• Title/Summary/Keyword: settling test

검색결과 130건 처리시간 0.03초

회전부를 장착한 터빈 시험장비 개발 (Development of a Rotating Turbine Test Rig)

  • 박응식;송성진;홍용식
    • 한국유체기계학회 논문집
    • /
    • 제1권1호
    • /
    • pp.58-63
    • /
    • 1998
  • To investigate turbine flow fields under realistic conditions, a rotating turbine test facility has been developed at the Inha University Propulsion Laboratory. The experimental facility consists of an air inlet, settling chamber, single turbine stage test section, and diffuser. This turbine has a design flow coefficient of 0.55 and work coefficient of 1.88. The turbine test rig has four features. First, a large scale test section improves space resolution. Second, low speed rpm enhances safety and reduces required power, Third, DC motor/generator is able to regenerate blower power. Fourth, various types of experiment can be carried out.

  • PDF

경량 기포 콘크리트의 레올로지 특성이 소포억제에 미치는 영향 (Influence of Rheological Properties of Lightweight Foamed Concrete on Preventing Foam Collapse)

  • 이향선;전종운;조무진;기성훈;한동엽
    • 한국건설순환자원학회논문집
    • /
    • 제6권4호
    • /
    • pp.304-310
    • /
    • 2018
  • 본 연구에서는 경량 기포 콘크리트의 부피 안정성을 확보하기 위해 소포를 저감시킬 수 있는 요소들을 레올로지 특성을 연계하여 분석하였다. 실험계획으로는 비빔시간, 물-결합재비, 증점제, 기포제, 폐지 첨가량에 대한 변화로 각 요인을 통해 실험하였다. 먼저 과도한 비빔과 기포제의 첨가량에 의해 발생한 다량은 기포는 슬러리 내에서 불안정한 상태로 존재하여 침하를 발생시킨다. 특히 기포제의 경우 계면활성제로써 물에 영향을 미치므로 배합 계획 시 물에 대한 질량비로 계획해야할 것으로 판단된다. 또한 레올로지 특성을 통해 경량 기포 콘크리트의 소성점도와 소포량이 반비례관계를 가진 것을 확인할 수 있었다. 따라서 본 연구의 결과는 경량 기포 콘크리트의 소포를 저감시킬 수 있는 요소들을 분석함으로써 경량 기포 콘크리트의 배합 조건에 대한 기초적인 자료를 제공될 것으로 판단된다.

데이터 주도 접근법을 활용한 소프트웨어 테스트 자동화 : 온라인 쇼핑몰 결제시스템 사례 (Software Test Automation Using Data-Driven Approach : A Case Study on the Payment System for Online Shopping)

  • 김성용;민대환;임성택
    • 한국IT서비스학회지
    • /
    • 제17권1호
    • /
    • pp.155-170
    • /
    • 2018
  • This study examines a data-driven approach for software test automation at an online shopping site. Online shopping sites typically change prices dynamically, offer various discounts or coupons, and provide diverse delivery and payment options such as electronic fund transfer, credit cards, mobile payments (KakaoPay, NaverPay, SyrupPay, ApplePay, SamsungPay, etc.) and so on. As a result, they have to test numerous combinations of possible customer choices continuously and repetitively. The total number of test cases is almost 584 billion. This requires somehow automation of tests in settling payments. However, the record playback approach has difficulties in maintaining automation scripts due to frequent changes and complicated component identification. In contrast, the data-driven approach minimizes changes in scripts and component identification. This study shows that the data-driven approach to test automation is more effective than the traditional record playback method. In 2014 before the test automation, the monthly average defects were 5.6 during the test and 12.5 during operation. In 2015 after the test automation, the monthly average defects were 9.4 during the test and 2.8 during operation. The comparison of live defects and detected errors during the test shows statistically significant differences before and after introducing the test automation using the data-driven approach.

