielding Area and Changing of Density and Sensitivity on Tube Current and Image Quality in Automatic Exposure Control System)

  • 정민규;성열훈
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.635-642
    • /
    • 2020
  • 본 연구에서는 자동노출제어장치(automatic exposure control, AEC)의 채광창 차폐정도와 농도, 감도가 관전류량과 영상품질에 미치는 영향을 분석하였다. 실험에 사용된 장비는 X선관과 간접방식의 디지털검출기가 일체형인 디지털방사선발생장치(Digital Diagnost, Philips, Netherlands)를 사용하였다. 채광창 차폐정도는 3 mm 두께의 납을 이용하여 0%부터 100%까지 12.5%씩 순차적으로 누적 차폐하여 9단계로 구분하였다. 농도는 제조사에서 제시한 3단계(+2.5, 0, -2.5)와 감도 3단계(S200, S400, S800)를 대상으로 하였다. 관전류량 평가는 관전압을 40 kVp로 고정하고 AEC 조절인자들이 교차한 81가지의 조합조건에서 자동 노출된 관전류량을 측정하였다. 영상품질평가는 자체 제작한 원뿔형 피라미드 팬텀의 방사선영상을 육안 평가하여 유효한 영상을 선발하였고 이들의 신호 대 잡음비(signal to noise ratio, SNR)을 측정하였다. 그 결과 관전류량은 채광창 차폐정도가 100%, 감도 S200, 농도 2.5일 때 60.0 mAs로 가장 많이 조사되었으며, 채광창 차폐정도가 0%, 감도 S800, 농도 -2.5일 때 0.9 mAs로 가장 적게 조사되었다. SNR은 채광창 차폐정도가 0%, 감도 S200, 농도 2.5일 때 25.2로 가장 우수하였고, 채광창 차폐정도가 25%, 감도 S800, 농도 -2.5일 때 SNR이 4.7로 가장 낮았다.

임산부의 전뇌 방사선 치료에 있어서의 태아의 방사선량 측정 및 차폐 구조의 설계 (The Evaluation of Radiation Dose to Embryo/Fetus and the Design of Shielding in the Treatment of Brain Tumors)

