• Title/Summary/Keyword: selected reaction monitoring(SRM)

Search Result 10, Processing Time 0.022 seconds

Analysis of clenbuterol in bovine muscle and milk by LC-ESI/MS/MS (LC-ESI/MS/MS를 이용한 소고기와 우유에서의 클렌부테롤 분석)

  • Hong, Selyung;Jeong, Jiyoon;Park, Hyejin;Lee, Soonho;Lee, Jongok
    • Analytical Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.535-542
    • /
    • 2008
  • A liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI/MS/MS) method was developed for the determination and confirmation of clenbuterol in bovine muscle and milk. Clenbuterol and clenbuterol-D9 using as an internal standard in samples were extracted with ethyl acetate after hydrolysis and evaporated to dryness. The extracts were dissolved in 20% methanol and cleaned using HLB solid-phase extraction cartridge. The analytes were detected by LC-ESI/MS/MS on a $C_{18}$ column. Mass spectral acquisition was done in selected reaction monitoring (SRM) in positive ion mode to provide a high degree of sensitivity. Using MS/MS with SRM mode, the transitions (precursor to product) monitored were m/z 277${\rightarrow}$203 for clenbuterol, and m/z 286${\rightarrow}$204 for internal standard. The limits of quantitation (LOQ) and mean recoveries of clenbuterol in bovine muscle were $0.2{\mu}g/kg$ and 84.3~91.1%, respectively. The LOQ and mean recoveries in milk were $0.05{\mu}g/kg$ and 87.7~98.3%, respectively.

Accurate determination of chloramphenicol in meat by isotope dilution liquid chromatography mass spectrometry (ID-LC/MS) (동위원소희석 액체크로마토그래피-질량분석법을 이용한 육류 중 클로람페니콜의 정밀한 정량 분석에 관한 연구)

  • Song, Hye-Min;Kim, Byung-Joo;Jeong, Hyuk;Ahn, Seong-Hee
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.524-530
    • /
    • 2010
  • Chloramphenicol is one of the most effective antibiotics for treatment of food-producing animals for typhoid fever. However, it has been reported that it caused severe side effects such as aplastic anemia in human, therefore the use of chloramphenicol for food-producing animal is prohibited by European Union and other countries. In this study, the analytical method using isotope dilution liquid chromatography-mass spectrometry (ID-LC/MS) was established for accurate determination of chloramphenicol in meat. Chloramphenicol was extracted with ethylacetate from porcine and solid phase extraction cartridge was used for enhancing the recovery. The residue of chloramphenicol in porcine was analyzed using the liquid chromatography mass spectrometer (LC/MS) interfaced with electrospray ionization source. Analysis was performed in negative mode with selected reaction mornitoring mode at m/z 321${\rightarrow}$257 of $[M-H]^-$ ${\rightarrow}$ $[M-H-(HCOCl)]^-$ and m/z 326 ${\rightarrow}$ 262 channels for its isotope. The established method was tested using fortified samples at the level of 0.2 1, 10, $25\;{\mu}g$/kg and analytical results agreed with the gravimetrically fortified values within their uncertainties. This method was validated by analyzing a certified reference material, BCR 445, from IRMM (Institute for Reference Materials and Measurement). Our measurement values agreed with the certified value within their uncertainties. The uncertainty of our measured value was much lower than that the certified value from IRMM.

