• Title/Summary/Keyword: serotonin (5-hydroxytryptamine

Search Result 63, Processing Time 0.02 seconds

Effects of Electrolytes and Drugs on the Inhibitory Junction Potentials Recorded from the Antrum of Guinea-pig Stomach (기니피그 유문동에서 기록되는 억제성 접합부 전압에 미치는 전해질과 약물의 효과)

  • Goo, Yong-Sook;Suh, Suk-Hyo;Lee, Suk-Ho;Hwang, Sang-Ik;Kim, Ki-Whan
    • The Korean Journal of Physiology
    • /
    • v.24 no.1
    • /
    • pp.1-13
    • /
    • 1990
  • The effects of electrolytes, adenosine, ATP, 5-hydroxytryptamine (5-HT, serotonin) and ketanserin on the inhibitory junction potentials (IJPs) were investigated to clarify the interactions of these drugs with the neurotransmitters released from non-adrenergic, non-cholinergic nerves in the antrum of guinea-pig stomach. Electrical responses of antral circular muscle cells were recorded intracellularly using glass capillary microelectrode filled with 3 M KCI. All experiments were performed in Tris-buffered Tyrode soluition which was aerated with 100% $O_{2}$ and kept at $35^{\circ}C$. The results obtained were as follows: 1) Inhibitory junction potential (IJP) was recorded in antral strip, while excitatory junction potential (EJP) was recorded in fundic strip. 2) IJP recorded in antral strip was not influenced by atropine $(10^{-6}\;M)$ and guanethidine $(5{\times}10^{-6})$. 3) The amplitude of IJP increased in high $Ca^{2+}$ solution, while that of IJP decreased in high $Mg^{2+}$ solution or by $Ca^{2+}$ antagonist (verapamil). Apamin, $Ca^{2+}$-activated $K^{+}$ channel blocker blocked IJP completely. 4) ATP and adenosine decreased the amplitude of IJP. 5) 5-HT decreased the amplitude of IJP with no change of the amplitude of slow waves, while ketanserin (5-HT type 2 blocker) decreased the amplitude of slow waves markedly with no change in that of IJP. From the above results, the following conclusions could be made. 1) IJP recorded in antral strip is resulted from neurotransmitters released from non-adrenergic, non-cholinergic nerves. 2) An increase in the concentration of external $Ca^{2+}$ enhances the release of neurotransmitters from non-adrenergic, non-cholinergic nerves which activate the $Ca^{2+}$-dependent $K^{+}$ channel.

  • PDF

Torque and mechanical failure of orthodontic micro-implant influenced by implant design parameters (교정용 마이크로 임플란트의 디자인이 토오크와 파절강도에 미치는 영향)

  • Yu, Won-Jae;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.37 no.3 s.122
    • /
    • pp.171-181
    • /
    • 2007
  • Objective: The present study was aimed at an analytical formulation of the micro-implant related torque as a function of implant size, i.e. the diameter and length, screw size, and the bony resistance at the implant to bone interface. Methods: The resistance at the implant to cancellous bone interface $(S_{can})$ was assumed to be in the range of 1.0-2.5 MPa. Micro-implant model of Absoanchor (Dentos Inc. Daegu, Korea) was used in the course of the analysis. Results: The results showed that the torque was a strong function of diameter, length, and the screw height. As the diameter increased and as the screw size decreased, the torque index decreased. However the strength index was a different function of the implant and bone factors. The whole Absoanchor implant models were within the safe region when the resistance at the implant/cancellous bone $(=S_{can})$ was 1.0 or less. Conclusion: For bone with $S_{can}$ of 1.5 MPa, the cervical diameter should be greater than 1.5 mm if micro-implant models of 12 mm long are to be placed. For $S_{can}$ of 2.0 MPa, micro-implant models of larger cervical diameter than 1.5 mm were found to be safe only if the endosseous length was less than 8 mm.

Effect of Ketanserin and Positive End Expiratory Pressure Ventilation on Hemodynamics and Gas Exchange in Experimental Acute Pulmonary Embolism (실험적 급성 폐동맥색전증에서 Ketanserin과 Positive End Expiratory Pressure Ventilation이 혈류역학 및 환기에 미치는 영향)

  • Lee, Sang-Do;Lee, Young-Hyun;Han, Sung-Koo;Shim, Young-Soo;Kim, Keun-Youl;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.2
    • /
    • pp.135-146
    • /
    • 1993
  • Background: In acute pulmonary embolism it has been postulated that the constriction of bronchi and pulmonary artery secondary to neurohumoral response plays an important role in cardiopulmonary dysfunction in addition to the mechanical obstruction of pulmonary artery. Serotonin is considered as the most important mediator. Positive end expiratory pressure (PEEP) stimulates $PGI_2$ secretion from the vascular endothelium, but its role in acute pulmonary embolism is still in controversy. Methods: To study the cardiopulmonary effect and therapeutic role of Ketanserin, selective antagonist of 5-HT2 receptor, and PEEP in acute pulmonary embolism experimental acute pulmonary embolism was induced in dogs with autologous blood clot. The experimental animals were divided into 3 groups, that is control group, Ketanserin injection group and PEEP application group. Results: Thirty minutes after embolization, mean pulmonary arterial pressure and pulmonary vascular resistance increased and cardiac output decreased. $PaO_2,\;P\bar{v}O_2$ and oxygen transport decreased and physiological shunt and $PaCO_2$ increased. After injection of Ketanserin, comparing with control group, mean pulmonary arterial pressure, pulmonary vascular resistance and physiological shunt decreased, while cardiac output, $PaO_2$ and oxygen transport increased. All these changes sustained till 4 hours after embolization. After PEEP application pulmonary vascular resistance, $PaO_2$ and $PaCO_2$ increased, while physiological shunt, cardiac output and oxygen transport decreased. After discontinuation of PEEP, mean pulmonary arterial pressure and pulmonary vascular resistance decreased and were lower than control group, while $PaO_2$ and cardiac output increased and higher than control group. $PaCO_2$ decreased but showed no significant difference comparing with control group. Conclusion: It can be concluded that Ketanserin is effective for the treatment of acute pulmonary embolism. With PEEP hemodynamic status deteriorated, but improved better than control group after discontinuation of PEEP. Thus PEEP may be applied carefully for short period in acute pulmonary embolism if the hemodynamic status is tolerable.

  • PDF