• Title/Summary/Keyword: sensor scanning

Search Result 455, Processing Time 0.035 seconds

NO Gas Sensing Characteristics of Single-Walled Carbon Nanotubes and Heating Effect (단층 탄소나노튜브의 일산화질소 가스에 대한 감응특성과 열처리 효과)

  • Kim, Min-Ju;Yun, Kwang-Hyun;Huh, Jeung-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.292-297
    • /
    • 2004
  • Carbon nanotubes (CNT) were synthesized by arc-discharge method. To fabricate CNT sensor, CNT powder was dispersed in ${\alpha}$-Terpinol($C_{10}H_{17}OH$) solution. The CNT tilms were fabricated by screen printing method on the interdigitated Pt/Pd alloy electrode. The microstructure of CNT film was observed by scanning electron microscopy (SEM) and transmission electron microscopy (TEM). In order to investigate the gas sensing characteristics of the film, the CNT film was experimented to measure NO response and recovery time. The CNT sensor with a heater was compared to that without a heater. And this sensor shows better reproductibility and faster recovery time than another CNT sensors. We suggest the possibility to utilize a CNT as new sensing materials for environmental monitoring.

Image Restoration in Digital Radiography Using Dual Sensor Wiener Filer (이중센서 위너필터를 이용한 디지탈 라디오 그라피 영상 복원)

  • Lee, Tae-Soo;Park, Kwang-Suk;Min, Byoumg-Goo;Lim, Jeong-Gee;Han, Man-Chung
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.3
    • /
    • pp.293-302
    • /
    • 1989
  • A Dual Sensor Wiener Filter technique was used to improve the image quality of the scanning type digital radiographic system (resolution and SNR). In this method, two images were acquried simultaneously using two sensors with high and low resolution and SNR values. Using the cross Power spectrum between dual sensor outputs of the same chest radiographic image. we design a new type of Wiener Filter and implement it with fast algorithm. We compared the performance of this new dual sensor filter with conventional single sensor filters (Wiener Filter and Parametric Projec- tion Filter) . In simulation studies, it is shown that this new method has SNR improvement of 1-3 dB better than conventional filters.

  • PDF

A Study on Automatic Seam Tracking of Arc Welding Using an Laser Displacement Sensor (레이져 변위센서를 이용한 용접선 자동추적에 관한 연구(2))

  • 양상민;조택동;전진환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.729-733
    • /
    • 1997
  • Due to the variety of disturbance, it is not ease to accomplish the in-process detection of weld line with non-contact sensor. To get around this difficulties problem develop an automatic seam tracking weld system, the reliable signal processing algorithm has been recommanded. In this research, laser displacement sensor is applied as a seam finder in the automatic tracking system. The sensor is controlled by a dc servo motor which is mounted at X-Y moving table. X-Y moving table manipulated by an ac servo motor controls the position and velocity of the welding torch. First, X-Y table moves to Y-axis to search the welding joint feature before starting the welding, and welding joint is from the scanning data and weighting factor for each other. Second, weld line is determined using proposed signal processing algorithm during welding process. Form the experimental results, we could see the possibility that laser displacement sensor with procesed algorithm can be used as a seam finder in welding process under the severe noise (spatter,arc light etc.) condition

  • PDF

The influence of nonlinear damping on the response of a piezoelectric cantilever sensor in a symmetric or asymmetric configuration

  • Habib, Giuseppe;Fainshtein, Emanuel;Wolf, Kai-Dietrich;Gottlieb, Oded
    • Smart Structures and Systems
    • /
    • v.30 no.3
    • /
    • pp.239-243
    • /
    • 2022
  • We investigate the influence of nonlinear viscoelastic damping on the response of a cantilever sensor covered by piezoelectric layers in a symmetric or asymmetric configuration. We formulate an initial-boundary-value problem which consistently incorporates both geometric and material nonlinearities including the effect of viscoelastic damping which cannot be ignored for micro- and nano-mechanical sensor operation in a vacuum environment. We employ an asymptotic multiple-scales methodology to yield the system nonlinear frequency response near its primary resonance and employ a model-based estimation procedure to deduce the system damping backone curve from controlled experiments in vacuum. We discuss the effect of nonlinear damping on sensor applications for scanning probe microscopy.

Development and Evaluation of Non-Hydrous Skin Analogue Liquid Crystal using Thermo-Sensitivity Smart Sensor

  • Yoo, Kwang-Ho;Hong, Jae-Hwa;Eun, So-Hee;Jeong, Tae-Hwa;Jeong, Kwan-Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.367-374
    • /
    • 2014
  • In this study, skin permeation enhancement was confirmed by designing it to have a structure and composition similarity to the intercellular lipids that improve miscibility with skin by cross-linked lipids poloxamer. The cross-linked lipids poloxamer was synthesized and analyzed by 1H NMR that structure dose had conjugated pluronic with ceramide3. Active component is released by modification of liquid crystal structure because PPO part, large-scale molecule block of pluronic, has hydrophobic nature at skin temperature of $35^{\circ}C$. Conjugated pluronic with ceramide3 was synthesized using Pluronic F127 and p-NPC (4-nitrophenyl chloroformate) at room temperature yielded 89%. Pluronic(Ceramide 3-conjugated Pluronic) was synthesized by reaction of p-NP-Pluronic with Ceramide3 and DMAP. The yield was 51%. This cross-linked lipids poloxamer was blended and dissolved at isotropic state with skin surface lipids, phospholipid, ceramide, cholesterol and anhydrous additive solvent. Next step was preceded by ${\alpha}$-Transition at low temperature for making the structure of Meso-Phase Lamella, and non-hydrous skin analogue liquid crystal using thermo-sensitivity smart sensor, lamellar liquid crystal structure through aging time. For confirmation of conjugation thermo-sensitivity smart sensor and non-hydrous skin analogue liquid crystal, structural observation and stability test were performed using XRD(Xray Diffraction), DSC(Differential Scanning Calorimetry), PM (Polarized Microscope) And C-SEM (Cryo-Scanning Electron Microscope). Thermo-sensitivity observation by Franz cell revealed that synthesized smart sensor shown skin permeation effect over 75% than normal liquid crystal. Furthermore, normal non-hydrous skin analogue liquid crystal that not applied smart sensor shown similar results below $35^{\circ}C$ of skin temperature, but its effects has increased more than 30% above $35^{\circ}C$.

