• 제목/요약/키워드: semi-active vibration

검색결과 226건 처리시간 0.024초

Control of wind-induced motion in high-rise buildings with hybrid TM/MR dampers

  • Aly, Aly Mousaad
    • Wind and Structures
    • /
    • 제21권5호
    • /
    • pp.565-595
    • /
    • 2015
  • In recent years, high-rise buildings received a renewed interest as a means by which technical and economic advantages can be achieved, especially in areas of high population density. Taller and taller buildings are being built worldwide. These types of buildings present an asset and typically are built not to fail under wind loadings. The increase in a building's height results in increased flexibility, which can lead to significant vibrations, especially at top floors. Such oscillations can magnify the overall loads and can be annoying to the top floors' occupants. This paper shows that increased stiffness in high-rise buildings may not be a feasible solution and may not be used for the design for comfort and serviceability. High-rise buildings are unique, and a vibration control system for a certain building may not be suitable for another. Even for the same building, its behavior in the two lateral directions can be different. For this reason, the current study addresses the application of hybrid tuned mass and magneto-rheological (TM/MR) dampers that can work for such types of buildings. The proposed control scheme shows its effectiveness in reducing floors' accelerations for both comfort and serviceability concerns. Also, a dissipative analysis carried out shows that the MR dampers are working within the possible range of optimum performance. In addition, the design loads are dramatically reduced, creating more resilient and sustainable buildings. The purpose of this paper is to stimulate, shape, and communicate ideas for emerging control technologies that are essential for solving wind related problems in high-rise buildings, with the objective to build the more resilient and sustainable infrastructure and to optimally retrofit existing structures.

MR 댐퍼를 이용한 비대칭 사장교의 지진 진동제어 성능평가 (Performance Evaluation of Seismic Vibration Control of Asymmetrical Cable-Stayed Bridge Using MR Damper)

  • 허광희;김충길;공영이
    • 대한토목학회논문집
    • /
    • 제34권3호
    • /
    • pp.729-737
    • /
    • 2014
  • 비대칭 사장교에 지진으로 인한 진동을 MR(Magneto-rheological) 댐퍼를 이용하여 효과적으로 제어하는 연구를 수행하였다. MR 댐퍼의 실용적인 사용성을 높이기 위하여 비대칭 사장교 구조물을 설계/제작하고, 이 교량구조물을 적정하게 제어할 수 있도록 MR 댐퍼를 제작하였다. El-centro 지진파로 비대칭 사장교를 수평방향으로 가진하여 수직방향과 수평방향의 진동을 제어하는 실험을 하였다. 각 방향의 진동제어 실험에 5가지의 제어 조건으로 MR 댐퍼의 제어성능을 평가 하였다. 실험결과 MR 댐퍼는 지진진동으로 인한 비대징사장교를 진동제어 하기 위하여 Lyapunov Control 알고리즘과 Clipped-optimal control 알고리즘을 이용하여 제어를 할 경우, 보다 효과적으로 진동을 제어하는 것을 알 수 있었다. 그리고 구조물의 비대칭성과 수평 가진으로 인하여 수직 및 수평 방향의 진동제어가 서로 다른 제어효과를 보였다. 이와 같은 제어효과는 비대칭 사장교와 같은 유연하며 비대칭인 구조물에 준능동의 MR 댐퍼가 효과적으로 지진진동을 제어하는 것으로 평가되었다.

컨트롤 샘플링 주기가 스위칭 시스템의 결합-분리 횟수에 미치는 영향을 고려한 제어 알고리듬 개발 (Development of Control Algorithms Considering the Effect of a Control Sampling Period on the Total Amount of Switching for a Switched System)

