• Title/Summary/Keyword: self-adhesive

Search Result 303, Processing Time 0.032 seconds

Characteristics of Change in Properties of Self-Adhesive Butyl Rubber Waterproofing Sheet by Increasing the Amount of Reclaimed Rubber (자착식 부틸고무 방수시트의 재생고무 증량 배합에 따른 물성변화 특성)

  • Choi, Su-Young;Park, Jin-Sang;Choi, Sung-Min;Kwon, Young-Hwa;Kim, Young-Keun;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.252-253
    • /
    • 2021
  • In this study, butyl rubber, which is the main material constituting the self-adhesive butyl rubber waterproofing sheet, was mixed with reclaimed rubber, and tensile strength, tear strength, peeling resistance strength, and adhesion strength were measured for sample prepared by mixing ratio. As a result, it was confirmed that peeling resistance strength and adhesion strength decreased as the reclaimed rubber content increased, and tensile strength and tear strength did not change significantly.

  • PDF

A Study on Tensile Shear Characteristics of Dissimilar Joining Between Pre-coated Automotive Metal Sheets and Galvanized Steels with the Self-Piercing Rivet and Hybrid Joining (Self-Piercing Rivet과 Hybrid Joining을 이용한 자동차용 선도장 칼라강판과 용융아연도금강판의 접합부 기계적 성질 평가)

  • Bae, Jin-Hee;Kim, Jae-Won;Choi, Ildong;Nam, Dae-Geun;Kim, Jun-Ki;Park, Yeong-Do
    • Journal of Welding and Joining
    • /
    • v.34 no.1
    • /
    • pp.59-67
    • /
    • 2016
  • The automotive manufactures increase their use of lightweight materials to improve fuel economy and energy usage has a significant influence on the choice of developing materials. To meet this requirements manufacturers are replacing individual body parts with lightweight metals, for these the process treating and painting surfaces is changing. The pre-coated steels are newly developed to avoid the conventional complex and non-environmental painting process in the body-in-white car manufacturing. The development of new joining techniques is critically needed for pre-coated steel sheets, which are electrically non-conductive materials. In the present study, dissimilar combination of pre-coated steel and galvanized steel sheets were joined by the self-piercing rivet, adhesive bonding and hybrid joining techniques. The tensile shear test and free falling high speed crash test were conducted to evaluate the mechanical properties of the joints. The highest tensile peak load with large deformation was observed for the hybrid joining process which has attained 48% higher than the self-piercing rivet. Moreover, the hybrid and adhesive joints were observed better strain energy compared to self-piercing rivet. The fractography analyses were revealed that the mixed mode of cohesive and interfacial fracture for both the hybrid and adhesive bonding joints.

Influence of 10-MDP concentration on the adhesion and physical properties of self-adhesive resin cements

  • Shibuya, Kazuhiko;Ohara, Naoko;Ono, Serina;Matsuzaki, Kumiko;Yoshiyama, Masahiro
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.4
    • /
    • pp.45.1-45.10
    • /
    • 2019
  • Objectives: Self-adhesive resin cements contain functional monomers that enable them to adhere to the tooth structure without a separate adhesive or etchant. One of the most stable functional monomers used for chemical bonding to calcium in hydroxyapatite is 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP). The aim of this study was to evaluate the influence of the10-MDP concentration on the bond strength and physical properties of self-adhesive resin cements. Materials and Methods: We used experimental resin cements containing 3 different concentrations of 10-MDP: 3.3 wt% (RC1), 6.6 wt% (RC2), or 9.9 wt% (RC3). The micro-tensile bond strength of each resin cement to dentin and a hybrid resin block (Estenia C&B, Kuraray Noritake Dental) was measured, and the fractured surface morphology was analyzed. Further, the flexural strength of the resin cements was measured using the three-point bending test. The water sorption and solubility of the cements following 30 days of immersion in water were measured. Results: The bond strength of RC2 was significantly higher than that of RC1. There was no significant difference between the bond strength of RC2 and that of RC3. The water sorption of RC3 was higher than that of any other cement. There were no significant differences in the three-point bending strength or water solubility among all three types of cements. Conclusions: Within the limitations of this study, it is suggested that 6.6 wt% 10-MDP showed superior properties than 3.3 wt% or 9.9 wt% 10-MDP in self-adhesive resin cement.