Development of an Isotope-Dilution Liquid Chromatography/Mass Spectrometric Method for the Accurate Determination of Acetaminophen in Tablets

  • Shin, Hyun-Ju;Kim, Byung-Joo;Lee, Joon-Hee;Hwang, Eui-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.12
    • /
    • pp.3663-3667
    • /
    • 2010
  • Acetaminophen (N-acetyl-p-aminophenol) is one of the most popular analgesic and antipyretic drugs. An isotope dilution mass spectrometric method based on LC/MS was developed as a candidate reference method for the accurate determination of acetaminophen in pharmaceutical product. After spiking an isotope labeled acetaminophen (acetyl-$^{13}C_2$, $^{15}N$-acetaminophen) as an internal standard, tablet extracts were analyzed by LC/MS in a selected reaction monitoring (SRM) mode to detect ions at m/z $152{\rightarrow}110$ and m/z $155{\rightarrow}111$ for acetaminophen and acetyl-$^{13}C_2$, $^{15}N$-acetaminophen, respectively. The repeatability and reproducibility of the developed ID/LC-MS method were tested for the validation and assessment of metrological quality of the method.

Simultaneous Liquid Chromatography Tandem Mass Spectrometric Determination of 35 Prohibited Substances in Equine Plasma for Doping Control

  • Kwak, Young Beom;Yu, Jundong;Yoo, Hye Hyun
    • Mass Spectrometry Letters
    • /
    • v.13 no.4
    • /
    • pp.158-165
    • /
    • 2022
  • Many therapeutic class drugs such as beta-blocker, corticosteroids, NSAIDs, etc are prohibited substances in the horse racing industry. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology makes it possible to isolate drugs from interference, enables various drug analyses in complex biological samples due to its sensitive sensitivity, and has been successfully applied to doping control. In this paper, we describe a rapid and sensitive method based on solid-phase extraction (SPE) using solid phase cartridge and LC-MS/MS to screen for different class's 35 drug targets in equine plasma. Plasma samples were pretreated by SPE with the NEXUS cartridge consisted non-polar carbon resin and minimum buffer solvent. Chromatographic separation of the analytes was performed on ACQUITY HSS C18 column (2.1 × 150 mm, 1.8 ㎛). The elution gradient was conducted with 5 mM ammonium formate (pH 3.0) in distilled water and 0.1% formic acid in acetonitrile at a flow rate of 0.25 mL/min. The selected reaction monitoring (SRM) mode was used for drug screening with multiple transitions in the positive ionization mode. The specificity, limit of detection, recovery, and stability was evaluated for validation. The method was found to be sensitive and reproducible for drug screening. The method was applied to plasma sample analysis for the proficiency test from the Association of Racing Chemist.

Development of Isotope Dilution LC-MS/MS Method for Accurate Determination of Arsenobetaine in Oyster Certified Reference Material

  • Lee, Woo Young;Yim, Yong-Hyeon;Hwang, Euijin;Lim, Youngran;Kim, Tae Kyu;Lee, Kyoung-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.3
    • /
    • pp.821-827
    • /
    • 2014
  • An isotope dilution liquid chromatography tandem mass spectrometry (ID LC-MS/MS) method has been developed and applied to the determination of arsenobetaine (AsB, ${(CH_3)_3}^+AsCH_2COO^-$) from oyster candidate certified reference material (CRM). The exact matching isotope dilution approach was adopted for accurate determination of AsB using $^{13}C_2$-labeled AsB as an internal standard. Efficiencies of different AsB extraction methods were evaluated using a codfish reference material and a simple sonication method was selected as the method of choice for the certification of the oyster candidate CRM. The hydrophilic interaction liquid chromatography (HILIC) combined with electrospray ionization tandem mass spectrometry (ESI/MS/MS) in selected reaction monitoring (SRM) mode was optimized for adequate chromatographic retention and robust quantification of AsB from codfish and oyster samples. By analyzing 12 subsamples taken from each 12 bottles systematically selected from the whole oyster CRM batch, the certified value of AsB was determined as $6.60mg{\cdot}kg^{-1}{\pm}0.31mg{\cdot}kg^{-1}$ and it showed excellent between-bottle homogeneity of less than 0.42%, which is represented by relative standard deviation of 12 bottles from the CRM batch. The major source of uncertainty was the certified value of the AsB standard solution.

