• Title/Summary/Keyword: serviceability evaluation

Search Result 193, Processing Time 0.036 seconds

Serviceability Performance Evaluation of Vertical Vibration of Waflle Shape and Duble-Tee Precast Concrete Slabs (와플형과 더블티형 프리캐스트 콘크리트 바닥판의 수직진동 사용성 평가)

  • Shin, Jae-Sang;Chung, Lan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.62-69
    • /
    • 2010
  • In this study, the serviceability performance of Waffle Shaped(WAS) and Double-Tee(DT) precast concrete slabs were evaluated and compared based on the vertical acceleration magnitude induced by walking and heel drop loads. Tests were conducted for practical building structures of which floor systems used WAS and DT slabs. Natural frequencies of the slabs were similar to those obtained by using analytical models. The measured acceleration level was evaluated by vertical floor acceleration criteria presented by ISO-2631, AIJ(1991, Japan) and a previous study regarding floor vibration limit. Test results showed that both WAS and DT slabs satisfied all the criteria and Peak acceleration level of WA slabs was lower than that of DT slabs.

Vibration Serviceability Evaluation for Pedestrian of Concrete Cable-stayed Bridge by Experimental Method (실험적 방법에 의한 콘크리트 사장교의 보행자 중심 진동사용성 평가)

  • Kang, Sung-Hoo;Choi, Bong-Hyun;Park, Sun-Joon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.2
    • /
    • pp.59-66
    • /
    • 2011
  • In this study, the vibration serviceability of pedestrian by travelling vehicles on the cable-stayed bridge with concrete tower was studied. Experiment variables were considered travelling speed of vehicles, pavement state of asphalt on the deck and weight of vehicles, preferentially. Especially, pavement grade states were considered by A and C grades by BMS (Bridge Management System) standard. The incremental ratio extent of vibration acceleration responses, asphalt pavement grade C over A, was construed to 1.23~1.43. Only, these results are valid within extent of the Scaled-Weight 228.0~1161.9 km/h kN. The vibration equations for acceleration responses prediction of bridge deck were proposed into three types, reliability 50%, 90%, 95% respectively. These equations can consider asphalt pavement grade, and the vehicle's weight and travelling velocity, which are the source of vibration, are combined into the term called, 'Scaled Weight'.

Vibration Serviceability Evaluation of a Single Span Steel-Concrete Composite Foot Bridge under Dynamic Pedestrian Loadings Considering Moving Mass Effect (이동 질량 효과를 고려한 단경간 강합성 보행교의 보행 하중 진동 사용성 평가)

  • Wonsuk Park
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.36 no.2
    • /
    • pp.75-83
    • /
    • 2023
  • In this paper, we present the analysis results on the vibration serviceability of a pedestrian bridge considering the effect of pedestrian moving mass inertia. Using dynamic finite element analysis, we considered different walking scenarios, including pedestrian density, walking speed, random walking, and synchronized walking, to analyze the acceleration response of a 40m long single-span bridge with a steel composite box cross section. We showed that the equivalent fixed mass analysis method did not significantly differ from the moving mass analysis in the random walk scenario and a wider frequency excitation band may be useful to consider when evaluating vibration serviceability in a random walk scenario.

Evaluation of Surface Coating Materials of Concrete for Protection of Chloride Attack (염해방지를 위한 콘크리트 표면도장재료의 성능평가)

  • 정해문;유환구;이병덕;안태송;오병환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.749-754
    • /
    • 2002
  • The safety and serviceability of concrete structures are influenced by corrosion of steel bars in concrete. Several methods have been available to protect the reinforcing bars from corrosion. Among them, the surface coating method is one of the easiest way to apply to concrete structures. However, the realistic guideline for surface coating materials has not been established yet in this country. In this study, in order to establish a reasonable technical guidelines which include the test method, quality criteria, and construction method, the performances of surface coating materials were evaluated.

  • PDF

A Comparative Study on the Floor Vibration Evaluation methods of Flat Plate Slab System (플랫슬래브 바닥구조시스템의 진동계산식의 비교)

  • Kang, Dae-Eon;Kim, Jong-Ho;Kim, Ji-Dong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.153-156
    • /
    • 2008
  • The serviceability evaluation methods regarding floor vibration can be found in foreign building codes or design guides for vibration. AISC, AIJ, CEN, CSA and ISO are sucn examples. However, because the those guides are based on each country's experimental results, there will be different evaluation results for the same conditions. Meanwhile, in korea, we have little research results that suits for our condition, and we continue to use those foreing guides. In this paper, 20 flat plate slabs were carried out to investigate the accuracy of existing frequency formulas.

