• Title/Summary/Keyword: set-up verification

Search Result 134, Processing Time 0.185 seconds

The consideration about exact set-up with stereotactic radiosurgery for lung cancer. (폐암 환자의 전신 정위적 방사선 수술시 정확한 SET UP에 대한 고찰)

  • Seo, Dong-Rin;Hong, Dong-Gi;Kwon, Kyung-Tea;Park, Kwang-Ho;Kim, Jung-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.2
    • /
    • pp.1-8
    • /
    • 2004
  • Purpose : What confirm a patient's set-up precisely is an important factor in stereotactic radiosurgery Especially, the tumor is moved by respiration in case of lung cancer. So it is difficult to confirm a exact location by L-gram or EPID. I will verify a exact patient's set-up about this sort of problem by verification system(exactrac 3.0) Materials and Methods : The patient that had lung cancer operated on stereotactic radiosurgery is composed of 6 people. The 5 patients use an ABC tool and 1 patient doesn't use it. I got such a patient's L-gram and EPID image by Body frame(elekta, sweden), compared Ant. image with Lat. one, and then confirmed a set-up. I fused DRR image of CT and X-ray image of Verification system(exactrac 3.0) 3 dimensional, analyzed the coordinate value(vertical, longitudinal, lateral), and then confirmed a difference of existing method. Results : In case of L-gram and EPID, we judge an exact of the patient's set-up subjectively, and on we could treat the patient with radiation. As a result of using Verification system(exactrac 3.0), coordinate value(vertical, longitudinal, lateral) of patient's set-up was comprised within 5mm. We could estimate a difference of the coordinate value visually and objectively. Consequently, Verification system(exactrac 3.0) was useful in judging an exact patient's set-up. Conclusion : In case of Verification system(exactrac 3.0), we can confirm an exact patient's set-up at any time whenever, However, there are several kinds of the demerit. First, it is a complex process of confirmation than the existing process. Second, thickness of CT scan slice is within 3mm. The last, X-ray image has to have shown itself clearly. If we solve this problem. stereotactic radiosurgery will be useful in treating patients why we can confirm an exact patient's positioning easily.

  • PDF

Verification of set-up accuracy using MLC leakage (MLC leakage를 이용할 Verification의 효용성 고찰)

  • Yun InHa;Hong DongGi;Jung WangKwon;Seo DongRin;Yun HwaRyeong;Kim JungMan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.11-19
    • /
    • 2004
  • Purpose : Verification within 5mm is one of the important QA process of IMRP and SRS. Therefore, we improve accuracy of patients set-up using scale point. Materials and Methods : We compare MLC scale pointer with customerized port film graticule for patients who was underwent IMRT and SRS. Results : Scale pointer using MLC showed accurate location of patients landmark including divergency of beam, and any point of patient could be certified by means of cross of MLC. Conclusion : MLC scale pointer is effective and convenient method in verification of patients set-up using L-gram.

  • PDF

Development of an Electronic Simulator for Efficiency Improvement to Verify Electro-Hydraulic Servo Controllers in an Examination Set-up (점검환경에서 유압서보제어기 검증효율을 개선하기 위한 유압식 구동장치 시뮬레이터 개발)

  • Han, Seung Chul
    • Journal of Drive and Control
    • /
    • v.14 no.3
    • /
    • pp.50-57
    • /
    • 2017
  • Recently, methods of verification for electro-hydraulic servo controllers are various and the required number of testing controllers is continuously increasing in some specific systems. In this study, a PCB-based electronic simulator of hydraulic actuators is designed and developed to simplify test set-up for controllers and to facilitate alteration for characteristics of the simulator. Several features to reduce required time and manpower for verifying controllers are described. Especially, the simulator is considerably efficient to examine some controllers for different hydraulic actuators in a test. Response characteristics of the simulator are compared with those of real actuators to demonstrate validity of this method. Results reveal utilizing the designed simulator for inspecting controllers is equally effective as using hydraulic actuators.

Experimental Verification of Set-Up Reference Values for the Determination of Downcoiling Tension in Hot Strip Mill (열간압연시 권취장력 설정기준치의 실험적 검증)

  • 공성락;강용기;김영환;문영훈
    • Transactions of Materials Processing
    • /
    • v.10 no.1
    • /
    • pp.53-58
    • /
    • 2001
  • Set-up reference values, used in determining the optimum downcoiling tension, we experimentally verified in this study. During the actual downcoiling, the strip suffers both tension and bending force through the rotation of mandrel. Therefore, simulative test which can measure both tension and bending resistance of strip was performed to estimate set-up reference value for strip tension during downcoiling operations. The values obtained from the simulative test were correlated with the yield stress which has conventionally been used as reference values for downcoiling tension. The correlative analysis showed that the yield stress of strip can be a good reference value for downcoiling tension. Furthermore, the bending load also shows strong correlation with simulated values due to the close relationship between yield stress and bending load.

