• 제목/요약/키워드: sensitive measurement

검색결과 841건 처리시간 0.028초

삼면반사체를 이용한 6자유도 미소 변위 측정 (Measurement of Fine 6-DOF Displacement using a 3-facet Mirror)

  • 박원식;조형석;변용규;박노열
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.50-50
    • /
    • 2000
  • In this paper, a new measuring system is :proposed which can measure the fine 6-DOF displacement of rigid bodies. Its measurement principle is based on detection of laser beam reflected from a specially fabricated mirror that looks like a triangular pyramid having an equilateral cross-sectional shape. The mirror has three lateral reflective surfaces inclined 45$^{\circ}$ to its bottom surface. We call this mirror 3-facet mirror. The 3-facet mirror is mounted on the object whose 6-DOF displacement is to be measured. The measurement is operated by a laser-based optical system composed of a 3-facet mirror, a laser source, three position-sensitive detectors(PSD). In the sensor system, three PSDs are located at three corner points of a triangular formation, which is an equilateral triangular formation tying parallel to the reference plane. The sensitive areas of three PSDs are oriented toward the center point of the triangular formation. The object whose 6-DOF displacement is to be measured is situated at the center with the 3-facet mirror on its top surface. A laser beam is emitted from the laser source located at the upright position and vertically incident on the top of the 3-fatcet mirror. Since each reflective facet faces toward each PSD, the laser beam is reflected at the 3-facet mirror and splits into three sub-beams, each of which is reflected from the three facets and finally arrives at three PSDs, respectively. Since each PSD is a 2-dimensional sensor, we can acquire the information on the 6-DOF displacement of the 3-facet mirror. From this principle, we can get 6-DOF displacement of any object simply by mounting the 3-facet mirror on the object. In this paper, we model the relationship between the 6-DOF displacement of the object and the outputs of three PSDs. And, a series of simulations are performed to demonstrate the effectiveness of the proposed method. The simulation results show that the proposed sensing system can be an effective means of obtaining 3-dimensional position and orientation of arbitrary objects.

  • PDF

PSD를 이용한 플라스틱 박막 필름의 경사 각도 측정 시스템 개발 (Development of Tilt angle measurement system of plastic thin-film using Position Sensitive Device)

  • 김기승;박윤창
    • 한국산학기술학회논문지
    • /
    • 제22권2호
    • /
    • pp.134-138
    • /
    • 2021
  • 스마트폰 등에서 사용되는 고성능 디스플레이에는 다양한 종류의 정밀한 플라스틱 박막 필름(Plastic Thin Film)이 사용되고 있다. 롤투롤(Roll-To-Roll) 공정으로 제조되는 플라스틱 박막 필름은 생산 공정 중에 실시간으로 필름의 두께가 계측되고, 정확하게 관리되어야 한다. 필름 제조 과정에서 필름에 장력이 작용하면서 주름이 발생되고, 이러한 주름 발생은 필름의 두께 방향과 두께 측정기의 광축이 서로 경사지게 한다. 결국 두께 측정기는 필름의 수직 두께가 아닌 경사진 두께를 측정하게 됨으로써 실제 두께보다 더 큰 값으로 측정하게 된다. 본 연구에서는, 플라스틱 필름의 경사로 인하여 발생하게 되는 두께 측정기에서의 계측값 오차를 보정하기 위하여, 필름의 경사 각도를 계측하는 연구가 진행되었다. 플라스틱 필름에 슬릿 빔 레이저를 조사하고, 필름에서 반사되는 슬릿 빔 레이저가 PSD(Position Sensitive Device)에 맺히는 광학 시스템을 구성하였으며, 실험을 통하여 필름의 경사 각도와 PSD 출력값의 관계를 1차 방정식 형태로 구하였다. 이를 이용하여 필름의 경사 각도를 측정하는 장치가 구축되었으며, 250KHz의 속도로 경사 각도의 측정이 가능하였다.

Study on a Measurement of Disclosure Risk of Microdata by Similarity

  • Cho, Hyeon-Kwan;Kwon, Dae-Hong;Lee, Suk-Hoon
    • 응용통계연구
    • /
    • 제25권5호
    • /
    • pp.743-755
    • /
    • 2012
  • Researchers using various of statistical data want to obtain microdata for a detailed analysis. Institutes need to provide microdata after masking processes for sensitive data. Many researchers have used the proportion of unique identity for the measurement of disclosure risk. We proposed a new measurement of disclosure risk that considers the case that all identities are the same or similar. As an application example, we compare the newly proposed measurement and the existing measurement using 10667 data in 'Korea Household Income and Expenditure Survey data for 2010'.