  • 조웅;허순녕;지의규;하성환;박양균;박종민;박석원
    • Journal of Radiation Protection and Research
    • /
    • 제31권4호
    • /
    • pp.203-210
    • /
    • 2006
  • 목적 : 전뇌 방사선 치료를 받는 임산부의 태아가 받을 선량을 측정하고, 태아의 제한 선량을 적합하게 만족시키기 위한 방사선 차폐 구조물을 설계하고자 한다. 재료 및 방법 : 먼저 4개의 바퀴가 부착된 폭 0.9 m, 높이 1.55 m, 두께 3 cm의 남 차폐 벽을 이용하였다. 남 차폐 벽을 환자와 선형가속기의 갠트리 상부 사이에서, 치료 조사야 경계로부터 1 cm 정도 떨어진 부분에 설치하여, 선형가속기의 갠트리 상부에서 방출되는 누설방사선과, 방사선 조사야 경계부근의 산란 방사선을 효과적으로 차폐하도록 하였다. 환자의 조사야 내의 치료부위로부터 산란되어 전달되는 산란 방사선을 최소로 하기 위하여, 약 2 cm 두께의 세로 벤드(cerrobend)를 이용하여 특수한 구조의 목 차폐대(anti-patient scattering neck supporters)를 성형하였다. 목 차폐대는 목에서부터 어깨와 가슴 상부 전체를 포함하여 차폐할 수 있는 크기로 제작되었으며, 목 부분을 기준으로 두 개로 분리되어 설치 및 운반이 용이하게 제작되었다. 마지막으로 치료실 내부의 구조물에서 산란되어서 들어오는 누설 방사선이 태아에 도달하는 것을 최소한으로 하기 위하여, 환자의 흥부와 복부 전체를 덮어씌우기 위한 3 mm 두께의 납 판 2장을 이용하였으며, 남 판의 무게를 지지하기 위하여 특수하게 고안된 차폐용 교각구조물이 아크릴로 제작되었다. 차폐의 효과를 검증하기 위하여, 먼저 실제 치료상황과 같은 조건에서 인간형 팬톰과 전리함(ionization chamber), 열형광선량계(TLD)를 이용하여 방사선량을 측정하였다. 각 측정은 우선차폐 구조물들이 있는 경우와 없는 경우 각각에 대하여 수행되었고, 각각의 경우는 다시 빌드업캡(build-up cap)이 있는 경우와 없는 경우로 분류하여 측정이 수행되었다. 실제 환자 치료시에는 최종 검증을 위하여 차폐구조물을 설치한 후에 전리함과 서베이메터(Survey meter)를 이용하여 태아선량을 측정하였다. 결과 : 차폐 구조물들을 설치하지 않았을 경우, 조사야로부터 30 cm, 40 cm, 50 cm, 60 cm 떨어진 지점의 방사선량은 전리함의 경우 각각 3.20, 3.21, 1.44, 0.90 cGy로 측정되었다. 차폐 구조물들을 설치하였을 경우에는 각 지점의 방사선량은 0.88, 0.60, 0.35, 0.25 cGy로 감소하였으며, 감쇄효율은 약 $70%\sim80%$로 계산되었다. 열형광선량계로 측정된 방사선량은 각각 1.8, 1.2, 0.8, 1.2, 0.8 (70 cm 거리) cGy로 측정되었으며, 환자의 복부 표면에서의 서베이메터를 이용한 측정량은 10.9 mR/h였다. 차폐구조물의 사용 시 전체 치료 동안에 태아선량은 약 1 cGy 정도로 평가되었다. 결론 : AAPM Report No.50의 자료에 따르면, 임산부의 방사선 치료 시 태아의 방사선 피폭선량은 5 cGy 이하일 경우에 방사선 피폭에 따른 태아의 위험이 거의 없는 것으로 제시되고 있다. 본원에서 차폐 구조물을 설치하였을 경우에 측정된 태아선량은 약 1 cGy로 측정되었고, 고안된 차폐구조물은 태아에 도달하는 방사선량을 감소시키기에 적합한 설계임이 입증되었다.

수술실에서 방사선 차폐기 사용 유무에 따른 공간산란선량분포의 측정 (Measurement of Spatial Scattered Dose Distribution According to Presence or Absence of Radiation Shielding in the Operating Room)

  • 도상록;조평곤;김성진;정동경
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.549-556
    • /
    • 2017
  • 본 연구는 C-arm의 공간산란선량분포를 파악해 보고자, 최근에 개발된 방사선 차폐기의 사용 유무에 따른 공간산란선량분포를 비교하였다. 수평면 분포는 95 cm 높이에서 환자 머리를 기준으로 반경 50 cm 간격으로 $30^{\circ}$씩 증가하였고, 각 수평면의 수직면 내에서 반경 50 cm 간격으로 $30^{\circ}$씩 증가하며 측정하였다. 동일한 방법으로 방사선 차폐기를 설치 후 측정하였다. 측정결과 50 cm 거리 수평면은 $0^{\circ}$, $90^{\circ}$, $180^{\circ}$ 그리고 $270^{\circ}$ 방향에서 $1.77{\pm}0.12$, $1.90{\pm}0.13$, $2.12{\pm}0.14$, 그리고 $2.69{\pm}0.15mSv/h$, 방사선 차폐기 사용 후 $1.59{\pm}0.12$, $0.99{\pm}0.09$, $1.47{\pm}0.11$, 그리고 $1.37{\pm}0.11mSv/h$로 나타났다. 또한, 50 cm 거리 수평 방향 $90^{\circ}$의 수직 분포는 $30^{\circ}$, $60^{\circ}$, $120^{\circ}$ 그리고 $150^{\circ}$에서 $3.85{\pm}0.18$, $9.15{\pm}0.28$, $10.82{\pm}0.31$, 그리고 $5.40{\pm}0.22mSv/h$, 방사선 차폐기 사용 후 각 각 $2.03{\pm}0.13$, $4.32{\pm}0.19$, $2.76{\pm}0.16$, 그리고 $1.92{\pm}0.13mSv/h$이었다. 방사선 차폐기 사용에 따라 각 방향 모두에서 감소하였다. 따라서 수술실에 근무하는 방사선관계종사자는 공간산란선량 분포를 정확히 인지하고 적절한 방호 대책으로 피폭의 위해를 방지하는 노력이 필요하다고 사료된다.

