• Title/Summary/Keyword: sewage treatment water

Search Result 716, Processing Time 0.024 seconds

The System Improvement of the Individual Sewage Treatment System (개인하수처리시설의 제도개선에 관한 연구)

  • Jang, Hyo-Ju;Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.33-40
    • /
    • 2010
  • Individual sewage treatment system is classified into a sewage treatment system which treats all the domestic sewage and a water-purifier tank which treats only effluent flushing from the toilet. The number of registered manufacturers has increased rapidly since 2001. As a result, price competition has increased among the manufacturers and has caused the problems such as the inappropriate production of individual sewage treatment system, the unreasonable permit for building completion and the shortage of the professional technology of the community's public officials in charge. This study collected the problem cases that are related with existing individual sewage treatment system and operation. Efficient improvement plan for the stable supply, installation, maintenance of individual sewage treatment system were suggested.

Application of Sewage Treatment Processes to a System Design for Water Resource Production 1. Analysis and Assessment of Sewage Treatment Process Efficiency (하수처리공정의 물 자원 생산 시스템 설계에 대한 적용 1. 하수처리공정의 처리효율 분석 및 평가)

  • Shin, Choon Hwan
    • Journal of Environmental Science International
    • /
    • v.25 no.8
    • /
    • pp.1155-1163
    • /
    • 2016
  • The treatment efficiencies of domestic sewage treatment processes were analysed and assessed to suggest and design a suitable technology for coal seam gas (CSG) water treatment. Two sewage treatment plants (S and G in Busan) were selected. The former operates with standard activated sludge and modified Ludzak Ettinger processes while the later uses the combination of $A_2/O$ and gravity fiber filtration. For both plants, the concentrations of BOD, $COD_{Mn}$, T-N and T-P were about 5.0, 19.0, 5.0, 11.0 and 1.0 ppm, respectively, which satisfy the discharge standards. Therefore, although sewage treatment processes seems to be applicable for CSG water treatment, additional processes to remove total dissolved solids and ionic compounds (i.e. bicarbonate) need to be introduced to produce fit-for-purpose water resources for beneficial use (in accordance with Water ACT 2013). This, for the CSG treatment process design, it is necessary to align the operating conditions with merging methods of combinable unit technology obtained from sewage treatment processes.

Water Quality Correlation Analysis between Sewage Treated Water and the Adjacent Downstream Water in Nakdong River Basin (낙동강유역의 하수처리장 방류수와 인접 하류하천의 수질상관관계 분석)

  • Cho, Hyun Kyung;Kim, Sang Min
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.2
    • /
    • pp.202-209
    • /
    • 2018
  • The purpose of this study was to analyze the correlation between the effluent of a sewage treatment plant (STP) and the adjacent stream located downstream of the STP in Nakdong River. Flow and water quality data, such as BOD, COD, SS, T-N, and T-P data, for 12 STPs and adjacent downstream monitoring stations in the main stream and tributaries of Nakdong River were collected from 2012 to 2015. As a result of correlation analysis between river flow and water quality at the river water quality measurement point, COD, SS, and T-P were correlated positively with the river flow rate at 6, 8, and 6 points, respectively. As a result of analyzing the water quality of sewage treatment plant effluents and downstream streams, BOD and COD were correlated at 2 and 3 points, respectively. T-N showed a positive correlation at 9 points, and 7 of them had a strong positive correlation, indicating that sewage treatment effluent had a large effect on downstream streams. In this study, we found that the correlation between the river flow rate and the water quality factors (COD, SS, TP) was high at river water measurement points, and the sewage treatment plant effluent was correlated with the T-N value of adjacent streams.