Determination of Veterinary Antibiotic Residues: III. Analytical Methods_A Review (시료 중 잔류 항생제 분석 방법: III. 기기 분석 방법)

  • Kim, Chansik;Ryu, Hong-Duck;Chung, Eu Gene;Kim, Yongseok;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.649-669
    • /
    • 2016
  • This study explored the analytical conditions for 21 veterinary antibiotics which have been popularly sold in South Korea in 2014 but have not yet been targeted in EPA method 1694. Most of the selected antibiotics were separated by a reverse-phase C18 column with a combination of (buffered) water and organic polar solvent, which was commonly methanol and acetonitrile in the gradient elution mode. Volatile additives such as formic acid, ammonium acetate and ammonium formate were usually added to the mobile phases to minimize asymmetrical and tailing of antibiotics' peaks and to increase their ionization in mass spectrometry. The analytical methods of aminoglycoside antibiotics were distinct from those of the other antibiotics in terms of adoption of ion-pair chromatography (IPC) and hydrophilic interaction liquid chromatography (HILIC) capable of retaining and separating extremely polar compounds due to their hydrophilicity. Trifluoroacetic acid or heptafluorobutyric acid was frequently added to the mobile phase as an ion-pair reagent for the IPC. Tandem mass spectrometry was numerously applied to the detection of antibiotics using positive electrospray ionization (ESI) and the selected reaction monitoring (SRM) mode. All reviewed analytical methods had been/were validated by evaluating recovery, limits of detection and quantification, decision limit or detection capability of the methods.

Analysis of sorbic acid in tea-drink using isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS) (동위원소희석 액체 크로마토그래피-질량분석법을 이용한 차음료 중의 소르빈산의 분석)

  • Ahn, Seong-Hee;Lee, In-Sun;Kim, Byung-Joo
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.25-32
    • /
    • 2012
  • Isotope dilution mass spectrometry (ID-MS) based on liquid chromatography tandem mass spectrometry (LC/MS/MS) was developed for the accurate determination of sorbic acid in tea-drink. An isotope analogue of sorbic acid, $^{13}C_2$-sorbic acid, was obtained by custom synthesis. MS was operated in the negative mode with selected reaction monitoring (SRM) mode of $[M-H]^-$ ${\rightarrow}$ $[M-CO_2H]^-$ channel at m/z 111 ${\rightarrow}$ 67 for sorbic acid and at m/z 113 ${\rightarrow}$ 68 for its isotope analogue. Chromatographic separation was accomplished with a C18 column and an isocratic mobile phase of 55% of 50 mM ammonium acetate (pH 4.5) and 45% of methanol. Homogeneous reference materials were prepared for validation of this method, including repeatability and reproducibility tests, by fortifying tea-drink with sorbic acid in our laboratory. Repeatability and reproducibility studies showed that the ID-LC/MS method is a reliable and reproducible method which provides less than 3.8% of relative standard deviation (RSD) for the analysis of sorbic acid.

An analysis of benzoic acid, methyl paraben and butyl paraben in soy sauce using isotope dilution liquid chromatography mass spectrometry (동위원소희석 질량분석법을 이용한 간장 중의 안식향산, 메틸파라벤, 부틸파라벤의 분석)

  • Ahn, Seonghee
    • Analytical Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.225-231
    • /
    • 2018
  • Benzoic acid, methyl paraben, and butyl paraben are preservatives that have been used in pharmaceutical, cosmetic, and food products. However, as their toxicities for human have been reported, many nations and organizations including Korea have established a regulation limit for thier usage of these preservatives in food products. The present study developed the isotope dilution liquid chromatography mass spectrometry method for accurate determination of three target preseratives in soysauce. In this study, the isotope dilution liquid chromatography mass spectrometry method was developed for accurate determination of three target preservatives in soy sauce. LC separation was optimized considering the pKa of benzoic acid which is lower than those of methyl and butyl parabens. A C18 column was used with 5 mM ammonium acetate and methanol as mobile phases. Mass spectrometry was operated in negative mode and selected reaction monitoring mode (SRM). Soy sauce sample was cleaned-up with C18 SPE cartridge for removing matrix inferences and color material. Optimized conditions and the method were validated with soy sauce reference materials for the analysis of food preservatives from Health Science Authority in Singapore. The measured values of benzoic acid, methyl and butyl paraben agreed well with reference values within their uncertainties.

