• 제목/요약/키워드: separate storage

검색결과 140건 처리시간 0.024초

이온크로마토그래피를 활용한 무기산류 정도관리 방법 연구 (A Study on Quality Control of Inorganic Acids using Ion Chromatograph)

  • 박해동;박승현;정기효
    • 한국산업보건학회지
    • /
    • 제31권1호
    • /
    • pp.22-30
    • /
    • 2021
  • Objectives: The objectives of this study were to develop a quality control protocol of inorganic acids using ion chromatograph and to evaluate analytical proficiency of the legally designated agencies. Methods: This study prepared inorganic acid samples by injecting three anion certified solutions (chloride, nitrate, and sulfate) on the quartz filters. To investigate the storage stability and concentration consistency of the samples, 240 samples for each anion were tested at weeks 0, 2, 4, 8, 12, and 16 while storing at 4℃ and 25℃. To evaluate analytical proficiency, two separate testings were administrated for six skilled analysts and 46 analysts affiliated with legally designated agencies. Results: Average recoveries of the three ions after 16 weeks of storage were fairly high (over 95%). In addition, average recoveries (chloride = 97%, nitrate = 96%, and sulfate = 103%) after 16 weeks of storage at low temperate were relatively higher than those (94%, 93%, and 98%) at room temperature. The coefficients of variation (CV) for the three ions were less than 5% except for the sulfate sample at 5.56 ㎍ (CV = 12.4%). The average ratios of the concentration values analyzed by the legally designated agencies to the injected concentrations were close to 1. However, their CVs were relatively greater (chloride ≤ 49%, nitrate ≤ 14%, and sulfate ≤ 28%), which implies a need for quality control. Conclusions: The quality control protocol used in this study for the three inorganic acids can be utilized in the quality control for ion chromatography.

멸균품의 유효기간에 관한 연구 - 포장재와 보관환경 중심으로 - (A Study for Safe Storage Time for In-house Sterilized Products in a Korean Hospital)

  • 윤계숙;김정희;양신해;채지연;이영미;조경숙
    • 한국의료질향상학회지
    • /
    • 제5권2호
    • /
    • pp.258-276
    • /
    • 1998
  • This study was conducted to justify the "prescribed shelf life" currently used in Samsung Medical Center and give recommendations based on scientific data to adopt for safe and cost-effective storage times for sterile goods Since the early 1970's, predetermined expiration dating policy has been used in Korea on all in-house sterilized products like any other countries; six months for the supplies wrapped in polyethylene peel pouches and two weeks for the rest. Recently, however, the studies suggest that current standards for preserving the sterility can be changing. It looks like we unnecessarily have too-short expiration date of sterilized supplies, that is far from being cost effective. Certainly, this research is an exciting project, especially in Korea, and will be leading and contributing to the paradigm shift of the conservative concept of shelf life for sterile supplies in Korean healthcare facilities. The major goal of this study was placed on the measurement of the recontamination time in packs wrapped in all kinds of wrapping materials used in S.M.C and stored in various conditions for periods ranging from three months to six months, and then develop a practical standard of "shelf life" based on the analyzed data. Objectives: To measure and compare the recontamination time of sterile packs among wrapppers and storage conditions, and develop a practical standard for the shelf life and storage conditions of sterile products. Samples and Method: The sterile integrity was investigated of the total 1,440 sterile sample packs containing gauze strip($1.5cm{\times}0.5cm$) we prepared and wrapped in nine wrapping materials (randomized reprocessed linens, linens reprocessed 99 times, linens reprocessed 120 times, new kraft paper, used kraft paper, new nonwoven fabrics, 6-time reprocessed nonwoven fabrics, new polyethylene peel pouches, used polyethylene peel pouches), and stored in four locations(closed cabinet of one of the typical wards, open shelf of one of ICUs, open shelf of separate storage room in ER, open shelf in OR), for three to six months, respectively in 1998. Each type of packs were opened weekly and the gauze strips inoculated into Brewer's thioglycollate broth at $35^{\circ}C$ for seven days. Results: There was no growth found for any types of the pack and storage conditions studied. Discussion: This study was conducted in an attempt to identify the possibility of extending the current shelf life for sterile goods we use in a sense of cost effectiveness. The findings suggest that we could extend our expiration dates, that means we can save a lot of materials and personnel time meeded for resterilizing, outdating, recleaning, wrapping, and reshelving. Then it will initiate a great reform in the field of healthcare in Korea, and now we are looking forward to this valuable revolution. We are going to continue this study and take all steps need to apply this new concept to our practice, and then trying to extend to other hospitals.

