• Title/Summary/Keyword: sequence images

Search Result 583, Processing Time 0.033 seconds

A Study of Automatic Vehicle Control by Image Processing (화상처리 기술을 이용한 자동차 교통 제어에 관한 연구)

  • Choe, Hyeong-Jin;Yang, Hae-Sul
    • The Transactions of the Korea Information Processing Society
    • /
    • v.1 no.3
    • /
    • pp.418-426
    • /
    • 1994
  • Auto Navigation System is to provide a vehicle driver with more driving information by developing a computer-based system which supports advanced knowledge to a vehicle driving automation system and a driver. In this paper, we propose a new algorithm for the extraction of passing car which removes a background region using a series of images. First, we generate two difference images from three original images by getting the difference values between every two of them in sequence. Second, we generate two mask images from the two difference images. Finally, we extract passing car using the one original image and the two mask images. Using this algorithm we can extract the moving object in the outdoors.

  • PDF

An End-to-End Sequence Learning Approach for Text Extraction and Recognition from Scene Image

  • Lalitha, G.;Lavanya, B.
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.7
    • /
    • pp.220-228
    • /
    • 2022
  • Image always carry useful information, detecting a text from scene images is imperative. The proposed work's purpose is to recognize scene text image, example boarding image kept on highways. Scene text detection on highways boarding's plays a vital role in road safety measures. At initial stage applying preprocessing techniques to the image is to sharpen and improve the features exist in the image. Likely, morphological operator were applied on images to remove the close gaps exists between objects. Here we proposed a two phase algorithm for extracting and recognizing text from scene images. In phase I text from scenery image is extracted by applying various image preprocessing techniques like blurring, erosion, tophat followed by applying thresholding, morphological gradient and by fixing kernel sizes, then canny edge detector is applied to detect the text contained in the scene images. In phase II text from scenery image recognized using MSER (Maximally Stable Extremal Region) and OCR; Proposed work aimed to detect the text contained in the scenery images from popular dataset repositories SVT, ICDAR 2003, MSRA-TD 500; these images were captured at various illumination and angles. Proposed algorithm produces higher accuracy in minimal execution time compared with state-of-the-art methodologies.

Gradual Encryption of Medical Image using Non-linear Cycle and 2D Cellular Automata Transform

  • Nam, Tae Hee
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.11
    • /
    • pp.1279-1285
    • /
    • 2014
  • In this paper, we propose on image encryption method which uses NC(Non-linear Cycle) and 2D CAT(Two-Dimensional Cellular Automata Transform) in sequence to encrypt medical images. In terms of the methodology, we use NC to generate a pseudo noise sequence equal to the size of the original image. We then conduct an XOR operation of the generated sequence with the original image to conduct level 1 NC encryption. Then we set the proper Gateway Values to generate the 2D CAT basis functions. We multiply the generated basis functions by the altered NC encryption image to conduct the 2nd level 2D CAT encryption. Finally, we verify that the proposed method is efficient and extremely safe by conducting an analysis of the key spatial and sensitivity analysis of pixels.

Mn-DPDP enhanced MR imaging in Detection of Focal Hepatic lesion: Evaluation of the Efficacy & Optimization of Pulse Sequence (국소간의 자기공명영상에서 Mn-DPDP의 유용성과 적합한 MR Sequence에 관한 비교, 고찰)

  • Kim Eun Seong;Kim Dae Hyeon;Lee Hyeon Geun;O Geun Taek;Lee Sun No;Lee U Sik
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.104-114
    • /
    • 2001
  • Ⅰ. Purpose : To evaluate the diagnostic value of Mn-DPDP for the detection of focal hepatic lesions on MR images and to determine the optimal pulse sequence to maximize its effect. Ⅱ. Material and Methods : Twenty-eight patients(6 women and 22 men, aged f

  • PDF

Perfusion RRI of the Brain Using Oxygen Inhalation (산소 호흡을 이용한 뇌의 관류 자기공명영상)

  • 최순섭
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.113-119
    • /
    • 2000
  • Purpose : To know the possibility of clinical application of MRI using oxygen inhalation as a perfusion MRI Materials and methods : Two healthy volunteers and three patients of one moyamoya disease, one acute infarction and one meningioma were studied using a 1.5 Tesla MRI unit. Oxygen (15 liters/min) mixed with room air was given using face mask from 8 second to 35 second during the study. Images were acquired 25 times (scan time per study were 1.6 seconds) using susceptibility contrast EPI (echo planar image) sequence. Difference maps were acquired by early (study 12-18), and late (study 19-25) O2 inhalation image groups minus pre-O2 inhalation image group (study 3-9) with a Z-score of 0.7-1.0 using VB31C program of Magneton Vision. The resulting perfusion images were created by superimposition of difference maps on corresponding T1 weighted anatomic images. On moyamoya patient, similar perfusion images were acquired after Gd-DTPA injection, and compared with O2 inhalation perfusion images. Results ; The author can get the perfusion images of the brain by oxygen inhalation with susceptibility contrast EPI sequence at the volunteers, and the patient of moyomoya disease, acute infarction and meningioma. On moyamoya patient, perfusion images with O2 inhalation are similar with perfusion images by Gd-DTPA injection. Conclusion 1 This study has demonstrated that the susceptibility contrast EPI by oxygen inhalation can be used as the clinically useful perfusion MRI technique

  • PDF

MIRACODE와 FLIP

  • Lorch, Walter T.;Oh, Ik-Sang
    • Journal of Information Management
    • /
    • v.2 no.4
    • /
    • pp.6-8
    • /
    • 1964
  • This first article in a series of descriptions of devices and methods in the field of automated information processing depicts two machines representing a. certain type of documentation systems which use micro-images and coding of documents in an unalterable sequence, namely on 16mm filmrolls.

