• Title/Summary/Keyword: selenium(Se)

Search Result 379, Processing Time 0.027 seconds

A study on optical gain and output-coupling power of selenium vapour laser using isotope helium (헬륨 동위원소를 사용한 셀레늄증기레이저에서의 광이득과 출력틀성에 관한 연구)

  • 최상태
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.2
    • /
    • pp.114-118
    • /
    • 2000
  • The paper presents the effects of outpLlt-coLLpling power and small SIgnal gain of a He-Se+ laser by discharge of either $^4He$ or $^3He$. A quartz plane-plate was installed to outpLlt-coLlple the laseI beam from the resonator in the eAperimental setup. The result shows tbat compared with those of ~He, tbe outPLlt-coupling power and small-signal gain of $^4He$ increase in the most of the lines. EspeCIally, the small-signal gain of $^3He$ for the strong lines (497.6 nm, 499.3 nm, 506.9 urn, 5176 nm, 522.8 mn, 530.5 nm) lies 25% higher than Ulat of 4He, and the output-coupling power doubles oubles

  • PDF

A Study on Heavy Metals and Selenium Contents of Seafoods Commonly Consumed in Gyeonggi-Do (경기도내 유통 다소비 생선류의 중금속 및 셀레늄 함량)

  • Cho, Yun-Sik;Kim, Ki-Cheol;Kim, Kyung-A;Kang, Suk-Ho;Jung, You-Jung;Kwak, Shin-Hye;Lee, Pil-Suk;Lee, Woon-Hyung;Moh, Ara;Yong, Kum-Chan;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.3
    • /
    • pp.211-216
    • /
    • 2017
  • A total of 100 seafoods commonly consumed in Gyeonggi-do were investigated to determine the concentration of lead (Pb), total mercury (Hg), methyl mercury (MeHg), cadmium (Cd) and selenium (Se). Concentration of heavy metals and selenium was measured by using mercury analyzer, ICP-MS and GC-ECD. The average content (mg/kg) of heavy metals in the seafood samples was as follows; Pb 0.0915 (0.0021-0.4490), Cd 0.0084 (ND-0.1773), and Hg 0.0412 (0.0013-0.3032). All the levels were below the recommended standards of the MFDS in Pb (0.5 mg/kg), Cd (0.2 mg/kg), Hg (0.5 mg/kg). The methylmercury was detected in the hairtail (0.0677 mg/kg) and cod (0.2941 mg/kg). After the average content of heavy metals in seafood was determined, the exposure assessment for heavy metals was conducted. Relative hazardous levels compared to PTWI were lower than the official standards of the JECFA for Pb (0.97%), Hg (3.42%) Cd (0.45%). In conclusion, the levels presented in this study are presumed to be safe for consumption.

Transport Properties of Charge Carrier in Amorphous Selenium Converter drived by Vacuum Thermal Evaporation Method (진공증착법을 이용한 비정질 셀레늄 변환체의 전하캐리어 이동특성 분석)

  • Park, Ji-Koon;Choi, Il-Hong;Lee, Mi-Hyun;Lee, Kwang-Phoo;Yu, Haeng-Soo;Jung, Bong-Zae;Kang, Sang-Sik;Kim, Mi-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.4
    • /
    • pp.37-40
    • /
    • 2010
  • In this paper, transport properties of charge carrier which is produced by x-ray exposure were investigated.. It is the research of charge transport and specific property of trap that is performed in direct digital x-ray image receptor. We measured transit time and drift mobility of charge carriers of a-Se photoconductor using time-of-flight method. We made a testing glass with a-Se of $100{\mu}m$ thickness on corning glass using thermal evaporation method. As a result of this experiment, electron and hole transit time was each $229.17{\mu}s$ and $8.73{\mu}s$ at $10V/{\mu}m$ electric field and drift mobility was each $0.00174cm^2/V{\cdot}s$, $0.04584cm^2/V{\cdot}s$. But the results shows us different measurement value of electron and charge drift mobility and it was investigated about charge transport properties and trap mechanism.

Detection Methods of Histochemically-reactive Zinc in the CNS at the Light Microscopical Level (중추신경계통 내 분포하는 zinc 이온의 조직화학적 동정법 비교: I. 광학현미경수준에서)

  • Kim, Yi-Suk;Kim, Sang-Hyun;Lee, Beob-Yi;Lee, Hyun-Sook;Kim, Sung-Joo;Jo, Seung-Mook
    • Applied Microscopy
    • /
    • v.38 no.1
    • /
    • pp.29-34
    • /
    • 2008
  • Small amounts of zinc ions regulate a plentitude of enzymatic proteins, receptors and transcription factors, thus cells need accurate homeostasis of zinc ions. Some neurons have developed mechanisms to accumulate zinc in specific membrane compartment ("vesicular zinc"), which can be evidenced using histochemical techniques. These neurons are the socalled zinc enriched (ZEN) neurons, which accumulate glutamate and zinc inside their synaptic vesicles and release it during synaptic transmission. In the present paper we have studied the distribution of the ZEN terminals in the rat hippo-campus using ZnSe autometallography, Neo-Timm staining, ZnT3 immunohistochemistry and TSQ fluorescence staining.