  • PDF

Wind Induced Vibration Design for High-rise buildings through Control of Natural Period (주기 조절을 이용한 고층 건물의 풍응답 조절 설계)

  • 김지은;차성희;서지현;박효선
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.43-51
    • /
    • 2004
  • As the slenderness ratio of a high-rise building increases, the lateral load resisting system for the building is more often determined by serviceability design criteria. In serviceability design, the maximum drift and the level of vibration are controlled not to exceed the design criteria. Even though many drift method have been developed in various forms, no practical design method for wind induced vibration has been developed so far. Structural engineers rely upon heuristic or experience in designing wind induced vibration. Development of practical design method for wind induced vibration is required. Generally, wind induced acceleration responses are depending on several variables such as the weight density of a building, damping ratio, the natural period, and etc.. All parameters except the natural period or frequency are usually out of reach for structural engineers, then the wind acceleration response may be proportioned to the natural period. Therefore, in this paper, a wind induced vibration design method based on frequency control technique for high-rise is proposed. The method is applied to vibration design of a 25-story office building for performance evaluation.

  • PDF

Assessment Model for the Safety and Serviceability of Structures using Terrestrial LiDAR (지상라이다를 이용한 구조물의 안전 및 사용성 평가 모델)

  • Lee, Hong-Min;Park, Hyo-Seon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.3 s.22
    • /
    • pp.17-28
    • /
    • 2006
  • Structural health monitoring is important to maintain the safety and serviceability of the structures. The displacement in the structure should be precisely and frequently monitored because it is a direct assessment index indicating its stiffness. However, no practical method has been developed to monitor such displacement precisely, particularly for high-rise buildings and long span bridges because they cannot be easily accessible. To overcome such difficult accessibility, we propose to use a LIDAR system that remotely samples the surface of an object using laser pulses and generates the coordinates of numerous points on the surface. In this study, using terrestrial LiDAR, we develop a novel displacement measuring model for structural health monitoring and perform an indoor experiment to prove its performance.

Application of LRBs for Reduction of Wind-Induced Responses of Coupled Shear Wall Structures (전단벽 구조물의 풍응답 저감을 위한 LRB의 적용)

  • Park, Yong-Koo;Kim, Hyun-Su;Ko, Hyun;Kim, Min-Gyun;Lee, Dong-Guen
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.1
    • /
    • pp.47-56
    • /
    • 2011
  • In general, shear walls are employed as lateral resistance system. Most of shear wall structures require openings in shear walls and thus shear walls are linked by floor slabs or coupling beams resulting in the coupled shear wall structures. In this study, an LRB (lead rubber bearing) was introduced in the middle of the coupling beam of the coupled shear wall structures and the wind-induced response reduction effect of this system was investigated. In order to evaluate the control performance of the proposed method, 20- and 30-story building structures were used as example structures and boundary nonlinear time history analyses have been performed using artificial wind excitation. Japanese vibration evaluation criteria was employed to evaluate whether the proposed system could improve the serviceability of the tall coupled shear wall structures under wind excitation. Based on analytical results, it has been shown that the proposed method that connects shear walls with LRBs can improve the wind-induced response control effect.

Applicability Evaluation of Precast Deck to the Maglev Guideway System : Mock-Up Construction Test (프리캐스트 바닥판의 자기부상열차 가이드웨이 시스템 적용성 평가 : 모의 시공 실험)

  • Jin, Byeong-Moo;Kim, In-Gyu;Kim, Young-Jin;Oh, Hyung-Chul;Ma, Hyang-Wook;Lee, Yung-Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.57-60
    • /
    • 2008
  • Maglev is a system that a train runs levitated above a rail. Therefore it is very important to maintain a constant levitation gap for achieving serviceability and ride comfort. This study is a cooperation research subject of the 3-1 subject, performance improvement of maglev track structures, of the Center for Urban Maglev Program in Korea, started in 2006. The aim of this study is development of rapid constructions of bridge superstructure for maglev. At present, precast deck is widely used because of its superiority to cast-in-place concrete on quality and the term of works. The research group suggested basic systems of maglev guideway with PSC-U type and trapezoidal open steel box type girder, and precast deck, cooperating with Korea Railroad Research Institute, the managing institute of the 3-1 subject. In this study, a mock-up consisted of girders, decks and rail was fabricated and test was performed for constructability, serviceability and maintenance evaluation of PSC U-type girder, precast deck, and new guide rail system.

  • PDF

The Vibration Comfort Evaluation of the Shaking Table Mass Foundation (진동대 반력기초의 진동사용성 평가)

  • Choi, Hyoung-Suk;Jung, Da-Jung;Kim, Seong-Do;Cheung, Jin-Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.53-60
    • /
    • 2011
  • When designing building structures, dynamic serviceability is one of the most important items. Much research is being carried out on machine vibrations that affect inside residents and expensive equipment in the building structure. The vibration effect generally depends on the mass ratio, and an adequate mass ratio is determined by comparison with the serviceability limit according to the criteria. This study investigates the evaluation of vibration serviceability by using ISO 2631 to confirm the propriety of adequate mass ratios and it is verified that the application of a complicated FE model to model the real large shaking table facility with the mathematical model simulated as a SDOF system. The weighted RMS value is then compared with the comfort limit given by ISO 2631. As a result, the analysis of the numerical model is consistent with analysis of the FE model. Moreover, it is found that the adequate mass ratio of the concrete foundation and shake table, considering the self-weight of the real facility, should be less than 0.013. It is also confirm that the sample facility is satisfies the requirement of an adequate mass ratio.