• Title/Summary/Keyword: semi-energy

Search Result 864, Processing Time 0.025 seconds

Validation of a 750 kW semi-submersible floating offshore wind turbine numerical model with model test data, part II: Model-II

  • Kim, Junbae;Shin, Hyunkyoung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.213-225
    • /
    • 2020
  • Floating Offshore Wind Turbines (FOWT) installed in the deep sea regions where stable and strong wind flows are abundant would have significantly improved energy production capacity. When designing FOWT, it is essential to understand the stability and motion performance of the floater. Water tank model tests are required to evaluate these aspects of performance. This paper describes a model test and numerical simulation for a 750-kW semi-submersible platform wind turbine model-II. In the previous model test, the 750-kW FOWT model-I suffered slamming phenomena from extreme wave conditions. Because of that, the platform freeboard of model-II was increased to mitigate the slamming load on the platform deck structure in extreme conditions. Also, the model-I pitch Response Amplitude Operators (RAO) of simulation had strong responses to the natural frequency region. Thus, the hub height of model-II was decreased to reduce the pitch resonance responses from the low-frequency response of the system. Like the model-I, 750-kW FOWT model-II was built with a 1/40 scale ratio. Furthermore, the experiments to evaluate the performance characteristics of the model-II wind turbine were executed at the same location and in the same environment conditions as were those of model-I. These tests included a free decay test, and tests of regular and irregular wave conditions. Both the experimental and simulation conditions considered the blade rotating effect due to the wind. The results of the model tests were compared with the numerical simulations of the FOWT using FAST (Fatigue, Aerodynamics, Structures, and Turbulence) code from the National Renewable Energy Laboratory (NREL).

AZO Transparent Electrodes for Semi-Transparent Silicon Thin Film Solar Cells (AZO 투명 전극 기반 반투명 실리콘 박막 태양전지)

  • Nam, Jiyoon;Jo, Sungjin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.6
    • /
    • pp.401-405
    • /
    • 2017
  • Because silicon thin film solar cells have a high absorption coefficient in visible light, they can absorb 90% of the solar spectrum in a $1-{\mu}m$-thick layer. Silicon thin film solar cells also have high transparency and are lightweight. Therefore, they can be used for building integrated photovoltaic (BIPV) systems. However, the contact electrode needs to be replaced for fabricating silicon thin film solar cells in BIPV systems, because most of the silicon thin film solar cells use metal electrodes that have a high reflectivity and low transmittance. In this study, we replace the conventional aluminum top electrode with a transparent aluminum-doped zinc oxide (AZO) electrode, the band level of which matches well with that of the intrinsic layer of the silicon thin film solar cell and has high transmittance. We show that the AZO effectively replaces the top metal electrode and the bottom fluorine-doped tin oxide (FTO) substrate without a noticeable degradation of the photovoltaic characteristics.

Removal of diesel hydrocarbons by microwave-enhanced soil vapor extraction (Focused on Loss and Kinetic constant for Diesel Hydrocarbons)

  • 김종운;박갑성
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.223-226
    • /
    • 2004
  • In this paper, removal of diesel hydrocarbons (C$_{10}$-C$_{22}$) for dry and moist soil was investigated so that microwave-enhanced soil vapor extraction(SVE) reduced soil treatment time and raised remediation efficiency. Kinetic constants of diesel hydrocarbons with microwave energy were 7 times on dry soil and 1580 times on moist soil as much as those of SVE process without microwave energy. The diesel removals were 67.7~78.4% for $C_{10}$ and $C_{12}$, and 0~18.5% for $C_{14}$~C$_{22}$ for dry and moist soil with SVE process only. On the other hand, dry soil with microwave-enhanced SVE process showed 89.3~99.4% removal for $C_{10}$ and $C_{12}$ and 35.6~67.0% for hydrocarbons over $C_{14}$. All hydrocarbons(C$_{10}$~C$_{22}$) studied were significantly removed (93.6~99.8%) for moist soil with microwave-enhanced SVE process. Almost all diesel hydrocarbons were usually considered as semi-volatile compounds(SVOCs). Microwave-enhanced SVE process might have a great potential for remediation of soils contaminated with SVOCs.OCs.

  • PDF

Analysis of the turbulent flow on the periodically arranged semi-circular ribs in a rectangular channel (사각채널 내 주기적으로 배열된 반원 리브 영향의 유동해석)

  • Lee, G.H.;Nine, Md.J.;Choi, S.H.;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.15 no.2
    • /
    • pp.31-36
    • /
    • 2011
  • The flow characteristics on the periodically arranged semi-circular ribs in a rectangular channel for turbulent flow have been investigated numerically. The aspect ratio of the rectangular channel was AR=5, the rib height to hydraulic diameter ratio was 0.07 and rib height to channel height ratio was e/H=0.117. The v2-f turbulence model and SST k-${\omega}$ turbulence model were used to find the flow characteristics of near the wall which are suited for realistic phenomena. The numerical analysis results show turbulent flow characteristics and pressure drop at the near the wall as observed experimentally. The results predict that turbulent kinetic energy(k) is closely relative to the diffusion of recirculation flow, and v2-f turbulence model simulation results have a good agreement with experimental.

