• Title/Summary/Keyword: sewage wastewater treatment

Search Result 436, Processing Time 0.026 seconds

Analysis of RCSTP Sewage Characteristics and Treatment Efficiency in Rural Area (농촌 지역 마을하수도 유입 하수 특성과 효율 분석)

  • Im, Jiyeol;Jung, Donggi;Gil, Kyungik
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.851-858
    • /
    • 2012
  • This study conducted a result analysis on operation of 26 Rural Community Sewage Treatment Plant (RCSTP) newly constructed in Yeong-yang, Bong-hwa and An-dong areas which are located at the upper region of An-dong Dam and Im-ha Dam. Based on operation result, an analysis on characteristics of sewage in each area and the treatment efficiency of the installed treatment process was conducted. The result of analysis on characteristics of sewage has shown the difference in concentration of the sewage according to area characteristics. Sewage in areas with frequent occurrence of agricultural water and livestock wastewater had high concentration. It is important to select the most suitable treatment process when selecting a treatment process for RCSTP according to properties of sewage in each area. As a result of operation, the disposal efficiency for organic matter and suspended solids was stable with less fluctuation, but the disposal efficiency for nitrogen and phosphorus showed high fluctuation. This signifies that it is necessary to pay attention to operation condition management of nitrogen and phosphorus when operating RCSTP.

The Case Studies of Artificial Intelligence Technology for apply at The Sewage Treatment Plant (국내 하수처리시설에 인공지능기술 적용을 위한 사례 연구)

  • Kim, Taewoo;Lee, Hosik
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.4
    • /
    • pp.370-378
    • /
    • 2019
  • In the recent years, various studies have presented stable and economic methods for increased regulations and compliance in sewage treatment plants. In some sewage treatment plants, the effluent concentration exceeded the regulations, or the effluent concentration was manipulated. This indicates that the process is currently inefficient to operate and control sewage treatment plants. The operation and control method of sewage treatment plant is mathematically dealing with a physical and chemical mechanism for the anticipated situation during operation. In addition, there are some limitations, such as situations that are different from the actual sewage treatment plant. Therefore, it is necessary to find a more stable and economical way to enhance the operational and control method. AI (Artificial Intelligence) technology is selected among various methods. There are very few cases of applying and utilizing AI technology in domestic sewage treatment plants. In addition, it failed to define specific definitions of applying AI technologies. The purpose of this study is to present the application of AI technology to domestic sewage treatment plants by comparing and analyzing various cases. This study presented the AI technology algorithm system, verification method, data collection, energy and operating costs as methods of applying AI technology.

A Study on the Pretreatment Process for Sewage Reuse by Microfiltration Process (정밀여과에 의한 하수고도처리수의 재이용을 위한 전처리법에 관한 연구)

  • Kuk, Young-Long;Joo, Jae-Young;Bae, Yoon-Sun;Lee, Hye-In;Jung, In-Ho;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.5
    • /
    • pp.595-601
    • /
    • 2010
  • It is evident that Korea will continue its battle with water shortage and alternative program are being taken into action. One of the main actions is reusing 1,800 tons of effluent of 357 sewage treatment plant located nationwide. Therefore this study supplemented ozone oxidation methods that would increase the efficiency of organic oxidation and coagulation. Through this method, fouling will be controled sufficiently by preventing membrane process in the system for advanced sewage treatment. In this study, ozone-coagulation-microfiltration membrane were used. The final removal efficiency of the pretreated water from the result of the ozone-coagulation were 50% of CODcr, 38% of TP and 11% of TOC respectively. Water quality treatment has decreased about 80% for TP. Ozone-coagulation-microfiltration membrane maintains the high flux while decreasing the number of organic matter and the membrane fouling, and reducing the TP. As a result, in order to reuse the water from the sewage, the ozone-coagulation-microfiltration membrane type must be considered in order to achieve the best efficiency.

