• Title/Summary/Keyword: sensor-conditioning

Search Result 155, Processing Time 0.023 seconds

Intelligent Home appliances Power Control using Android and Arduino (안드로이드와 아두이노를 이용한 지능형 가전제품 전력 컨트롤)

  • Park, Sung-hyun;Kim, A-Yong;Kim, Wung-Jun;Bae, Keun-Ho;Yoo, Sang-keun;Jung, Hoe-kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.854-856
    • /
    • 2014
  • Has been released of make it possible to control the using for smart devices of a wide variety home appliances and electronics in smart appliances in accordance with the one person multi devices. In addition, is increasing rapidly for the number of the product on cleaning robot and refrigerator, air conditioning, TV, etc. these devices are using the implement up DLNA system. And at home and abroad for development and has provided with Iot and Alljoyn such systems. But currently using home appliances or electronic devices of there are a lot of the operating system non installed than the installed products. In addition, smart appliances do not use for user than buying existing electronic products a lot more. In addition, more occur for smart appliances of that do not use for the user on smart appliances rather than buying existing electronics. In this paper, Suggested and implemented for system of control such as smart devices to existed home appliance on not have an operating system, Using mobile device for want users to quantify the data to transfer from arduino board.

  • PDF

Air-conditioning and Heating Time Prediction Based on Artificial Neural Network and Its Application in IoT System (냉난방 시간을 예측하는 인공신경망의 구축 및 IoT 시스템에서의 활용)

  • Kim, Jun-soo;Lee, Ju-ik;Kim, Dongho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.347-350
    • /
    • 2018
  • In order for an IoT system to automatically make the house temperature pleasant for the user, the system needs to predict the optimal start-up time of air-conditioner or heater to get to the temperature that the user has set. Predicting the optimal start-up time is important because it prevents extra fee from the unnecessary operation of the air-conditioner and heater. This paper introduces an ANN(Artificial Neural Network) and an IoT system that predicts the cooling and heating time in households using air-conditioner and heater. Many variables such as house structure, house size, and external weather condition affect the cooling and heating. Out of the many variables, measurable variables such as house temperature, house humidity, outdoor temperature, outdoor humidity, wind speed, wind direction, and wind chill was used to create training data for constructing the model. After constructing the ANN model, an IoT system that uses the model was developed. The IoT system comprises of a main system powered by Raspberry Pi 3 and a mobile application powered by Android. The mobile's GPS sensor and an developed feature used to predict user's return.

  • PDF

Indoor Temperature Analysis by Point According to Facility Operation of IoT-based Vertical Smart Farm (IoT 기반 수직형 스마트 팜의 설비운영에 따른 지점별 실내온도분석)

  • Kim, Handon;Jung, Mincheol;Oh, Donggeun;Cho, Hyunsang;Choi, Seun;Jang, Hyounseung;Kim, Jimin
    • Korean Journal of Construction Engineering and Management
    • /
    • v.23 no.1
    • /
    • pp.98-105
    • /
    • 2022
  • It is essential for vertical smart farms that artificially grow crops in an enclosed space to properly utilize air environment facilities to create an appropriate growth environment. However, domestic vertical smart farm companies are creating a growing environment by relying on empirical data rather than systematic methods. Using IoT to create a growing environment based on systematic and precise monitoring can increase crop production yield and maximize profitability. This study aims to construct a monitoring system using IoT and to analyze the cause by demonstrating the imbalance of temperature environment, which is a significant factor in crop cultivation. 1) The horizontal temperature distribution of the multi-layer shelf was measured with different operating methods of LED and air conditioner. As a result, there was a temperature difference of "up to 1.7℃" between the sensors. 2) As a result of measuring the vertical temperature distribution, the temperature difference was "up to 6.3℃". In order to reduce this temperature gap, a strategy for proper arrangement and operation of air conditioning equipment is required.