흉부 전산화 단층 촬영 검사 시 발생하는 생식선 차폐 유무에 따른 산란 선량 차이에 관한 연구 (A Study on the Difference of Scattered Rays with or Without Gonadal Shielding During Chest Computed Tomography)

  • 곽종혁;김경립;성현철;김승원;송근성;최민경;이상원
    • 한국방사선학회논문지
    • /
    • 제15권2호
    • /
    • pp.109-115
    • /
    • 2021
  • 생식선 차폐를 하지 않았을 때 전부, 양 측부, 후부, 생식선 부위의 산란선을 측정하고 Xenolite nolead Apron(0.35 mm Pb), Xenolite nolead Apron(front 0.35 mm Pb Mix back 0.25 mm Pb, Skirt overlap), Half Apron(0.5 mm Pb)로 차폐 후 각각의 산란 선량을 측정하였다. 흉부 전산화 단층촬영 검사 시 검사 부위의 산란 선량은 272 μSv가 측정되었고, Apron으로 차폐하지 않았을 시에 평균 전부 43 μSv, 좌측부 81 μSv, 우측부 82μSv, 후부 38.8 μSv, Gonad 부위 16 μSv로 측정되었다. Xenolite nolead Apron으로 위쪽 부분만 차폐하고 측정했을 전부 11.2 μSv, 좌측부 43.1 μSv, 우측부 45.3 μSv, 후부 12 μSv, Gonad 부위 5.2 μSv로 측정되었다. Xenolite nolead Apron(Skirt overlap)으로 Pelvis 부위를 360° 감싼 후 선량을 측정하였을 때 전부 5.6 μSv, 좌측부 22.4 μSv, 우측부 15.7 μSv, 후부 6 μSv, Gonad 부위 3.2 μSv로 측정되었다. Xenolite nolead Apron(Skirt overlap)으로 Pelvis 부위를 360° 감싼 후 선량을 측정하였을 때 전부 5.6 μSv, 좌측부 22.4 μSv, 우측부 15.7μSv, 후부 6 μSv, Gonad 위 3.2 μSv로 측정되었다. Half Apron으로 위쪽만 차폐하고 측정했을 때에는 전부 10.7 μSv, 좌측부 42.6 μSv, 우측부 40.6 μSv, 후부 11.3 μSv, Gonad부위 4.7 μSv로 측정되었다. 골반 부위를 360° 차폐하는 방법이 80% 이상 선량 감소를 보였고, 전부 차폐 시 70% 이상의 선량 감소 효과를 보였으며 모든 전산화 단층 촬영 검사에 있어 피폭선량 경감을 위한 연구와 차폐 가능한 장비를 활용하는 다양한 기법에 관한 지속적인 연구가 필요하리라 사료된다.

Optimum Control of a Photoelectric Dimming System in a Small Office with a Double Skin Envelope

  • Kim, Soo Young;Yum, Sung Kon
    • Architectural research
    • /
    • 제7권2호
    • /
    • pp.47-54
    • /
    • 2005
  • A photoelectric dimming control system for a small private office space with a double skin envelope system was analyzed for the purpose of examining optimum control performances under a variety of daylight conditions. Computer simulations were performed for the three different photosensor types positioned at the center of ceiling in the space. They were applied in both a south and north-facing room. Daylight conditions were a fixed horizontal venetian blind on an external envelope and a retractable shading device on an internal envelope under a clear, intermediate and overcast sky at different times of a day and year. Partially-shielded photosensors provided good control performances providing the required electric light output under clear and intermediate sky conditions. Unshielded photosensors failed to provide necessary illuminance levels producing less electric output and fully-shielded photosensors generally provided excessive light output. Reasonable electric lighting energy savings were achieved except under overcast sky conditions where the control system did not contribute to energy savings due to the less daylight through envelopes. The retractable shading device covering 50% of the internal envelope reduced energy savings up to 19.62%, but the workplane illuminance levels were maintained within recommended ranges. The coefficients of determination between workplane illuminance and photosensor illuminance due to daylight ranged from 0.74 to 0.98. Partially-shielded conditions provided best correlations and the north-facing room yielded stronger correlation than the south-facing room.

