• Title/Summary/Keyword: shear structure

Search Result 2,353, Processing Time 0.087 seconds

Comparison of Shaking Table Test Results and Finite Element Seismic Analysis Results of Shear Wall Structures (전단벽 구조물의 진동대 시험결과와 유한요소 내진해석결과 비교)

  • Kim, Ki Hyun;Jang, Young Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.25 no.3
    • /
    • pp.137-144
    • /
    • 2021
  • In this study, the seismic safety of nuclear power plant structures is evaluated and verified by performing a vibration test on a relatively simple shear wall structure. The shear walls are the prominent members of nuclear power plants and resist the seismic load. The shear wall structure is designed and manufactured to perform shaking table tests and is used to increase the accuracy of the analytical method by comparing them with the numerical analysis results. Different results will be checked and more efficient application methods will be studied depending on the method of designing reinforced concrete structures.

A closed-form solution for a fluid-structure system: shear beam-compressible fluid

  • Keivani, Amirhossein;Shooshtari, Ahmad;Sani, Ahmad Aftabi
    • Coupled systems mechanics
    • /
    • v.2 no.2
    • /
    • pp.127-146
    • /
    • 2013
  • A closed-form solution for a fluid-structure system is presented in this article. The closed-form is used to evaluate the finite element method results through a numeric example with consideration of high frequencies of excitation. In the example, the structure is modeled as a cantilever beam with rectangular cross-section including only shear deformation and the reservoir is assumed semi-infinite rectangular filled with compressible fluid. It is observed that finite element results deviate from the closed-form in relatively higher frequencies which is the case for the near field earthquakes.

A simplified design approach for modelling shear force demand on tower walls supported on a transfer structure in regions of lower seismicity

  • Yacoubian, Mehair;Lam, Nelson;Lumantarna, Elisa;Wilson, John L.
    • Earthquakes and Structures
    • /
    • v.15 no.1
    • /
    • pp.97-111
    • /
    • 2018
  • Buildings featuring a transfer structure can be commonly found in metropolitan cities situated in regions of lower seismicity. A transfer structure can be in the form of a rigid plate or an array of deep girders positioned at the podium level of the building to support the tower structure of the building. The anomalous increase in the shear force demand on the tower walls above the podium is a major cause for concern. Design guidance on how to quantify these adverse effects is not available. In this paper a simplified method for quantifying the increase in the shear force demand on the tower walls is presented. In view of the very limited ductile nature of this type of construction the analysis presented herein is based on linear elastic behaviour.

Damage assessment for buried structures against internal blast load

  • Ma, G.W.;Huang, X.;Li, J.C.
    • Structural Engineering and Mechanics
    • /
    • v.32 no.2
    • /
    • pp.301-320
    • /
    • 2009
  • Damage assessment for buried structures against an internal blast is conducted by considering the soil-structure interaction. The structural element under analysis is assumed to be rigid-plastic and simply-supported at both ends. Shear failure, bending failure and combined failure modes are included based on five possible transverse velocity profiles. The maximum deflections with respect to shear and bending failure are derived respectively by employing proper failure criteria of the structural element. Pressure-Impulse diagrams to assess damage of the buried structures are subsequently developed. Comparisons have been done to evaluate the influences of the soil-structure interaction and the shear-to-bending strength ratio of the structural element. A case study for a buried reinforced concrete structure has been conducted to show the applicability of the proposed damage assessment method.

Study on The Damage Location Detection of Shear Building Structures Using The Degradation Ratio of Story Stiffness (층강성 손상비를 이용한 전단형 건물의 손상위치 추정에 관한 연구)

  • Yoo, Seok-Hyung
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.2
    • /
    • pp.3-10
    • /
    • 2018
  • Damage location and extent of structure could be detected by the inverse analysis on dynamic response properties such as frequencies and mode shapes. In practice the measured difference of natural frequencies represent the stiffness change reliably, however the measured mode shape is insensitive for stiffness change, but provides spatial information of damage. The damage detection index on shear building structures is formulated in this study. The damage detection index could be estimated from mode shape and srory stiffness of undamaged structure and frequency difference between undamaged and damaged structure. For the verification of the observed damage detection method, the numerical analysis of Matlab and MIDAS and shacking table test were performed. In results, the damage index of damaged story was estimated so higher than undamaged stories that indicates the damaged story apparently.

