The evaluation for usefulness of the custom made immobilization device for the anteroperitoneal resection patients with rectal cancer (복 회음부 절제술 환자를 위한 고정용구 제작 및 유용성 평가)

  • Yang Oh Nam;Lee Woo Seok;Hong Tack Kyun;Jo Young Pil;Yun Hwa Ryong;Kim Jung Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.61-65
    • /
    • 2003
  • I. Purpose Patient immobilization is essential factor for successful radiation therapy and major problem is reproducibility to maintain patient position during total radiation therapy period. Purpose of this study is evaluation for usefulness of the custom made immobilization device for the anteroperitoneal resection patients with rectal cancer II. Materials and Methods The object of this study were patients who underwent anteroperitoneal resection and undergo radiation therapy at present with rectal cancer. We made immobilization device for patient individually and analyzed its set up reproducibility, patient position deviation and errors. III. Results There was $5mm{\sim}10mm$ deviation in patient position without individual immobilization device, but we improved the deviation within few mm limitation with individual immobilization device. IV. Conclusion Custom made immobilization device was very helpful for anteroperitoneal resection patient with rectal cancer. We improved the patient position deviation within few mm limitation, shorten the set up time and we could give the comfort to patients.

  • PDF

Arm-up holder의 보조기구 제작에 따른 유용성 평가

  • 이현직;최병기;심재구;김종식;오동균;박영환
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.85-88
    • /
    • 2002
  • I. 목적 : arm-up holder는 흉부 및 복부 질환 치료의 환자고정에 유용하게 사용하고 있으나 손잡이 부분과 어깨가 닿는 부분까지 거리 때문에 동일한 자세를 유지하는데 불편함이 있다. 특히 긴장을 많이 하거나 기력이 없는 환자는 방사선 치료 시 자세의 불안정으로 인하여 치료의 정확성이 떨어질 수 있다. 이에 본원에서는 현재 사용하고 있는 arm-up holder에 팔의 지지를 위한 보조기구를 제작하여 유용성을 평가하였다. II. 대상 및 방법 : 기존의 arm-up holder에 어깨받침대를 부착하여 개선된 arm-up holder를 제작하였다. 실험을 위하여 기존의 arm-up holder를 사용하는 환자그룹과 개선된 arm-up holder를 사용하는 그룹으로 구분하여 자세 변화를 평가하였다. 두 그룹의 환자를 대상으로 모의 치료를 실시한 후 치료실에서 L-gram 을 2회 씩 촬영하여 치료하고자 하는 portal film과 isocenter의 변화를 측정했다. 각 그룹 당 10명씩의 환자를 선정하여 반복 조사하였다. III. 결과 : 개선된 arm-up holder를 사용한 그룹의 isocenter 의 변화는 최대 2mm, 최소 0.5mm 평균 1.2mm 이다. 기존의 arm-up folder를 사용한 그룹과 비교하여 평균변화는 약 2배로 나라났고, 최대 변화는 2.5배의 오차범위가 측정되었다. IV. 결론 : 현재 사용하고 있는 arm-up holder는 흉부 및 복부의 사방향 방사선 치료 시 팔에 의한 방사선 감약을 예방할 수 있는 유용한 고정용구이다. 하지만 팔을 올리고 있는 자세는 환자에게 불편함을 야기 시키며 이로 인한 치료의 정확성을 감소시킬 수 있다. 따라서, 기존의 arm-up holder에 보조기구를 제작하여 사용함으로써 환자의 불편함을 개선하고, set-up 의 안정성과 재현성을 향상시킬 수 있었다.

  • PDF

Availability and Reproducibility Evaluation of High-dose-rate Intraluminal Brachytherapy for Unresectable Recurrent Cholangiocarcinoma (재발한 간담도암 환자에서 시행 한 high-dose-rate intraluminal brachytherapy의 유용성 및 재현성 평가)

  • Park, Ju-Kyeong;Lee, Seung-Hun;Cha, Seok-Yong;Kim, Yang-Su;Lee, Sun-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.151-157
    • /
    • 2012
  • General treatment for cholangiocarcinoma is complete surgical resection. However recurrence is common in those patients. In most of cases the purpose of the treatment for patients with recurrent is palliative. Therefore we adopt intraluminal catheter to treat a recurrent patient with high-dose-rate intraluminal brachytherapy. This study aims to evaluate the treatment procedure and set-up reproducibility of intraluminal brachytherapy in the recurrent patient. Study patient was diagnosed at rcT1N0M0 and undergone intraluminal brachytherapy after Arrow Sheath insertion. 3 Gy was delivered in every fraction with a total dose of 30 Gy. We planned dose normalization at distal, proximal and central axis point of narrowed bile duct far from 1 cm. To evaluate set-up reproducibility, we measured distance between distal, proximal treatment target volume point and anterior surface of the thoracic vertebral body respectively for five times before every treatment with dummy seed insertion. Mean distance between distal, proximal treatment target volume point and anterior surface of 10th and 11th thoracic vertebral bodies is 0.5 cm, 6.1 cm and standard deviation is 0.06, 0.08 respectively. In addition, set-up reproducibility was maintained significantly. The patient has been alive with no evidence of disease recurrence for more than a year and has not yet reported severe complications. In conclusion, high-dose-rate intraluminal brachytherapy for unresectable recurrence of cholangiocarcinoma maintains high set-up reproducibility without severe side effects.

