• Title/Summary/Keyword: several types of load

Search Result 176, Processing Time 0.028 seconds

Analysis of Crosshead-pin Bearing with Various Oil Groove Shape for Marine Engine (박용엔진용 크로스헤드 핀 베어링의 급유 형사에 따른 윤활특성 해석)

  • 하양협;이득우;김창희;김정훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.578-583
    • /
    • 1997
  • Abstract-Crosshead bearing in two-stroke marine diesel engine is operated under quite severe condition since the load on the bearing is sybject to the loading in a unidirectional and the sliding speed is very slow and oscillatory. So it is very difficult to form oil film and maintain the load. In this paper, two types of bearing are compared. One has large sized oil pocket and the seleted as multi-small oil grooves. Bearing clearance, oil inlet oressure and bearing types are selected as analysis parameters. Loci of journal center are presented to compare several cases. It is found that bearing clearance and shape affect to minimum film thickness.

  • PDF

Analysis of Life Cycle Cost for Heat Source Equipments in Buildings for Adolescent Trainees (청소년 수련관의 열원설비 대안별 생애주기 비용에 관한 연구)

  • Ahn, Chang-hwan;Pang, Seung-ki;Baik, Yong-gyu
    • KIEAE Journal
    • /
    • v.5 no.3
    • /
    • pp.25-31
    • /
    • 2005
  • Computer simulations were performed for Heating Ventilating and Air-Conditioning (HVAC) systems to figure out more efficient maintenance methods for the building used for adolescent trainees. This study aims at suggesting design alternatives for optimum operation and performing life cycle cost (LCC) for each alternative. First, the capacity of the heat source equipment was determined using annual maximum heating and cooling loads. Annual loads were calculated and applied to the alternative for the purpose of calculating annual energy cost. Second, several types of data were collected to predict energy cost. Finally, the pay back period for each alternative was calculated using total cost estimation during standard duration period. This study indicates that the absorption chiller that does not occupy most part of a mechanical room, and does not need much operation cost was most economical.

Comparison analysis of physiological work capacity for different tasks (작업유형에 따른 생리학적 작업능력의 비교 분석)

  • 박지수;김홍기;최진영
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.89-98
    • /
    • 1996
  • The objective of this study was to make comparison of the physical work capacities with different types and methods of tasks. To produce standard work loads, a bicycle ergometer and a treadmill were used for the purpose of two different types of tasks. Maximal oxygen uptake measurement tests are usually performen (1) continuously - with no rest between work load increments, or (2) discontinuously - with the subjects resting several minutes between work periods. Continuous test protocol with two different methods of work load increments, (1) ramp test- with 3 to 5 minutes of work period for each work load, and (2) incremental test - where exercise intensity was increased progressively in 2 minutes interval, were used. Predicted physicala work capacities (PWCs) were compared with the one by Kim(1990), and Lee(1995), and the NIOSH physiological criteria. For ergometer test, the PWC based on the ramp test was 89.65% of the one based on the incremental test. The PWC values were 2553.88 ml/min for the ramp test and 2848.82 ml/min for the incremental test. For treadmill test, the PWC based on the ramp test was 97.54% of the one based on the incremental test. The PWC values were 2786.89 ml/min for the ramp test and 2857.24 ml/min for the incremental test. The PWC obtained with a bicycle ergometer was 91.64% of the one obtained with a treadmill for the ramp test, and 99.71% for the incremental test.

  • PDF

The Simulation Approach for the Optimal Design of Small Scale District Heating and Cooling System (소규모 지역냉난방 시스템 최적설계 시뮬레이션)

  • Im, Yong-Hoon;Park, Hwa-Choon;Cho, Soo;Jang, Cheol-Yong;Chung, Mo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.147-154
    • /
    • 2008
  • A simulation program is developed for the optimal design of small scale district heating and cooling system. Main features for the simulation program are the reliability and the easiness for the optimal design of the DHC(District Heating and Cooling) systems. In order for implementing those features, the operational characteristics according to the prime movers is modeled based on the materials of efficiency as a function of operational load. The unit energy load model is also developed extensively for several building types, of which the corresponding district consist, such as apartment complex, hotel, hospital, buildings for business and commercial use respectively. The specific features and the overall procedure of the simulation are described in brief in this paper. The results of the simulation for several test cases will be presented in subsequent study.

  • PDF

Power Loss Analysis of Transformer Caused By Current Harmonics (전류 고조파에 기인하는 변압기 손실 해석)

  • Jang, Seungyong;Han, Sanghoon;Choi, Jaeho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.1
    • /
    • pp.34-41
    • /
    • 2016
  • This study investigates transformer losses caused by current harmonics. Electrical transformers are designed to work under sinusoidal voltage and current waves at a rated frequency. Recently, various nonlinear loads, such as power electronic converters, are connected to a power system; these converters generate current harmonics. Current harmonics increase power loss in transformers, which results in several problems, including temperature increase of the transformer and insulation damage. These problems will eventually shorten the operational life of the transformer. In this study, different types of losses caused by current harmonics in three-phase transformers are studied under linear and nonlinear load conditions. Linear loads are simulated and experimented on using pure resistance load, whereas nonlinear loads are simulated and experimented on using a three-phase twelve-pulse thyristor full-bridge rectifier. The different types of losses in three-phase transformers are evaluated analytically through the experimental result and simulation in PSiM.