Water Quality Correlation Analysis between Sewage Treated Water and the Adjacent Downstream Water in Nakdong River Basin (낙동강유역의 하수처리장 방류수와 인접 하류하천의 수질상관관계 분석)

  • Cho, Hyun Kyung;Kim, Sang Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2018.05a
    • /
    • pp.493-493
    • /
    • 2018
  • The purpose of this study was to analyze the correlation between the effluent of the sewage treatment plant (STP) and the adjacent stream located downstream of the STP in Nakdong River. The flow and water quality such as BOD, COD, SS, T-N, and T-P data for 12 STPs and adjacent downstream monitoring stations in the main stream and tributaries of Nakdong River were collected from 2012 to 2015. As a result of correlation analysis between river flow and water quality at the river water quality measurement point, COD, SS and T-P were correlated positively with river flow rate at 6, 8, and 6 points, respectively. As a result of analyzing the water quality of sewage treatment plant effluent and downstream stream, BOD and COD were correlated at 2 and 3 points, respectively. T-N showed a positive correlation at 9 points, and 7 of them had a strong positive correlation, indicating that sewage treatment effluent had a large effect on downstream streams. In this study, we found that the correlation between river flow rate and water quality factors (COD, SS, TP) was high for river water measurement points, and the sewage treatment plant effluent was correlated with the T-N value of adjacent streams.

  • PDF

Alternatives for Optimum Installation of Rural Sewage Treatment Facilities in Chungchongnam-do Province (충청남도 마을하수처리시설의 최적 설치방안)

  • Yi, Sang-Jin;Jung, Jong-Gwan;Lim, Bong-Su;Huh, Jae-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.462-472
    • /
    • 2005
  • This study was carried out to suggest the plans for installation of rural sewage treatment facilities through the analysis of these facilities installed in Chungchongnam-do Province. About 5% of all installation was carried out by the department of wastewater and related environment problems and the other case was carried out by the department of construction or residence. In wastewater caused by 250 and 300 persons, facilities capacity do not exceed about $50m^3/d$, caused by 2,500 and 3,000 persons, $500m^3/d$. Advanced sewage treatment process were first needed in the discharge area where affected the water environment greatly. However, in carrying out the water quality pollutant of the total amount management system in the other areas, they should be driven only over the scale of pollutant quota object facilities standard. Rural sewage must be included in the special accounts according to the regulations of local government, and sewage treatment cost should be collected to manage. Installation type uses integrating joint treatment method in case the distance among villages is short or one treatment facility independently.

Analysis of RCSTP Sewage Characteristics and Treatment Efficiency in Rural Area (농촌 지역 마을하수도 유입 하수 특성과 효율 분석)

  • Im, Jiyeol;Jung, Donggi;Gil, Kyungik
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.6
    • /
    • pp.851-858
    • /
    • 2012
  • This study conducted a result analysis on operation of 26 Rural Community Sewage Treatment Plant (RCSTP) newly constructed in Yeong-yang, Bong-hwa and An-dong areas which are located at the upper region of An-dong Dam and Im-ha Dam. Based on operation result, an analysis on characteristics of sewage in each area and the treatment efficiency of the installed treatment process was conducted. The result of analysis on characteristics of sewage has shown the difference in concentration of the sewage according to area characteristics. Sewage in areas with frequent occurrence of agricultural water and livestock wastewater had high concentration. It is important to select the most suitable treatment process when selecting a treatment process for RCSTP according to properties of sewage in each area. As a result of operation, the disposal efficiency for organic matter and suspended solids was stable with less fluctuation, but the disposal efficiency for nitrogen and phosphorus showed high fluctuation. This signifies that it is necessary to pay attention to operation condition management of nitrogen and phosphorus when operating RCSTP.

An Application of the NPR Process for the Treatability Improvement of an Existing Sewage Treatment Plant (기존 하수처리장 성능개선을 위한 NPR공정의 적용)

  • Moon, Tae Hoon;Ko, Kwang Baik;Song, Eui Yeol
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.756-760
    • /
    • 2007
  • Most of the sewage treatment plants in Korea are being operated by using the conventional activated sludge process. Recently, as the water criteria have been strict with regard to such main culprits of eutrophication, the existing sewage treatment plants are obliged to upgrade their treatment technology to meet the criteria. Under such circumstances, this study was aimed at analyzing the conditions of an existing sewage treatment plants in Korea, and thereupon, test its treatment performance for the actual sewage water by operating a pilot plant. When the pilot plant was operated with the NPR process at the capacity of $30m^3/day$, the average contents of BOD, $COD_{Mn}$, SS, T-N and T-P in the effluents were 7.0 mg/L, 9.7 mg/L, 5.1 mg/L, 8.0 mg/L and 0.23 mg/L, respectively, which were very stable in general. Accordingly, if the NPR process used for this pilot plant to upgrade the treatment technology for the sewage treatment plat could be adopted, the effluent water quality criteria effective beginning from 2008 would be met.

