• 제목/요약/키워드: sensor cooling

검색결과 146건 처리시간 0.023초

차량용 연료전지 스택의 절연열화 진단을 위한 원통형 정전용량-전기전도도 센서개발 (Development of Cylindrical Capacitive-Conductive Sensor to Evaluate Insulating Degradation for FCEV Stack)

  • 김재훈;김주한;김윤형;최강월;한상옥;용기중
    • 전기학회논문지P
    • /
    • 제59권3호
    • /
    • pp.317-324
    • /
    • 2010
  • It was used as measuring system to diagnose insulating condition, by which was kept a insulating resistance of inner stack and at the same time was cooled electrochemical heat of reaction of FCEV(fuel cell electric vehicle) stack that used a compressed hydrogen gas reacting with oxygen in accordance with variation on thermal degradation of nonconductive heat transfer fluid. Consequently it was developed a cylindrical multi-terminal capacitive-conductive sensor that could be attached to the internal surface of cooling system pipe to evaluate capacitance and conductivity of heat transfer fluid.

기준신호 보상회로를 이용한 더블 샘플링 방식의 비냉각형 볼로미터 검출회로 설계에 관한 연구 (A Study on Double Sampling Design of CMOS ROIC for Uncooled Bolometer Infrared Sensor using Reference Signal Compensation Circuit)

  • 배영석;정은식;오주현;성만영
    • 한국전기전자재료학회논문지
    • /
    • 제23권2호
    • /
    • pp.89-92
    • /
    • 2010
  • A bolometer sensor used in an infrared thermal imaging system has many advantages on the process because it does not need a separate cooling system and its manufacturing is easy. However the sensitivity of the bolometer is low and the fixed pattern noise(FPN) is large, because the bolometer sensor is made by micro electro mechanical systems (MEMS). These problems can be fixed-by using the high performance readout integrated circuit(ROIC) with noise reduction techniques. In this paper, we propose differential delta sampling circuit to remove the mismatch noise of ROIC itself, the FPN of the bolometer. And for reduction of FPN noise, the reference signal compensation circuit which compensate the reference signal by using on-resistance of MOS transistor was proposed.

태양광모듈 냉각장치를 이용한 태양광발전장치 발전효율 향상을 위한 연구방안 (Research Plan to improve Power Generation Efficiency of Photovoltaic Units using Photovoltaic Module Cooling System)

  • 윤용호
    • 한국인터넷방송통신학회논문지
    • /
    • 제20권1호
    • /
    • pp.199-204
    • /
    • 2020
  • 국내에서 사용 중인 실리콘 태양전지판의 경우 제작 사양이 -0.5에서 0.05℃ 한계에서 최대출력을 낼 수 있도록 설계되어있어 온도 1℃ 상승 시 0.45~0.55%의 출력이 감소한다. 결과적으로 태양광발전은 태양전지(CELL)의 특성상 태양광모듈의 표면 온도상승에 따라 출력이 떨어지게 된다. 출력 저하는 태양광발전의 효율을 떨어뜨리며 효율이 떨어지면 최종적으로 태양광발전의 발전량에 따른 전력판매 수익이 감소하는 결과를 낳는다. 따라서 본 논문에서는 온도검출 센서를 통해 설정된 온도 이상으로 식별 시 태양광모듈 하부(또는 주변)에 냉각 공기를 분사시키는 방식을 연구방안으로 제안한다. 추가로 손실된 태양에너지를 활용하여 발전량을 증가시키며 냉각 공기를 통한 냉각기능을 적용함으로써 발전량을 더욱 증대시킬 수 있도록 하였다.