The Development and Application of the Performance Indicator for Sewage System Service in Korea (하수도서비스 평가지표 개발 및 적용에 관한 연구)

  • Ahn, Young Mi;Kim, Duk-Jin;Yoon, Hyun Shik;Kim, Young Jo;Yoo, Man Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.453-465
    • /
    • 2007
  • With rapid expansion of the water market and growth of water companies, the recent trends in international water industry show that standardization of service activities concerning management of water and wastewater system (ISO/TC 224, to be issued in the second half year of 2007) is expected to have a large influence on the global water market including liberalization of water service market. In the Draft International Standard(DIS) of ISO/TC224, Performance Indicators(PIs) are suggested to estimate the service activities relating to water and wastewater treatment facilities. PIs have been developed in many countries including some international organization(World Bank, IWA and etc.) for service benchmarking. To evaluate public service level and establish plans to improve service level of wastewater utilities, we developed PIs for 120 items and applied them to 10 sewage utilities in the consideration of their scales, circumstances and conditions. In this study, we verified the applicability of the developed performance indicators(PIs). So, we concluded that PIs developed for the purpose of this study can be a useful tool applicable to objective evaluation of the service level of sewage utilities. Using the evaluation tool of PIs developed, it can also be used as a benchmarking tool in this industry as well as for enhancing the efficiency of operation and management of the sewage system. It will also contribute to the water resource management through determination of investment priorities based on the evaluation results and to raising international competitiveness of the domestic sewage utilities to meet the future opening of the water market.

Comparison of Sewage Sludge Solubilization through Different Pretreatment Methods (전처리 방법에 따른 하수슬러지 가용화 비교연구)

  • Kwon, Jae-Hyun;Kim, Bong-Jun;Kim, Min-Kyu;Yeom, Ick-Tae;Kim, Hyung-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.17 no.4
    • /
    • pp.567-573
    • /
    • 2003
  • The pretreatment process was carried out to solubilize the sewage sludge for enhancing its biodegradability using alkaline treatment, ultrasonic treatment(15kHz), ozone treatment and different combination of these three methods: alkaline followed by ultrasonic as well as ozone, and ultrasonic followed by alkaline. The solubilization efficiency was evaluated based on the SCOD/TCOD ratio and VSS/TS ratio. In results, the proper condition of alkaline treatment was shown as 30meq/l of NaOH, pH 12 and 3hours of reaction time. Solubilization efficiency increased to 17% from initial 2% based on SCOD/TCOD ratio under this condition. In ultrasonic treatment, the higher ultrasonic power, the longer treatment time and the lower sludge volume resulted in higher solubilization respectively. There was a rapid increase in solubilization efficiency after 20 minute, then it was measured as 32% of SCOD/TCOD ratio in 1 hour at a ultrasonic power of 1,300W with 1/sludge. Solubilization efficiencies in combined treatment using alkaline and ultrasonic were 47-53% higher than single treatment at a sonicated time of 1 hour. Ozone treatment followed by alkaline treatment also represented the enhanced solubilization compared to ozone treatment. Therefore, ultrasonic or ozone treatment assisted by alkaline could achieve the short treatment time as well as high solubilizetion efficiency.

A Study on the Effect of Chemical Pretreatment for Livestock Wastewater on the Linked Treatment of Sewage (축산폐수 처리 시 화학적 전처리가 연계처리에 미치는 영향 연구)

  • Han, Jun-Suk;Han, Gee-Bong
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.18 no.1
    • /
    • pp.89-97
    • /
    • 2010
  • In this study, to investigate the effect of chemical pretreatment for livestock wastewater, laboratory scale test for ozonation and linked treatment of sewage were conducted. and the results were obtained as follows. The ozonation of livestock wastewater showed the COD removal rate per hour to be 17%, 78% and 62% at each pH 4, 7 and 10, respectively. With transformation of NBDCOD to biodegradable BDCOD by ozonation, the ratio of SCODcr/TCODcr was increased from 26% to 38%. Accordingly, pretreatment of livestock wastewater affected to the biological post treatment process to elevate removal efficiency by transformation of nonbiodegradable mass to biodegradable mass. As the results of linked treatment of pre-ozonated livestock wastewater and sewage in the MLE process, the treatment efficiencies of TCODcr 93.8%, T-N 74.3%, T-P 89.7%, SS 97.5% were earned at 100% of internal recycle rate. When the internal recycle rate was increased to 150%, the treatment efficiencies of TCODcr 94.5%, T-N 54.5%, T-P 70.8%, SS 98.5% were earned. Also the removal efficiencies of TCODcr 92.6%, T-N 83.1%, T-P 81.9%, SS 98.5% were earned as the internal recycle rate was increased to 200%. Especially, nitrogen removal efficiency in the linked treatment showed 74.3%, 54.5%, 83.1% at 100%, 150% and 200% of internal recycle ratio, respectively, which revealed the tendency of higher removal efficiency than that of sewage treatment.

