• Title/Summary/Keyword: serpentine

Search Result 224, Processing Time 0.022 seconds

Real-Time Detection of Residual Free Chlorine and pH in Water Using a Microchannel Device

  • Kim, Sam-Hwan;Choi, Ju-Chan;Lee, June-Kyoo;Kong, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.368-374
    • /
    • 2011
  • A microfluidic device for real-time monitoring of residual free chlorine and pH in water based on optical absorption is proposed. The device consists of a serpentine micromixer for mixing samples with a reagent, and a photodiode and light emitting diode(LED) for the detection of light absorbance at specific wavelengths, determined for specific reagent combinations. Spectral analyses of the samples mixed with N, N'-diethyl-p-phenylenediamine(DPD) reagent for chlorine determination and bromothymol blue(BTB) for pH measurement are performed, and the wavelengths providing the most useful linear changes in absorbance with chlorine concentration and pH are determined and used to select the combination of LED and photodiode wavelengths for each analyte. In tests using standard solutions, the device is shown to give highly reproducible results, demonstrating the feasibility of the device for the inexpensive and continuous monitoring of water quality parameters with very low reagent consumption.

Role of network geometry on fluid displacement in microfluidic color-changing windows

  • Ucar, Ahmet Burak;Velev, Orlin D.;Koo, Hyung-Jun
    • Smart Structures and Systems
    • /
    • v.18 no.5
    • /
    • pp.865-884
    • /
    • 2016
  • We have previously demonstrated a microfluidic elastomer, which changes apparent color and could have potential applications in smart windows. The practical use of such functional microfluidic systems requires rapid and uniform fluid displacement throughout the channel network with minimal amount of liquid supply. The goal of this simulation study is to design various microfluidic networks for similar applications including, but not limited to, the color-switching windows and compare the liquid displacement speed and efficiency of the designs. We numerically simulate and analyze the liquid displacement in the microfluidic networks with serpentine, parallel and lattice channel configurations, as well as their modified versions with wide or tapered distributor and collector channels. The data are analyzed on the basis of numerical criteria defined to evaluate the performance of the corresponding functional systems. We found that the lattice channel network geometry with the tapered distributors and collectors provides most rapid and uniform fluid displacement with minimum liquid waste. The simulation results could give an important guideline for efficient liquid supply/displacement in emerging functional systems with embedded microfluidic networks.

Muscle-Inspired Serially-Connected Digital Actuators for Low-Voltage, Wide-Range, High-Precision Displacement Control (저전압 대변위 고정도 구동을 위한 근육모사 직렬연결 디지털 구동기)

  • Lee, Jae-Yong;Lee, Won-Chul;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • This paper presents muscle-inspired serial digital actuators, achieving the improvement of the range-to-precision and range-to-voltage performance. We propose a weight-balanced design for the serial actuators with serpentine springs using serial arrangement of digital actuators. We have measured the displacement range, precision, and drive voltage at unit and serial actuation of 1Hz. The serial digital actuators produce a full range displacement of $28.44{\pm}0.02{\mu}m$, accumulating the unit displacement of $2.8{\pm}0.5{\mu}m$ at the operating voltage of $4.47{\pm}0.07V$. In addition, the serial digital actuators having the displacement precision of $37.94{\pm}6.26nm$ do not accumulate the precision of the unit actuators, $36.0{\pm}17.7nm$. We experimentally verify that the serial digital actuators achieve the range-to-squared-voltage ratio of $1.423{\mu}m/V^2$ and the range-to-precision ratio of 749.6.

Experimental and Numerical Study of Thermal Properties about various forms of Micro-heater (다양한 형상을 갖는 마이크로 히터의 열특성에 관한 실험 및 전산해석적 연구)

  • Kim, Jin-Woo;Kim, Jae-Choon;Lee, Jun-Yub;Chung, Jin-Taek
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1957-1962
    • /
    • 2008
  • As a field of MEMS, micro-heater fabricated by Au is being introduced and developed in recent years. Previous studies about thermal properties of various forms of micro-heater were not sufficient. In this work, numerical and experimental analysis of the heat generation and the temperature distribution of micro-heater packages for 8 different geometric cases were studied. We fabricated a micro-heater package with silicon wafer, on which Cr/Au layer was laminated before 8 geometric forms of micro-heater were patterned. In each cases, temperature distribution was measured with IR thermal camera. According to the experimental results, which show a good agreement with the results analyzed by CFD, it was found that at 0.5W, the temperature of micro-heater chip which contained $20000{\mu}m$-long, serpentine shaped micro-heater was elevated to a relatively high temperature of $78^{\circ}C$ Consequently, we proposed a geometry of micro-heater which has effective thermal characteristics.