Variation of Urinary and Serum Trace Elements (Ca, Zn, Cu, Se) in Bladder Carcinoma in China

  • Guo, Kun-Feng;Zhang, Zhe;Wang, Jun-Yong;Gao, Sheng-Lin;Liu, Jiao;Zhan, Bo;Chen, Zhi-Peng;Kong, Chui-Ze
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.5
    • /
    • pp.2057-2061
    • /
    • 2012
  • Backgrounds: Deficiency or excess of trace elements can induce body metabolic disorders and cellular growth disturbance, even mutation and cancerization. Since there are few studies of the effect of trace elements in bladder carcinoma in China, the aim of this study was thus to assess variation using a case control approach. Methods: To determine this, 81 patients with bladder carcinoma chosen as a study group and 130 healthy persons chosen as a control group were all assayed for urinary and serum trace elements (calcium [Ca], zinc [Zn], copper [Cu], selenium [Se]) using an atomic absorption spectrophotometer, and the results were analyzed by independent sample t tests. The correlative factors on questionnaires answered by all persons were analyzed by logistic regression. Results: The results showed urinary Ca, Zn and serum Cu levels of the study group to be significantly higher (P<0.05) than those of he control group. Serum Ca and Se levels of study group were significantly lower (P<0.05) than those of control group. Conclusion: There were higher urinary Zn and serum Cu concentrations in bladder carcinoma cases. Bladder carcinoma may be associated with Ca metabolic disorder, leading to higher urinary Ca and lower serum Ca. Low serum Se and smoking appear to be other risk factors for bladder carcinoma in China.

Linear Source for Evaporating Large Area CIGS Absorber Layer (대면적 CIGS 광흡수층 증착을 위한 선형증발원 개발)

  • Seo, J.H.;Jung, S.W.;Lee, W.S.;Choi, Y.S.;Choi, M.W.;Choi, J.C.;Jeong, K.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.1
    • /
    • pp.1-6
    • /
    • 2013
  • In this paper, to develop linear source for evaporating $600{\times}1,200mm$ size of large area CIGS absorber layer, we simulated linear thermal source and obtained ${\pm}5%$ thickness uniformity with various nozzle sizes and regular nozzle distance. Flux density was confirmed linear source length. Using this linear source, we tested thickness uniformity of Copper, Indium single layer which was obtained Cu ${\pm}5%$ and In ${\pm}5%$ thickness uniformity. And then CIGS absorber layers were evaporated with In-line single-stage co-evaporation. Large area CIGS absorber layers were confirmed composition uniformity of $$Cu{\leq_-}5%$$, $$In{\leq_-}7%$$, $$Ga{\leq_-}4%$$, $$Se{\leq_-}3%$$ with 600 mm width by XRF. Uniform shape of CIGS absorber layers was confirmed by SEM. XRD showed peaks which indicate chalcopyrite structure of CIGS absorber layers. Thus, developed linear source is suitable for evaporating CIGS absorber layer.

Determination of Antioxidants Contents in Various Plants Used as Tea Materials (다류소재 식물류 중의 황산화물질 함량 분석)

  • Kim, Mee-Hye;Kim, Myung-Chul;Park, Jong-Seok;Park, Eun-Ji;Lee, Jong-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.273-279
    • /
    • 1999
  • Forty plants used as tea materials were chosen for determining the contents of total phenolics, selenium (Se), ${\beta}-carotene$, ${\alpha}-tocopherol$ and ascorbate. Total phenolics and ascorbate contents were analyzed colorimetrically. The Se contents were measured by hydride-atomic absorption spectrometry. The contents of ${\beta}-carotene$ and ${\alpha}-tocopherol$ were simultaneously determined by high performance liquid chromatography using separate detectors, UV for ${\beta}-carotene$ and FL for ${\alpha}-tocopherol$ analyses. The contents of these antioxidants were as follows (per 100 g dry plant); Contents of total phenolics in green tea leaf, black tea leaf, oolong tea leaf and instant coffee were about 7 g and the Se contents in corni fructus and arrowroot were found to be about $4{\mu}g$, which were the highest among all plants used. Contents of ${\beta}-carotene$ in eucommiae cortex, persimmon leaf and green tea leaf were 8587, 6222 and $3652\;{\mu}g$ respectively. The persimon leaf contained the highest ${\alpha}-tocopherol$ content (33 mg) and then followed by eucommiae cortex (26 mg), green tea leaf (16 mg) and black tea leaf (13 mg) in order. Ascorbate contents were found to be high in green tea leaf (199 mg) and black tea leaf (117 mg).

