• Title/Summary/Keyword: sewer flow characteristics

Search Result 56, Processing Time 0.023 seconds

Characterization of Infiltration Analyses Using Long-Term Monitoring Flow Data (장기 모니터링 자료를 활용한 침입수 산정 방법론별 특성 분석)

  • Lee, Jaehyun;Kim, Insop;Oh, Jeill;Park, Chulhwi
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.3
    • /
    • pp.411-418
    • /
    • 2009
  • The analysis of characteristics of water use evaluation and nighttime domestic flow evaluation was performed by using result from flow monitoring and surveying water supply records and nighttime domestic flow for a year. The analysis of correlations showed that, for both sites, the infiltration ratio and wastewater flow have shown a good relationship with high correlation factor and that the calculation of wastewater flow was highly affected by monthly rainfall depth as well as number of rain days. From this result, it was concluded that the measurement of infiltration should be performed when the rainfall does not significantly affect the sewer flow. Also, it is notable that each value of calculated using method for infiltration evaluation are not comparable to each other, but independent methods. In selecting of evaluation method for infiltration, therefore, a great emphasis should be imposed to the character of area and the seasonal factor in order to select optimal one. It is desirable way for evaluating infiltration and reduction ratio using result from an optimal method.

Analysis of the wastewater characteristics variation in sewerage by rehabilitation (관거 정비에 따른 하수발생특성 분석)

  • Jung, SiMon;Park, InHyeok;Park, JungHa;Ha, SungRyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.287-293
    • /
    • 2009
  • The study involved the measurement of flowrate and BOD in the Yeoju area and analyzed annual sewerage data by the I/I analysis technique which is common in Korea. The results of this study are as follows. The I/I for the Y-1 site before maintenance and after the completion of the whole process was reduced from 62% to 16.1% respectively with respect to maximum sewage flow per day. The average quality of water increased. The study measured the Y-2 site from a point of time corresponding to an 80% process rate and its I/I rate went up a little from 8.5% to 11.5%. At the Y-3 site, the I/I rate went up a little from 11% to 13.8%, while little change was noted in the average water quality. At the Y-4 site, the I/I rate was reduced from 43% to 16.9% and its average water quality went up. At the Y-5 site, the I/I quantity went up a little however its average water quality also went up largely. Therefore, it was concluded that the Y-5 site showed great improvement due to the sewer pipe maintenance.

Identifying dominant parameters of storm-sewer-overflows in seperate sewer system (강우시 도시배수구역의 유출특성 지배인자 분석)

  • Jung, Si Mon;Park, In Hyeok;Ha, Sung Ryong
    • Journal of Wetlands Research
    • /
    • v.10 no.2
    • /
    • pp.105-114
    • /
    • 2008
  • Growth in population and urbanization has progressively increased the loadings of pollutants from non-point sources as well as point sources. Separated sewer overflows(SSO) have been considered as a major cause of water-quality deterioration of natural water-courses in the vicinity of the heavily urbanized areas. The factors defining the magnitude and occurrence of SSO are site-specific. It is important to know exact properties of pollutants contained in SSO to address water quality impacts that are caused by SSO inputs to the receiving waters. Site and event parameters found to have significant influences on urban runoff pollutant EMCs include total event rainfall, antecedent dry period, rainfall intensity. In this study, a field survey was carried out in some selected areas of Cheongju city. Literature from previous similar studies was consulted and some important factors affecting the runoff characteristics of urban drainage areas were analyzed for some selected survey points. It was found that the factors most affecting BOD are the number of dry days prior to rainfall and the intensity of the rainfall. The factor most affecting CODcr is the number of dry days prior to rainfall. The factors most affecting SS are the amount of rainfall and the number of dry days prior to rainfall. The factor most affecting TN is the amount of rainfall. The factor most affecting TP is the amount of rainfall and the number of dry days prior to rainfall.

  • PDF

A Study on Process Optimization for CSOs Application of Horizontal Flow Filtration Technology (수평흐름식 여과기술의 CSOs 적용을 위한 공정 최적화 연구)