항공기 ECS 냉각공기 시험장비 설계 및 성능 시험 (Design and Performance Test of Cooling-Air Test Equipment for the Environmental Control System in Aircraft)

  • 소재욱;김진성;김재우;김진복
    • 한국항공우주학회지
    • /
    • 제49권2호
    • /
    • pp.147-154
    • /
    • 2021
  • 본 논문에서는 고정익 항공기 환경제어장치(Environmental Control System) 운용 시 발생될 수 있는 냉각공기의 급격한 온도변화가 항공전자장비에 미치는 영향성을 알아보기 위한 시험장비 구성 및 설계안을 제시한다. ECS 시동 시, 항공기 ECS에서 공급되는 공기의 온도는 초당 5.0℃로 높아질 수 있다. 항공전자장비 개발 시 ECS에서 냉각공기를 제공받는 항공전자장비의 운용성 확보를 위하여, 냉각공기 특성 시험환경을 구현할 수 있는 시험장비가 필요하다. 시험장비 설계 시 열/유동해석을 수행하여 냉각공기의 급격한 온도변화율의 가능성을 확인하였고, 실제 탑재되는 항공전자장비를 적용하여 구현된 시험장비의 성능을 확인하였다.

미소가속도계 센서의 제조공정에서 잔류응력 해석 (Analysis of Residual Stresses at Manufacturing Precesses for Microaccelerometer Sensors)

  • 김옥삼
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권3호
    • /
    • pp.631-635
    • /
    • 2001
  • The major problems associated with the manufacturing processes of the microaccelerometer based on the tunneling current concept is the residual stress. This paper deals with finite element analysis of residual stress causing pop up phenomenon which are induced in micromachining processes for a microaccelerometers sensor using silicon on insulator(SOI) wafer. After heating the tunnel gap up to $100^{\circ}C$and get it through cooling process and the additional beam up to $80^{\circ}C$get it through the cooling process. We learn the residual stress of each shape and compare the results with each other, after heating the tunnel gap up to $400^{\circ}Cduring$ the Pt deposition process. The equivalent stresses produced during the heating process of focused ion beam(FIB) cut was also to be about $0.02~0.25Pa/^{\circ}C$and cooling process the gradient of residual stresses of about $8.4\{times}10^2Pa/{\mu}m$ still at cantilever beam and connected part of paddle. We want to seek after the real cause of this pop up phenomenon and diminish this by change manufacturing processes of microaccelerometer sensors.

  • PDF

삽입되어진 광섬유 센서를 이용한 일방향 적층 복합재료의 열적 거동 연구 (Study on Thermal Behavior of Unidirectional Composite Materials using Embedded Optical Fiber Sensors)

  • 김승택;전흥재;최흥섭
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 1999년도 추계학술발표대회 논문집
    • /
    • pp.251-257
    • /
    • 1999
  • Smart structure that contains sensors, which are either embedded in a composite material or attached to a structure, is currently receiving considerable attention. Fiber Bragg grating sensor, one of the optical fiber sensors, has been widely used to sense strain and temperature for smart structures since both parameters change the resonant frequency of the grating. In this paper, according to the various heating and cooling conditions the thermal behavior of unidirectional composite material was monitored by embedding the fiber Bragg grating sensors in the longitudinal and transverse directions of unidirectional composites. The thermal behavior of unidirectional composite material was monitored for various heating and cooling rates and applied pressure. It was found that the thermal behavior was unaffected by pressure variations and heating and cooling rates applied to the composites. The thermal strains were measured by considering the shift in Bragg wavelength that was generated by the thermal expansion of composite specimen. The longitudinal and transverse C.T.E.'s were also obtained from the corresponding temperature-thermal strain curves.

  • PDF

Performance and Reliability Characteristics of the Free Piston Free Displacer Stirling Cryocooler