The Comparison of the Ultra-Violet Radiation of Summer Outdoor Screened by the Landscaping Shade Facilities and Tree (조경용 차양시설과 수목에 의한 하절기 옥외공간의 자외선 차단율 비교)

  • Lee, Chun-Seok;Ryu, Nam-Hyong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.6
    • /
    • pp.20-28
    • /
    • 2013
  • The purpose of this study was to compare the ultra-violet(UV) radiation under the landscaping shade facilities and tree with natural solar UV of the outdoor space at summer middays. The UVA+B and UVB were recorded every minute from the $20^{th}$ of June to the $26^{th}$ of September 2012 at a height of 1.1m above in the four different shading conditions, with fours same measuring system consisting of two couple of analog UVA+B sensor(220~370nm, Genicom's GUVA-T21GH) and UVB sensor(220~320nm, Genicom's GUVA-T21GH) and data acquisition systems(Comfile Tech.'s Moacon). Four different shading conditions were under an wooden shelter($W4.2m{\times}L4.2m{\times}H2.5m$), a polyester membrane structure ($W4.9m{\times}L4.9m{\times}H2.6m$), a Salix koreensis($H11{\times}B30$), and a brick-paved plot without any shading material. Based on the 648 records of 17 sunny days, the time serial difference of natural solar UVA+B and UVB for midday periods were analysed and compared, and statistical analysis about the difference between the four shading conditions was done based on the 2,052 records of daytime period from 10 A.M. to 4 P.M.. The major findings were as follows; 1. The average UVA+B under the wooden shelter, the membrane and the tree were $39{\mu}W/cm^2$(3.4%), $74{\mu}W/cm^2$(6.4%), $87{\mu}W/cm^2$(7.6%) respectively, while the solar UVA+B was $1.148{\mu}W/cm^2$. Which means those facilities and tree screened at least 93% of solar UV+B. 2. The average UVB under the wooden shelter, the membrane and the tree were $12{\mu}W/cm^2$(5.8%), $26{\mu}W/cm^2$(13%), $17{\mu}W/cm^2$(8.2%) respectively, while the solar UVB was $207{\mu}W/cm^2$. The membrane showed the highest level and the wooden shelter lowest. 3. According to the results of time serial analysis, the difference between the three shaded conditions around noon was very small, but the differences of early morning and late afternoon were apparently big. Which seems caused by the matter of the formal and structural characteristics of the shading facilities and tree, not by the shading materials itself. In summary, the performance of the four landscaping shade facilities and tree were very good at screening the solar UV at outdoor of summer middays, but poor at screening the lateral UV during early morning and late afternoon. Therefore, it can be apparently said that the more delicate design of shading facilities and big tree or forest to block the additional lateral UV, the more effective in conditioning the outdoor space reducing the useless or even harmful radiation for human activities.

The Comparison of the Solar Radiation and the Mean Radiant Temperature (MRT) under the Shade of Landscaping Trees in Summertime (하절기 조경용 녹음수 수관 하부의 일사와 평균복사온도 비교)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.42 no.5
    • /
    • pp.22-30
    • /
    • 2014
  • The purpose of this study was to compare the Solar Radiation(SR) and the Mean Radiant Temperature(MRT) under the shades of the three landscaping trees in clear summer daytimes. The trees were Lagerstroemia indica, Quercus palustris and Ulmus parvifolia. The solar radiation, the globe temperature and the air temperature were recorded every minute from the $1^{st}$ of April to the $30^{th}$ of September 2013 at a height of 1.1m above on the four monitoring stations, with four same measuring system consisting of a solar radiation sensor, two resistance temperature detectors(Pt-100), a black brass globe (${\phi}50mm$) and data acquisition systems. At the same time, the sky view photos were taken automatically hourly by three scouting cameras(lens angle: $60^{\circ}$) fixed at each monitoring station. Based on the 258 daily sky view photos and 6,640 records of middays(10 A.M.~2 P.M.) from the $1^{st}$ of June to the $30^{th}$ of August, the time serial differences of SR and MRT under the trees were analysed and compared with those of open sky, The major findings were as follows; 1. The average ratio of sky views screened by the canopies of Quercus palustris, Lagerstroemia indica and Ulmus parvifolia were 99%, 98% and 97%, and the SR were $106W/m^2$, $163W/m^2$ and $202W/m^2$ respectively, while the SR of open sky was $823W/m^2$. Which shows the canopies blocked at least 70% of natural SR. 2. The average MRT under the canopies of Quercus palustris, Lagerstroemia indica and Ulmus parvifolia were $30.34^{\circ}C$, $33.34^{\circ}C$ and $34.77^{\circ}C$ respectively, while that of open sky was $46.0^{\circ}C$. Therefore, it can be said that the tree canopies can reduce the MRT around $10{\sim}16^{\circ}C$. 3. The regression test showed significant linear relationship between the SR and MRT. In summary, the performances of the landscaping shade trees were very good at screening the SR and reducing the MRT at the outdoor of summer middays. Therefore, it can be apparently said that the more shade trees or forest at the outdoor, the more effective in conditioning the outdoor space reducing the MRT and the useless SR for human activities in summertime.