• Title/Summary/Keyword: shade selection

Search Result 41, Processing Time 0.029 seconds

A CORRELATIVE STUDY OF THE EFFECTS OF LIGHT SOURCE, BACKGROUND COLOR, AND TIME SPENT ON THE ABILITY TO MATCH TOOTH SHADE (광원(光源), 배경색(背景色), 소요시간(所要時間)이 치아색(齒牙色) 선택(選擇) 능력(能力)에 미치는 영향(影響))

  • Kwon, Oh-Im
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.38-44
    • /
    • 1978
  • Color is an important factor in dental esthetics. Application of natural tooth color will not fail to produce pleasing results. But a standardized method of shade matching has not been adopted. If we are to overcome the color matching problem in dentistry, an understanding of the nature of color and light is essential. The purpose of this study was to compare the effects of different light sources and different background colors on the ability of observers to correctly match shades of artifical teeth. And observation was made to determine if the time spent in making a shade match was a factor in the correctness of the response. A test method was devised and 50 individuals made observations which were recorded and analyzed. $X^2$-test gave results indicating that the time factor had no effect on the response made. An analysis of variance showed the following effects significant at the five percent level; (1) light source (2) background color (3) subject. The following conclusions can be drawn from this study; (1) The time spent in making shade selection is not a factor in the correctness of the selections. (2) The light source used is an important factor in matching tooth shade; and there is no significant difference between the light sources in shade matching. (3) Under the conditions of this study, the greatest accuracy in shade matching was obtained on the brown background.

  • PDF

Shade comparative analysis of natural tooth measured by visual and spectrophotometric methods (육안과 분광 측정기를 이용한 자연 치아의 색조비교분석)

  • Kim, Bum-Suk;Shin, Soo-Yeon;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.443-454
    • /
    • 2008
  • Statement of problem: A clinically successful color match is one of the important factor to get an esthetic dental restoration. Dental shade guides are commonly used to evaluate tooth color in restorative procedure. But numerous reports have indicated that common shade guides do not provide sufficient spectral coverage of the natural tooth colors. To address issues associated with the shade guide, distinct avenues have been pursued objective spectrophotometric / colorimetric assessment. Purpose: This study compared the accuracy of tooth color selection of spectrophotometer with that of human visual determination. Three main factors were investigated, namely, the effect of light, the individual variation and the experience of the observer. Material and methods: At the first experiment, on ten patients, one operator independently selected the best matching shade to the unrestored maxillary central incisor, using a Vita Classical Shade Guide in the morning, at noon and in the afternoon. The same teeth were measured by means of a reflectance spectrophotometer. At the second experiment, on ten patients, ten operators (5 experts, 5 novices) selected and measured by the same method above at noon. At the third experiment, the results of the second experiment were divided into two groups, expert and novice, and analyzed. Results: 1. There was significant difference between visual and spectrophotometric assessment (mean ${\Delta}E$ values) in experiment 1, 2, 3 (P < .05). 2. There was no significant difference between experts and novices group, when comparing with each visual and spectrophotometric assessment (mean ${\Delta}E$ values). Conclusion: Spectrophotometer could be used to analyze the shade of natural tooth objectively. Thereby, this method offers the potential tominimize considerably the need for corrections or even remakesafter intraoral try-in of restoration. Furthermore, to achieve its advantage, both the shade-matching environment and communication between dentist and technician should be optimized with use of visual and instrumental shade-matching systems.

Evaluation of color matching ability according to the color temperature and the experience of practitioner (색 온도 및 술자의 숙련도에 따른 비색 능력 평가 원저)