Evaluation of the efficiency of the Vac-lock type belly board in Pelvic cancer Radiation Treatment (골반부 방사선치료 시 자체 제작한 Vac-lock type belly board에 대한 유용성 평가)

  • Kim, YoungYeun;Bang, Seungjae;Jung, Ilsun;Kim, Jungsu;Kim, YoungKon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.37-42
    • /
    • 2014
  • Purpose : At the time of the pelvis cancer radiation treatment using the belly board, set-up error is large because of a prone position. In order to improve the reproducibility, we made Vac-lock type belly board. In this study, we attempt to validate its utility. Materials and Methods : We compared belly board and Vac-lock type belly board through the OBI. OBI was performed three times with entire course of treatment and the setup errors in the direction of X axis, Y axis, Z axis were recorded and calculated the distance from the isocenter. Results : X axis, Y axis, Z axis setup errors with existing belly board were 0.32 cm, 0.41 cm, 0.29 cm. The setup errors with the vac-lock type belly board were 0.12 cm, 0.19 cm, 0.17 cm. Further, errors of 0~0.29 cm were increased from 48% to 83% when using VLT belly board. Error of 0.5 cm or more was reduced from 21% to 2%. Conclusion : Vac-lock type belly board is able to maintain the efficacy of existing and create to match the characteristics of the patient. Therefore We think that vac-lock type belly board is very useful in pelvic cancer patients.

Manufacture of Immobilization Device (Vac-lok) and the Usefulness of Evaluation for Reproducibility of Patients in the Radiotherapy (환자의 재현성을 위한 고정장치(Vac-lok) 제작과 방사선치료에서 유용성 평가)

  • Lee, Jae-Seung;Kim, Gyoung-Hee;Jeong, Kyu-Hwan;Kweon, Dae-Cheol;Goo, Eun-Hoe;Park, Cheol-Woo;Im, In-Chul;Dong, Kyung-Rae;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.1
    • /
    • pp.8-16
    • /
    • 2011
  • We manufactured the Vac-lok that can be applied to patient of special body shape and need to special set-up position and evaluated the usefulness in the radiation therapy. The manufacture Vac-lok, It was used EVA resin and biobeadform of a diameter 1.5 mm. carried out the test of functionality, structural and analyzed the relative reproducibility of phantoms and patients. During the total period of radiation therapy, Vacuum pressure bring variety to a very small amount in the test of functionality of the manufacture Vac-lok. But It was a negligible quantity. The manufacture Vac-lok improved the relative reproducibility of phantoms than the existing Vac-lok and tolerance has a confidence less than 4% error. Also, relative reproducibility of patient increased error than phantom in the antero-posterior and lateral plan. However, the maximum set-up error was less than ${\pm}\;2.3$ mm. In conclusion, If tolerance set-up error of radiotherapy is less than ${\pm}\;3$ mm, the manufacture Vac-lok was enough possible to use and improvement of reproducibility, considering supply with the Vac-lok made to measure of special patient that produced at a low price and without delay.

The Evaluation of Usefulness of the Manufactured DTAB (Double Tilt Angle Board) System (Double Tilt Angle Board (DTAB)의 자체 제작에 관한 유용성 평가)

  • Lee, Joung-Jin;Jang, In-Gi;Kim, Wan-Sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.43-51
    • /
    • 2006
  • Purpose: To resolution of A hospital-handmade modification double tilt angle immobilization system (DTAB immobilization system) and to report the clinical results of it. Material and Methods: It was developed in conjunction with the breast board for patients unable to achieve and maintain the desired uncomfortable respiration and position of set-up needed in the treatment of RT (This custom design provides an alternative to accomplishing this desired head angle needed to relax position treatment area, realizing that the lenses totally protected eye-ball out) By using the angled breast board and SBDD(small bowel device), reproducibility of set-up and patient comfort were addressed throughout the simulation, computed tomography planning and treatment process. Results: Usually patients the error range-within 5 mm. When use of Aqua patients error range-within 3 mm. Conclusion: It was constructed in tandem with a unique custom-built double tilt angle board (DTAB). It was designed to eliminate clinical set-up problems with head immobilization and instability during treatment, thus providing for a more comfortable head rest for the patient.