  • PDF

Chimie Douce Synthesis of Chalcogen-Doped Manganese Oxides (칼코겐이 도핑된 망간 산화물의 저온합성 연구)

  • Hwang, Seong-Ju;Im, Seung-Tae;Park, Dae-Hun;Yun, Yeong-Su
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.4
    • /
    • pp.315-320
    • /
    • 2006
  • manganese oxides have been prepared by Chimie Douce redox reaction between permanganate and chalcogen element fine powder under acidic condition (pH = 1). According to powder X-ray diffraction analyses, the S- and Se-doped manganese oxides are crystallized with layered birnessite and tunnel-type -MnO2 structures, respectively. On the contrary, Te-doped compound was found to be X-ray amorphous. According to EDS analyses, these compounds contain chalcogen dopants with the ratio of chalcogen/manganese = 4-7%. We have investigated the chemical bonding character of these materials with X-ray absorption spectroscopic (XAS) analysis. Mn K-edge XAS results clearly demonstrated that the manganese ions are stabilized in octahedral symmetry with the mixed oxidation states of +3/+4. On the other hand, according to Se K- and Te L1-edge XAS results, selenium and tellurium elements have the high oxidation states of +6, which is surely due to the oxidation of neutral chalcogen element by the strong oxidant permanganate ion. Taking into account their crystal structures and Mn oxidation states, the obtained manganese oxides are expected to be applicable as electrode materials for lithium secondary batteries.

Effects of functional nutrients on chicken intestinal epithelial cells induced with oxidative stress

  • Hyun Woo Kim;Seung Yun Lee;Sun Jin Hur;Dong Yong Kil;Jong Hyuk Kim
    • Journal of Animal Science and Technology
    • /
    • v.65 no.5
    • /
    • pp.1040-1052
    • /
    • 2023
  • The objective of this study was to investigate the protective effects of functional nutrients including various functional amino acids, vitamins, and minerals on chicken intestinal epithelial cells (cIECs) treated with oxidative stress. The cIECs were isolated from specific pathogen free eggs. Cells were exposed to 0 mM supplement (control), 20 mM threonine (Thr), 0.4 mM tryptophan (Trp), 1 mM glycine (Gly), 10 μM vitamin C (VC), 40 μM vitamin E (VE), 5 μM vitamin A (VA), 34 μM chromium (Cr), 0.42 μM selenium (Se), and 50 μM zinc (Zn) for 24 h with 6 replicates for each treatment. After 24 h, cells were further incubated with fresh culture medium (positive control, PC) or 1 mM H2O2 with different supplements (negative control, NC and each treatment). Oxidative stress was measured by cell proliferation, whereas tight junction barrier function was analyzed by fluorescein isothiocyanate (FITC)-dextran permeability and transepithelial electrical resistance (TEER). Results indicated that cell viability and TEER values were less (p < 0.05) in NC treatments with oxidative stress than in PC treatments. In addition, FITC-dextran values were greater (p < 0.05) in NC treatments with oxidative stress than in PC treatments. The supplementations of Thr, Trp, Gly, VC, and VE in cells treated with H2O2 showed greater (p < 0.05) cell viability than the supplementation of VA, Cr, Se, and Zn. The supplementations of Trp, Gly, VC, and Se in cells treated with H2O2 showed the least (p < 0.05) cellular permeability. In addition, the supplementation of Thr, VE, VA, Cr, and Zn in cells treated with H2O2 decreased (p < 0.05) cellular permeability. At 48 h, the supplementations of Thr, Trp, and Gly in cells treated with H2O2 showed the greatest (p < 0.05) TEER values among all treatments, and the supplementations of VC and VE in cells treated with H2O2 showed greater (p < 0.05) TEER values than the supplementations of VA, Cr, Se, and Zn in cells treated with H2O2. In conclusion, Thr, Trp, Gly, and VC supplements were effective in improving cell viability and intestinal barrier function of cIECs exposed to oxidative stress.

Radiation detector material development with multi-layer by hetero-junction for the reduction of leakage current (헤테르접합을 이용한 누설전류 저감을 위한 다층구조의 방사선 검출 물질 개발)

  • Oh, Kyung-Min;Yoon, Min-Seok;Kim, Min-Woo;Cho, Sung-Ho;Nam, Sang-Hee;Park, Ji-Goon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.1
    • /
    • pp.11-15
    • /
    • 2009
  • In this study, the basic research verifying possibility of applications as radiology image sensor in Digital Radiography was performed, the radiology image sensor was fabricated using a multi-layer technique to decrease dark current. High efficiency materials in substitution for Amorphous Selenium(a-Se) have been studied as a direct method of imaging detector in Digital Radiography to decrease dark current by using PN junction or Hetero junction already used as solar cell, semiconductor. Particle-In -Binder method is used to fabricate radiology image sensor because it has a lot of advantages such as fabrication convenient, high yield, suitability for large area sensor. But high leakage current is one of main problem in Particle-In -Binder method. To make up for the weak points, multi-layer technique is used, and it is considered that high efficient digital radiation sensor can be fabricated with easy and convenient process. In this study, electrical properties such as leakage current, sensitivity, signal linearity is measured to evaluate multi-layer radiation sensor material.

  • PDF