Ultra-fast Generic LC-MS/MS Method for High-Throughput Quantification in Drug Discovery

  • Kim, So-Hee;Yoo, Hye Hyun;Cha, Eun-Ju;Jeong, Eun Sook;Kim, Ho Jun;Kim, Dong Hyun;Lee, Jaeick
    • Mass Spectrometry Letters
    • /
    • v.4 no.3
    • /
    • pp.47-50
    • /
    • 2013
  • An ultra-fast generic LC-MS/MS method was developed for high-throughput quantification of discovery pharmacokinetic (PK) samples and its reliability was verified. The method involves a simple protein precipitation for sample preparation and the analysis by ultra-fast generic LC-MS/MS with the ballistic gradient program and selected reaction monitoring (SRM) mode. Approximately 290 new chemical entities (NCEs) (over 10,000 samples) from 5 therapeutic programs were analyzed. The calibration curves showed good linearity in the concentration range of 1, 2 or 5 to 2000 ng/mL. No significant ion suppression was observed in the elution region of all the NCEs. When approximately 300 plasma samples were continuously analyzed, the peak area of internal standard was constant and reproducible. In the repeated analysis of samples, the plasma concentrations and the area under the curve (AUC) were consistent with the results from the first analysis. These results showed that the present ultra-fast generic LC-MS/MS method is reliable in terms of selectivity, sensitivity, and reproducibility and could be useful for high-throughput quantification and other bioanalysis in drug discovery.

Development and Validation of an Analytical Method for Glucuronolactone in Energy Drinks by Hydrophilic Interaction Liquid Chromatography-electrospray Tandem Mass Spectrometry

  • Oh, Mi Hyune;Lim, Moo Song;Chai, Jeung Young;Kim, Eun Jung;Cho, Joong Hoon;Lim, Chul Joo;Choi, Sun Ok
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.2
    • /
    • pp.89-95
    • /
    • 2017
  • A rapid, sensitive analytical method for glucuronolactone in beverages was developed and validated using hydrophilic interaction liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HILIC-ESI-MS/MS). To determine the optimum analytical conditions for glucuronolactone, three different kinds of HILIC columns and two mobile phases with different pH values were examined. An amide-bonded stationary phase with a pH 9 acetonitrile-rich mobile phase was the best condition in terms of column retention, ESI-MS/MS response area, and signal-to-noise ratio. After extraction, glucuronolactone was separated through the HILIC amide column and detected by negative ESI-MS/MS in selected reaction monitoring (SRM) mode. Nine energy drinks sold in Korea were spiked with glucuronolactone at a concentration of 5 ng/mL; the Monster $Energy^{TM}$ sample showed the smallest peak area and its signal-to-noise ratio was used for method validation. Good linearity was obtained in the concentration range from 20 to 1500 ng/mL with a correlation coefficient > 0.998. The developed method had a limit of detection (LOD) of 6 ng/mL and a limit of quantitation (LOQ) of 20 ng/mL. The recovery of this method at concentration of 20, 100, 500, and 1000 ng/mL was 96.3%-99.2% with relative standard deviations (RSD) of 1.6%-14.0%. A reproducibility precision assessment at concentration of 100 and 500 ng/mL was carried out among three laboratories. The recovery of that evaluation was 95.1%-102.3% with RSD of 2.7%-7.0%. An analysis of variance indicated that there was no difference between the recovery results of the three laboratories at the 5% significance level. The validated method is applicable to inspecting beverages adulterated with glucuronolactone in Korea.