전자소자의 3차원 형상최적화를 위한 구조변형 해석을 이용한 새로운 요소망 변형법 (Novel Mesh Regeneration Method Using the Structural Deformation Analysis for 3D Shape Optimization of Electromagnetic Device)

  • Yao Yingying;Jae Seop Ryu;Chang Seop Koh;Dexin Xie
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권6호
    • /
    • pp.247-253
    • /
    • 2003
  • A novel finite element mesh regeneration method is presented for 3D shape optimization of electromagnetic devices. The method has its theoretical basis in the structural deformation of an elastic body. When the shape of the electromagnetic devices changes during the optimization process, a proper 3D finite element mesh can be easily obtained using the method from the initial mesh. For real engineering problems, the method guarantees a smooth shape with proper mesh quality, and maintains the same mesh topology as the initial mesh. Application of the optimum design of an electromagnetic shielding plate shows the effectiveness of the presented method.

용제와 혼합한 금속분말의 $CO_2$ 레이저 클래딩 특성 (Characteristics of $CO_2$ Laser Cladding with High Viscosity Mixed Powder)

  • 김재도;전병철;이영곤;오동수
    • Journal of Welding and Joining
    • /
    • 제19권5호
    • /
    • pp.481-485
    • /
    • 2001
  • Laser cladding processing allows rapid transfer of heat to the material being processed with minimum conduction into base metal. The effect of $CO_2$ laser cladding with high viscosity mixed powders was investigated. High viscosity mixed powder consists of bronze powder and flux that is used at a high temperature condition. The mixed powder has a high viscosity that it can be easily pasted over a curved or slope substrate. The device for mixed powder was designed and manufactured. It consists of the high viscosity mixed powder feeding system, the preheating system and the shielding gas system which prevents the clad layer from being oxidized. The results of experiment indicated that the feed rate of high viscosity mixed powder was important for later cladding with mixed powder feeding. The high viscosity mixed powder and substrate must be preheated to prevent porosity from breaking at the clad layer. The experimental result shows that the high viscosity mixed can be applied for laser cladding process.

  • PDF

광기법을 이용한 고정도 과도전압측정기 (High Quality Transient Voltage Measuring Device Using Optical Technique)

  • 이복희;길경석;전덕규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.441-443
    • /
    • 1995
  • A new optical-resistive voltage divider, which consists of light emitting diode, optic fiber, PIN-photo diode and a high qualify shielding resistive divider, whose total response time is 7.35 [ns], has been obtained. The optical to electrical signal converter was constructed with GaAsP series light emitting diode. The response characteristics have been verified by applying the Marx impulse voltage generator experimentally. Comparing with the performance of conventional resistive voltage divider, the characteristics of the proposed optical-resistive voltage divider are more excellent in step response and less sensitive to electromagnetic interference.

  • PDF

Voltammetric Analysis on a Disposable Microfluidic Electrochemical Cell

  • Chand, Rohit;Han, Dawoon;Kim, Yong-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권4호
    • /
    • pp.1175-1180
    • /
    • 2013
  • A microfabricated electrochemical cell comprising PDMS-based microchannel and in-channel gold microelectrodes was fabricated as a sensitive and a miniature alternative to the conventional electroanalytical systems. A reproducible fabrication procedure enabled patterning of multiple microelectrodes integrated within a PDMS-based fluidic network. The active area of each electrode was $200{\mu}m{\times}200{\mu}m$ with a gap of $200{\mu}m$ between the electrodes which resulted in a higher signal to noise ratio. Also, the PDMS layer served the purpose of shielding the electrical interferences to the measurements. Analytes such as potassium ferrocyanide; amino acid: cysteine and nucleoside: guanosine were characterized using the fabricated cell. The microchip was comparable to bulk electrochemical systems and its applicability was also demonstrated with flow injection based rapid amperometric detection of DNA samples. The device so developed shall find use as a disposable electrochemical cell for rapid and sensitive analysis of electroactive species in various industrial and research applications.