  • Kim, Jae-Hak;Yang, Jeong-Ha;Lee, Young-Shin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.56-63
    • /
    • 2018
  • The management of Combined Sewer Overflows(CSOs) and Separated Sewer Overflows(SSOs) discharge directly to the effluent system in an untreated state, which occurs when the facility capacity is exceeded due to heavy rain, has become an important issue in recent years as the heavy rain becomes a regular phenomenon. Despite the continuous development of filtration technology, targeting densely populated urban areas, CSOs are rarely applied. Therefore, this study was carried out to optimize the process to apply CSOs in a pilot-scale horizontal flow filtration system with a rope-type synthetic fiber. The research was carried out in two steps: a preliminary study using artificial samples and a field study using sewage. In the preliminary study using an artificial sample, head loss of the filter media itself was analyzed to be approximately 1.1cm, and the head loss was increased by approximately 0.1cm as the linear velocity was increased by 10m/hr. In addition, the SS removal efficiency was stable at 81.4%, the filtration duration was maintained for more than 6 hours, and the average recovery rate of 98% was obtained by air backwashing only. In the on-site evaluation using sewage, the filtration duration was approximately 2 hours and the average removal efficiency of 83.9% was obtained when belt screen (over 450 mesh) was applied as a pre-treatment process to prevent the premature clogging of filter media. To apply the filtration process to CSOs and SSOs, it was concluded that the combination with the pre-treatment process was important to reinforce the hydraulic dimension for the stable maintain of operation period, rather than efficiency. Compared to the dry season, the quality of incoming sewage was lower in the rainy season, which was attributed to the characteristics of the drainage area with higher sanitary sewerage. In addition, the difference in removal efficiency according to the influent quality of the wet season and dry season was small.

An experimental study for estimation of head loss coefficients at surcharged four-way combining manholes (과부하 4방향 합류맨홀에서의 손실계수 산정을 위한 실험 연구)

  • Ryu, Taek Hee;Kim, Jung Soo;Yoon, Sei Eui
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.12
    • /
    • pp.1015-1025
    • /
    • 2016
  • In general, manholes installed as urban drainage facilities are a variety forms such as straight path manholes, 90 degree bend manhole, three-way combining manhole, and four-way combining manhole. In particular, the surcharged flow at a four-way manholes installed in the downstream of urban sewer system is the main cause of the urban inundation caused by the energy loss. Therefore, it is necessary to analyze the flow characteristics and estimate the head loss coefficients at surcharged four-way combining manholes. The hydraulic experimental apparatus which can change the manhole shapes (square, circle) and flow ratios were installed to estimate the head loss coefficients. In the experiments, two inflows ($Q_m$, $Q_{lat}$) were varied from 0 to $4.8{\ell}/sec$ and 24 combinations were tested in total. The flow ratios $Q_{lat}/Q_{out}$ were varied from 0 to 1 for a total flow $Q_{out}$ ($Q_{out}=Q_m+2Q_{lat}$) of 2, 3, 4, and $4.8{\ell}/sec$, respectively. The variation of head losses were strongly influenced by the lateral inflow because the head loss coefficient increases as the flow ratios $Q_{lat}/Q_{out}$ increases. It was estimated head loss coefficients of the circular manhole is slightly lower than those of the square manhole. However, there was no significant difference of head loss as discharges change. The range of head loss coefficients at four-way combining manhole according to the change of the lateral inflow ratio was estimated to be 0.4 to 0.8. Also, the relation equations between the head loss coefficients (K) and the lateral inflow ratios ($Q_{lat}/Q_{out}$) were suggested in this paper.

A Study On Heat Transfer and Flow Characteristics for Boring in Sewer by Rotating Cutter Tool (회전노즐장비 작동시 하수관내의 열전달 및 유동현상에 관한 연구)

  • Park Young-Ki;Lee Jang-Choon;Lee Dong-Joo
    • Journal of Environmental Science International
    • /
    • v.15 no.1
    • /
    • pp.95-100
    • /
    • 2006
  • Heat transfer and flow characteristics in a pipe in which the rotating cutting tool for boring a underground pipe without digging were considered in this study. The amount of heat generation due to the friction between the rotating cutter and pipe wall, mixing (low of air and water injected to cool down are the two important factors to design the boring machine Computational fluid dynamics analysis using the Eulerian mixture model and the standard $\kappa-\varepsilon$ turbulence model was used to analyze the complex phenomena in a pipe during the process. Results show that pipe wall temperature decreased with increasing the cooling water inlet velocity. it is also shown that pipe wail temperature was lowered when the cutter rotation speed was increased until 600 rpm. There was no further cooling effect over 600 rpm.

The Characteristics of Water Quality and the Estimation of Pollutant Loadings from the Flowing Streams in Cheju Island (제주도내 유수하천에 대한 수질특성 및 오염부하량 산정)

