• Title/Summary/Keyword: set-up accuracy

Search Result 382, Processing Time 0.028 seconds

A study on the optimal geometrical placement of eLoran stations in Korea (eLoran 송신국 배치 최적화 방안 연구)

  • Lee, Chang-Bok;Shin, Mi-Young;Hwang, Sang-Wook;Lee, Sang-Jeong;Yang, Sung-Hoon
    • Journal of Navigation and Port Research
    • /
    • v.37 no.1
    • /
    • pp.35-40
    • /
    • 2013
  • In the eLoran navigation system, the dominant deterioration factors of navigation accuracy are the TOA measurement errors on user receiver and the GDOP between the receiver and the transmitters. But if the ASF data measured at dLoran reference station are provided for users through the Loran data channel, it will be possible to correct the TOA measurement errors. The position accuracy can be determined by the DOP depending on the geometry of receiver-transmitters, and their optimal placement improves the navigation accuracy. In this study we determined the geometric placement in case of up to six stations, and evaluated the performance of position accuracy for the receiver-transmitter geometry set of eLoran stations. The proposed geometry of eLoran stations can be referred for the construction of eLoran infrastructure meeting the capability of HEA for maritime, and time/frequency users in Korea.

Ultra-Precision Machining of Off-Axis Asymmetric Large-area Reflecting Mirror Using ELID Grinding Process (ELID 연삭을 이용한 비축 비구면 렌즈의 초정밀 가공)

  • Jung, Myung-Won;Shin, Gun-hwi;Kim, Geon-Hee;Ohmori, Hitoshi;Kwak, Tae-Soo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.1
    • /
    • pp.9-15
    • /
    • 2019
  • This study focused on the application of ELID mirror-surface grinding technology to the manufacture of off-axis asymmetric large-area reflecting mirrors made of BK7 glass. The size of the parts, such as asymmetric large-area mirrors or lens, made form-accuracy or roughness especially hard to measure after machining because of the measuring range limit of measurement devices. In this study, the ELID grinding system has been set up for mirror-surface machining experiments manufacturing off-axis asymmetric lenses. A measuring method using a reference workpiece has been suggested to measure the form-accuracy and roughness. According to the experimental results, even when using only a reference workpiece, it is confirmed that the surface roughness was 8 nmRa and form-accuracy was 80 nmRMS, with a best fit asymmetric radius when using a grinding wheel of #8,000. It is found that the accuracy of large-area parts could be estimated by the proposed process.

A Sensitivity Analysis of Accuracy for COMS Outgoing Longwave Radiation Product

  • Kim, Hyunji;Han, Kyung-Soo;Lee, Chang Suk;Shin, Inchul
    • Korean Journal of Remote Sensing
    • /
    • v.31 no.1
    • /
    • pp.39-46
    • /
    • 2015
  • Outgoing Longwave Radiation (OLR) is emitted energy from the Earth that is an important indicator of cooling effect in global scale and meteorological events in regional scale. Satellite-driven OLR products have its advantages overcoming spatially limited representation. The Korean geostationary satellite, Communication, Ocean and Meteorological Satellite (COMS), has been producing OLR product in accordance with its own algorithm since Apr. 2011. This study introduces Spatio-Temporally Equalized Match-up (STEM) approach to evaluate the COMS OLR products. We have tested a number of cases of thresholds set by standard deviations of a subpixel $10.8{\mu}m$ to find optimal representation of OLR in the selective match-up. Each case was then validated with broadband reference data, Clouds and the Earth's Radiant Energy System (CERES). We found that selective STEM approach was useful to validate OLR product especially its distribution in homogeneous grids.

Development of an Advanced Deformable Phantom to Analyze Dose Differences due to Respiratory Motion

  • Shin, Dong-Seok;Kang, Seong-Hee;Kim, Dong-Su;Kim, Tae-Ho;Kim, Kyeong-Hyeon;Koo, Hyun-Jae;Cho, Min-Seok;Ha, Jin-Suk;Yoon, Do-Kun;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.28 no.1
    • /
    • pp.1-10
    • /
    • 2017
  • The difference between three-dimensional (3D) and four-dimensional (4D) dose could be affected by factors such as tumor size and motion. To quantitatively analyze the effects of these factors, a phantom that can independently control each factor is required. The purpose of this study is to develop a deformable lung phantom with the above attributes and evaluate the characteristics. A phantom was designed to simulate diaphragm motion with amplitude in the range 1~7 cm and period up to ${\geq}2s$ of regular breathing. To simulate different tumors sizes, custom molds were created using a 3D printer and filled with liquid silicone. The accuracy of the phantom diaphragm motion was assessed by comparing measured motion with predicted motion. Because the phantom diaphragm motion is not identical to the tumor motion, the correlation between the diaphragm and tumor motions was calculated by a curve fitting method to emulate user-intended tumor motion. Tumors of different sizes were located at same position, and tumor set-up positions were evaluated. The accuracy of phantom diaphragm motion was better than 1 mm. The diaphragm-tumor correlation showed that the tumor motion in the superior-inferior direction increased with increasing diaphragm motion. The tumor motion was larger in the $10cm^3$ tumor than in the $90cm^3$ tumor. The range of difference between the tumor set-up positions was 0 to 0.45 cm. This phantom showed independently adjusting factors such as tumor size and motion to facilitate quantitative analysis of the dosimetric impact of respiratory motion according to these factors.