  • PDF

Isocenter Reproducibility with Mask Fixation System in Stereotactic Radiosurgery (정위 마스크 시스템을 사용한 방사선수술시 회전중심점의 재현성)

  • 이동준;손문준;이기택;최찬영;황금철;황충진
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.135-138
    • /
    • 2002
  • Fractionated stereotactic radiosurguy (FSRS) requires precise and reproducible patient set up. For these reasons non-invasive mask fixation methods have been used in Linac based FSRS. In this study, we measured and assessed the isocenter reproducibility using a commercial head mask fixation system based on thermoplastic materials. For the verification and the measurement of isocenter deviation a special acrylic brain phantom was designed. The designed phantom has 22 vertical rods and each rod has different lengths. At the end of the 8 rods, the monochromic film is attached and irradiated due to planned target position. Deviations of isocenter were measured separately for each direction. The mean deviation showed 0.4 mm in longitudinal direction, 0.1 mm in the lateral direction, 0.1 mm in the anterior-posterior direction of the treatment couch. The data demonstrates the high accuracy and reproducibility. This study reinforces previous literature published.

  • PDF

Analysis of Body Mass Index on Set Up Errors Rectal Cancer in Radiotherapy (체질량지수(BMI)와 방사선 치료 시 직장암 환자의 자세 오차 분석)

  • Shim, Jae-Goo;Jung, Hong-Ryang;Seo, Jung-Min;Park, Byoung Suk;Jang, Joon-Young
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2013.05a
    • /
    • pp.211-212
    • /
    • 2013
  • 방사선 치료를 받는 모든 환자의 경우 먼저 모의 치료를 시행한 후에 동일한 자세로 방사선 치료를 실시한다. 이 때 무엇보다도 중요한 사항은 정확한 자세의 재현성이다. 직장암 환자의 방사선 치료를 시행하는 경우에도 모의 치료와 동일한 자세 유지가 요구되어진다. 하지만 호흡 및 환자의 여러 가지 요소에 의해 자세의 오차가 발생할 수 있다. 이에 본 논문은 직장암 환자의 방사선 치료를 시행하는 경우 오차가 발생할 수 있는 요소 중에 환자의 체지량 지수 차이에 의한 자세 재현성에 대해 알아보고 향후 자세 오차를 줄일 수 있는 방법을 모색하고자 한다.

  • PDF

Evaluation of Manufactured Device for Radiation therapy in Head and Neck Cancer (두경부암 환자의 방사선 치료시 자체 제작한 고정용구 (Shoulder Retractor)에 대한 유용성 평가)

  • Kim, Tae Jun;Jin, Sun Sik;Kim, Dong Hyun;Kim, Dong Wook;Chung, Weon Kuu;Kim, Kyoung Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.99-105
    • /
    • 2014
  • Purpose : We compared the set-up accuracy and right-left Shoulder position variation of the manufactured device and other commercial shoulder-retractors in the head and neck radiation treatment. Materials and Methods : Six patients consist of three groups which were used three different Shoulder retractors. We measured position corrections of left and right Shoulder and the couch after the image guidance by using on board imager (OBI) for six head and neck patients who has the extended target to the neck node lower region. Results : The position variation correction of left (right) Shoulder after image guidance were $1.07{\pm}3.99mm$ ($-4.35{\pm}2.09mm$), $-0.37{\pm}5.91mm$ ($1.26{\pm}5.28mm$), $-0.63{\pm}2.44mm$ ($0.25{\pm}1.61mm$) for group A, B and C. The vertical, lateral, longitudinal position and angular corrections of the couch after image guidance were $-2.06{\pm}2.68$, $-1.11{\pm}8.15$, $0.34{\pm}3.78mm$, and $0.51{\pm}0.77$ degree for group A, $-1.18{\pm}1.82$, $-0.94{\pm}2.13$, $-0.67{\pm}1.98mm$, and $0.91{\pm}1.04$ degree for group B and $0.12{\pm}2.18$, $-0.79{\pm}2.64$, $0.79{\pm}2.64$, and $0.00{\pm}0.49$ degree for group C. Conclusion : In this preliminary study, we found the positioning accuracy of the manufactured Shoulder retractor is comparable to other commercial Shoulder retractors. We expect that the reproducibility and accuracy of the patient set-up could be improved by using the home made Shoulder retractor in the head and neck radiation treatment.