Measurement of effective cure shrinkage of EMC using dielectric sensor and FBG sensor (유전 센서 및 광섬유 센서를 이용한 EMC 유효 경화 수축 측정)

  • Baek, Jeong-hyeon;Park, Dong-woon;Kim, Hak-sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.4
    • /
    • pp.83-87
    • /
    • 2022
  • Recently, as the thickness of the semiconductor package becomes thinner, warpage has become a major issue. Since the warpage is caused by differences in material properties between package components, it is essential to precisely evaluate the material properties of the EMC(Epoxy molding compound), one of the main components, to predict the warpage accurately. Especially, the cure shrinkage of the EMC is generated during the curing process, and among them, the effective cure shrinkage that occurs after the gelation point is a key factor in warpage. In this study, the gelation point of the EMC was defined from the dissipation factor measured using the dielectric sensor during the curing process similar with actual semiconductor package. In addition, DSC (Differential scanning calorimetry) test and rheometer test were conducted to analyze the dielectrometry measurement. As a result, the dielectrometry was verified to be an effective method for monitoring the curing status of the EMC. Simultaneously, the strain transition of the EMC during the curing process was measured using the FBG (Fiber Bragg grating) sensor. From these results, the effective cure shrinkage of the EMC during the curing process was measured.

The realization of 3D Display by using 2D sensor

  • Lee, Kyu-Tae;Um, Kee-Tae;Kim, Sang-Jo;Chae, Kyung-Pil
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.765-768
    • /
    • 2008
  • To make 3D camera system, we check the possibility of advanced range camera module based on measuring the time delay of modulated infrared light, using a single detector chip fabricated on standard CMOS process. To depth information, electronic shutter and interlaced scanning method of 2D sensor is needed. Especially, we design "lens system, illumination unit" and review simulation result.

  • PDF

Development of Small-sized SQUID and Direct-coupled Electronics for High-$T_c$ Scanning SQUID Microscope (소형 SQUID, 직접 되먹임 방식 전자회로, 고온초전도 SQUID 주사현미경의 개량)

  • Baek, B.;Lee, S. M;Yun, J. H.;Khim, Z. G.
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.78-82
    • /
    • 2001
  • The spatial resolution of $high-T_{c}$ scanning SQUID microscope is limited by the washer size of SQUID and the gap distance between SQUID sensor and the sample. In this work, we tried to improve the spatial resolution of scanning SQUID microscope by reducing the size of SQUID sensor fabricated with $YBa_2$$Cu_3$$O_{7}$ thin film. Outer dimensions of the SQUiDs we tested are 24 $\mu\textrm{m}$ $\times$ $ 28\mu\textrm{m}$, $12 \mu\textrm{m}$ $\times$ $16\mu\textrm{m}$, $12\mu\textrm{m}$ x $12\mu\textrm{m}$, $10 \mu\textrm{m}$ $\times$ $10 \mu\textrm{m}$ each. To operate them in the flux-locked loop scheme, we used a direct-coupled electronics instead of using conventional electronics involving a modulation scheme. Since the direct-coupled feedback scheme does not require modulation current adjustment that poses as a practical difficulty in the SQUID operation in modulation-scheme, the direct feedback operation is rather simpler than the conventional modulation method. The resulting noise features were dominated by the noise of preamp in FLL electronics except that of the largest SQUID. The noise levels of SQUIDs are expected below 1$\times$$10^{-5}$ $\Phi_{0}$H $z^{1}$2/ (at 300 Hz), that is a typical noise level for SQUID made of $YBa_2$C $u_3$$O_{7}$ thin film. The data acquisition and motion-controlling parts were also improved, resulting in faster data acquisition rate and less vibration of the system.m.

  • PDF

A Study on Graylevel Image Scanning System Realization Using CIS (CIS를 이용한 그레이레벨 이미지 스케닝시스템 구현에 관한 연구)

  • 김영빈;김윤호;류광렬
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.3
    • /
    • pp.470-474
    • /
    • 2002
  • The graylevel image scanning system realization and design using CIS(Contact image Scanning)be amenable to recognize a papers, OMR and OCR sheet is proposed. The design technique is used CIS scanning sensor in fixing step motor and is optimized with DSP processor for inage processing, and transfer input image data par line in feeding a step unit to PC on the USB interfacer. This system is portable ad A4 size scanning. and keeps image scan processing speed 300mm/sec. The recognition percentage has 98% on the OCR and bar codes.

A Study on Graylevel Image Scanning System Realization Using CIS (CIS를 이용한 그레이레벨 이미지 스케닝시스템 구현에 관한 연구)

  • 김영빈;김윤호;류광렬
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.581-584
    • /
    • 2002
  • The graylevel image scanning system realization and design using CIS(Contact Image Scanning)be amenable to recognize a papers, OMR and OCR sheet is proposed. The design technique is used CIS scanning sensor in fixing step motor and is optimized with DSP processor for image processing., and transfer input image data par line in feeding a step unit to PC on the USB interfacer. This system is portable and A4 size scanning and keeps image scan processing speed 300mm/sec The recognition percentage has 98% on the OCR and bar codes.

  • PDF