Advanced Treatment of Shipboard Sewage by RCM Process with BM (복합미생물제제를 이용한 RCM공법의 선박오수 처리장치 적용에 관한 연구)

  • Ha, Shin-Young;Kim, In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.38 no.5
    • /
    • pp.451-456
    • /
    • 2014
  • Lab scale experiment was carried out to study biological wastewater treatment technology developed for shipboard. RCM process using BM(Beneficial Microorganisms) was investigated for practical application on shipboard sewage treatment. RCM process is an environmental friendly treatment system, with minimum production of sludge. In the test, BOD5, CODcr, T-N and T-P were reduced a 96%, 97%, 78% and 81.68% respectively. From the result it was suggested that RCM process with BM might be a suitable process for shipboard sewage treatment, maintenance of useful microorganisms and creating special environment as the SDC tank is circulating in the non-biodegradable organics sludge generated during the wastewater treatment, thus reducing the amount of sludge generated. Therefore, the RCM process does not require additional equipment to strengthen it to meet the marine pollution standards.

Characteristics of TOC in effluent discharge from public sewage treatment works in korea (우리나라 공공하수처리시설의 TOC 배출특성 및 관리방안 연구)

  • Jeong, Dong-Hwan;Choi, In-Cheol;Cho, Yangseok;Ahn, Kyunghee;Chung, Hyen-Mi;Kwon, Ohsang;Park, Hoowon;Shin, Hyunsang;Hur, Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.6
    • /
    • pp.657-668
    • /
    • 2014
  • Under Korea's Enforcement Decree of the Framework Act on Environmental Policy amended in 2013, total organic carbon (TOC) is newly added as water quality parameter to assess organic pollution in water and aquatic ecosystem. To meet the TOC requirement and improve quality of effluent discharged into public watershed, it is also necessary to develop standards for TOC in effluent from public sewage treatment works (PSTWs). In this study, we reviewed the characteristics and removal efficiency of TOC in influent and effluent of PSTWs. The study found that phosphorus treatment process removed not only soluble phosphorus but also a portion of TOC remaining after the secondary treatment process. TOC concentration in effluent from PSTWs operated in tandem with industrial wastewater treatment work was higher due to influx of insoluble substances from the industrial wastewater treatment work. In order to lay a foundation for the management of TOC from PSTWs, it is necessary to carry out research on TOC from different perspectives. For example, studies on the generation mechanism of TOC and the impact of TOC on drinking water resources, assessment of effluent qualities through monitoring, and development of measures to control TOC for the preservation of aquatic ecosystem are needed.

Enhancement of Sewage Sludge Dewaterability by H2O2-Oxidation and Mixing with Paper Sludge (하수슬러지 탈수성 개선을 위한 과산화수소 처리 및 제지슬러지 혼합탈수에 관한 연구)

  • Hwang, Sun-Jin;Eom, Hyoung-Choon;Jang, Hyun-Sup;Jang, Kwang-Un;Kwon, Jae-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.508-514
    • /
    • 2004
  • Industrial and municipal wastewater treatment plants produce large amounts of sludge cakes for final disposal. This problem is an inevitable drawback inherent to the activated sludge process. Both the reduction of the amount of sludge produced and improvement of its dewaterability are presently very important issue also in Korea. So many pre-treatment processes have been developed in order to improve sludge dewatering efficiency. In this study the effects of hydrogen peroxide and paper sludge mixing processes were considered as reasonable alternatives to enhance sludge dewaterability. The CST of sludge was significantly decreased, and dewaterability improved by hydrogen peroxide oxidation treatment. The optimum dosage of hydrogen peroxide was proved to be 10mg/g-TS (when TS of sludge was 2%) with the conditions of pH 4 and only 1~2 minutes of reaction time. The mixing of paper sludge with sewage sludge was turned out to be very effective in reduction of sludge cake; 30% of sludge cake reduction was accomplished. Optimum mixing ratio of paper sludge was about 30%(v/v). This process also could save 25% of polymer to be required. These two alternatives are somewhat realistic, but it was concluded that paper sludge mixing process will be the best choice.