Semi-analytical solutions for optimal distributions of sensors and actuators in smart structure vibration control

  • Jin, Zhanli;Yang, Yaowen;Soh, Chee Kiong
    • Smart Structures and Systems
    • /
    • v.6 no.7
    • /
    • pp.767-792
    • /
    • 2010
  • In this paper, the optimal design of vibration control system for smart structures has been investigated semi-analytically via the optimization of geometric parameters like the placements and sizes of piezoelectric sensors and actuators (S/As) bonded on the structures. The criterion based on the maximization of energy dissipation was adopted for the optimization of the control system. Based on the sensing and actuating equations, the total energy stored in the system which is used as the objective function was analytically derived with design variables explicitly presented. Two cases of single and combined vibration modes were addressed for a simply supported beam and a simply supported cylindrical shell. For single vibration mode, the optimal distributions of the piezoelectric S/As could be obtained analytically. However, the Sequential Quadratic Programming (SQP) method has to be employed to solve those which violated the prescribed constraints and to solve the case of combined vibration modes. The results of three examples, which include a simply supported beam, a simply supported cylindrical shell and a simply supported plate, showed good agreement with those obtained by the Genetic Algorithm (GA) method. Moreover, in comparison with the GA method, the proposed method is more effective in obtaining better optimization results and is much more efficient in terms of computation time.

Influence of stiffeners on the performance of blind-bolt end-plate connections to CFST columns

  • Ding, Fa-xing;Pan, Zhi-cheng;Liu, Peng;Huang, Shi-jian;Luo, Liang;Zhang, Tao
    • Steel and Composite Structures
    • /
    • v.36 no.4
    • /
    • pp.447-462
    • /
    • 2020
  • The paper aims to investigate the mechanical mechanism and seismic effect of stiffeners in blind bolt endplate connection to CFST column. A precise 3D finite element model with considering the cyclic properties of concrete and steel materials was established, and the efficiency was validated through monotonic and cyclic test data. The deforming pattern and the seismic performance of the unstiffened and stiffened blind bolt endplate connections were investigated. Then a parametric analysis was conducted to analyze the contribution of stiffeners and the joint working behaviors with endplate under cyclic load. The joint stiffness classifications were compared and a supplement stiffness classification method was proposed, and the energy dissipation ability of different class connections were compared and discussed. Results indicated that the main deformation pattern of unstiffened blind bolt endplate connections was the local bending of end plate. The vertical stiffeners can effectively alleviate the local bending deformation of end plate. And influence of stiffeners in thin endplate and thick endplate was different. Based on the stiffness of external diaphragm welded connection, a more detailed rigidity classification was proposed which included the pin, semi-rigid, quasi-rigid and rigid connection. Beam was the main energy dissipation source for rigid connection. For the semi-rigid and quasi-rigid connection, the extended endplate, stiffeners and steel beam would all participate in the energy dissipation.

The effects of beam-column connections on behavior of buckling-restrained braced frames

  • Hadianfard, Mohammad Ali;Eskandari, Fateme;JavidSharifi, Behtash
    • Steel and Composite Structures
    • /
    • v.28 no.3
    • /
    • pp.309-318
    • /
    • 2018
  • Buckling Restrained Braced (BRB) frames have been widely used as an efficient seismic load resisting system in recent years mostly due to their symmetric and stable hysteretic behavior and significant energy dissipation capacity. In this study, to provide a better understanding of the behavior of BRB frames with various beam-column connections, a numerical study using non-linear finite element (FE) analysis is conducted. All models are implemented in the Abaqus software package following an explicit formulation. Initially, the results of the FE model are verified with experimental data. Then, diverse beam-column connections are modeled for the sake of comparison from the shear capacity, energy dissipation and frame hysteresis behavior points of view until appropriate performance is assessed. The considered connections are divided into three different categories: (1) simple beam-column connections including connection by web angle and connection by seat angle; (2) semi-rigid connection including connection by web and seat angles; and (3) rigid beam-column connections by upper-lower beam plates and beam connections with web and flange splices. Results of the non-linear FE analyses show that these types of beam-column connections have little effect on the maximum story drift and shear capacity of BRB frames. However, the connection type has a significant effect on the amount of energy dissipation and hysteresis behavior of BRB frames. Also, changes in length and thickness of the angles in simple and semi-rigid connections and changes in length and thickness of plates in rigid connections have slight effects (less than 4%) on the overall frame behavior.

