• Title/Summary/Keyword: shed amount

Search Result 47, Processing Time 0.027 seconds

A Study on Multi Level Load Shedding Control Scheme Strategy for Stabilization of the Korean Power System (국내 전력계통 안정화를 위한 다단계 부하차단 제어전략 수립에 관한 연구)

  • Lee, Yun-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.4
    • /
    • pp.255-261
    • /
    • 2016
  • Korean Power System are operating a load shedding system to prevent voltage instability phenomenon caused by severe line contingencies. In order to apply the load shedding scheme should be selected a location, amount, delay time. Current load shedding system is load shedding amount that has been calculated in the steady-state analysis to load shed the total amount in first level, load shedding amount calculated in advance, it is possible to perform an unnecessary load shedding. In this paper, set a multi-level load shedding control strategy step-by-step selection of load shedding amount for the prevention of excessive load shedding. In addition, through a voltage resilience analysis of the power system by applying motor load ratio and sensitivity parameter to selection the multi level load shedding ratio and delay time. For this reason, to take advantage of the limit data of interchange power, by utilizing interface power flow data to set a multi-level load shedding control strategy for the stabilization of the Korean Power System.

Effect of Blood Contamination on Vickers Microhardness and Surface Morphology of Mineral Trioxide Aggregate

  • Jaehyun Seung;Seong-Jin Shin;Byounghwa Kim;Ji-Myung Bae;Jiyoung Ra
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.51 no.2
    • /
    • pp.165-175
    • /
    • 2024
  • This study aimed to investigate the effects of blood contamination on the Vickers hardness and the surface morphology of premixed MTA and compare them with the effects on conventional MTA. The Vickers microhardness of Endocem MTA Premixed Regular (EP) and ProRoot MTA (PM) was assessed after immersion in fetal bovine serum (FBS) and saline. Stem cells from human exfoliated deciduous teeth (SHED) were seeded on MTA after immersion in FBS, saline, and deionized water (DW). Cell adhesion patterns and surface morphology were visualized via scanning electron microscopy (SEM). The surface microhardness of EP and PM in FBS was lower than in saline. However, short-term exposure of PM to FBS did not reduce the microhardness compared to saline. Angular crystals formed in water, while rounded crystals with more air voids appeared in FBS. Favorable SHED attachment occurred in all groups. Overall, the surface hardness of EP and PM decreased after FBS exposure, although PM was less influenced. We suggest minimizing the amount of bleeding when using MTA clinically; nevertheless, PM remains an option with more expected blood contamination than EP. In summary, exposure to FBS decreased mechanical performance but allowed cell adhesion for both MTAs, with PM being more resistant to these changes.

Quality and Amount of Morning and Evening Milk of the Bangladesh Baghabarighat Milk Shed Area Throughout the Year

  • Islam, K.M.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.1
    • /
    • pp.92-95
    • /
    • 2001
  • The Baghabarighat Milk Shed Area (BMSA), in Bangladesh belonging to the Bangladesh Milk Producers Cooperative Union Limited (BMPCUL) was selected to study the qualitative and quantitative aspects of dairy milk and to establish a trend throughout the year (July 1995 to June 1990) of milk collected at morning and evening, and daily. The average fat, solids-not-fat (SNF) and total solid (TS) contents of the morning milk were 4.58, 7.75 and 12.33%, respectively, and evening milk contained 5.41, 7.81 and 13.23%. The values for the quality varied (p<0.01) throughout the year without a specific trend. Higher milk collection occured at morning (52.77%) than evening (47.24%), but total yield of fat from morning milk was lower (48.74%) than evening milk (51.26%) due to a lower fat value (4.58%). Yield of SNF (52.57% morning, 47.37% evening) followed the values of the amount of milk collected due to their similar value at morning (7.75) and evening (7.81). Overall, TS yield was 51 and 49% from morning and evening. There was not a significant (p>0.01) relationship between fat and TS values of morning milk with those of evening milk, but there was a correlation (p<0.01) between milk yield at morning and all other parameters for evening. Solids-not-fat value of morning milk was related with yield and SNF value of milk from evening, but not with fat and TS evening milk. It may be concluded that evening milk contains higher amounts of fat, SNF and TS, but yields were higher at morning, except fat. Milk collected at morning showed a relationship with all the parameters found at evening.

Sensitivity Studies on Thermal Margin of Reactor Vessel Lower Head During a Core Melt Accident

  • Kim, Chan-Soo;Kune Y. Suh
    • Nuclear Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.379-394
    • /
    • 2000
  • As an in-vessel retention (IVR) design concept in coping with a severe accident in the nuclear power plant during which time a considerable amount of core material may melt, external cooling of the reactor vessel has been suggested to protect the lower head from overheating due to relocated material from the core. The efficiency of the ex-vessel management may be estimated by the thermal margin defined as the ratio of the critical heat flux (CHF)to the actual heat flux from the reactor vessel. Principal factors affecting the thermal margin calculation are the amount of heat to be transferred downward from the molten pool, variation of heat flux with the angular position, and the amount of removable heat by external cooling In this paper a thorough literature survey is made and relevant models and correlations are critically reviewed and applied in terms of their capabilities and uncertainties in estimating the thermal margin to potential failure of the vessel on account of the CHF Results of the thermal margin calculation are statistically treated and the associated uncertainties are quantitatively evaluated to shed light on the issues requiring further attention and study in the near term. Our results indicated a higher thermal margin at the bottom than at the top of the vessel accounting for the natural convection within the hemispherical molten debris pool in the lower plenum. The information obtained from this study will serve as the backbone in identifying the maximum heat removal capability and limitations of the IVR technology called the Cerium Attack Syndrome Immunization Structures (COASISO) being developed for next generation reactors.