EFFECT OF INTERMEDIATE RESIN HYDROPHILICITY ON BOND STRENGTH OF SINGLE STEP ADHESIVE (중간레진의 친수성이 상아질 접착에 미치는 영향)

  • Kim, Yong-Sung;Park, Sang-Hyuk;Choi, Gi-Woon;Choi, Kyoung-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.5
    • /
    • pp.445-458
    • /
    • 2007
  • The purpose of this study was to evaluate the bond strength of a new Single step system with different curing mode composites, and to evaluate the effect of the intermediate resins which have different hydrophilicity on bonding ability by means of the micro shear bond testing and TEM examination for the adhesive interface. The adhesive used in this study was an experimental single step system (Bisco Inc., Schaumburg IL). Experimental groups were produced by using six kinds of intermediate resin having different hydrophilicity that was hydrophilic, hydrophobic and most hydrophobic resin and as filled or not after applying adhesive. Each experimental group was further divided into two subgroups whether the adhesive was light cured or not. Dual cured composite (Bis Core, Bisco Ltd., Schaumburg, IL) was placed on the adhesive layer as light cure or self cure mode. The results or bond strength were statistically analyzed using one way ANOVA and multiple comparisons are made using Tukey's test at ${\alpha}\;<\;0.05$ level. The results of this study were as follows ; 1. The application of intermediate resin did not increase the bond strength for light cured composite. 2. The bond strength of an experimental adhesive with self cured composite was significantly increased by the application of intermediate resin layer. 3. The bond strength of adhesive was irrespective of the cure or not of itself before intermediate resin layer applied. 4. As applied hydrophilic resin layer was, the initial bond strength was higher than both hydrophobic and most hydrophobic one used but there was no significance. Using a single step adhesive with dual/self cured composite, the incompatibility between both of them should be solved by the application of intermediate hydrophobic resin to reduce the adhesive permeability. However, Single step adhesive can be used in the light cured composite restoration without any decrease of the initial bond strength.

THE EFFECT OF HYBRID LAYER THICKNESS ON MICROTENSILE BOND STRENGTH OF THREE-STEP AND SELF-ETCHING DENTIN ADHESIVE SYSTEMS (혼성층의 두께가 three-step과 self-etching 상아질 접착제의 미세인장결합강도에 미치는 효과)

  • Lee, Hye-Jung;Park, Jeong-Kil;Hur, Bock
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.6
    • /
    • pp.491-497
    • /
    • 2003
  • The purpose of this study was to evaluate the correlation between hybrid layer thickness and bond strength using confocal laser scanning microscope and microtensile bond strength test of two adhesive systems. The dentin surface of human molars. sectioned to remove the enamel from the occlusal surface. Either Scotchbond Multi-Purpose(3M Dental Product, St. Paul, MN, U.S.A) or Clearfil SE Bond (Kuraray, Osaka, Japan) was bonded to the surface. and covered with resin-composite. The resin-bonded teeth were serially sliced perpendicular to the adhesive interface to measure the hybrid layer thickness by confocal laser scanning microscope. The specimen were trimmed to give a bonded cross-sectional surface area of $1\textrm{mm}^2$, then the micro-tensile bone test was performed at a cross head speed of 1.0 mm/min. All fractured surfaces were also observed by stereomicroscope. There was no significant differences in bond strengths the materials(p>0.05). However. the hybrid layers of three-step dentin adhesive system, SM, had significantly thicker than self-etching adhesive system. CS(p<0.05). Pearson's correlation coefficient showed no correlation between hybrid layer thickness and bond strengths(p>0.05). Bond strengths of dentin adhesive systems were not dependent on the thickness of hybrid layer.