  • PDF

전자 코를 이용한 한우 등심육의 냉장저장 중 향기 패턴 분석 (Aroma Pattern Analysis of Hanwoo Beef (M. longissimus) using Electronic Nose during Refrigerated Storage)

  • 이성기;김주용;김용선
    • 한국축산식품학회지
    • /
    • 제24권3호
    • /
    • pp.260-265
    • /
    • 2004
  • 본 연구는 전자 코 시스템을 이용하여 센서의 감응도, 주성분 분석, 판별분석을 통해 한우육의 향기 패턴을 구명하고, 이를 pH 및 TBARS 값과 비교함으로써 쇠고기의 신속한 향기 평가방법의 가능성을 모색하기 위해 실시하였다. 시료는 도축 후 24시간이 경과한 쇠고기의 등심을 5$\pm$1$^{\circ}C$에서 7일간 저장하면서 실험에 사용하였다. 저장기간이 증가함에 따라 SY/G, SY/AA, SY/Gh, SY/gCTl, SY/gCT 센서의 감응도(dR/R0) 값은 감소하였으나, SY/LG, T30/1, P10/1, P10/2, P40/1, T70/2, PA2 센서의 dR/R0 값은 증가하였다. 저장 1일과 3일째에서는 dR/R0 값이 SY/AA#, T70/2 센서에서만 유의적인 차이를 보였으나(p<0.05), 저장 7일째에서 저장1일과 비교하였을 때 12개의 센서가 모두 유의적인 차이를 보였다(p<0.05). 감응도의 결과를 주성분 분석으로 mapping 하였을 때 저장 1일에 오른쪽 중간, 3일에 오른쪽 하단, 7일에 왼쪽에 길게 퍼져 군락이 형성되었다. 다시 판별분석으로 mapping을 하면 동일 저장기간내 군락이 집중되고, 저장기간별 군락군이 분산되어 뚜렷하게 구별되었다. 저장기간동안 육의 pH와 TBARS는 모두 어떤 항목과도 상관성을 보이지 않았으나, 모든 센서의 값이 각각 정 또는 역의 높은상관성을 가지고 있었다(p<0.001).

팽이버섯의 저장기간 및 품종별 자실체내의 당 함량 변화 (Changes of saccharide content in fruitbody composition of Flammulina velutipes during storage)

  • 전창성;윤형식;임훈태;공원식;이강효;성기호;조재한
    • 한국버섯학회지
    • /
    • 제9권3호
    • /
    • pp.123-131
    • /
    • 2011
  • 최근 수요가 많은 식용버섯 중 팽이버섯을 대상으로 저장기간 중에 발생하는 자실체 내의 당 종류 및 함량변화를 검토하고자 시험을 수행하였다. 팽이버섯 자실체에는 단당류로는 xylose 및 glucose, ribose, 이당류의 당은 lactose 및 trehalose, 당알코홀류는 glycerol 및 mannitol, myoinositol, sorbitol 등이 확인되었다. 팽이버섯에 가장 많은 것은 단당류인 xylose로 백색계열은 47.68mg/g, 갈색계열은 63.28mg/g로 갈색계열의 함량이 높으며, 품종에 따라 약간의 차이를 보였다. 저장기간에 따른 당 함량은 단당류 및 이당류, 당알코올 모두 저장 시간이 증가하면서 같이 증가하는 추세를 보이고 있으나, trehalose는 감소하였다. 저장온도에 따라서는 큰 차이는 없었으나, lactose는 $4^{\circ}C$ 저장에서 저장기간이 길어질수록 크게 증가하는 것으로 나타났으나, $-1^{\circ}C$ 저장에서는 검출되지 않았다.

하부요로증상/전립선비대증 일차 치료의 최근 경향 (Current Trend of the Primary Treatment in Lower Urinary Tract Symptom / Benign Prostatic Hyperplasia)

  • 정희창
    • Journal of Yeungnam Medical Science
    • /
    • 제26권2호
    • /
    • pp.85-92
    • /
    • 2009
  • Clinical benign prostatic hyperplasia (BPH) is a multifaceted phenomenon that is due to prostatic and bladder influences as well as nonurological causes. It is also important to differentiate between the more common voiding or obstructive symptoms as well as the more bothersome storage or irritative symptoms. Lower urinary tract symptoms (LUTS) and BPH may be two separate conditions with different underlying pathologies. However, they are often treated incorrectly as one entity. Both conditions are very common and they represent chronic conditions of the aging male. They are often associated with a significant reduction in the patients' quality of life. Although these are not new conditions, there have been enormous changes in the methods of assessing and managing the patients with these conditions. This review describes some of the influential studies in this area and the current trends of the primary treatment for LUTS/BPH.