Comparative Serum Proteomic Analysis of Serum Diagnosis Proteins of Colorectal Cancer Based on Magnetic Bead Separation and MALDI-TOF Mass Spectrometry

  • Deng, Bao-Guo;Yao, Jin-Hua;Liu, Qing-Yin;Feng, Xian-Jun;Liu, Dong;Zhao, Li;Tu, Bin;Yang, Fan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.10
    • /
    • pp.6069-6075
    • /
    • 2013
  • Background: At present, the diagnosis of colorectal cancer (CRC) requires a colorectal biopsy which is an invasive procedure. We undertook this pilot study to develop an alternative method and potential new biomarkers for diagnosis, and validated a set of well-integrated tools called ClinProt to investigate the serum peptidome in CRC patients. Methods: Fasting blood samples from 67 patients diagnosed with CRC by histological diagnosis, 55 patients diagnosed with colorectal adenoma by biopsy, and 65 healthy volunteers were collected. Division was into a model construction group and an external validation group randomly. The present work focused on serum proteomic analysis of model construction group by ClinProt Kit combined with mass spectrometry. This approach allowed construction of a peptide pattern able to differentiate the studied populations. An external validation group was used to verify the diagnostic capability of the peptidome pattern blindly. An immunoassay method was used to determine serum CEA of CRC and controls. Results: The results showed 59 differential peptide peaks in CRC, colorectal adenoma and health volunteers. A genetic algorithm was used to set up the classification models. Four of the identified peaks at m/z 797, 810, 4078 and 5343 were used to construct peptidome patterns, achieving an accuracy of 100% (> CEA, P<0.05). Furthermore, the peptidome patterns could differentiate the validation group with high accuracy close to 100%. Conclusions: Our results showed that proteomic analysis of serum with MALDI-TOF MS is a fast and reproducible approach, which may provide a novel approach to screening for CRC.

Estimation of Disease Code Accuracy of National Medical Insurance Data and the Related Factors (의료보험자료 상병기호의 정확도 추정 및 관련 특성 분석 -법정전염병을 중심으로-)

  • Shin, Eui-Chul;Park, Yong-Mun;Park, Yong-Gyu;Kim, Byung-Sung;Park, Ki-Dong;Meng, Kwang-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.3 s.62
    • /
    • pp.471-480
    • /
    • 1998
  • This study was undertaken in order to estimate the accuracy of disease code of the Korean National Medical Insurance Data and disease the characteristics related to the accuracy. To accomplish these objectives, 2,431 cases coded as notifiable acute communicable diseases (NACD) were randomly selected from 1994 National Medical Insurance data file and family medicine specialists reviewed the medical records to confirm the diagnostic accuracy and investigate the related factors. Major findings obtained from this study are as follows : 1. The accuracy rate of disease code of NACD in National Medical Insurance data was very low, 10.1% (95% C.I. : 8.8-11.4). 2. The reasons of inaccuracy in disease code were 1) claiming process related administrative error by physician and non-physician personnel in medical institutions (41.0%), 2) input error of claims data by key punchers of National Medical Insurer (31.3%) and 3) diagnostic error by physicians (21.7%). 3. Characteristics significantly related with lowering the accuracy of disease code were location and level of the medical institutions in multiple logistic regression analysis. Medical institutions in Seoul showed lower accuracy than those in Kyonngi, and so did general hospitals, hospitals and clinics than tertiary hospitals. Physician related characteristics significantly lowering disease code accuracy of insurance data were sex, age group and specialty. Male physicians showed significantly lower accuracy than female physicians; thirties and fortieg age group also showed significantly lower accuracy than twenties, and so did general physicians and other specialists than internal medicine/pediatric specialists. This study strongly suggests that a series of policies like 1) establishment of peer review organization of National Medical Insurance data, 2) prompt nation-wide expansion of computerized claiming network of National Medical Insurance and 3) establishment and distribution of objective diagnostic criteria to physicians are necessary to set up a national disease surveillance system utilizing National Medical Insurance claims data.