Self-Assembling Adhesive Bonding by Using Fusible Alloy Paste for Microelectronics Packaging

  • Yasuda, Kiyokazu
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.3
    • /
    • pp.53-57
    • /
    • 2011
  • In the modern packaging technologies highly condensed metal interconnects are typically formed by highcost processes. These methods inevitably require the precise controls of mutually dependant process parameters, which usually cause the difficulty of the change in the layout design for interconnects of chip to-chip, or chip-to-substrate. In order to overcome these problems, the unique concept and methodology of self-assembly even in micro-meter scale were developed. In this report we focus on the factors which influenced the self-formed bumps by analyzing the phenomenon experimentally. In case of RMA flux, homogenous pattern was obtained in both plain surface and cross-section surface observation. By using RA flux, the phenomena were accelerated although the self-formtion results was inhomogenous. With ussage of moderate RA flux, reaction rate of the self-formation was accelerated with homogeneous pattern.

RESIN TAG FORMATION OF SELF-ETCHING ADHESIVES (자가부식 접착제의 레진 Tag 형성)

  • Kim, Young-Jae;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.143-152
    • /
    • 2003
  • The aims of the present study was to observe resin tag of the resin/enamel, dentin interface produced by self-etching adhesive systems and evaluate effect of additional acid etching on resin tag formation. Three self-etching primer(SE bond, AQ bond and L Pop) and an one bottle adhesive(Single bond) were used. Flat occlusal enamel and dentin disks were obtained from extracted human molars. A total of 20 surfaces were collected and divided into four groups of 5 samples. One-half of each specimen in each group was etched with 35% phosphoric acid prior to the application of each adhesive system, with the second half being kept unetched. Subsequently, resin composite was placed and polymerized. The samples were sliced and immersed into HCl and NaOCl solutions, followed by drying and sputter coating for examination with a SEM. The results were as follows; 1. Additional etching side of dentin displayed longer and thicker resin tag than unetched side in all self-etching adhesive groups. 2. In enamel, additional etching side displayed deeper and more distinct etching pattern than unetched side except L Pop. There is no difference between etched and unetched enamel in L Pop. The results obtained suggest the self-etching adhesive did not etch enamel and penetrate into dentinal tubule as deeply as did additional etching. Further research should include the evaluation of the relationship of boding strength, microleakage and resin tag morphology.

  • PDF

The Changes of Defibrillation Time Depending on the Manual External Defibrillator Device (제세동 시행도구에 따른 제세동 지연시간의 변화)

  • Park, Si-Eun;Shin, Dong-Min
    • The Korean Journal of Emergency Medical Services
    • /
    • v.16 no.1
    • /
    • pp.81-90
    • /
    • 2012
  • Objectives: This study is to research delay time comparison for later defibrillation after hands off according to the changes in defibrillation electrodes. Study purpose: In defibrillation treatment that is the only way for cardiac arrest by arrhythmia, it is to find defibrillator device which can minimize late defibrillation delay time after important affect of hands off. Study object and method: After hands off according to the defibrillator device, we collected total 40 people for emergency medicine doctor, internal medicine doctor, general surgeon, nurse, emergency medical technician who are working at 2 CN, CS University hospitals in Gwangju Jeollanamdo district to find out hand off shock interval(HOSI). We then researched their general properties like occupation sector, experiences in clinic, gender, completion of AHA ACLS-P training and more. Then 40 participants continued ventricular fibrillation cardiac arrest simulation training (using human-model mannequin) designed by researcher and performed their roles as defibrillation operator. Each of participant used manual paddle and performed 4 times of defibrillation (150J) during 8 minutes of CPR and in 8day, the defibrillator devices were replaced from manual paddle to self-adhesive electrodes pads and 4 times of defibrillation (150J) under same simulation condition as manual paddle were performed. Study result: In comparison for delay time of later defibrillation after hands off of manual paddle and self adhesive electrodes pad, the self adhesive electrodes pad ($7.0{\pm}0.5sec$) seemed to reduce delay time of later defibrillation significantly (p<0.05) compared to manual paddle ($10.0{\pm}0.9sec$). The self adhesive electrodes pad, according to the general properties of participants, had no particular change in delay time after later defibrillation for the statistics (p>0.05) but the manual paddle had statistically significant differences for the occupation sector, experiences in clinic and gender (p<0.05). Conclusion: In defibrillation, the self adhesive electrodes pad($7.0{\pm}0.5sec$) showed short HOSI compared to manual paddle ($10.0{\pm}0.9sec$) significantly (p<0.05) and it applied identically for both existence and non-existence of ACLS-P training completion, experiences in clinic, gender and occupation sector. The manual paddle had also significant difference in experiences in clinic and occupation sector (p<0.05). which means the effect on HOSI according to the job mastery. Therefore, if the clinic experience is short or in case for the occupations without frequent defibrillation treatment has a danger of lowering success rate for the defibrillation using manual paddle. Therefore, it is true that using self adhesive electrodes pad for defibrillation electrodes when performing manual defibrillation in pre-hospital as well as in-hospital steps can generally minimize delay time of later defibrillation after hands off.

