• Title/Summary/Keyword: shedding

Search Result 996, Processing Time 0.024 seconds

Load shedding case study of the refinery plant power system considering dynamic characteristic (정유공장 전력계통 동특성을 고려한 부하차단 적용 사례연구)

  • Lee, Kang-Wan;Lim, Joo-Il;Kim, Hyung-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.61-65
    • /
    • 2000
  • This paper presents the load shedding case studies and recommendations of load shedding scheme For improving the reliability to suit the requirements of LG-Caltex refinery plant power sγstem. It is recommended for LG-Caltex to decrease the total generation for the economic dispatch. When the LG-Caltex refinery is isolated from KEPCO utility system, the proper load shedding scheme should be implemented since total generation in LG-Caltex refinery plant is less than the load demand. According to the studies carried out the logic-based load shedding is recommended as the main protection scheme, with the combination of the under-frequency relay load shedding.

  • PDF

A Study on Decentralized under Voltage Load Shedding Scheme for Preventing Wide-area Black Out (광역정전 예방을 위한 분산형 부하 제어 방안에 대한 연구)

  • Lee, Yun-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • An electric power system sometimes fails because of disturbances that occur unexpectedly, such as the uncontrolled loss of load that developed from cascading blackout. Which make stability through a little of under voltage load shedding should work. The development of phasor measurement unit(PMU) makes network supervision possible. The information obtained from PMU is synchronized by global positioning system(GPS). There are many real-time algorithms which are monitoring the voltage stability. This paper presents the study on the VILS(Voltage Instability Load Shedding) using PMU data. This algorithm computes Voltage Stability Margin Index(VSMI) continuously to track the voltage stability margin at local bus level. The VSMI is expressed as active and reactive power. The VSMI is used as an criterion for load shedding. In order to examine the algorithm is effective, applied to KEPCO system.

Effect of viscoelasticity on two-dimensional laminar vortex shedding in flow past a rotating cylinder

  • Kim, Ju-Min;Ahn, Kyung-Hyun;Lee, Seung-Jong
    • Korea-Australia Rheology Journal
    • /
    • v.21 no.1
    • /
    • pp.27-37
    • /
    • 2009
  • In this work, we numerically investigate the effect of viscoelasticity on 2D laminar vortex dynamics in flows past a single rotating cylinder for rotational rates $0{\leq}{\alpha}{\leq}5$ (the rotational rate ex is defined by the ratio of the circumferential rotating velocity to free stream velocity) at Re=100, in which the vortex shedding has been predicted to occur in literature for Newtonian fluids. The objective of the present research is to develop a promising technique to fully suppress the vortex shedding past a bluff body by rotating a cylinder and controlling fluid elasticity. The predicted vortex dynamics with the present method is consistent with the previous works for Newtonian flows past a rotating cylinder. We also verified our method by comparing our data with the literature in the case of viscoelastic flow past a non-rotating cylinder. For $0{\leq}{\alpha}{\leq}1.8$, the frequency of vortex shedding slightly decreases but the fluctuation of drag and lift coefficient significantly decreases with increasing fluid elasticity. We observe that the vortex shedding of viscoelastic flow disappears at lower ${\alpha}$ than the Newtonian case. At ${\alpha}$=5, the relationship between the frequency of vortex shedding and Weissenberg number (Wi) is predicted to be non-monotonic and have a minimum around Wi=0.25. The vortex shedding finally disappears over critical Wi number. The present results suggest that the vortex shedding in the flow around a rotating cylinder can be more effectively suppressed for viscoelastic fluids than Newtonian fluids.

Inhibitory effects of lysozyme on endothelial protein C 1receptor shedding in vitro and in vivo

  • Ku, Sae-Kwang;Yoon, Eun-Kyung;Lee, Hyun Gyu;Han, Min-Su;Lee, Taeho;Bae, Jong-Sup
    • BMB Reports
    • /
    • v.48 no.11
    • /
    • pp.624-629
    • /
    • 2015
  • Lysozyme protects us from the ever-present danger of bacterial infection and binds to bacterial lipopolysaccharide (LPS) with high affinity. Beyond its role in the activation of protein C, the endothelial cell protein C receptor (EPCR) plays an important role in the cytoprotective pathway. EPCR can be shed from the cell surface, which is mediated by tumor necrosis factor-α converting enzyme (TACE). However, little is known about the effects of lysozyme on EPCR shedding. We investigated this issue by monitoring the effects of lysozyme on phorbol-12-myristate 13-acetate (PMA)-, tumor necrosis factor (TNF)-α-, interleukin (IL)-1βand cecal ligation and puncture (CLP)-mediated EPCR shedding and underlying mechanism. Data demonstrate that lysozyme induced potent inhibition of PMA-, TNF-α-, IL-1β-, and CLP-induced EPCR shedding. Lysozyme also inhibited the expression and activity of PMA-induced TACE in endothelial cells. These results demonstrate the potential of lysozyme as an anti-EPCR shedding reagent against PMA-mediated and CLP-mediated EPCR shedding.

