• 제목/요약/키워드: shape mismatch

검색결과 41건 처리시간 0.029초

DPCM 음성 부호화기의 부정합현상에 관한 연구 (On the Mismatch Phenomena in DPCM Coding of Speech)

  • 유득수;조동호;은종관
    • 대한전자공학회논문지
    • /
    • 제23권5호
    • /
    • pp.597-604
    • /
    • 1986
  • This paper describes various mismatch phenomena in differential pulse code modulation (DPCM) coding, such as the mismatch effects of probability density functin(pdf), signal variance, and correlation. At a high transmission rate(i.e., above 32 kbits/s), the performance of DPCM can be improved by matching the pdf shape between the input signal and the quantizer. However, the same gain cannot be obtained at a lower transmission rate. Also, it is shown that the gamma quantizer is realtively robust to the variation of pdf shaper and signal variance. Moreover, as the transmission rate increases, the performance of DPCM for the input signal with large variance is worse than that of DPCM for the signal with small variance due to the increase of overload noise. According to our simuladiton results, the mismatch effects of pdf shape and variance appear to yield more degradatin than that of correlation in a DPCM system.

  • PDF

단순봉합모델을 이용한 문합에서 탄성경계층의 두께 변화에 따른 컴플라이언스 부적합에 관한 연구 (The Study on Compliance Mismatch with respect to the Thickness Variation of Elastic Foundation in Anastomosis Using Simplified Suturing Model)

  • 이성욱;심재준;한동섭;한근조;김태형
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1302-1305
    • /
    • 2003
  • In this paper we analyzed the effect of compliance mismatch with respect to the thickness variation of elastic foundation(fatty tissue) in end-to-end anastomosis. This study considered the preliminary deformed shape induced by suturing in the anastomosis of coronary artery and PTFE with different diameters using simplified suturing model and the fatty tissue surrounding heart and coronary artery for more accurate result using finite element method. Area compliance(C$\sub$A/) was used to analyze the final deformed shape of the anastomotic part with respect to the thickness variation of fatty tissue under mean blood pressure, 100 mmHg(13.3kPa). The results obtained were as follows : 1. When the elastic foundation, assumed to be incompressive material, surrounded the grafts in anastomosis, the compliance mismatch of artery and PTFE was improved by 47∼72%. 2. As the initial diameter ratio(R$\sub$I/) became larger, the higher difference of compliance was induced in spite of elastic foundation surrounding grafts.

  • PDF

Assessment of Gradient-based Digital Speckle Correlation Measurement Errors

  • Jian, Zhao;Dong, Zhao;Zhe, Zhang
    • Journal of the Optical Society of Korea
    • /
    • 제16권4호
    • /
    • pp.372-380
    • /
    • 2012
  • The optical method Digital Speckle Correlation Measurement (DSCM) has been extensively applied due its capability to measure the entire displacement field over a body surface. A formula of displacement measurement errors by the gradient-based DSCM method was derived. The errors were found to explicitly relate to the image grayscale errors consisting of sub-pixel interpolation algorithm errors, image noise, and subset deformation mismatch at each point of the subset. A power-law dependence of the standard deviation of displacement measurement errors on the subset size was established when the subset deformation was rigid body translation and random image noise was dominant and it was confirmed by both the numerical and experimental results. In a gradient-based algorithm the basic assumption is rigid body translation of the interrogated subsets, however, this is in contradiction to the real circumstances where strains exist. Numerical and experimental results also indicated that, subset shape function mismatch was dominant when the order of the assumed subset shape function was lower than that of the actual subset deformation field and the power-law dependence clearly broke down. The power-law relationship further leads to a simple criterion for choosing a suitable subset size, image quality, sub-pixel algorithm, and subset shape function for DSCM.

음장 제어의 이론과 그 적용 (Sound manipulation: Theory and Applications)

  • 김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.468-471
    • /
    • 2008
  • Sound manipulation is to control sound field using multiple sound sources for appropriate purposes. In linear acoustics, a sound can be constructed by superimposing several fundamental sound fields such as a planewave and sphere shape sound field. That is how we manipulate sound field. In this paper, we introduce the theory of sound manipulation and its applications from the examples of the generation of fundamental sound field: a circle, a ring shape sound field and a planewave field.

  • PDF

단순봉합모델을 이용한 문합에서 탄성경계층의 두께 변화에 따른 기계역학적 거동에 관한 연구 (The Study on the Mechanical Behavior of the Anastomosis with respect to the Thickness Variation of Elastic Foundation Using Simplified Suturing Model)

  • 이성욱;한근조;심재준;한동섭;김태형
    • 한국정밀공학회지
    • /
    • 제21권8호
    • /
    • pp.188-195
    • /
    • 2004
  • In this paper we analyzed the mechanical behavior with respect to the thickness variation of elastic foundation(fatty tissue) in end-to-end anastomosis. This study considered the preliminary deformed shape induced by suturing in the anastomosis of coronary artery and PTFE with different diameters using simplified suturing model and the fatty tissue surrounding heart and coronary artery for more accurate result using finite element method. Area compliance(CA) was used to analyze the final deformed shape of the anastomotic part with respect to the thickness variation of fatty tissue under mean blood pressure, 100mmHg(13.3㎪). And Equivalent and circumferential stresses in the anastomosis were also analyzed with respect to the change of initial diameter ratio( $R_1$) and fatty tissue thickness( $T_{F}$). The results obtained were as follows : 1 When the elastic foundation, assumed to be incompressive material, surrounded the grafts in anastomosis, the compliance mismatch of artery and PTFE was reduced by 47 -72%. 2. As the initial diameter ratio( $R_1$) became larger, the higher difference of compliance was induced in spite of elastic foundation surrounding grafts. 3. The maximum nondimensional circumferential stress is twice or three times as high as the maximum nondimensional equivalent stress in the anastomotic part.t.

Accuracy of digital and conventional dental implant impressions for fixed partial dentures: A comparative clinical study

  • Gedrimiene, Agne;Adaskevicius, Rimas;Rutkunas, Vygandas
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권5호
    • /
    • pp.271-279
    • /
    • 2019
  • PURPOSE. The newest technologies for digital implant impression (DII) taking are developing rapidly and showing acceptable clinical results. However, scientific literature is lacking data from clinical studies about the accuracy of DII. The aim of this study was to compare digital and conventional dental implant impressions (CII) in a clinical environment. MATERIALS AND METHODS. Twenty-four fixed zirconia restorations supported by 2 implants were fabricated using conventional open-tray impression technique with splinted transfers (CII group) and scan with Trios 3 IOS (3Shape) (DII group). After multiple verification procedures, master models were scanned using laboratory scanner D800 (3Shape). 3D models from conventional and digital workflow were imported to reverse engineering software and superimposed with high resolution 3D CAD models of scan bodies. Distance between center points, angulation, rotation, vertical shift, and surface mismatch of the scan bodies were measured and compared between conventional and digital impressions. RESULTS. Statistically significant differences were found for: a) inter-implant distance, b) rotation, c) vertical shift, and d) surface mismatch differences, comparing DII and CII groups for mesial and distal implant scan bodies ($P{\leq}.05$). CONCLUSION. Recorded linear differences between digital and conventional impressions were of limited clinical significance with two implant-supported restorations.

PbTe 열전재료에 형성된 HgTe 나노개제물의 석출거동: 초기 격자 불일치의 형성, 이론적 계산 및 실험적 증명 (Precipitation Behaviors of HgTe Nanoinclusions Formed in Thermoelectric PbTe: Initial Induced Lattice Mismatch, Theoretical Calculation and Experimental Verification)

  • 김경호;권태형;박수한;안형근;이만종
    • 한국전기전자재료학회논문지
    • /
    • 제24권7호
    • /
    • pp.599-604
    • /
    • 2011
  • A highly strained nanostructure comprising crystallographically aligned HgTe nanoinclusions and a surrounding PbTe matrix has been synthesized using a precipitation process of supersaturated HgTe-PbTe alloys. From the early precipitation stage, HgTe nanoinclusions take disk shape, which is transformed from initial HgTe nuclei, although there is no lattice constant difference of the two end components at standard state. As a primary reason for the morphological transformation of the initial spherical HgTe nuclei to HgTe nanodisks, the induced lattice mismatch is suggested. On the condition that the HgTe nanodisks maintain perfect coherent nature with PbTe matrix, the stress-free lattice constant of constrained HgTe nanodisks has been calculated based on the defined concept of the strain-induced tetragonality, the linear elasticity and the actual measurement in HRTEM images.

탄성경계조직을 가진 관상동맥의 end-to-end 문합에 대한 유한요소해석 (Finite Element Analysis of End-to-End Anastomosis of Coronary Artery with Elastic Surrounding Tissue)

  • 한근조;김태형;안성찬;심재준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집A
    • /
    • pp.442-447
    • /
    • 2001
  • A finite element analysis of end-to-end artery/PTFE anastomosis has been presented in this study to evaluate the distribution of compliance in the vicinity of the anastomosis due to any mismatch in compliance characteristics. But, In these studies it was assumed that the artery and PTFE have the simple cylindrical shape representing the fatty tissue surrounding the coronary artery. And the fatty tissue was considered as the elastic surrounding materials in the finite element analysis. The simulation results were obtained as follows : 1. A fatty tissue was effect to reduce the compliance mismatch in the vicinity of a artery/PTFE anastomosis of different material because a hypercompliant zone become narrorw and a compliance discrepancy decrease between the artery and the PTFE about 70%. And radial direction displacement distribution with respect to distance in the vicinity of a artery/PTFE anastomosis was similiar. 2. The variation of PTFE thckness reduce the compliance mismatch in the vicinity of a artery/PTFE anastomosis about 25%.

  • PDF

초기응력을 가진 기저구조물을 이용한 곡면형 압전 유니모프 개발 (Development of Curved Shape Piezoelectric Unimorph Using Pre-stressed Substrate)

  • 강래형;이종원;한재흥;정상준;고한영
    • 한국소음진동공학회논문집
    • /
    • 제19권1호
    • /
    • pp.94-100
    • /
    • 2009
  • This paper proposes a novel curved shape piezoelectric unimorph using a new fabrication method. Instead of using thermal coefficient mismatch, which has been used for conventional processes for curved shape unimorphs, we used pre-stressed substrates and the room temperature adhesion process. A difference of the mechanical strains between the substrate and the piezoelectric layer makes the final manufactured unimorph get curved. Several performance tests of the proposed unimorph actuators were accomplished and the test results showed the proposed unimorph actuator got comparable actuation capability compared with conventional curved shape actuators.

선형변환 방법에 대한 소고 (A Note on the Hull Form Variational Methods)

  • 이춘주;윤현세;유재문
    • 대한조선학회논문집
    • /
    • 제40권1호
    • /
    • pp.63-68
    • /
    • 2003
  • Systematic geometrical variation method of hull forms, such as "1 -Cp", "Swinging" and "Lackenby" are widely used in the early stage of a new design from those of a similar parent ship, which shows a better performance through the model test and/or sea trials. This method is simple and easy to modify original hull forms without changing the main characteristics. The shape of the prismatic curie can be easily varied by these methods, however, the frame line shape in the body plan can′t be generated easily, when the section shapes are complicated or have discontinuities or the mismatch of the body plan and the stem and stern profiles. To overcome this drawback of the hull form variations, a simple and useful method has been proposed in the present study.