Physical Properties of Different Automixing Resin Cements and the Shear Bond Strength on Dentin (수종 Automixing 레진시멘트의 물성과 상아질에 대한 전단결합강도)

  • Song, Chang-Kyu;Park, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.4
    • /
    • pp.437-444
    • /
    • 2009
  • The purpose of this study was to evaluate the physical properties of different automixing resin cements and the shear bond strength on dentin. For this study, two self-adhesive automixing resin cement(Rely-X Unicem(3M ESPE, St. Paul, USA), Embrace resin cement(Pulpdent, Oakland, USA)) and one chemical polymerizing resin cement(Resiment Ready-Mix(J.L.Blosser Inc., Liberty Missouri, USA)) were used. To evaluate the physical properties, compressive strength, diametral tensile strength and flexural strength were measured. The specimens were fabricated using Teflon mould according to manufacturers' instructions and stored for 24 hours in an atmosphere of 100% humidity. To evaluate the shear bond strength on dentin, each cements were adhered to buccal dentinal surface of extracted human lower molars in 2mm diameter. Physical properties and shear bond strengths were measured using universal testing machine(Z010, Zwick GmbH, Ulm, Germany) at a crosshead speed of 0.5mm/min. The physical properties and shear bond strength of different automixing resin cements were statistically analyzed and compared between groups using One-way ANOVA test and Schffe post-hoc test at the 95% level of confidence. The result shows that chemical polymerizing automixing resin cement represents the relatively higher physical properties and shear bond strength than self-adhesive automixing resin cements.

PHYSICAL PROPERTIES OF DIFFERENT SELF-ADHESIVE RESIN CEMENTS AND THEIR SHEAR BOND STRENGTH ON LITHIUM DISILICATE CERAMIC AND DENTIN (수종의 자가 접착 레진 시멘트의 물성 및 lithium disilicate ceramic과 상아질에 대한 전단결합강도 비교)

  • Shin, Hye-Jin;Song, Chang-Kyu;Partk, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.3
    • /
    • pp.184-191
    • /
    • 2009
  • The purpose of this study was to evaluate the physical properties of different self-adhesive resin cements and their shear bond strength on dentin and lithium disilicate ceramic and compare these result with that of conventional resin cement. For this study, four self-adhesive resin cements (Rely-X Unicem, Embrace Wetbond, Mexcem, BisCem), one conventional resin cement (Rely-X ARC) and one restorative resin composite (Z-350) were used. In order to evaluate the physical properties, compressive strength, diametral tensile strength and flexural strength were measured. To evaluate the shear bond strength on dentin, each cement was adhered to buccal dentinal surface of extracted human lower molars. Dentin bonding agent was applied after acid etching for groups of Rely-X ARC and Z-350. In order to evaluate the shear bond strength on ceramic, lithium disilicate glass ceramic (IPS Empress 2) disks were prepared. Only Rely-X ARC and Z-350 groups were pretreated with hydrofluoric acid and silane. And then each resin cement was adhered to ceramic surface in 2 mm diameter. Physical properties and shear bond strengths were measured using a universal testing machine. Results were as follows 1. BisCem showed the lowest compressive strength, diametral tensile strength and flexural strength. (P<0.05) 2. Self-adhesive resin cements showed significantly lower shear bond strength on the dentin and lithium disilicate ceramic than Rely-X ARC and Z-350 (P<0.05) In conclusion, self-adhesive resin cements represent the lower physical properties and shear bond strength than a conventional resin cement.