Multi-level UnderVoltage Load Shedding Scheme Considering Rate of Change of Voltage for Voltage Stability (전압 변동률을 고려한 수도권 전압 안정화 다단계 부하차단 적용 방안)

  • Lee, Yun-Hwan;Kim, Tae-Gyun;Kim, Ji-Hun;Lee, Byong-Jun;Kang, Bu-Il;Cho, Jong-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2335-2341
    • /
    • 2009
  • High technique growth of modem times and high industrial facility in consequence of buildings demand for electric power of an extensive scale with stability supply and maintenance of high quality. But, power system always have risk of network contingency. When power system break out disturbance, it circumstantially happen like uncontrolled loss of load developing from of cascading. Severely which would be raised wide area blackout, plan to prevent, which make stability through a little of load shedding and multi-level UnderVoltageLoadShdding should work. This paper presents target, sensitivity of bus voltage have choose appropriating load shedding location and load shedding decision making logic with considering rate of change of voltage have studied multi-level under voltage load shedding scheme. Calculation of rate of change of voltage applied method of least square. As a result, we are studied an dynamic analysis of 2008 summer peak data. We have been known that network analysis is a little development and developing UnderVoltageLoadShedding scheme.

Study on the Unsteady Wakes Past a Square Cylinder near a Wall

  • Kim Tae Yoon;Lee Bo Sung;Lee Dong Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.1169-1181
    • /
    • 2005
  • Experimental and numerical studies on the unsteady wake field behind a square cylinder near a wall were conducted to find out how the vortex shedding mechanism is correlated with gap flow. The computations were performed by solving unsteady 2-D Incompressible Reynolds Averaged Navier-Stokes equations with a newly developed ${\epsilon}-SST$ turbulence model for more accurate prediction of large separated flows. Through spectral analysis and the smoke wire flow visualization, it was discovered that velocity profiles in a gap region have strong influences on the formation of vortex shedding behind a square cylinder near a wall. From these results, Strouhal number distributions could be found, where the transition region of the Strouhal number was at $G/D=0.5{\sim}0.7$ above the critical gap height. The primary and minor shedding frequencies measured in this region were affected by the interaction between the upper and the lower separated shear layer, and minor shedding frequency was due to the separation bubble on the wall. It was also observed that the position (y/G) and the magnitude of maximum average velocity $(u/u_{\infty})$ in the gap region affect the regular vortex shedding as the gap height increases.

A Study on the Determination and Application of the Optimum Load Shedding Schemes (최적부하제한방식의 결정과 운용에 관한 연구)

  • Song, Kil-Yeong
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.1
    • /
    • pp.29-37
    • /
    • 1985
  • During Severe emergencies which result in the case of outage of large generator units, an automatic underfrequency protection scheme can prevent the system frequency from decaying and improve the system stability. This paper presents methods and results of a study on the optimum load shedding scheme which covering as follows. 1) Detail representation of governor model 2) Determination of optimum load shedding amount 3) Selection of action time settings of UFR 4) Comparsson of load shedding programs By this study, the optimum system operating method was recommended for reliable operation of power system.

  • PDF

Tower Flange Design Considering Vortex Shedding (Vortex Shedding을 고려한 Tower Flange 설계)

  • Lee Hyunjoo;Choi Wonho;Lee Seung-Kuh
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.68-71
    • /
    • 2005
  • In the case of wind turbine design, Optimization of tower structure is very important because tower generally takes about $20\%$ of overall turbine cost. In this paper, we calculated wind loads considering vortex shedding, and optimized tower flange using the calculation results. For optimization, we used FEM to analyze structural strength of the flange and blade momentum theory to calculate wind loads.

  • PDF

Experimental studies on possible vortex shedding in a suspension bridge - Part I - Structural dynamic characteristics and analysis model

  • Law, S.S.;Yang, Q.S.;Fang, Y.L.
    • Wind and Structures
    • /
    • v.10 no.6
    • /
    • pp.543-554
    • /
    • 2007
  • The suspension bridge is situated in an area of complex topography with both open sea and overland turbulence characteristics, and it is subject to frequent typhoon occurrences. This paper investigates experimentally the possible vortex shedding events of the structure under high wind and typhoon conditions. A single-degree-of-freedom model for the vibration of a unit bridge deck section is adopted to determine the amplitude of vibration and to estimate the parameters related to the lifting force in a vortex shedding event. The results of the studies are presented in a companion paper (Law, et al. 2007). In this paper, statistical analysis on the measured responses of the bridge deck shows that the vibration response at the first torsional mode of the structure has a significant increase at and beyond the critical wind speed for vortex shedding as noted in the wind tunnel tests on a section model of the structure.

Spore Shedding in Catenella impudica from the Godavari Estuary at Bhiravapalem, India

  • Narasimha Rao, G. Mohan;Rangaiah, G. Subba;Dora, S. V. V. S. N.
    • ALGAE
    • /
    • v.23 no.1
    • /
    • pp.71-74
    • /
    • 2008
  • Catenella impudica (Mont.) J.Ag is an important species for human consumption from estuarine regions of Asia. Seasonal shedding of carpospores and tetraspores was quantified between January and December 2004 for natural populations of C. impudica. Vegetative and tetrasporophytic plants were available throughout the year but gametophytic plants were observed only from September to May. Tetraspore shedding was observed throughout the year and carpospores shedding was noticed only during the months when material was available. Hydrographical conditions of the estuary such as low water temperature and low salinity are correlated to the formation and release of carpospores and tetraspores in C.impudica