  • 정진욱;정란
    • 한국지진공학회논문집
    • /
    • 제13권4호
    • /
    • pp.67-76
    • /
    • 2009
  • 최근에 Active interaction control(AIC) 시스템이 준능동 제어 시스템의 하나로 제안되었다. AIC 시스템은 제어 대상 구조물과 보조 구조물로 구성되며, 두 구조물간의 실시간 결합-분리를 통해서 제어 대상 구조물을 제어하게 된다. 구조물간의 결합과 분리를 담당하는 장치의 실시간 변환은 스위칭 제어 알고리듬의 결합-분리 조건식에 의해 제어된다. 기존 스위칭 제어 알고리듬의 경우, 제어 대상 구조물의 응답을 효과적으로 감소시키는 반면 불필요하게 큰 제어력과 과도한 결합-분리 횟수를 필요로 하는 단점을 가지고 있다. 본 논문에서는 구조물간의 효율적인 결합-분리 조정을 위해서 스위칭 활성화 영역과 스위칭 비활성화 영역을 분리 표현하였으며, 결합-조건식에 의해 결정되는 스위칭 활성화 영역과 스위칭 비활성화 영역간의 일반적인 관계를 포괄 스위칭 틀을 이용하여 나타냈다. 과도한 결합-분리 횟수와 불필요하게 큰 제어력의 효과적인 감소를 위해서 새로운 스위칭 제어 알고리듬의 결합-분리 조건식은 포괄 스위칭 틀안에서 설계되었다. 또한 기존 논문에서 사용된 컨트롤 샘플링 주기(Control sampling period)의 역할을 결합-분리 횟수의 관점에서 재해석하였다. 제안된 알고리듬의 효용성과 컨트롤 샘플링 주기의 역할을 검증하기 위해서 단자유도 모델을 이용하여 자유진동에 대한 수치해석을 수행하였다. 수치해석결과, 총 스위칭 횟수를 감소시키기 위한 컨트롤 샘플링 주기의 인위적인 연장은 시스템의 제어 성능 향상에 필요한 구간 변환을 샘플링 주기 사이에서 억제시키는 단점을 가지고 있음을 확인하였다. 본 논문에서 제안된 알고리듬의 경우, 각각 과도한 결합-분리 횟수와 불필요하게 큰 제어력을 감소시키는데 효과적임을 알 수 있다.

Magnetorheological elastomer base isolator for earthquake response mitigation on building structures: modeling and second-order sliding mode control

  • Yu, Yang;Royel, Sayed;Li, Jianchun;Li, Yancheng;Ha, Quang
    • Earthquakes and Structures
    • /
    • 제11권6호
    • /
    • pp.943-966
    • /
    • 2016
  • Recently, magnetorheological elastomer (MRE) material and its devices have been developed and attracted a good deal of attention for their potentials in vibration control. Among them, a highly adaptive base isolator based on MRE was designed, fabricated and tested for real-time adaptive control of base isolated structures against a suite of earthquakes. To perfectly take advantage of this new device, an accurate and robust model should be built to characterize its nonlinearity and hysteresis for its application in structural control. This paper first proposes a novel hysteresis model, in which a nonlinear hyperbolic sine function spring is used to portray the strain stiffening phenomenon and a Voigt component is incorporated in parallel to describe the solid-material behaviours. Then the fruit fly optimization algorithm (FFOA) is employed for model parameter identification using testing data of shear force, displacement and velocity obtained from different loading conditions. The relationships between model parameters and applied current are also explored to obtain a current-dependent generalized model for the control application. Based on the proposed model of MRE base isolator, a second-order sliding mode controller is designed and applied to the device to provide a real-time feedback control of smart structures. The performance of the proposed technique is evaluated in simulation through utilizing a three-storey benchmark building model under four benchmark earthquake excitations. The results verify the effectiveness of the proposed current-dependent model and corresponding controller for semi-active control of MRE base isolator incorporated smart structures.