  • PDF

Control for a Yaw Error Compensation System of Linear Motor Stage (리니어모터 스테이지 편요오차 보상장치 제어)

  • Lee, Seung-Hyun;Kang, Min-Sig
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.10
    • /
    • pp.997-1005
    • /
    • 2008
  • Linear motor stage is a useful device in precision engineering field because of its simple power transmission mechanism and accurate positioning. Even though linear motor stage shows fine positioning accuracy along travel axis, geometric dependent errors which relay on machining and assembling accuracy should be addressed to increase total positioning performances. In this paper, we suggests a cost effective yaw error compensation servo-system which is mounted on platform of the stage and nullify travel position dependent yaw error. This paper also provides a method of designing a sliding mode control which is robust to existing friction disturbance and model uncertainties. The reachability condition of slinding mode control for the yaw error compensating servo-system has been established. From some experimental results by using an experimental set-up, the sliding mode control showed its effective in disturbance rejection and its performance was superior to conventional linear controls.

Carnegie Hubble Program II : Overview and Research Status

  • Yang, Soung-Chul
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.46.4-47
    • /
    • 2015
  • Carnegie Hubble Program II (hereafter CHP II) is a large Hubble Space Telescope (HST) observing campaign in the cycle 22 composed of a total of 184 orbits (132 primes + 52 parallels), which aims to measure H0 directly with an unprecedented accuracy. Unlike our previous efforts in CHP I which used Cepheids as a yardstick, CHP II takes the Population II (Pop II) distance indicators such as RR Lyraes and tip of the red giant branch stars (TRGBs) to set up a new calibration to Type Ia supernovae (SN Ia) distance. The Pop II distance scales have two immediate advantages over the classical Cepheid method: 1) The period-luminosity relation of the RR Lyrae has a scatter that is a factor of 2 smaller; 2) The RR Lyrae/TRGB distance scale can be applied to both elliptical and spiral galaxies. This will provide a great systematic benefit by ultimately allowing us to double the number of SN Ia distances based on geometry. By taking advantage of this Pop II route, we expect to measure H0 value to 3 % of error which will be the highest accuracy H0 measurement to date using the "Distance Ladder" method. In this talk I will present a brief background/overview on the CHP II, observations/data acquisition status, and ongoing research progress/preliminary results.

  • PDF

Detecting Lane Departure Based on GIS Using DGPS (DGPS를 이용한 GIS기반의 차선 이탈 검지 연구)

  • Moon, Sang-Chan;Lee, Soon-Geul;Kim, Jae-Jun;Kim, Byoung-Soo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.4
    • /
    • pp.16-24
    • /
    • 2012
  • This paper proposes a method utilizing Differential Global Position System (DGPS) with Real-Time Kinematic (RTK) and pre-built Geo-graphic Information System (GIS) to detect lane departure of a vehicle. The position of a vehicle measured by DGPS with RTK has 18 cm-level accuracy. The preconditioned GIS data giving accurate position information of the traffic lanes is used to set up coordinate system and to enable fast calculation of the relative position of the vehicle within the traffic lanes. This relative position can be used for safe driving by preventing the vehicle from departing lane carelessly. The proposed system can be a key component in functions such as vehicle guidance, driver alert and assistance, and the smart highway that eventually enables autonomous driving supporting system. Experimental results show the ability of the system to meet the accuracy and robustness to detect lane departure of a vehicle at high speed.

Runoff Forecasting Model by the Combination of Fuzzy Inference System and Neural Network (Fuzzy추론 시스템과 신경회로망을 결합한 하천유출량 예측)

  • Heo, Chang-Hwan;Lim, Kee-Seok
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.3
    • /
    • pp.21-31
    • /
    • 2007
  • This study is aimed at the development of a runoff forecasting model by using the Fuzzy inference system and Neural Network model to solve the uncertainties occurring in the process of rainfall-runoff modeling and improve the modeling accuracy of the stream runoff forecasting. The Neuro-Fuzzy (NF) model were used in this study. The NF model, recently received a great deal of attention, improve the existing Neural Networks by the aid of the Fuzzy theory applied to each node. The study area is the downstreams of Naeseung-chun. Therefore, time-dependent data was obtained from the Wolpo water level gauging station. 11 and 2 out of total 13 flood events were selected for the training and testing set of model respectively. The schematic diagram method and the statistical analysis are conducted to evaluate the feasibility of rainfall-runoff modeling. The model accuracy was rapidly decreased as the forecasting time became longer. The NF model can give accurate runoff forecasts up to 4 hours ahead in standard above the Determination coefficient $(R^2)$ 0.7. In the comparison of the runoff forecasting using the NF and TANK models, characteristics of peak runoff in the TANK model was higher than ones in the NF models, but peak values of hydrograph in the NF models were similar.