  • PDF

Motility and Absorptive Capacity of the Ileum in Acute Hemorrhage (급성실혈시의 회장운동과 흡수기능)

  • Hwang, Jeong-Woon
    • The Korean Journal of Physiology
    • /
    • v.7 no.2
    • /
    • pp.39-47
    • /
    • 1973
  • The influences of the acute hemorrhage on the intestinal functions were studied in the rabbits subjected to acute bleeding, amounting 1.5-2% of the body weight. The motility and the absorptive capacity of the ileum were compared before and after the bleeding. Transfusion of shed blood was also performed in order to see whether the deteriorations were reversible or not. The tension developed in the direction of the longitudinal axis of the ileum was recorded through an appropriate transducer, and the frequency of the rhythmic contraction was counted throughout the procedure. Test solution, 10ml in amount, was placed in the loop of the ileum, and the samples were drawn at zero time and at 20 minutes. Triplicated procedures were repeated on the same loop;namely, before and after bleeding and after transfusion. The test solution was composed of 200 mg% urea, 218 mEq/l of NaCl and 150 mg% of polyethylene glycol (PEG) No. 4,000 in distilled water. The latter substance was used as a marker substance for the volume change of the loop. The results obtained were as follows; 1. The motility of the ileum suffered little effects by acute hemorrhage. However, minor fluctuations were seen in the frequency of the rhythm, showing a slight tendency of decreasing rhythmicity, and it was reversed by transfusion. 2. Diminution of absorptive capacity of urea was noticed in acute hemorrhage and it was interpreted as the consequence of the secondary effect of the retardation of the active transport mechanism governing the sodium transport 3. Absorption rate of the sodium ion was dropped in the hemorrhage, suggesting the indispensable need of the blood supply. 4. Osmolarity of the luminal fluid remained higher in the case of acute hemorrhage. 5. There was a tendency of retaining more fluid in the intestinal lumen in acute hemorrhage, comparing with that observed prior to the bleeding. 6. The deteriorations in the absorptive capacity were restored by transfusion of shed blood.

  • PDF

Evaluation of Internal through Analysis of Airflow and Ventilation of Coal Storage Shed (옥내저탄장 기류 흐름 및 환기량 분석을 통한 내부 유동 평가)

  • Jo, Hyun-Joung;Lee, Jin-Hong
    • Journal of Environmental Impact Assessment
    • /
    • v.31 no.5
    • /
    • pp.334-342
    • /
    • 2022
  • The stringent air environment conservation act forced to build an indoor dome for coal storage. However, it causes some problems due to accumulation of fly ash and harmful substances inside. To solve this problem, this study analyzed the pattern of internal airflow and the amount of ventilation for an indoor coal yard. Overall, the airflow inside the indoor coal yard tended to move to the southwest facing the mountain. In addition, sea-breeze was blowing from the northern louver window facing the sea, where airflow was flowing in. The total flow rate flowing into the indoor coal yard was 918,691 m3/h, and the number of natural ventilation per hour was 0.6 times. Therefore, it is proposed to install a forced ventilation device at the location where internal air flow is concentrated.

A Study on The toad Shedding Application by Adaptive Method for Setting Underfrequency Relays (저주파계전기 정정의 적합한 방법에 의한 부하차단 적용연구)

  • Chung, Jai-Kil;Yoo, Hyun-Jae;Cho, Yang-Haeng
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.61-63
    • /
    • 1993
  • This parer propose an adaptive methodlogy for setting of the underfrequency relays that is based on the initial rate of change of the frequency at the relay. During severe emergencies which result in insufficient power generation to meet load, an automatic load shedding program throughout the affected area can prevent total collapse. To avoid this kind of insufficient power generation, load shedding relays are often applied throughput the system to provide a means of helping balance the load to the remaining generation. Comparing, it has been found that the use of the proposed method for the amount and the timing of load shed more efficiently than the conventional method.