  • PDF

Mg-skarn Minerals from Magnetite Deposits of the Janggun Mine, Korea (장군광산(將軍鑛山)의 자철석광상(磁鐵石鑛床)에서 산출(産出)되는 Mg-스카른광물(鑛物))

  • Lee, Chan Hee;Song, Suckhwan;Lee, Hyun Koo
    • Economic and Environmental Geology
    • /
    • v.29 no.1
    • /
    • pp.11-21
    • /
    • 1996
  • The first Mg-skarn minerals are found from magnetite ore deposits of the Janggun mine, Korea. The skarn minerals are composed of mostly chondrodite, olivine, chlorite, serpentine, phlogophite, talc, apatite, magnesite, dolomite, siderite and trace amount of clinopyroxene, amphibole, garnet, wollastonite associated with magnetite, pyrrhotite and pyrite. The skarn zone is developed in the magnetite deposits at the contact of the Mg-rich Janggun Limestone Formation and the Chunyang granite. The chondrodites are columnar and radial shapes and some of them show twins. The chemical compositions of twinning-type chondrodites have high FeO (4.63 to 5.6 wt%), MnO (0.26 to 0.46 wt%) and low MgO (55.02 to 56.18 wt%) relative to the radial-type chondrodites. Twinning in chondrodite has been formed in close relation to substitution between Mg and Fe + Mn in humite solid solution. Temperature, $-logfo_2$ and $X_{CO2}$ during the skarn stage of magnetite deposits from the Janggun mine range from 395 to $430^{\circ}C$, from 30.5 to 31.2 atm and from 0.06 to 0.09, respectively.

  • PDF

Crystallization Mechanism of Slag-based Glass in $CaO-MgO-Al_2O_3-SiO_2(-Na_2O)$ System (Slag 위주의 $CaO-MgO-Al_2O_3-SiO_2(-Na_2O)$계 유리의 결정화 반응기구)

  • 장승현;정형진
    • Journal of the Korean Ceramic Society
    • /
    • v.17 no.1
    • /
    • pp.20-26
    • /
    • 1980
  • The crystallization behaviors of slag-based glass in $CaO-MgO-Al_2O_3-SiO_2(-Na_2O)$ system have been studied. The mother glass containing 16.50 CaO, 7.50MgO, 19.70Al2O3, 50.80SiO3 and 2.09wt% $Na_2O$ was prepared by using Korean domestic raw materials such as granulated slag, serpentine, sea sand and etc. The glass-ceramics composed of major crystalline phase diopside was produced by the heat treatment in a temperature range from 850$^{\circ}$ to 9$25^{\circ}C$ for 0-6hr. The composition and morphology of diopside phase formed in the system were examined by X-ray diffraction analysis and electron microscopy. The kinetic measurements such as J.M. A plot and Arrhenius plot indicated that the process of nucleation of the initially formed diopside phase could be described from the view point of instantaneous nucleation. It was also demonstrated that the linear crystal growth of diopside phase was proceeded by short range diffusion of $Mg^{2+}$ and $Ca^{2+}$ ion. The microstructures of the resulting glass-ceramics were consisted of leafroidal shaped crystalline aggregations.

  • PDF

An integrated DNA barcode assay microdevice for rapid, highly sensitive and multiplex pathogen detection at the single-cell level

  • Jung, Jae Hwan;Cho, Min Kyung;Chung, So Yi;Seo, Tae Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.276-276
    • /
    • 2013
  • Here we report an integrated microdevice consisting of an efficient passive mixer, a magnetic separation chamber, and a capillary electrophoretic microchannel in which DNA barcode assay, target pathogen separation, and barcode DNA capillary electrophoretic analysis were performed sequentially within 30 min for multiplex pathogen detection at the single-cell level. The intestine-shaped serpentine 3D micromixer provides a high mixing rate to generate magnetic particle-pathogenic bacteria-DNA barcode labelled AuNP complexes quantitatively. After magnetic separation and purification of those complexes, the barcode DNA strands were released and analyzed by the microfluidic capillary electrophoresis within 5 min. The size of the barcode DNA strand was controlled depending on the target bacteria (Staphylococcus aureus, Escherichia coli O157:H7, and Salmonella typhimurium), and the different elution time of the barcode DNA peak in the electropherogram allows us to recognize the target pathogen with ease in the monoplex as well as in the multiplex analysis. In addition, the quantity of the DNA barcode strand (~104) per AuNP is enough to be observed in the laser-induced confocal fluorescence detector, thereby making single-cell analysis possible. This novel integrated microdevice enables us to perform rapid, sensitive, and multiplex pathogen detection with sample-in-answer-out capability to be applied for biosafety testing, environmental screening, and clinical trials.