  • Park, Seong-Je;Hong, Yong-Ju;Kim, Hyo-Bong;Koh, Deuk-Yong;Kim, Yang-Hoon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권2호
    • /
    • pp.46-51
    • /
    • 2004
  • This paper presents the results of a series of performance and reliability tests for the Stirling cryocooler. Infrared sensor systems incorporating cryocoolers are required to be qualified to the appropriate specification for the performance and reliability. FPFD Stirling cryocooler is currently under development for cooling infrared detector. Manufactured Stirling cryocooler delivers approximately 0.9W cooling at 80K for 30W∼40W of input power. It takes approximately 2 minutes to cool down to 80K at the ambient temperature of 23$^{\circ}C$. Performance characteristics for the vibration, acoustic noise, EMI and leak rate of the Stirling cryocooler are evaluated. We performed low and high temperature keeping test from -32$^{\circ}C$ to +52$^{\circ}C$ and operating test at high and low temperature cyclic range with acceptance tests performed at scheduled intervals. Cooling capacity is determined as a function of the temperatures at the compressor, hot end and cold tip at the expander. Finally, we describe the experimental facility for the MTTF evaluation and some typical results of the Stirling cryocooler.

냉각된 원전 2차계통수의 온도측정을 위한 비접촉식 광섬유 온도센서의 개발 (Development of a Fiber-optic Noncontact Temperature Sensor for Measuring the Temperature of Cooled Secondary Water in a Nuclear Power Plant)

  • 유욱재;이봉수;박병기;조영호
    • 한국산학기술학회논문지
    • /
    • 제11권5호
    • /
    • pp.1730-1734
    • /
    • 2010
  • 원전 2차계통수의 pH를 예측을 위해서는 샘플을 채취, 냉각시킨 후 pH를 측정하게 되는데 이 때 샘플의 온도는 pH를 변화시키는 중요한 요인이 된다. 본 연구에서는 할로겐화 은 광섬유를 이용하여 비접촉식 온도센서를 개발하였고, 열전쌍열을 이용하여 열원으로부터 방출되는 적외선을 측정하였다. 열원과 광섬유 끝단 사이의 거리 및 각도 변화에 따른 광섬유 온도센서의 출력신호를 분석하였으며, 광섬유 온도센서로 측정한 온도범위는 $25{\sim}60^{\circ}C$이다. 본 연구결과를 기초로 원전 2차계통수 pH 샘플의 온도를 측정하기 위해 할로겐화 은 광섬유를 이용한 비접촉식 온도센서의 개발이 가능할 것으로 기대된다.

DEVELOPMENT OF IMMERSION TYPE MOLTER STREEL LEVELMETER

  • Morii, Michio;Azuma, Makoto;Kobayashi, Kazuo;Tezuka, Masao
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1316-1321
    • /
    • 1990
  • Molten steel level information of ladle is very important for process control in steelmaking process. At secondary refining process, measuring lance and snokel have to keep constant thier depth from molten steel surfaces. But, there is much slag on the molten steel surface. Besides, not only the thickness of slag is varied with refining condition, but also molten steel level is largely affected by firebrick errosion. Then, optical measuring method and/or by human eyes cannot detect true molten steel surface, but slag surface. This slag thickness is 300mm at maximum, then huge diameter eddy current sensor will be needed if that type sensor is applied. In addition to, cooling system is necessary because the molten steel and slag temperature is high. This is not practically. To solve this problem, immersion type levelmeter is developed. This sensor is made up from primary and secondary cylindrical coils. High frequency current is applied to primary coil. Electro-motive force from secondary coil is measured, which is varied with molten steel level. This complete set is installed within stainless steel long capsule and attached to top of lance. This sensor is immersed into molten steel bath of ladle or tundish with protection of expendable paper sleeve.

  • PDF

스터링 극저온 냉동기의 운전주파수 의존성에 관한 연구 (Study of the Dependency on Operating Frequency of the Stirling Cryocooler)

  • 홍용주;박성제;고득용;김효봉;김양훈;김종학
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.63-66
    • /
    • 2002
  • A free piston and free displacer (FPFD) Stilting cryocooler for the cooling infrared and cryo-sensor is currently under development at Korea Institute of Machinery & Materials. In this study, the dynamic characteristics of the displacer in the expansion space of the Stirling cooler was investigated by experiment. The experimental results show that the Stirling cryocooler has maximum cooling capacity at the certain relation between operating frequency and natural frequency of the displacer and the operating frequency of the Stirling crycooler should be determined by natural frequency of the linear compressor and displacer.

  • PDF