Pressure Sensitive Paint의 성능비교 및 경사충돌분류의 압력장 측정 (Performance Comparison of Pressure Sensitive Paint and Pressure Field Measurement of Oblique Impinging Jet)

  • 이상익;이상준
    • 대한기계학회논문집B
    • /
    • 제26권7호
    • /
    • pp.1031-1038
    • /
    • 2002
  • The pressure sensitive paint (PSP) has recently received a considerable attention in the fields of aerodynamics and fluid mechanics as a new revolutionary optical technique to measure pressure fields on a body surface. In this study, the feasibility and effectiveness of the PSP pressure field measurement technique have been investigated experimentally. Seven different PSP formulations including two porphyrins(PtOEP and PtTFPP) and four polymers(Polystyrene, cellulous acetate butyrate, GP-197 and Silicon-708) were tested to check the performance and characteristics of each combination. The static calibration of each PSP formulation was carried out in a constant-pressure chamber. The PSP technique was applied to an oblique impinging jet flow to measure variation of pressure field on the impinging plate at on oblique jet angle of ${\theta}=60^{\circ}$. Pressure field images were captured by an 12bit intensified CCD(ICCD, $1K{\times}1K$)camera. As a result, the dynamic response of PSP depends on the oxygen permeability of polymer and the photochemical interaction between luminophore and polymer as well as the reaction of luminophore itself. The reaction of luminophore was changed by employing different polymers. In conclusion, Among 7 PSP formulation tested, the combination of PtTFPP and cellulous acetate butyrate show the best performance. In addition, the detail pressure field of an oblique high-speed impinging jet was measured effectively using the PSP technique.

긍/부정 감성자극에 대한 행동활성화체계 및 행동억제체계 민감도에 따른 뇌파의 LORETA 분석 (LORETA analysis of EEG responding to positive/negative emotional stimuli for different sensitivities of behavioral activation and inhibition systems)

  • 김원식;진승현
    • 감성과학
    • /
    • 제8권4호
    • /
    • pp.403-413
    • /
    • 2005
  • 본 연구에서는 긍정 또는 부정 시각자극이 제시되었을 때, 행동활성화체계(Behavioral Activation System : BAS) 민감 집단과 행동억제 체계(Behavioral Inhibition System : BIS) 민감 집단 사이에 차이가 있는지를 살펴보았다. 실험은 8명씩의 BAS와 BIS 민감 성향을 가진 남자 대학생을 대상으로 이루어졌고, 안정 상태와 국제정서사진체계(International Affective Picture System)의 긍정/부정 사진자극이 제시되는 동안의 뇌파를 측정하였다. 뇌파의 분석은 뇌 신호원 국소화를 위해, 뇌파의 전기적 신호에 의하여 형성되는 전류밀도에 대한 3차원적인 접근방식으로 데이터를 처리하는 방법 중의 하나인 LORETA(Low-resolution electromagnetic tomography)를 사용하였다. 그 결과, 긍정자극제시의 경우, BAS 민감 집단이 BIS민감 집단에 비해 알파 대역에서 변연계에 포함되는 cingulate gyrus와 전전두엽이 더 활성화되는 반응을 보였다. 이는 BAS 민감집단이 BIS 민감집단에 비해 긍정자극에 대한 반응이 더 민감하고, BAS 또는 BIS라는 인간의 동기체계가 감성자극의 인지와도 관련이 있을 가능성을 시사한다.

  • PDF

관상동맥우회술의 중증도 측정과 병원 사망률 비교에 관한 연구 (Severity Measurement Methods and Comparing Hospital Death Rates for Coronary Artery Bypass Graft Surgery)

  • 안형식;신영수;권영대
    • Journal of Preventive Medicine and Public Health
    • /
    • 제34권3호
    • /
    • pp.244-252
    • /
    • 2001
  • Objective : Health insurers and policy makers are increasingly examining the hospital mortality rate as an indicator of hospital quality and performance. To be meaningful, a risk-adjustment of the death rates must be implemented. This study reviewed 5 severity measurement methods and applied them to the same data set to determine whether judgments regarding the severity-adjusted hospital mortality rates were sensitive to the specific severity measure. Methods : The medical records of 584 patients who underwent coronary artery bypass graft surgery in 6 general hospitals during 1996 and 1997 were reviewed by trained nurses. The MedisGroups, Disease Staging, Computerized Severity Index, APACHE III and KDRG were used to quantify severity of the patients. The predictive probability of death was calculated for each patient in the sample from a multivariate logistic regression model including the severity score, age and sex to evaluate the hospitals' performance, the ratio of the observed number of deaths to the expected number for each hospital was calculated. Results : The overall in-hospital mortality rate was 7.0%, ranging from 2.7% to 15.7% depending on the particular hospital. After the severity adjustment, the mortality rates for each hospital showed little difference according to the severity measure. The 5 severity measurement methods varied in their statistical performance. All had a higher c statistic and $R^2$ than the model containing only age and sex. There was a little difference in the relative hospital performance evaluation by the severity measure. Conclusion : These results suggest that judgments regarding a hospital's performance based on severity adjusted mortality can be sensitive to the severity measurement method. Although the 5 severity measures regarding hospital performance concurred, more often than would be expected by chance, the assessment of an individual hospital mortality rates varied by the different severity measurement method used.