Experimental study on vacuum preloading with flocculation for solid-liquid separation in waste slurry

  • Wu, Yajun;Kong, Gangqiang;Lu, Yitian;Sun, De'an
    • Geomechanics and Engineering
    • /
    • 제13권2호
    • /
    • pp.319-331
    • /
    • 2017
  • This vacuum preloading combined with polyacrylamide (PAM) flocculation was proposed to separating solid-liquid in waste slurry and to improving bearing capacity of soft soil ground. By using waste slurry taken from drilled shaft construction site in Shanghai, China, a series of settling column tests with four typical flocculants and one normal for waste slurry were carried out for comparative analysis. The optimal amounts for each flocculant were obtained from the column tests. Then, model tests on vacuum preloading with anionic polyacrylamide (APAM) flocculation and without flocculants were carried out. The out of water and the settlement of slurry surface ground were monitored during the model tests, and the changes in water content, particle-size and pore-size distributions in different positions after the model tests were measured and discussed. It is found that water content of the waste slurry without APAM flocculation changed from 204 to 195% by 24 hours standing and 15 hours vacuum preloading, while the water content of the waste slurry with APAM flocculation was declined from 163 to 96% by 24 hours standing, and was further reduced into 37% by 136 hours vacuum preloading, which shows that the combined method is feasible and effective.

SHARON/ANAMMOX 결합공정에서 슬러지의 입상화와 특성 (Granulation and Characteristics of Sludges in the Combined SHARON/ANAMMOX Processes)

  • 황인수;민경석
    • 한국물환경학회지
    • /
    • 제22권2호
    • /
    • pp.300-307
    • /
    • 2006
  • The combined SHARON (Single reactor system for High ammonium Removal Over Nitrite)-ANAMMOX (Anaerobic ammonium oxidation) reactor were operated in mesophilic condition ($35^{\circ}C$). In this study, microbial granulation and characteristics of SHARON and ANAMMOX sludges were investigated using settling test, Scanning Electron Microscopy (SEM) and Fluorescence In Situ Hybridization (FISH). In SHARON reactor, Aerobic granulation with diameter of 1.5~2.5 mm was accomplished but aerobic granulation was weaker than anaerobic granular sludge. Initial seed sludge of ANAMMOX reactor was used as attached media for biofilm growth. ANAMMOX sludge was more compact and rounder rather than seed sludge. Though ANAMMOX sludge has high activity, it has lower settling ability than the seed granule. The color of ANAMMOX sludge was changed from dark to redish brown granular with diameter of 1~2 mm. In FISH of ANAMMOX sludge, high fraction of Candidatus B. stuttgartiensis which paid great role of nitrogen conversion was detected. Also, FISH results reveals that ANAMMOX bacteria inhabit at inner parts near surface, having advantages in utilization of substrates and protection from oxygen inhibition.

고전압 이용한 준설퇴적토 유효성 및 중금속 변화에 관한 연구 (Study of Effectiveness of using higher voltages in analysis of dredged sediments and heavy metal concentration)

  • 권기범;김상근;;유준;정하익
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1446-1451
    • /
    • 2008
  • The clay found in the river or in any waste water treatment plant usually have a very high content of water. A large amount of sediments hinder the navigation in river. In waste water treatment plant, there is requirement of settling the thick sludge. These problems are overcome by using rapid means of sedimentation and settling. This paper focus on how method of Electrokinetic sedimentation can be made faster. Sedimentation using Electrokinetic phenomenon has been discussed with varied voltage applied and effect and dose of coagulant in increasing the process. The experimental test has been carried out at water content that are generally present in the case of river and small canals carrying waste water. This paper also focus on different heavy metals concentration during the process and the power aspects of process. A series of experiment were done to support the proposed theory and how a bubble formation could hinder the purpose of experiment.