  • 조은일;오윤근
    • Journal of Environmental Science International
    • /
    • v.7 no.6
    • /
    • pp.845-851
    • /
    • 1998
  • In order to manage the water quality from the flowing streams in Cheju Island, the characteristics of water quality was investigated from August, 1996 to May, 1997 and the pollutant loadings for future were estimated from the watershed at each stream. Comparing the mean concentrations of each water quality with the criterion of water quality in river, it was under I class except for Changgo Stream, for DO, under I class at the whole station for SS and under II class for BOD. As the pollutant loadings at each stream in 2020 is compared with those in 1996, the estimated results are as follows : 1) for BOD, 59% at Donghong Stream, 24% at Yeonoe Stream, 44% at Ohngpo Stream and 57% at Changgo Stream. 2) for T-N, 91% at Donghong Stream, 76% at Yeonoe Stream, 63% at Ohngpo Stream and 89% at Changgo Stream. 3) for T-P, 69% at Donghong Stream, 42% at Yeonoe Stream, 45% at Ohngpo Stream and 73% at Changgo Stream. The point source loadings discharged through combined sewer could be treated at sewage treatment plant. However, the expected slow decreasing rate of BOD, T-N, and T-P loadings is due to the part of untreated nonpoint source loadings. Nonpoint source loading overflow typically occurs when the flow of stormwater combined with sewage exceeds the capacity of the interceptor sewers. Since most of the sewers used in Cheju Island are the combined sewers, the combined overflow sewage is bypassed into the receiving water area after a rainstorm. Therefore, a means to control nonpoint source loadings should be considered for the river and marine water quality management.

  • PDF

Urban Runoff and Water Quality Models (도시유역에서의 유출 및 수질해석 모형)

  • Lee, Jong-Tae
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.6
    • /
    • pp.709-725
    • /
    • 1998
  • The characteristics of storm and water quality are investigated based on the measuring data of the test river, the Hongje. the water quality of the test river is generally good comparing to other urban rivers in Seoul, because of the interception of sewer flow. But this system makes the river dry up for 3-4 months in winter. On the other hand, in rainy period the storm from the combined sewer system causes rapid increasing pollutants loads. In order to simulate the urban storm and water quality of the trest basin, the models such as SWMM, ILLUDAS, STORM, HEC-1 were applied and the results are compared in its applicability and accuracy aspects. All models discussed here have shown good results and it seems that SUMM is the most effective model in simulating both quantity and quality. Also, regression relations between the water quantity and quality were derived and their applicabilities were discussed. This regression model is a simple effective tool for estimating the pollutant loads in the rainy period, but if the amount of discharge is bigger than measuring range of raw data, the accuracy becomes poor. This model could be supplemented by expanding the range of collecting data and introducing the river characteristics. The HEC-1 would be anther effective model to simulate storm runoff of a river basin including urban area.

  • PDF

Sediment Transport Characteristics in a Pressure Pipeline (압력 원형관로내 유사이송특성 연구)

  • Son, Kwang Ik;Kim, Hyun Jung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3B
    • /
    • pp.205-209
    • /
    • 2011
  • The low carrying capacity caused by the deposition in a sewer line is one of the main reason of the urban flood. Therefore, an efficient maintenance and management of the storm water drainage system is very important to prevent urban flood. In this research, the sediment transport characteristics through a pressure pipeline were examined with laboratory experiments. Bed-forms in a pipeline, sediment rates, roughness due to sediments were examined. Experimental system consists of flow circulation system with a pump and a sediment feeder at the upstream of the pipeline. Sediments were supplied into a 60 mm-diameter and 8 m-long pipe. Maximum flow rate is $30m^3/hr$, and the sediment feeding rate range is 5 g/s~19 g/s. Governing parameters and estimation equation for sediment transport rate were developed. The mean velocity (U), coefficient of viscosity (${\mu}$), unit width bed load ($q_b$), mean diameter of particle ($d_{50}$), unit weight of sediment in water (${\gamma}^{\prime}_s$) were adopted as the most influencing factors of sediment transport patterns. The prediction equation for sediment transport rate were developed with two dimensionless terms. These two dimensionless terms showed a linear relationship with high correlation coefficient.

Analysis of Channel Habitat Characteristics for Soundness of Fish Community at Wonju-stream (원주천의 어류군집 건전화를 위한 하도의 서식구조 특성분석)

  • Choi, Heung Sik;Choi, Jun Kil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.3B
    • /
    • pp.311-317
    • /
    • 2009
  • Similarity indices between sampling sites are calculated and cluster analysis of fish community is carried out by UPGMA based on investigating fish fauna and water environment. The restoration indicators as target species of Wonju stream are selected Cottus poecilopus, Zacco temmincki, and Zacco platypus along upper, middle, and lower streams, respectively. For better habitat suitability, low flow increasing and induced water quality improving must be secured by sewer system rearrangement and watershed management. Composite habitat suitability of Zacco temmincki as target species at middle stream of Wonju stream improve significantly by low flow increasing, which is very important factor to improve habitat suitability. The changes of hydraulics of depth and velocity govern the habitat suitability in general, but the effects are not significant. Low flow increasing with the change of 10% reducing of lower channel improves the composite habitat suitability of 0.37~0.78 to their origin of 0.1~0.25, which represent the channel restoration scheme of Wonju stream for enhancing the habitat suitability of fish community.