  • Kim, Ji-Hyun;Kim, Sun-Jai;Lee, Keun-Woo;Shim, June-Sung;Yoon, Joonho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.4
    • /
    • pp.299-304
    • /
    • 2012
  • Purpose: The aim of this study is to investigate the effect of different experience level and different light source on shade selection ability comparing prosthodontist group and dental student group under 4,000 K and 5,500 K light. Materials and methods: After color difference of Vitapan 3D-master shade guides was measured, 3 sets of 5 shade tabs were selected with similar value but have different chroma (set a, b, c). Also 3 sets of 5 shade tabs were selected with similar chroma but have different values (set d, e, f). Under 4,000 K and 5,500 K light sources, ten prosthodontists and ten dental students were allowed to match in one set of 5 tabs the same shade tab with the tab which was originally selected in the other set of 5 tabs. Color differences of original tab and matched tab were measured by spectrophotometer and the shade selection ability was evaluated with those data. Evaluation of color difference value was performed in regard to different light conditions and different level of experience, followed by t-test with 95% confidence interval. Results: Color difference values under 4,000 K and 5,500 K light source were $1.62{\pm}2.0$, and $1.33{\pm}1.7$ respectively. In addition, color difference values of prosthodontist group and dental student group were $1.34{\pm}1.7$, and $1.61{\pm}2.0$ respectively. Difference of shade selection ability was not found under either different light sources (P=.398), or different experience level (P=.221). Conclusion: Level of experience did not affect on the shade selection ability when prosthodontists and dental students matched the shades with the same shade tab under the same light source.

Working Clothes Design and Production in the Mechatronics Machinery Industry with the Application of Faber Birren's Color Harmony Theory

  • Park, Hye-Won;Yang, Jung-Hee
    • Journal of Fashion Business
    • /
    • v.16 no.3
    • /
    • pp.32-44
    • /
    • 2012
  • This study proposed a color scheme that is harmonious with the working environment of industrial sites using Birren's color harmony theory for color planning. To apply the Birren's color harmony theory to working clothes, the basic colors were chosen, and six of the eight harmony formulas of Birren excluding achromatic colors (white + grey + black) and solid color harmony (solid colors + white + black) were used to form a palette for each case. For the basic colors, the color chips of four dominant colors (yellow-green, sky-blue, blue, and violet), which were chosen from a field survey for preferences in the first step, and the production of materials in the second step were collected through the PANTONE color chips. The selected color chips were PANTONE 13-0550 TPX, PANTONE 15-4105 TPX, PANTONE 18-3949 TPX, and PANTONE 19-3720 TPX. These color chips were scanned and their RGB values were extracted through Photoshop CS. Then the colors were arranged in accordance with the Birren's color harmony formulas (Color+Tint+White, Color+Shade+Black, Tint+Tone+Shade, Shade+Tone+Black, Shade+Tone+White, and Tint+Shade+Tone+Gray). In addition, the proposed palette color schemes were applied through Birren's color harmony formulas using Texpro V 10.1 textile to the schematization of working clothes that were designed in the previous study. Palette formation in line with Birren's color harmony formulas provided scientific color arrangement results. Visually presenting the color scheme of working clothes will help the color selection of working clothes in tune with the circumstances of industrial sites.

Shade Comparative Analysis of Natural Tooth using Spectrophotometric Methods (분광측정기를 이용한 자연 치아의 색조 비교 분석)

  • Kim, Sa-Hak;Hwang, Seong-Sig;Lee, Hye-Eun
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.2
    • /
    • pp.772-781
    • /
    • 2016
  • This study is to set the objective criteria on maxillary incisors shade selection by using the colorimetric Shade-Eye NCC as measuring in CIE $L^*$, $a^*$, $b^*$ values, and look into the meaning by analyzing its values. We explain the purpose of this study and gotten their agreement from patients visiting the dentist, 111 people's (men 50, women 61) three teeth, the maxillary central incisor, maxillary lateral incisor, maxillary canines, total of 333 teeth colorimetry. As a result of comparing the differences in colors between cervical margin and incisal edge, ${\Delta}E^*$ of canine is shown as low as $5.81({\pm}2.98)$, followed by lateral incisor of maxilla as $6.51({\pm}3.23)$ and central incisor of maxilla $7.51({\pm}3.04)$. Females show higher luminosity(L*) than males do in all teeth- central incisor, lateral incisor and canine; in yello chroma(b*) males' central incisor is slightly higher than that of females (p<0.05). Age significantly influences the luminosity and red (a*) and yellow chroma (b*) of central incisor(L*); the luminosity(L*), and yellow chroma(b*) of lateral incisor and canine (p<0.05). Smoking doesn't significantly influence the color of natural teeth. Drinking reduces the luminosity of central incisor as well as red chroma of lateral incisor(p<0.05). A chronic illness is likely to reduce the luminosity of central incisor and lateral incisor(p<0.05).