Optimal Arrangement of Resilient Mount installed on Frame Support Structure at Shipboard Equipment under Shock Load (충격하중하의 탑재장비 프레임 지지구조의 탄성마운트 배치 최적화에 관한 연구)

  • Ji, Yong Jin;Kwak, Jeong Seok;Lee, Hyun Yup;Kim, Sung Chan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.4
    • /
    • pp.298-304
    • /
    • 2015
  • Shipboard equipment in naval ships should be designed to be safe under the shock load. Very high stress due to the shock load can be effectively reduced by the resilient mounts considering the mount capacity and dynamic characteristics. An optimum arrangement of resilient mount installed to absorb the shock energy is addressed to assess the safety of ship structure and shipboard equipment subjected to the shock load. Structural responses are analyzed for both frame structure supporting the shipboard equipment subject to the shock load with and without the resilient mounts. The shock absorbability of the resilient mount is evaluated by the results of structural response analysis; meanwhile, several types of shock analyses considering the arrangement of resilient mounts are carried out and the shock responses are compared to verify the effect of the arrangement. Thereafter, optimum arrangements are obtained by means of Genetic algorithm (GA) considering the different capacities of resilient mount. Stress, deformation and dynamic feature at the frame structure supporting the shipboard equipment under the shock load are also discussed in order to meet the capacity of resilient mount.

An Analysis of Heating and Cooling Energy Cost according to Building Type of Apartment Complex (공동주택 단지의 주동형식에 따른 냉난방 에너지 비용 분석)

  • Roh, Ji-Woon
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.96-105
    • /
    • 2013
  • This study aims to investigate the energy performance of apartment in respect of complex design, building type and generation house layout and finally to produce the guide line for energy saving design. To grasp the present condition and problem about this subject, apartment building types were examined and representative types were extracted. Considering azimuth angle, private area, and generation number, building type of the subject apartment was classified in detail, energy simulation was conducted, and the effect to energy cost was compared. In the research, using VE energy simulation program, the heating and cooling load were calculated and converted to energy cost. It is expected that this analysed results will be basic data for the more integrated study. Research consequence can be summarized as follow: 1) Energy cost is compared according to several azimuth in plank '一' type apartment. As the results, calculated gas cost is the best in $49^{\circ}$, but total cost is in $-31^{\circ}$. 2) Apartment buildings of tower types are compared, it is resulted that 'Y' type (azimuth $-7^{\circ}$, $-20^{\circ}$) is the best in gas cost, but the total cost is worst because of high cooling load.

The Effects of Supportive Information Types in Web-Based Learning Using 4C/ID Model (4C/ID 모형을 적용한 웹기반 학습에서 지원정보 유형에 따른 효과)

  • Kim, Kyung;Kim, Kyung-Jin
    • Journal of The Korean Association of Information Education
    • /
    • v.20 no.6
    • /
    • pp.655-672
    • /
    • 2016
  • The purpose of this study was to investigate the effects of prior-knowledge level and supportive information types in web-based learning using 4C/ID model(Four-Components Instructional Design model) on cognitive load and schema acquisition. To achieve the purpose, this study applied a web based learning. 166 university students participated in web-based learning for 4 weeks. After web-based learning, they checked self report for cognitive load and made concept map for schema acquisition and the datum from them were used for 2 ways ANOVA. According to the findings, groups in prior-knowledge level invested significantly differences on cognitive load and a question group in case of supportive information types didn't invested significant differences on cognitive load with statement group. Second, groups in prior-knowledge level invested significantly differences on schema acquisition and a question group in case of supportive information types invested significantly higher schema acquisition than a statement group. Furthermore, it happened interaction effect between supportive information types and prior-knowledge level on schema acquisition. This research has several implications with regard to suggesting the guidelines and conditions for the authentic task of the novice.

A Study on the Strength of Metal-Composite Hybrid Joints (금속-복합재 하이브리드 체결부의 강도 특성 연구)

  • Jung, Jae-Woo;Song, Min-Hwan;Kweon, Jin-Hwe;Choi, Jin-Ho
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.04a
    • /
    • pp.94-97
    • /
    • 2005
  • The strength of aluminum 7075 and carbon composite hybrid joints was studied for adhesive, bolt, and the adhesive-bolt combined joints. Several hybrid joint specimens were tested to get the failure load and modes for three types of the joints. Adhesive Cytec EA9394S was used for aluminum and carbon bonding. Failure load of the adhesive-bolt combined joint was 94 % of the sum of the failure load of the separately bonded and bolted joints. Hybrid joint also showed more stable failure behavior than the simple adhesive or bolted joint.

  • PDF

Coupled effect of variable Winkler-Pasternak foundations on bending behavior of FG plates exposed to several types of loading

  • Himeur, Nabil;Mamen, Belgacem;Benguediab, Soumia;Bouhadra, Abdelhakim;Menasria, Abderrahmane;Bouchouicha, Benattou;Bourada, Fouad;Benguediab, Mohamed;Tounsi, Abdelouahed
    • Steel and Composite Structures
    • /
    • v.44 no.3
    • /
    • pp.353-369
    • /
    • 2022
  • This study attempts to shed light on the coupled impact of types of loading, thickness stretching, and types of variation of Winkler-Pasternak foundations on the flexural behavior of simply- supported FG plates according to the new quasi-3D high order shear deformation theory, including integral terms. A new function sheep is used in the present work. In particular, both Winkler and Pasternak layers are non-uniform and vary along the plate length direction. In addition, the interaction between the loading type and the variation of Winkler-Pasternak foundation parameters is considered and involved in the governing equilibrium equations. Using the virtual displacement principle and Navier's solution technique, the numerical results of non-dimensional stresses and displacements are computed. Finally, the non-dimensional formulas' results are validated with the existing literature, and excellent agreement is detected between the results. More importantly, several complementary parametric studies with the effect of various geometric and material factors are examined. The present analytical model is suitable for investigating the bending of simply-supported FGM plates for special technical engineering applications.