  • PDF

뇌임펄스전압파형의 개선에 관한 실험적 고찰 (A experimental study on the improvement of lightning impulse voltage waveforms)

  • 이정기;김민규;정주영;김익수;최익순;문인욱;강영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1854-1856
    • /
    • 2004
  • In this paper, there have been brief review about the important consideration in laboratory planning and designing 4.2MV impulse voltage generator(IVG), which enable to test and evaluate the UHV dielectric performance of power electric apparatus up to 765kV-class. To improve and reinforce the test ability of the IVG and itself against test object being tested by KERI hereafter, wide investigation and an analysis for a solution, especially overshoot compensation method. With the special consideration about those matters in settling down the 4.2MV IVG have been described with the experimental approaching.

  • PDF

전이보 매스콘크리트의 수화열 저감에 관한 Mock-up 실험 (Mock-up Test on the Reduction of Hydration Heat of Mass Concrete for Transfer Girder)

  • 윤섭;황인성;백병훈;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.707-710
    • /
    • 2004
  • This paper reported the results of mock-up test on mass concrete for transfer girder using setting time difference of super retarding agent(SRA). According to test results, two mock-up structures were made. Plain concrete without placing layer reached maximum temperature after 24hours since placement and caused surface hydration cracks at top section. However, concrete with placing layer reached maximum temperature after 72hours and surface temperature was higher than center temperature, which did not cause surface crack. After form removing, no crack was observed at side surface of plain concrete, while concrete using SRA at mid section had surface scaling and settling crack. According to coring results, concrete with placing layer had a penetration crack from top section to bottom section. Therefore, the setting time difference method to reduce hydration heat will have difficulty in applying the mass concrete for transfer girder.

  • PDF

풍력터빈 성능시험을 위한 풍동 개념연구 (Conceptual Design Study of a Low-Speed Wind Tunnel for Performance Test of Wind Turbine)

  • 강승희;최우람;김해정;김용휘
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.431-434
    • /
    • 2009
  • Conceptual study of an open-circuit type low-speed wind tunnel for test of wind turbine blade is conducted. The tunnel is constituted of a settling chamber, a contraction, closed and open test sections, a diffuser, two corners, a cross leg and a fan and motor. For the performance test, the closed test section width of 1.8 m, height of 1.8 m and length of 5.25 m is selected. The open test section with dimension width of 1.8 m, height of 1.8 m and length of 4.14 m is adopted for aeroacoustic test. The contraction ratio is 9 to 1 and maximum speed in the closed test section is 67 m/sec. Input power in the tunnel is about 238 kW and its energy ratio is 3.6. The wind tunnel designed in present study will be an effective tool in research and development of wind turbine.

  • PDF

침전지의 유동 특성과 Lagrangian Method를 이용한 침전효율 예측에 관한 연구 (A Study on Prediction of Sedimentation Efficiency for Sedimentation Basin using Lagrangian Method)

  • 최종웅;홍성택;김성수;김연권;박노석
    • 대한환경공학회지
    • /
    • 제39권5호
    • /
    • pp.229-236
    • /
    • 2017
  • 국내에서 설치 운영 중인 D정수장의 장방형 침전지를 대상으로 설계유량($15,864m^3/day$)과 운영유량($33,333m^3/day$))에 대하여 CFD 해석 방법을 사용하여 침전지의 유동특성 및 tracer 모의를 수행하였으며, 침전지의 유입부로 유입되는 플럭을 입자로 가정하여 모사하는 Lagrangin 기법을 적용하여 침전지의 효율을 검토하였다. 그 결과 침전지내 흐름을 plug flow 영역으로 만들기 위한 평균 속도값을 0.00193 m/s, 0.00417 m/s로 도출되었다. 또한 각 유량 조건에 대해 Tracer test를 모의한 결과 ${\beta}$(유효접촉인자) 값은 각각 0.51, 0.46, Morrill Index값은 각각 6.05와 3.21, 단락류 Index는 0.54와 0.34로 나타났다.