• 제목/요약/키워드: sensor-conditioning

Search Result 155, Processing Time 0.026 seconds

Thermal Environment Analysis of a Classroom by CFD Simulation to Determine Optimal Temperature Sensor Position in Ceiling Type Air-Conditioning System (천정형 에어컨 온도센서의 최적 위치 결정을 위한 교실의 CFD 열환경 분석)

  • Li, M.H.;Kim, D.G.;Kum, J.S.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.10 no.4
    • /
    • pp.43-49
    • /
    • 2006
  • Nowadays, the thermal environments of classrooms are usually adjusted by the ceiling type air-conditioning system with a temperature sensor installed on inlet of an air-conditioner. However, it is not clear that the conventional temperature sensor position is proper to satisfy both thermal comport and energy saving in summer especially. Therefore, this study is aimed at finding out the best position of the temperature sensor on the purpose of the comfort thermal environment and energy saving. The different 5 positions for the temperature sensor are supposed in this paper to analyze thermal environment by CFD. From the analysis through the CFD simulations, the best position of the temperature sensor satisfying for both comfort thermal environment and energy saving is obtained.

  • PDF

The Design and Fabrication of Capacitive Humidity Sensor Having Interdigit Electrodes and its Signal Conditional Circuitry (빗살형 전극을 가지는 정전용량형 습도센서와 그 신호처리회로의 설계와 제작)

  • Park, Se-Kwang;Kang, Jeong-Ho;Park, Jin-Su
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.3
    • /
    • pp.144-148
    • /
    • 2001
  • For the purpose of developing capacitive humidity sensor having interdigit electrodes, interdigit electrode was modeled and simulated to obtain capacitance and sensitivity as a function of geometric parameters like the structural gap and thichness. For the development of ASIC, switched capacitor signal conditioning circuits for capacitive humidity sensor were designed and simulated by cadence using 0.25um CMOS process parameters. The signal conditioning circuits are composed of amplifier for voltage gain control, and clock generator for sensor driving and switch control The characteristics of the fabricated sensors are; 1) sensitivity is 9fF/%R.H., 2) temperature coefficient of offset(TCO) is 0.4%R.H./$^{\circ}C$, 3) nonlinearity is 1.2%FS, 4) hysteresis is 1.5%FS in humidity range of 3%R.H. ${\sim}$ 98%R.H.. The response time is 50 seconds in adsorption and 70 seconds in desorption. Fabricated process used in this capacitive humidity sensor having interdigit electrode are just as similar as conventional IC process technology. Therefore this can be easily mass produced with low cost, simple circuit and utilized in many applications for both industrial and environmental measurement and control system, such as monitoring system of environment, automobile, displayer, IC process room, and laboratory etc..

  • PDF

Development and Evaluation of a PMV Sensor for the Control of Indoor Thermal Environment (실내 온열환경 제어를 위한 PMV 센서의 개발 및 적용성 평가연구)

  • 윤동원;강효석;안병욱
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.870-878
    • /
    • 2003
  • The maintenance of thermal equilibrium between the human body and its environment is one of the primary requirements for health, wellbeing and comfort. For the effective control of indoor thermal environment, thermostat or humidistat is used. But, it is not sufficient to control the indoor thermal environment using only one or two parameters as human response for the indoor comfortable environment. So an environmental thermal index is required for the control of indoor thermal environment effectively. In this study, a PMV sensor has been developed which has integrated from various kinds of individual sensors for temperature, humidity, air velocity, radiant temperature. After applying the PMV and PPD equation, it is possible to monitor the indoor thermal environment with the sensor system, which is adopted to the circuit for optimization according to the human response with the metabolic rate and activities. The measurement was carried out to verify the performance of the integrated sensor system in comparison with existing measurement system, the PMV meter. As a result, the possibility of applying the PMV sensor to control the indoor thermal environment simultaneously was examined.

An Evaluation on IR Sensor Based Demand Controlled Ventilation Strategies for Multi-zone in the Apartment House (IR(Infrared) 센서기반 제어방법에 따른 공동주택 멀티 존 환기시스템 평가 연구)

  • Hong, Sung-Min;Yoon, Dong-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.2
    • /
    • pp.174-182
    • /
    • 2012
  • In previous research, most occupant said that they have not operated ventilation system installed in the house, because of increasing of energy consumption and unconcern of ventilation. Therefore, it is necessary to applied the sensor based demand controlled ventilation for the IAQ(Indoor Air Quality) and improvement of energy efficiency in ventilation strategy. The propose of this study is to present a application method of IR(Infrared) sensor for multi-zone DCV(Demand Controlled Ventilation) in the apartment house. It is possible that IR sensor could be used for DCV, because that could detect the occupant and action. IR sensor based DCV strategies are established to evaluate characteristic of application in the apartment house and simulated by Contam program. As a result, they have some week points though, if they would be applied DCV with optimum strategy, it would be useful to improve IAQ, to reduce energy consumption.

Design of Self-Powered Sensor System for Condition Monitoring of Industrial Electric Facilities (산업전기 설비의 상태 감시를 위한 자가 발전 센서 시스템의 설계)

  • Lee, Ki-Chang;Kang, Dong-Sik;Jeon, Jeong-Woo;Hwang, Don-Ha;Lee, Ju-Hun;Hong, Jeong-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.264-266
    • /
    • 2005
  • Recently, on-line diagnosis methods through wired and wireless networks are widely adopted in the diagnosis of industrial Electric Facilities, such as generators, transformers and motors. Also smart sensors which includes sensors, signal conditioning circuits and micro-controller in one board are widely studied in the field of condition monitoring. This paper suggests an self-powered system suitable for condition-monitoring smart sensors, which uses parasitic vibrations of the facilities as energy source. First, vibration-driven noise patterns of the electric facilities are presented. And then, an electromagnetic generator which uses mechanical mass-spring vibration resonance are suggested and designed. Finally energy consumption of the presented smart sensor, which consists of MEMS vibration sensors, signal conditioning circuits, a low-power consumption micro-controller, and a ZIGBEE wireless tranceiver, are presented. The usefulness and limits of the presented electromagnetic generators in the field of electric facility monitoring are also suggested.

  • PDF

Fluid Sensor and Algorithm for Trouble Detection of Solar Thermal System (태양열 시스템 고장진단을 위한 유체센서와 알고리즘)

  • Lee, Won-Chul;Hong, Hiki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.8
    • /
    • pp.351-356
    • /
    • 2014
  • Typical trouble patterns in solar thermal systems include working fluid leakage and freezing other than breakdown of pump. A fluid sensor for measuring electric resistance of fluid was developed and installed at the top of the collector piping in order to check the fault of solar system. Working fluid level in the pipe was determined by measuring electric resistance from a fluid sensor. On the base of this, it was confirmed that the fluid sensor diagnoses leakage of fluid. Electric resistance of propylene glycol aqueous solution was measured in the range of $0{\sim}70^{\circ}C$ and 0~40% of concentration. The response surface analysis was performed by using a central composite design, and the regression equation was derived from the relationship between electric resistance, temperature, and concentration. Through the experiment in a real solar system, we can estimate a concentration of working fluid when a pump is not operating and predict a possibility of freezing. Finally, an effective algorithm for trouble shooting was proposed to operate and maintain the solar system.