OPTICAL EFFECTS OF NONMETALLIC POST AND CORE SYSTEMS ON ALL-CERAMIC CROWNS (비금속 포스트 코어가 전부도재관에 미치는 광학적인 영향)

  • Kim Sung-Won;Cho In-Ho;Lim Ju-Hwan;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.5
    • /
    • pp.493-506
    • /
    • 2002
  • Recently as the esthetic concerns about dental prosthesis have been increased, the nonmetallic post and core systems have been introduced clinically to improve the color and the low optical transmittance of conventional casting metal post and core systems. The purpose of this study was to compare and analyze the optical transmittance and the shade changes of all-ceramic crowns with two nonmetallic post and core systems. The experimental groups were classified as follows : Total 27 specimens(9 samples in each group) were evaluated. Group I : Natural teeth as a control group Group II : CosmoPost and $Empress^{(R)}$ core (Ivoclar-Vivadent, Liechtenstein) Group III : $LIGHT-POST^{TM}$ and $LIGHT-CORE^{TM}$ (Bisco, U.S.A.) In all group, all-ceramic crowns were fabricated with the same shade of IPS $Empress^{(R)}$ II (Ivoclar-Vivadent, Liechtenstein) after abutment preparation, and then two kinds of spectrophotometers, UV 3101 PC (Shimadzu, Japan) and CM 503i (Minolta Co. Ltd. Japan), were used to measure the optical transmittance and the color value. The following results were obtained : 1. The optical transmittance of each group without all-ceramic crowns, was siginificantly decreased in order of Group III, I and II (p<0.05). 2. The optical transmittance of each group with all-ceramic crowns cemented, were siginificantly decreased in order of Group I, II and III (p<0.05). 3. In comparison with the shade of all-ceramic crowns, there were no significant differences between groups regardless of the cementation. 4. In comparison with the shade changes in each group after the cementation of all-ceramic crowns, there were no significant differences between groups. From the above results, it is thought that the selection among materials used in this study doesn't influence greatly the esthetic restoration, because the differences of optical transmittance were so small that those were clinically insignificant.

Modeling the Effects of Forest Management Scenarios on Aboveground Biomass and Wood Production: A Study in Mt. Gariwang, South Korea (산림경영활동에 따른 수종별 지상부생물량 및 목재생산량 변화 모델링: 가리왕산 모델숲을 대상으로)

  • Wonhee Cho;Wontaek Lim;Won Il Choi;Hee Moon Yang;Dongwook W. Ko
    • Journal of Korean Society of Forest Science
    • /
    • v.112 no.2
    • /
    • pp.173-187
    • /
    • 2023
  • The forest protection policies implemented in South Korea have resulted in the significant accumulation of forest. Moreover, the associated public interest has also been closely evaluated. As forests mature, there arises a need for forest management (FM) practices, such as thinning and harvesting. It is therefore essential to perform a scientific analysis of the long-term effects of FM. In this study, conducted in Mt. Gariwang, the effect of FM on forest succession and wood production (WP) were evaluated based on changes in aboveground biomass (AGB) using the LANDIS-II model. The FM consists of three scenarios (Selection, Shelterwood, and Two-stories), characterized based on the harvest intensity, frequency, and period. The model was applied to changes in the forest over 200 years. All scenarios show that the total AGB decreased immediately after thinning and harvesting. However, AGB recovery time differed among scenarios, with recovery to preharvest level occurring from 15 to 50 years after harvest; further, after 200 years, harvested forests had a greater total AGB than forests without FMs In particular, the changes in AGB of each species was different depending on its shade tolerance. The AGB of currently dominant shade-intolerant and mid-tolerant species decreased dramatically after harvesting. However, shade-tolerant species, dominant in the understory, continued to grow but were not harvested due to their small size. The cumulative WP for each scenario was estimated at 545.6, 141.6, and 299.9 tons/ha in Selection, Shelterwood, and Two-stories, respectively. The composition of WP differed according to harvest intensity and period. Most WP originated from shade-intolerant and mid-tolerant species in the early period. Later, most WP was from shade-tolerant species, which became dominant. The modeling approach used in this study is capable of analyzing the long-term effects of FM on changes in forests and WP. This study can contribute to decision making to guide FM methods for a variety of purposes, including WP and controlling forest composition and structure.

METAMERISM IN COMPOSITE RESINS UNDER FIVE STANDARD ILLUMINANTS - D65, A, C, FCW AND TL84 (복합레진의 조건등색에 관한 연구)

  • Park, Ki-Jeong;Hwang, Yun-Chan;Kim, Sun-Ho;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.5
    • /
    • pp.402-408
    • /
    • 2003
  • This study was done to present a criterion in selection of the most proper light sources and materials by measuring metamerism index(MI) of the light curing composite resins with spectrocolorimeter. Metamerism is defined when two objects appear to be the same color in one illuminant but different in another. This is due to the fact that they have different spectral curves that fail to match under the second illuminant. In this study, A1 & A3 shade of five light curing composite resins (Esthet-X, Filteck Z250, Filteck A110. Charisma. Vitalescence) were chosen based on Vita shade. Five samples were made for shade of each product with Teflon mold (diameter: 15mm, thickness: 2mm). Metamerism index of each samples on a Barium sulfate plate($L^{*}=96.54,{\;}a^{*}=0.19,{\;}b^{*}=0.01$) prepared for sample fixation were measured with spectrocolorimeter(Miniscan XE plus. Model 4000s. Hunter Lab. USA) by applying standard light source D^{65}, C. Fcw, TL84 and A. Standardization was done with reference standard(X=80.8, Y=85.7, Z=90.8) and light trap. The results were as follows. 1. Different resins with same Vita shade showed recognizable color difference (${\delta}E^{*}>2$). 2. All composites had MI below accepted value 0.5 between standard illuminant(D$_{65}$, C, & A) and below 1.5 under fluorescent condition (Fcw & TL84). 3. MI value between $D^{65}$ and A showed higher value than MI value between other source of light(p<0.01). 4. All resins except Z250 showed MI value that A3 is higher than A1 between $D^{65}$ and A(p<0.05).except Z250 showed MI value that A3 is higher than A1 between $D^{65}$ and A(p<0.05).

CEREC 3D System을 이용한 당일수복 (one-day treatment) 임상증례

  • Jeong, Hyo-Gyeong
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.17 no.1
    • /
    • pp.23-30
    • /
    • 2008
  • Application of CAD/CAM is changing the way partial or full veneer all ceramic restoration is made. CAD/CAM systems, which were used mainly in other industries, have been developed and introduced for the dental purposes recently. It produced a flood of information on the CAD/CAM systems. It also influenced the development of restorative materials and all ceramic is substituting the traditional restorative materials of gold, composite resin and metal. Price increase of gold and other raw materials made the all ceramic more appealing. The introduction of a CEREC 3D system was innovative in several ways. Image of the prepared tooth is captured by camera and impression taking is unnecessary. Restoration can be delivered to the patient on one appointment and it will satisfy the demand of busy patients. One-day treatment with direct CAD/CAM system saves time compared to indirect CAD/CAM system. More superior restoration can be produced if lab work such as the adaptability check and shade selection is cooperated with lab technician. Short working time and comparably superior shade compatibility of color block was close to ideal. In the future, restorations with better quality can be fabricated in less time to busy patients thanks to the development of CAD/CAM system and dental materials.

  • PDF

A Study on the Building Design Guideline Development Considering Photovoltaic Panel Installation (태양광 패널 설치를 고려한 건축 디자인 지침 개발 연구)

  • Moon, Chang-Ho
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.21 no.4
    • /
    • pp.139-146
    • /
    • 2019
  • The purpose of this study is to propose the building design guideline considering photovoltaic panel installation through the analysis of relevant guidelines from home and abroad in terms of building design and solar panel installation. Conclusions can be summarized as followings; Considerations in building design : selection of the site with high solar accessibility, avoidance of the shade from the adjacent building & trees, south facing orientation of solar panel in building design, removal of shade on the solar panel from the part of building itself, load consideration of solar panel & fixing materials, safe passage securement for solar system maintenance, and planning of piping and mechanical room for solar system. Considerations in solar panel installation : harmonizing of solar panel with surrounding environment, unity of solar panel orientation & slope, regular maintenance of solar system, (in case of flat roof installation) solar panel installation afloat over the roof, installation area within the roof floor, and lower than parapet height, (in case of sloped roof installation) solar panel installation parallel with the roof slope, ventilation space securement below the panel, installation area within the roof surface, and similar material installation in empty space.