Mechanical performance analysis of an electromagnetic friction pendulum system based on Maxwell's principle

  • Mao Weikang;Li Xiaodong;Chen Enliang
    • Earthquakes and Structures
    • /
    • 제27권2호
    • /
    • pp.143-154
    • /
    • 2024
  • Friction pendulums typically suffer from poor uplift-restraining. To improve the uplift-restraining and enhance the energy dissipation capacity, this article proposed a composite isolation device based on electromagnetic forces. The device was constructed based on a remote control system to achieve semi-active control of the composite isolation device. This article introduces the theory and design of an electromagnetic chuck-friction pendulum system (ECFPS) and derives the theoretical equation for the ECFPS based on Maxwell's electromagnetic attraction equation to construct the proposed model. By conducting 1:3 scale tests on the electromagnetic device, the gaps between the practical, theoretical, and simulation results were analyzed, and the accuracy and effectiveness of the theoretical equation for the ECFPS were investigated. The hysteresis and uplift-restraining performance of ECFPS were analyzed by adjusting the displacement amplitude, vertical load, and input current of the simulation model. The data obtained from the scale test were consistent with the theoretical and simulated data. Notably, the hysteresis area of the ECFPS was 35.11% larger than that of a conventional friction pendulum. Lastly, a six-story planar frame structure was established through SAP2000 for a time history analysis. The isolation performances of ECFPS and FPS were compared. The results revealed that, under horizontal seismic action, the horizontal seismic response of the bottom layer of the ECFPS isolation structure is greater than that of the FPS, the horizontal vibration response of the top layer of the ECFPS isolation structure is smaller than that of the FPS, and the axial force at the bottom of the columns of the ECFPS isolation structure is smaller than that of the FPS isolation structure. Therefore, the reliable uplift-restraining performance is facilitated by the electromagnetic force generated by the device.

케이블-댐퍼 시스템의 전체감쇠비 해석을 통한 선형조합 접근법의 유효성 (Validity of Linear Combination Approach based on Net Damping Analysis of Cable-Damper System)

  • 김현겸;황재웅;이명재
    • 대한토목학회논문집
    • /
    • 제29권5A호
    • /
    • pp.467-475
    • /
    • 2009
  • 기존의 연구들은 댐퍼만에 의한 부가감쇠비의 Universal Curve만을 제공하였기 때문에 실무에서는 케이블의 구조감쇠 및 공기역학적감쇠와 같은 자체감쇠를 독립적으로 고려하곤 한다. 즉, 케이블에 발생하는 자체감쇠비와 댐퍼에 의해 부여되는 Universal Curve로부터 얻은 부가감쇠비를 산술적으로 합하여 케이블-댐퍼 시스템의 전체감쇠비를 결정해 왔다. 하지만 이러한 선형조합 접근법은 이론적인 근거가 미약하며 관련된 연구도 찾아볼 수 없는 실정이므로 이에 관한 유효성을 검증해 볼 필요가 있다. 이것을 위해 본 연구에서는 자체감쇠를 고려한 전체감쇠비 해석법을 개발하여 정해를 제시하고 이것을 기존의 선형조합 접근법에 의해 얻어진 전체감쇠비와 비교하여 선형조합 접근법의 유효성 여부를 검증하였다. 본 연구의 결과에 의하면, 강성은 작고 최적감쇠계수와 비슷한 감쇠계수를 갖는 댐퍼가 지점에서 가깝게 설치되어 있으며, 케이블의 진동이 저차 모드 위주로 발생하고 케이블의 자체감쇠가 크지 않은 일반적인 풍환경에서는 기존의 연구그룹에서 제시하는 연구결과나 선형조합 접근법을 적용하는 것에 무리가 따르지 않는다. 하지만 외부댐퍼나 예기치 못한 고차 진동모드의 발생, 강성이 큰 댐퍼가 사용되는 경우에는 본 연구를 적용하는 것이 바람직한 것으로 나타났다. 본 연구는 케이블의 자체감쇠를 고려한 전체감쇠비의 정해를 제시하고 이것을 토대로 선형조합 접근법에 대한 적용근거를 제시하였다는 점에서 의미를 찾을 수 있다. 차후 본 연구를 발전시켜 공기역학적감쇠에 대응하는 최적감쇠계수를 실시간으로 제시할 수 있게 된다면 MR(Magneto-rheological) 댐퍼와 같은 준능동 댐퍼의 케이블-댐퍼 시스템 제어의 중요한 알고리즘이 될 것으로 기대된다.