  • PDF

Technology of Stretchable Interconnector and Strain Sensors for Stretchable Electronics (신축성 전자소자를 위한 신축성 전극 및 스트레인 센서 개발 동향)

  • Park, Jin Yeong;Lee, Won Jae;Nam, Hyun Jin;Choa, Sung-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.4
    • /
    • pp.25-34
    • /
    • 2018
  • In this paper, we review the latest technical progress and commercialization of stretchable interconnectors, stretchable strain sensors, and stretchable substrates for stretchable electronics. The development of stretchable electronics can pave a way for new applications such as wearable devices, bio-integrated devices, healthcare and monitoring, and soft robotics. The essential components of stretchable electronic devices are stretchable interconnector and stretchable substrate. Stretchable interconnector should have high stretchability and high electrical conductivity as well as stability under severe mechanical deformation. Therefore several nanocomposite-based materials using CNT, graphene, nanowire, and metal flake have been developed. Geometric engineering such as wavy, serpentine, buckled and mesh structure has been well developed. Stretchable substrate should also pose high stretchability and compatibility with stretchable sensing or interconnecting material. We summarize the recent research results of new materials for stretchable interconnector and substrate as well as strain sensors. The Important challenges in development of the stretchable interconnector and substrate are also briefly discussed.

An Unusual Presentation of Extensive Ductal Carcinoma in Situ Accompanying Invasive Ductal Carcinoma on MRI: A Case Report (침윤성 유방암에 동반된 광범위한 관상피내암의 비전형적 자기공명영상 소견: 증례 보고)

  • Yeon Jung Kim;Hyun Kyung Jung;Woogyeong Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.4
    • /
    • pp.898-903
    • /
    • 2022
  • The incidence of ductal carcinoma in situ has increased with the rise in screening mammography; currently, ductal carcinoma in situ constitutes 20%-25% of all breast cancers, and up to half of them may become invasive. Its early detection is critical in improving the cure rate. Moreover, MRI has higher sensitivity for its detection than mammography. Herein, we report an unusual case of ductal carcinoma in situ presenting as a continuous, serpentine, linear enhancement with regional distribution on MRI.

A Study of Costumes in the $Lo{\ddot{i}}e$ Fuller's Dance (로이 풀러의 무대 의상에 관한 연구)

  • Choi, Yoo-Jin
    • The Research Journal of the Costume Culture
    • /
    • v.16 no.5
    • /
    • pp.878-890
    • /
    • 2008
  • As a pioneer of modem dance, $Lo{\ddot{i}}e$ Fuller($1869\sim1928$) was important because she introduced a free style dance using a new style of stage costumes. Also, $Lo{\ddot{i}}e$ Fuller was an important motif in $fin-de-si{\grave{e}}cle$, French arts, posters, sculptures, and so forth. This study aimed to clarify the characteristics of Fuller's dance and costumes, and to analyze the modernism in both. To better understand Fuller's dance, this article talks about research on Fuller's career, dance, and Fuller's own biography. Stage costumes, letters for patent, and photographs were are also studied. The most important elements of Fuller's dance were her costumes and the electric lights which could make free style expressions a fantastic representation of dance. To clarify the modernity of Fuller's dance, first of all, this study researched Fuller's career in dance and then analyzed representations of Fuller's dances in visual arts; posters, sculptures and lastly, the characteristics of Fuller's stage costumes. As a result, this article analyzed characteristics of Fuller's dance in three points. First, Fuller used sculptures of silk cloth's drapery to express physical movements and actions. Second, Fuller used lighting and electrical effects that had just been developed in the late 19th Century. Third, Fuller made an application for patents against stage costume and stage mechanisms for her original shows. This study focused on $Lo{\ddot{i}}e$ Fuller's stage costumes which played a main role in expressing fantastic sculptures for the first time in costume, visual arts, and dance studies. This study clarifies the characteristics of the stage costumes in Fuller's dance and is estimated as pioneering and fundamental research.

  • PDF