Synthesis of Dimethyl Carbonate by Oxidative Carbonylation of Methanol over Cu Catalysts (구리촉매 상에서의 메탄을 산화카르보닐화에 의한 디메틸카보네이트 합성)

  • Park, Jin-Seok;Suh, Young-Woong;Park, Tae-Jin;Suh, Dong-Jin
    • Clean Technology
    • /
    • v.14 no.3
    • /
    • pp.160-165
    • /
    • 2008
  • The synthesis of dimethyl carbonate (DMC) with Cu catalysts was investigated in a semi-batch high-pressure reactor. DMC was synthesized via the direct oxidative carbonylation of carbon monoxide with oxygen in methanol. The corrosion rate was evaluated fie the weight change for SUS test pieces which had been added into the reactor. In order to reduce the corrosion rate without significantly losing DMC yield, various additives such as amines, olefins, and other metal salts were used. When 1-methylimidazole was used as an additive, 18.6% of DMC yield could be obtained without corrosion. If the amount of 1-methylimidazole was decreased, a high DMC yield (33.2%) could be obtained with a low corrosion rate (0.5%).

  • PDF

A study of prosodic features of patients with idiopathic Parkinson's disease (파킨슨병 환자와 정상노인 간의 문장 읽기에 나타난 운율 특성 비교)

  • Kang, Young-Ae;Seong, Cheol-Jae;Yoon, Kyu-Chul
    • Phonetics and Speech Sciences
    • /
    • v.3 no.1
    • /
    • pp.145-151
    • /
    • 2011
  • In view of the hypothesis that the effects of Parkinson's disease on voice production can be detected before pharmacological intervention, the prosodic features of patients with idiopathic Parkinson's disease (IPD) and a healthy aging group were diagnostically analyzed with the long term object of establishing, for clinical purposes, early disease-progression biomarkers. Twenty patients (male 8; female 12) with IPD (prior to pharmacological intervention) and a healthy control group of 22 (male 10; female 12) were selected. Ten sentences were recorded with a head-worn microphone. One sentence was chosen for the analysis of this paper. Relevant parameters, i.e. 3-dimensional model (F0, intensity, duration) and pitch and intensity related slopes (maxEnergy, maxF0, meanAbS, semiT, meanEnergy, meanF0), were analyzed by two-group discriminant analysis. The stepwise estimation method of discriminant analysis was performed by gender. The discriminant functions predicted 83.9% of the male test data correctly while the prediction rate was 93.1% for the female group. The results showed that meanF0_slope and semiT_slope were more important parameters than the others for the male group. For the female group, the meanEnergy_slope and maxEnergy_slope were the important ones. These findings indicate that significant parameters are different for the male and female group. Gender lifestyle may be responsible for this difference. Dysprosodic features of IPD show not simultaneously but progressively in terms of F0, intensity and duration.

  • PDF

Optimal Capacity Determination of Hydrogen Fuel Cell Technology Based Trigeneration System And Prediction of Semi-closed Greenhouse Dynamic Energy Loads Using Building Energy Simulation (건물 에너지 시뮬레이션을 이용한 반밀폐형 온실의 동적 에너지 부하 예측 및 수소연료전지 3중 열병합 시스템 적정 용량 산정)

  • Seung-Hun Lee;Rack-Woo Kim;Chan-Min Kim;Hee-Woong Seok;Sungwook Yoon
    • Journal of Bio-Environment Control
    • /
    • v.32 no.3
    • /
    • pp.181-189
    • /
    • 2023
  • Hydrogen has gained attention as an environmentally friendly energy source among various renewable options, however, its application in agriculture remains limited. This study aims to apply the hydrogen fuel cell triple heat-combining system, originally not designed for greenhouses, to greenhouses in order to save energy and reduce greenhouse gas emissions. This system can produce heating, cooling, and electricity from hydrogen while recovering waste heat. To implement a hydrogen fuel cell triple heat-combining system in a greenhouse, it is crucial to evaluate the greenhouse's heating and cooling load. Accurate analysis of these loads requires considering factors such as greenhouse configuration, existing heating and cooling systems, and specific crop types being cultivated. Consequently, this study aimed to estimate the cooling and heating load using building energy simulation (BES). This study collected and analyzed meteorological data from 2012 to 2021 for semi-enclosed greenhouses cultivating tomatoes in Jeonju City. The covering material and framework were modeled based on the greenhouse design, and crop energy and soil energy were taken into account. To verify the effectiveness of the building energy simulation, we conducted analyses with and without crops, as well as static and dynamic energy analyses. Furthermore, we calculated the average maximum heating capacity of 449,578 kJ·h-1 and the average cooling capacity of 431,187 kJ·h-1 from the monthly maximum cooling and heating load analyses.