  • PDF

온도 민감 형광을 이용한 마이크로 스케일 표면온도 측정 (Surface Temperature Measurements in Microscale with Temperature Sensitive Fluorescence)

  • 정운섭;김성욱;김호영;유정열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1225-1230
    • /
    • 2004
  • The effects of substrate material on the local heating performance of microheaters are studied by both numerical analysis and experiment. Transient conduction analysis shows that the substrate material with low thermal conductivity is critical to the local heating and fast response. A measurement technique for surface temperature field in microscale is newly proposed, which uses temperature sensitive fluorescent dye coated on the surface. The measured surface temperature fields on microheater arrays fabricated on different substrates are presented.

  • PDF

Significance of a Highly Specific and Sensitive Enzyme Linked Immunosorbent Assay on Evaluation of Environmental Toxicant-Mediated Allergic Responses

  • Kim, Hyoung-Ah;Yong Heo
    • Toxicological Research
    • /
    • 제17권
    • /
    • pp.197-199
    • /
    • 2001
  • Enhancement of antigen-specific IgE is a hallmark of allergic hyperresponsiveness, therefore it is necessary to adopt or develop a highly sensitive and specific assay for determination of allergen-specific IgE levels in vivo. In this presentation, we introduce an ELISA (enzyme linked immunosorbent assay) system developed to measure the levels of chicken egg ovalbumin (OVA)-specific IgE in serum. The ELISA method uses a commercially available purified rat anti-mouse IgE as a capture Ab and biotinylated OVA as a detection reagent. Avidin-peroxidase with its substrate is used for color development resulting in optical density measurement at 405 nm. The ELISA system produces a highly sensitive dose-response relation-ship between optical density levels and the dilution titer of the OVA-IgE standard serum but no cross-reaction with unrelated IgE or IgG. It is believed that the system is an Efficient tool to delineate an adjuvant effect of environmental pollutants on development of asthmatic and atopic responses.

  • PDF

디지털 화상처리에 의한 해양유출기름확산 계측기법개발에 관한 연구 (A study on a development of a measurement technique for diffusion of oil spill in the ocean)

  • 이중우;김기철;강신영;도덕희
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1998년도 추계학술대회논문집:21세기에 대비한 지능형 통합항만관리
    • /
    • pp.211-221
    • /
    • 1998
  • A digital image processing technique which is able to get the velocity vector distribution of a surface of the spilled oil in the ocean without contacting the flow itself. This technique is based upon the PIV(Particle Imaging Velocimetry) technique and its system mainly consists of a high sensitive camera, a CCD camera, an image grabber, and a host computer in which an image processing algorithm is adopted for velocity vector acquisition. For the acquisition of the advective velocity vector of floating matters on the ocean, a new multi-frame tracking algorithm is proposed, and for the acquisition of the diffusion velocity vector distribution of the spilt oil onto the water surface, a high sensitive gray-level cross-correlation algorithm is proposed.

  • PDF

3D Nano Object Recognition based on Phase Measurement Technique

  • Kim, Dae-Suk;Baek, Byung-Joon;Kim, Young-Dong;Javidi, Bahram
    • Journal of the Optical Society of Korea
    • /
    • 제11권3호
    • /
    • pp.108-112
    • /
    • 2007
  • Spectroscopic ellipsometry (SE) has become an important tool in scatterometry based nano-structure 3D profiling. In this paper, we propose a novel 3D nano object recognition method by use of phase sensitive scatterometry. We claims that only phase sensitive scatterometry can provide a reasonable 3D nano-object recognition capability since phase data gives much higher sensitive 3D information than amplitude data. To show the validity of this approach, first we generate various $0^{th}$ order SE spectrum data ($\psi$ and ${\Delta}$) which can be calculated through rigorous coupled-wave analysis (RCWA) algorithm and then we calculate correlation values between a reference spectrum and an object spectrum which is varied for several different object 3D shape.