  • PDF

Intraoperative and Postoperative Blood Conservation in Cardiac Surgery (수술중 및 수술후 혈액보존법)

  • 이재원
    • Journal of Chest Surgery
    • /
    • v.27 no.6
    • /
    • pp.451-454
    • /
    • 1994
  • In February 1991 I initiated a blood conservation program that included hemodilution, use of a cell conservation device to concentrate diluted blood from operative field and from mediastinal shed blood, acceptance of a minimal hematocrit level of 25% in stable patients, and strict avoidance of use of blood products without definitive indication. A retrospective study to evaluate the effects of blood conservation program was designed to compare the amount of homologous transfusion, hematologic data, and postoperative outcome in patients operated on before and after initiation of blood conservation program. Patient characteristics were not different between two groups, before[n = 18] and after[n = 42] initiation of the program. The significant decrease of homologous transfusion[5.2 vs 1.4 units] and the marked increase of nontransfused patients[none vs 57%] in experimental group were due to marked decrease in homologous transfusion during the operation[4.6 vs 0.7 unit]. I conclude that with strict intraoperative blood conservation program, cardiac patients can be operated on with minimal homologous transfusion.

  • PDF

Rheographic View of the Change in the Renal Blood Flow in Acute Hemorrhage (Rheogram으로 본 실혈시 신장혈액유통 변화)

  • Chang, Se-Gu;Shin, Dong-Hoon
    • The Korean Journal of Physiology
    • /
    • v.5 no.1
    • /
    • pp.59-69
    • /
    • 1971
  • Studies were undertaken on the changes in the renal blood flow by relating them with the alterations in the amplitudes in the rheogram of rabbits. The changing pattern of the electrical conductivity was recorded by means of the needle electrodes inserted into the kidney and the surrounding aluminium foil which was grounded. The Impedance Rheograph manufactured by the Narco Company was used. The small artifact which persisted after ligation of the renal vessels was subtracted from the value obtained in each pulsatile wave in the rheogram. The animals were nembutalized intravenously, 30 mg/kg. A plastic canule was inserted into the carotid artery and the arterial blood pressure was monitored continuously with the pressure transducer connected to the physiograph. Stepwise bleedings were performed on the animal. The first bleeding was between 13 to 18 ml in the amount, and it was folowed by consecutive hemorrhages, 5 or 10 ml each time. The total amount of bleeding was summed as much as 1.5-2% of the body weight. Two minutes fter each bleeding th arterial blood pressure, ECG and the rheogram were taken. That was the necessary time to obtain the stabilized picture of each parameter. After closing the bleeding process, the shed blood was retransfused into the animal and the response in the renal blood flow was observed as well as the arterial blood pressure. Particularly the presence or absence of the autoregulatory mechanism in the situation of the hemorrhage was also studied. The results obtained were as follows: 1. In 7 cases out of 22, that was about one third of the total number of experiments, the autoregulatory mechanism of the renal blood flow persisted even in acute hemorrhage, and the decreases in the renal blood flow were less than 10% of the control values even when the arterial blood pressure dropped to 66-87% of the original value obtained before the bleeding. 2. Because of the stepwise bleeding the exact blood pressure at which the renal blood flow reduced as much as one third of the control value could not be obtained. However, the results revealed that the approximate pressure, expressed as percentage of the control value, was 50-60% in 3 cases, 61-70% in 4 cases and 71-80% in 8 cases. In one case the decrease in the renal blood flow exceeded one third of the control value before the pressure dropped to 80% of the control. 3. In 19 cases the decreases in the renal blood flow exceeded one half of the control values by hemorrhage. Then the arterial blood pressure revealed less than 40% of the control value in 6-cases. In 2 cases the pressure was 51-60% of the control pressure. In 5 cases the range of bleed pressure was 61-70%, and in e remaining 6 cases the pressure ranged from 71 to 80% of e control value. 4. Out of 15 cases of retransfusion after definite decreases in the renal blood flow loller·ing the hemorrhage, 9 cases restored their renal blood flow. On the contrary 6 cases showed low values even when the shed blood was retransfused. 5. Theories concerning the mechanism of the autoregulation of the renal blood flow were reviewed for the purpose of explanation of the results obtained. However, there are much to be done before greater satisfaction

  • PDF

Economics of Self-Generation by Natural Gas Industry Using the Mixed Integer Program (혼합정수계획법을 이용한 천연가스(LNG) 산업의 자가발전소 건설에 대한 경제성 분석)

  • Lee, Jeong-Dong;Byun, Sang-Kyu;Kim, Tai-Yoo
    • IE interfaces
    • /
    • v.13 no.4
    • /
    • pp.658-667
    • /
    • 2000
  • Seasonal variation of natural gas demand coupled with rigid and stable import pattern of gas represents the characteristic feature of the Korean Liquified Natural Gas(LNG) industry. This attribute has required a huge amount of investment for the construction of storage facility. Thus, to minimize the supply cost, it is legitimate to reduce storage requirement itself. In this study, we combine three alternative methods to deal with the storage requirement to minimize the supply cost. Those are (1) adding additional storage tanks, (2) inducing large firm customers, and (3) constructing gas-turbine self generation facilities. Methodologically, we employ the mixed integer program (MIP) to optimize the system. The model also consider demand and price-setting scheme in separate modules. From the results, it is shown that if alternatives are combined optimally, a number of storage tanks can be reduced substantially compared with the original capacity plan set by the industry authorities. We perform various sensitivity analyses to check the robustness of the results. The methodology presented in this study can be applied to the other physical network industry, such as hydraulics. The empirical results will shed some light on the rationalization of capacity planning of the Korean natural gas industry.

  • PDF