  • PDF

Clinical Usefulness of MR FLAIR Image in Mild Head Injuries (경증 두부외상 환자에서 MR FLAIR 영상의 임상적 유용성)

  • Kim, Sei-Yoon;Whang, Kum;Kim, Hun-Joo;Lee, Myoung-Sup
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1182-1186
    • /
    • 2001
  • Objectives : MR fluid-attenuated inversion recovery(FLAIR) image uses paired long inversion time and relaxation time that nulls the signal from CSF. With nulling of the CSF long echo time readout could be used to increase T2-weighting, hence improving the conspicuousness of most tissue lesions without the deleterious effects of CSF artifact seen on T2 weighted sequence. We examed the usefulness of FALIR image in the diagnosis of mild head injury. Methods : A total of 38 patients with mild head injury were examined by FLAIR image. We compared those images with CT scan and T1, T2-weighted images. Careful observation of MR images were done by two well-trained neuroradiologists. Each image was compared for conspicuousness and detectability of traumatic lesions might have shown abnormal signal intensities. The Wilcoxon signed ranks test was used for statistical evaluation. Results : The FLAIR image was significantly more sensitive than those of other images(p<0.001). T2 FFE(Fast Field Echo) image was more useful for detection of small petechial hemorrhages. Conclusion : FLAIR image is considered to be more sensitive than those of conventional MR images in the evaluation of mild head injuries.

  • PDF

Comparison of PET image quality using simultaneous PET/MR by attenuation correction with various MR pulse sequences

  • Park, Chan Rok;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.51 no.6
    • /
    • pp.1610-1615
    • /
    • 2019
  • Positron emission tomography (PET)/magnetic resonance (MR) scanning has the advantage of less additional exposure to radiation than does PET/computed tomography (CT). In particular, MR based attenuation correction (MR AC) can greatly affect the image quality of PET and is frequently obtained using various MR sequences. Thus, the purpose of the current study was to quantitatively compare the image quality between MR non-AC (MR NAC) and MR AC in PET images with three MR sequences. Percent image uniformity (PIU), percent contrast recovery (PCR), and percent background variability (PBV) were estimated to evaluate the quality of PET images with MR AC. Based on the results of PIU, 15.2% increase in the average quality was observed for PET images with MR AC than for PET images with MR NAC. In addition, 28.6% and 71.1% improvement in the average results of PCR and PBV respectively, was observed for PET images with MR AC compared with that with MR NAC. Moreover, no significant difference was observed among the average values using three MR sequences. In conclusion, the current study demonstrated that PET with MR AC improved the image quality and can be help diagnosis in all MR sequence cases.

2D-3D Conversion Method Based on Scene Space Reconstruction (장면의 공간 재구성 기법을 이용한 2D-3D 변환 방법)

  • Kim, Myungha;Hong, Hyunki
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.7
    • /
    • pp.1-9
    • /
    • 2014
  • Previous 2D-3D conversion methods to generate 3D stereo images from 2D sequence consist of labor-intensive procedures in their production pipelines. This paper presents an efficient 2D-3D conversion system based on scene structure reconstruction from image sequence. The proposed system reconstructs a scene space and produces 3D stereo images with texture re-projection. Experimental results show that the proposed method can generate precise 3D contents based on scene structure information. By using the proposed reconstruction tool, the stereographer can collaborate efficiently with workers in production pipeline for 3D contents production.

Cerebral Activation Area Following Oxygen Administration using a 3 Tesla Functional MR Imaging (고 자장 기능적 MR 영상을 이용한 뇌 운동 영역에서 산소 주입에 따른 활성화 영역에 관한 연구)

  • Goo, Eun-Hoe;Kweon, Dae-Cheol
    • Journal of the Ergonomics Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.47-53
    • /
    • 2005
  • This study aim to investigate the effects of supply of oxygen enhances cerebral activation through increased activation in the brain and using a 3 Tesla fMRI system. Five volunteers (right handed, average age of 21.3) were selected as subjects for this study. Oxygen supply equipment that provides 30% oxygen at a constant rate of 15L/min was given using face mask. A 3 Tesla fMRI system using the EPI BOLD technique, and three-pulse sequence technique get of the true axial planes scanned brain images. The author can get the perfusion images of the brain by oxygen inhalation with susceptibility contrast EPI sequence at the volunteers. Complex movement consisted of a finger task in which subjects flexed and extended all fingers repeatedly in union, without the fingers touching each other. Both task consisted of 96 phases including 6 activations and rests contents. Post-processing was done on MRDx software program by using cross-correlation method. The result shows that there was an improvement in performance and also increased activation in several areas in the oxygen method. These finding demonstrates that while performing cognitive tasks, oxygen administration was due to increase of cerebral activation.