  • PDF

Review on Usefulness of EPID (Electronic Portal Imaging Device) (EPID (Electronic Portal Imaging Device)의 유용성에 관한 고찰)

  • Lee, Choong Won;Park, Do Keun;Choi, A Hyun;Ahn, Jong Ho;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.57-67
    • /
    • 2013
  • Purpose: Replacing the film which used to be used for checking the set-up of the patient and dosimetry during radiation therapy, more and more EPID equipped devices are in use at present. Accordingly, this article tried to evaluated the accuracy of the position check-up and the usefulness of dosimetry during the use of an electronic portal imaging device. Materials and Methods: On 50 materials acquired with the search of Korea Society Radiotherapeutic Technology, The Korean Society for Radiation Oncology, and Pubmed using "EPID", "Portal dosimetry", "Portal image", "Dose verification", "Quality control", "Cine mode", "Quality - assurance", and "In vivo dosimetry" as indexes, the usefulness of EPID was analyzed by classifying them as history of EPID and dosimetry, set-up verification and characteristics of EPID. Results: EPID is developed from the first generation of Liquid-filled ionization chamber, through the second generation of Camera-based fluoroscopy, and to the third generation of Amorphous-silicon EPID imaging modes can be divided into EPID mode, Cine mode and Integrated mode. When evaluating absolute dose accuracy of films and EPID, it was found that EPID showed within 1% and EDR2 film showed within 3% errors. It was confirmed that EPID is better in error measurement accuracy than film. When gamma analyzing the dose distribution of the base exposure plane which was calculated from therapy planning system, and planes calculated by EDR2 film and EPID, both film and EPID showed less than 2% of pixels which exceeded 1 at gamma values (r%>1) with in the thresholds such as 3%/3 mm and 2%/2 mm respectively. For the time needed for full course QA in IMRT to compare loads, EDR2 film recorded approximately 110 minutes, and EPID recorded approximately 55 minutes. Conclusion: EPID could easily replace conventional complicated and troublesome film and ionization chamber which used to be used for dosimetry and set-up verification, and it was proved to be very efficient and accurate dosimetry device in quality assurance of IMRT (intensity modulated radiation therapy). As cine mode imaging using EPID allows locating tumors in real-time without additional dose in lung and liver which are mobile according to movements of diaphragm and in rectal cancer patients who have unstable position, it may help to implement the most optimal radiotherapy for patients.

  • PDF

Gemoetrical verification of protein structure for single nucleotide polymorphism (SNP)

  • Uhm, Won-Suhk;Lee, Sung-Geun;Kim, Yang-Seok
    • Proceedings of the Korean Society for Bioinformatics Conference
    • /
    • 2005.09a
    • /
    • pp.256-259
    • /
    • 2005
  • Among non-synonymous SNPs that cause amino acid change in the protein product, the selection of disease-causing SNPs has been of great interest. We present the comparison between the evolutionary (SIFT score) and structural information (binding pocket) to show that the incorporation between them provides an advantage of sorting disease-causing SNPs from normal SNPs. To set up the procedure, we apply the machine learning method to the test data set from the laboratory experiments.

  • PDF

Roll Groover Design and Roll Speed Set-up in Bar Rolling Process Design using Rigid-thermo-viscoplastic FEM (강열점소성 유한요소법을 적용한 봉형상압연 공정설계에서의 공형 설계 및 롤속도 설정)

  • 권혁철;김수영;임용택
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.88-97
    • /
    • 1999
  • In this study, a systematic approach for roll pass design in bar rolling was studied. To minimize the trial and errors in the process design, a roll CAD system and a FE analysis system were combined. Based on the system, a methodology for roll pass design by FEM was studied. At first, designed process was compared with the FE analysis results and process redesign based on the FEM results was performed to obtain the specified final geometry. Then, empirical formula for roll speed set-up was compared with the FE analysis results. Further study on various simulations for bar rolling will help in making up for the inaccuracy in the currently used empirical roll speed rules. In addition, verification of the accuracy of the FE analysis system must be performed using experimental data in the industry.

  • PDF

The Study on Setting up KTX-II's RAM Goals for Requirement Train-set (고속차량(KTX-II) RAM 목표값 설정을 통한 소요량 연구)

  • Cha, Jae-Hwan;Chung, In-Soo;Kim, Jong-Woon;Yu, Yang-Ha
    • Proceedings of the KSR Conference
    • /
    • 2009.05b
    • /
    • pp.191-198
    • /
    • 2009
  • There are almost no studies on verification of requirements for high speed rolling stocks by means of RAM goals and on setting RAM goals by means of verification on practical reliability, availability and maintainability for high speed rolling stocks though they are covered in specification of an order that RAM goals asked of rolling stocks are shown for gaining high quality of them and availability when they are in operation. This study is for estimating number of high speed train-sets that would be supplementarily placed an order through verification of RAM goals of a project for the introduction of KTX-II 100 cars. It verify that optimized requirements for high speed rolling stocks by relatively comparison with between requirements for train-sets through setting RAM goals and requirements for train-sets through analysis of prospects for management balance with high speed rolling stocks.

  • PDF

A Study on the Verification of Dynamic Properities on the basis of Vibration Criteria of Isolation Pad (제진대(Isolation Pad)의 진동허용규제치에 기준한 동특성(動特性) 규명에 관한 연구)

  • 백재호;이홍기;서항석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.869-874
    • /
    • 2001
  • In order that precision equipment using high precision industrial operate normally. vibration criteria of expected area that equipment be set up is micrometer level. that method is a trust design for apply to in field, when there attend to quantifiable method. Hence, semi -empirical method that using on the basis of experimental data about undefined information (properities of vibration source, dynamic properities of structure, etc.,) for prediction of vibration response make the use of dynamic structure design of semiconductor & TFT-LCD in the inside and outside country. Like this, for doing an optimal design of dynamic about structure, it is best important to get trust data that apply to semi-empirical method that is method of prediction vibration level. In this paper, on the basis of experimental data which was offered by a manufacturing company Of precisin equipment that plan to set up in semiconductor factory, we predicted vibration response on expected area that equipment be set up.

  • PDF