Efficient dynamic analysis of shear wall building structures with various types of openings (다양한 형태의 개구부를 가진 전단벽식 구조물의 효율적 인 동적 해석)

  • 김현수;이승재;이동근
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.329-336
    • /
    • 2003
  • The box system that is composed only of reinforced concrete walls and slabs are adopted on many high-rise apartment buildings recently constructed in Korea. And the framed structure with shear wall core that can effectively resist horizontal forces is frequently adopted for the structural system for high-rise building structures. In these structures, a shear wall may have one or more openings for functional reasons. It is necessary to use subdivided finite elements for accurate analysis of the shear wall with openings. But it would take significant amount of computational time and memory if the entire building structure is subdivided into a finer mesh. An efficient analysis method that can be used regardless of the number, size and location of openings is proposed in this study. The analysis method uses super element, substructure, matrix condensation technique and fictitious beam technique. Three-dimensional analyses of the box system and the framed structure with shear wall core having various types of openings were peformed to verify the efficiency of the proposed method. It was confirmed that the proposed method have outstanding accuracy with drastically reduced time and computer memory from the analyses of example structures.

  • PDF

Hybrid simulation tests of high-strength steel composite K-eccentrically braced frames with spatial substructure

  • Li, Tengfei;Su, Mingzhou;Guo, Jiangran
    • Steel and Composite Structures
    • /
    • v.38 no.4
    • /
    • pp.381-397
    • /
    • 2021
  • Based on the spatial substructure hybrid simulation test (SHST) method, the seismic performance of a high-strength steel composite K-eccentrically braced frame (K-HSS-EBF) structure system is studied. First, on the basis of the existing pseudostatic experiments, a numerical model corresponding to the experimental model was established using OpenSees, which mainly simulated the shear effect of the shear links. A three-story and five-span spatial K-HSS-EBF was taken as the prototype, and SHST was performed with a half-scale SHST model. According to the test results, the validity of the SHST model was verified, and the main seismic performance indexes of the experimental substructure under different seismic waves were studied. The results show that the hybrid simulation results are basically consistent with the numerical simulation results of the global structure. The deformation of each story is mainly concentrated in the web of the shear link owing to shear deformation. The maximum interstory drifts of the model structure during Strength Level Earthquake (SLE) and Maximum Considered Earthquake (MCE) meet the demands of interstory limitations in the Chinese seismic design code of buildings. In conclusion, the seismic response characteristics of the K-HSS-EBFs are successfully simulated using the spatial SHST, which shows that the K-HSS-EBFs have good seismic performance.

Seismic assessment of slender high rise buildings with different shear walls configurations

  • Farghaly, Ahmed Abdelraheem
    • Advances in Computational Design
    • /
    • v.1 no.3
    • /
    • pp.221-234
    • /
    • 2016
  • The present study dictates the behavior of shear wall under a seismic event in slender high rise buildings, and studies the effect of height, location and distribution of shear wall in slender high rise building with and without boundary elements induced by the effect of an earthquake. Shear walls are located at the sides of the building, to counter the earthquake forces. This study is carried out in a 12 storeys building using SAP2000 software. The obtained results disclose that the behavior of the structure is definitely affected by the height and location of shear walls in slender high rise building. The stresses are concentrated at the limit between the shear wall region and the upper non shear wall especially for shear walls without columns. Displacements are doubled between the shear wall region and the upper non shear wall especially for shear walls without columns.

Study on the Seismic Behavior of Precast Concrete Segmental Bridge Piers with Shear Resistance Connecting Structure (전단저항 연결체를 갖는 프리캐스트 세그먼트 교각의 지진거동에 관한 연구)

  • Kim, Tae-Hoon;Kim, Young-Jin;Kim, Seong-Woon;Kim, Chul-Young;Shin, Hyun-Mock
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.85-88
    • /
    • 2008
  • The purpose of this study was to investigate the seismic behavior of precast concrete segmental bridge piers with shear resistance connecting structure. A model of precast concrete segmental bridge columns with shear resistance connecting structure was tested under a constant axial load and a cyclically reversed horizontal load. A computer program, RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology), for the analysis of reinforced concrete structures was used. The proposed numerical method for the seismic behavior of precast concrete segmental bridge piers with shear resistance connecting structure is verified by comparison with reliable experimental results.

  • PDF

Effect of External Acoustic Excitation on Wake behind a Circular Cylinder (외부 음향여기가 원주 후류 유동에 미치는 효과에 관한 연구)

  • Choi, Jae-Ho;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.5
    • /
    • pp.603-609
    • /
    • 1999
  • The effect of an external acoustic excitation on the wake structure behind a circular cylinder was experimentally investigated. The sound wave was excited in the frequency range of the shear layer instability and two sound pressure levels of 114 and 120dB were used in this study. As a result, the acoustic excitation modified the wake structure by increasing the velocity fluctuation energy without changing the vortex shedding frequency. The acoustic excitation enhanced the vortex shedding process and promoted the shear layer instability. Consequently, the acoustic excitation reduced the length of the vortex formation region and decreased the base pressure. In addition, the vortex strength of vortices was increased and the width of the wake was spread out due to the acoustic excitation. When the excitation frequency was identical to the shear layer instability frequency, the effect of the external flow control on the cylinder wake was maximized. In addition, with increasing the sound pressure level, the effect of the external acoustic excitation on the wake structure increased.