The Assessment on the Effect of Discharge and Variation of Water Quality from the Sewage Treatment Plants in Seoul (서울시 하수처리장 수질의 변동 및 방류수의 영향 평가)

  • Kwak Mi-Ae;Jung Jong-Heub;Eo Soo-Mi;Lee Hong-Keun
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.3 s.53
    • /
    • pp.1-12
    • /
    • 2004
  • This study was conducted to evaluate the variation characteristics of influent and effluent quality from sewage treatment facilities using activated sludge processes and to assess the impact caused by discharge of treated sewage on the receiving water Monthly data of five water quality items (BOD, COD, SS, T-N, T-P) were used to understand the water quality at three sewage treatment plants in Seoul for five years from 1999 to 2003. Concentration differences of water quality parameters were observed between upstream and downstream site at the sewage treatment plant outfall to investigate the impact of discharge in Tan stream and Han river basin. 1. Due to the effect of continuous improvement in sewer system, the concentrations of influent went on increasing generally. 2. Effluent concentrations of BOD, COD and SS showed the trend of a little decreasing, but the trend of increasing in T-N and T-P. 3. In Tan stream basin, the impact of sewage treatment plant discharge was not observed directly, because concentration of discharge was lower than stream water's. But discharges from sewage treatment plants affected water quality at downstream site in Han river, concentration of T-P especially.

Optimization of Operating Conditions for Each Linked Treatment Scenario using Sewage Treatment Modeling (하수처리 모델링을 이용한 연계처리 시나리오별 운전조건 최적화)

  • Kim, Sungji;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.23 no.1
    • /
    • pp.7-13
    • /
    • 2021
  • Due to rapid industrial development, population growth, and improvement of living standards, the amount of sewage and wastewater, including nutrients, is increasing every year. In addition to the increasing amount of sewage and wastewater generation, untreated linked treated water (manure, livestock manure, industrial wastewater, leachate, food waste) is also increasing, and many of the linked treated water flows directly into nearby sewage treatment plants. The associated treated water causes many problems because of its own characteristics, low flow rate with high concentration compared to existing inflow sewage. In order to solve this problem, it is necessary to investigate the quantity and quality of the connected treated water whichh is flowed into the sewage treatment plant, and a study the effect on sewage treatment. Therefore, in this paper, we would like to examine the effect of the linked treated water. Seasonal effect associated with water pollution conditions was considered. In addition, a scenario was created through the distribution and inflow of connected treated water along with the water temperature conditions. Through scenario analysis, we intend to optimize the operating conditions of linked processing.

Application of the Proper Air Supply Amount Based on the Influent Water Quality for the Development of Efficient Blower Control Logic in Sewage Treatment Plants (하수처리장의 효율적인 Blower Control Logic 개발을 위한 유입수질 기반 공기공급량 적용 연구)

  • Yeo, Wooseok;Kim, Jong Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.4
    • /
    • pp.493-499
    • /
    • 2022
  • The standards pertaining to the quality of discharged water in sewage treatment plants are strengthening, and accordingly, facilities in sewage treatment plants are being upgraded. In addition, the discharge water quality of sewage treatment plants must be maintained at a high level, and efficient sewage treatment plant operations have thus emerged as a very important issue. For the efficient operation of sewage treatment plants, this study applied a basic blowing amount calculation method based on sewage facilities to evaluate the required oxygen amount and blowing amount according to inflow water quality by logicizing various influencing factors. As a result of calculating the amount of air blown by applying actual April water quality data from sewage treatment plant A to the blower demand calculation developed through this study, it was found that the average amount of air blown was reduced by about 12%. When the blower demand calculation developed here is applied to an actual sewage treatment plant, the amount of air blown can be controlled based on the inflow water quality. This can facilitate the realization of an autonomous control of sewage treatment plants, in contrast to the existing sewage treatment operation method that relies on operational experience of operator. In addition, it is expected that efficient sewage treatment plants can be operated by reducing blowing amounts and power costs, which will contribute to both energy and carbon savings.