  • PDF

HEC-RAS를 이용한 남한강 수계의 수리모델링에 관한 연구 (Study of Hydraulic Modeling in South Han River by HEC-RAS)

  • 장인수;박기범
    • 한국산업융합학회 논문집
    • /
    • 제8권4호
    • /
    • pp.213-220
    • /
    • 2005
  • The Youngwal 1, Youngwal 2 and Youngchun gaging stations are observed flood flow and low flow during Mar. 2004~Oct. 2004. They are observed water stages and flow velocities for flood and low flow. The observed data are used to derived rating curve and equations. The HEC-RAS model is applied for hydraulic modeling in gauging stations. The model is designed to perform one-dimensional hydraulic calculations for an river improvement plan in a full network of natural and constructed channels, and is comprised of a graphical user interface(GUI), separate hydraulic analysis components, data storage and management capabilities, graphics and reporting facilities.

  • PDF

Practical Methodology of the Integrated Design and Power Control Unit for SHEV with Multiple Power Sources

  • Lee, Seongjun;Kim, Jonghoon
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.353-360
    • /
    • 2016
  • Series hybrid electric vehicles (SHEVs) having multiple power sources such as an engine- generator (EnGen), a battery, and an ultra-capacitor require a power control unit with high power density and reliable control operation. However, manufacturing using separate individual power converters has the disadvantage of low power density and requires a large number of power and signal cable wires. It is also difficult to implement the optimal power distribution and fault management algorithm because of the communication delay between the units. In order to address these concerns, this approach presents a design methodology and a power control algorithm of an integrated power converter for the SHEVs powered by multiple power sources. In this work, the design methodology of the integrated power control unit (IPCU) is firstly elaborately described, and then efficient and reliable power distribution algorithms are proposed. The design works are verified with product-level and vehicle-level performance experiments on a 10-ton SHEV.

국내 종합병원부설 생명공학연구소의 GMP 시설에 대한 실태조사 및 공간구성에 대한 연구 (A Study on the Space Program & Research of GMP in Domestic Institute for Life Science)

  • 이상석;박재승
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제13권1호
    • /
    • pp.7-15
    • /
    • 2007
  • The medicine is used for diagnosis, treatment or prevention of disease and consequently has an important influence upon human life and health. Its effectiveness and safety must be guaranteed. In order to achieve the facility that meets GMP, KFDA has provided standards for quality assurance of the manufacture, examination and tests of medical supplies. The result of this study were as follows : the GMP facilities are divided into work, lab/test and storage spaces, and the systematic corridor. The clean rooms are mainly installed in work and lab/test spaces, and maintain class 10,000 in average. The individual space for the procedures that requires class 100 is not provided as a separate division. Instead, they are performed in the clean bench of the laboratory.

  • PDF

ASIC설계를 위한 하드웨어 할당 및 바인딩 알고리듬 (A Hardware Allocation and Binding Algorithm for ASIC Design)

  • 최지영;인치호;김희석
    • 한국정보처리학회논문지
    • /
    • 제7권4호
    • /
    • pp.1255-1262
    • /
    • 2000
  • This paper proposes a hardware allocation and binding algorithm for ASIC Design. The proposed algorithm works on schedules input graph and simultaneously allocates and binds functional units, interconnections and registers by considering interdependency between operations and storage elements in each control step, in order to share registers and interconnections connected to functional units, as much as possible. Especially, he register allocation is executes the allocation optimal using graph coloring. This paper shows the effectiveness of the algorithm by comparing experiments to determine number of functional unit and register in advance or to separate executing allocation and binding of existing system.

  • PDF

An Experimental Study on Two Parameter Control for Radiant Floor Heating System

  • Cho, Sung-Hwan;Tae, Choon-Seob;Jang, Chel-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.136-147
    • /
    • 1998
  • An experimental facility consisting of two 3$\times$4.4$\times$2.8m rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparison of two different control strategies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study: (ⅰ) conventional on-off control based on feedback from room air temperature (ⅱ) TPSC(two parameter switching control )(ⅲ) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF