• Title/Summary/Keyword: shear structure

Search Result 2,353, Processing Time 0.034 seconds

A Study on the Surface Finishing Technique using Electrorheological Fluid

  • Park, Sung-Jun;Kim, Wook-Bae;Lee, Sang-Jo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.5 no.2
    • /
    • pp.32-38
    • /
    • 2004
  • The electrorheological(ER) fluid has been used to the ultraprecision polishing of single crystal silicon as new polishing slurry whose properties such as yield stress and particle structure changed with the application of an electric field. In this work, it is aimed to find the effective parameters in the ER fluid on material removal in the polishing system whose structure is similar to that of the simple hydrodynamic bearing. The generated pressure in the gap between a moving wall and a workpiece, as well as the electric field-induced stress of the mixture of ER fluid-abrasives, is evaluated experimentally, and their influence on the polishing of single crystal silicon is analyzed. Moreover, the behavior of abrasive and ER particles is described.

Electrorheology of Amine Dispersant Coated Chitosan Phosphate Suspension

  • Choi, Ung-su;Ko, Young-gun
    • KSTLE International Journal
    • /
    • v.3 no.1
    • /
    • pp.23-25
    • /
    • 2002
  • The electrorheological (ER) behavior of amino coated chitosan phosphate suspension in silicone oil is investigated. Amino coated chitosan phosphate suspension shows a typical ER response (Bingham flow behavior) upon application of an electric field due to the polarizability of phosphoryl polar group. The shear stress for the suspension exhibits a linear dependence on an electric field power of 1.94. The values of structure factors $A_s$obtains 2 far mine coated chitosan phosphate suspension and it may be due to the formation of multiple chains upon application of the electric field. Throughtout the experimental results, amino coated chitosan phosphate suspension shows good dispersion stability and found to be an anhydrous ER fluid.

Cyclic Loading Test of Interior Deep-Beam Lower-Column Joint in Upper-shear Wall Lower-Frame Structure (주상복합구조에서 전이보와 내부기둥 접합부의 반복횡하중 실험)

  • 이한선;김상연;고동우;권기혁;최성모
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.446-451
    • /
    • 2000
  • In case of strong earthquake, upper-sheat wall lowe-frame structures show the weak-story failure at lower part. Where we should guarantee sufficient strength, energy dissipation capacity and ductility. In this study, a typical structure was selected for a prototype and four 1:2.5 scaled models, representing the subassemblages including the interior column and the deep beam, were constructed. Experimental parameters include transverse reinforcement ratio and axial force. The non- linear behavior of the subassemblages subjected to the cyclic lateral displac-ement were evaluated through investigation of the ultimate strength, ductility, load-deformation characteristics. From the results of the tests on 4 specimens, it is concluded that the strength increased as the axial force increased and the ductility increased as the transverse reinforcement ratio increased.

  • PDF

A Study on the Safety Assessment of Curved Hollow RC Slab Bridge Structures (곡선형 RC 중공 슬래브교의 안전성 평가 사례 연구)

  • Chai, Won-Kyu;Jo, Byung-Wan;Kim, Kwang-Il
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.6 s.78
    • /
    • pp.96-100
    • /
    • 2006
  • In this thesis, the crack investigation, the damage investigation, the drawing check, and the structural analysis were performed on a curved hollow RC(reinforced concrete) slab bridge structure to assess the structural safety of that. From the crack investigation result, main reason of crack occurrence is guessed with travelling of the large truck. Therefore reinforcement of slab structure is necessary by using the steel plate. When structural analysis, the straight beam model, the curved beam model, and the curved plate model is used. From the results of structural analysis for curved hollow RC slab bridge, the maximum bending moment and the maximum shear force was not a difference in each models. But the vertical displacement of mid span using the curved beam model was greater than that using the other models.

Anti-seismic Capacity Improvement of Underground Box Structures Strengthened with Pressure Bracing (가압식 브레이싱 보강에 의한 지중박스구조물의 내진성능향상 방법)

  • Chung, Jee-Seung;Moon, In-Gi;Min, Dae-Hong
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.4
    • /
    • pp.97-102
    • /
    • 2013
  • This paper presents a new strengthening method of underground box structures against seismic loads for anti-seismic capacity improvement. A threaded steel member with pressure devices(so called 'I-bracing pressure system') is used to improve seismic capacity of the RC box structure. The I-bracing pressure system is fixed the corner of opening after chemical anchor was installed by drilling hole on the box structure. The structural performance was evaluated analytically. Two bracing types of strengthening methods were used; conventional bracing method and improved I-bracing pressure system. For the performance evaluation, seismic analyses were performed on moment and shear resisting structures with and without I-bracing pressure system. Numerical results confirmed that the proposed I-bracing pressure system can enhance the seismic capacity of the underground RC box structures.

Agglomeration effects on the buckling behaviour of embedded concrete columns reinforced with SiO2 nano-particles

  • Zamanian, Mohammad;Kolahchi, Reza;Bidgoli, Mahmood Rabani
    • Wind and Structures
    • /
    • v.24 no.1
    • /
    • pp.43-57
    • /
    • 2017
  • The use of nanotechnology materials and applications in the construction industry should be considered for enhancing material properties. However, the nonlinear buckling of an embedded straight concrete columns reinforced with silicon dioxide ($SiO_2$) nanoparticles is investigated in the present study. The column is simulated mathematically with Euler-Bernoulli and Timoshenko beam models. Agglomeration effects and the characteristics of the equivalent composite are determined using Mori-Tanaka approach. The foundation around the column is simulated with spring and shear layer. The governing equations are derived using energy method and Hamilton's principal. Differential quadrature method (DQM) is used in order to obtain the buckling load of structure. The influences of volume percent of $SiO_2$ nanoparticles, geometrical parameters and agglomeration on the buckling of column are investigated. Numerical results indicate that considering agglomeration effects leads to decrease in buckling load of structure.

Effect of Surface Roughness on Turbulent Concentric Annular Flows (난류 이중동심관 유동에 미치는 표면거칠기 효과)

  • 김경천;안수환;정양범
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.7
    • /
    • pp.1749-1757
    • /
    • 1995
  • The structure of turbulence of fully developed flow through three concentric annuli with both rough inner and outer walls was investigated experimentally for Reynolds number range Re=15000-93000. Turbulence intensities were measured in three (u, v, w) directions, and turbulence shear stresses in annuli of radius ratios .alpha.= 0.26, 0.4 and 0.56, respectively. The result showed that the structure of turbulence for these asymmetric flows was not the same as that for the annulus with smooth walls. The velocity fluctuations of all three components (u, v, and w-directions) showed little discernible variation with Reynolds numbers, but became apparent with the influence of radius ratio (.alpha.) The experimental results for an annulus with the roughened outer wall and a smooth annulus were shown in the figures as a reference. The eddy diffusivities and friction factors were also presented and discussed.

Structure of Premixed Turbulent Flames Stabilized by a Cylinderical Flame Holder (원주 보염기에 의해 안정화된 난류 예혼합 화염의 구조)

  • ;香月正司;水谷幸天
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.4
    • /
    • pp.497-508
    • /
    • 1985
  • 본 논문에서는 일양한 예혼합 기류중에 놓여진 원주 후류의 고온 순환류에 의 해 보지되는 난류 예혼합 화염을 대상으로 해서 유동의 가시화 및 온도와 이온전류의 변동의 측정에 의해서 화염의 구조를 조사한 결과, 원주 보염기 후류의 재순환 영역부 근에 형성된 전단층에 있어서는 코히렌트(Coherent)구조의 화염이 되고 하류부에서는 불규칙한 3차원 와(渦)에 지배되는 전파성 화염이 형성 되었다. 온도변동에 대한 쌍 봉성의 확율밀도분포와 이온전류변동에 대한 3개의 피이크의 확율밀도분포는 엷은 반 응면을 사이에 두고 미연혼합기괴와 기연가스괴가 서로 접하는 주름 상층류화염 또는 층류화염편의 구조에 대응하며, 코히렌트 와(渦)에 지배되는 화염에 있어서는 거시적 혼합은 코히렌트 와의 거동에 지배되나 그 구조는 주름상층류 화염과 일부 강한 전단 력을 받는 부분에는 분산 반응영역의 구조임이 밝혀졌다.

Mechanical Loads Analysis and Control of a MW Wind Turbine (MW 규모 풍력 터빈의 기계적 하중 특성 해석 및 제어)

  • Nam, Yoon-Su;Choi, Han-Soon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.9
    • /
    • pp.26-33
    • /
    • 2010
  • A multi-MW wind turbine is a huge mechanical structure, of which the rotor diameter is more or less than 100 m. Rotor blades experience unsymmetric mechanical loads caused by the interaction of incoming wind with the tower and wind shear effect. These mechanical loads are transferred to the entire structure of the wind turbine and are known as the major reasons for shortening the life span of the wind turbine. Therefore, as the size of wind turbine gets bigger, the mitigation of mechanical loads becomes more important issue in wind turbine control system design. In this paper, a concept of an individual pitch control(IPC), which minimizes the mechanical loads of rotor blades, is introduced, and simulation results using IPC are discussed.

A Study on the Structure of Turbulent Diffusion Flame Behind the Hollowed Flame Holder(II) (중앙분공형 보염기 후류에 안정된 난류확산화염의 구조에 관한 연구(II))

  • Kang, I.G.;Lee, W.S.;Moon, J.K.;Lee, D.H.
    • Journal of Power System Engineering
    • /
    • v.3 no.3
    • /
    • pp.29-35
    • /
    • 1999
  • The purpose of study is to investigate the flame stability and structure of turbulent diffusion flame behind the hollowed flame holder, which is located on the waste gas coming out from the test furnace. PDFs and Power Spectra technique of fluctuating temperature and ion current measurement were needed for this purpose. We discussed that the three types of stabilized flames were found as the result of post study. In this paper, we established the stability mechanism near the flame holder.

  • PDF