• Title/Summary/Keyword: selected ion monitoring(SIM)

Search Result 109, Processing Time 0.023 seconds

Determination of 11 Phenolic Endocrine Disruptors using Gas Chromatography/Mass Spectrometry-Selected Ion Monitoring in Five Selected Wastewater Influents

  • Kim, Hyub
    • Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.216-223
    • /
    • 2008
  • An efficient method for the simultaneous determination of eleven phenolic endocrine-disrupting chemicals (EDCs) present in wastewater influent samples was described. The 11 phenolic EDCs including alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring (GC/MS-SIM) following two work-up methods for comparison; isobutoxycarbonyl (isoBOC) derivatization and tert-butyldimethylsilyl (TBDMS) derivatization. The wastewater influent samples containing the 11 EDCs were adjusted to pH 2 with $H_2SO_4$ and then cleaned up with n-hexane. Next, they were subjected to solid-phase extraction (SPE) with XAD-4 resin and subsequently converted to isoBOC or TBDMS derivatives for sensitivity analysis with gas chromatography/mass spectrometry-selected ion monitoring (GC/MSSIM). Following isoBOC derivatization and TBDMS derivatization, the recoveries were 86.6-105.2% and 97.6-142.7%, the limits of quantitation (LOQ) for the 11 phenolic EDCs for SIM was 0.001-0.050 ng/mL and 0.003-0.050 ng/mL, and the SIM responses were linear with the correlation coefficient varying by 0.9717-0.9995 and 0.9842-0.9980, respectively. When these methods were applied to five selected wastewater influent samples, for isoBOC derivatization and TBDMS derivatization the ranges of concentration detected were 0.2-99.6 ng/mL and 0.4-147.4 ng/mL, respectively.

Comparative Studies on Two Types Derivatives of Gibberellins for the Gibberellin Analysis by Gas Chromatography-Selected Ion Monitoring (GC-SIM에 의한 두종의 gibberellin유도체의 분석)

  • Park, Keun-Hyung
    • Applied Biological Chemistry
    • /
    • v.28 no.2
    • /
    • pp.82-87
    • /
    • 1985
  • Aiming at the improvement of accuracy and sensitivity of gibberellin analysis by gas chromatography-selected ion monitoring (GC-SIM), the mass spectra of two types of 29 gibberellin derivatives, methyl ester-trimethylsilyl ethers and trimethylsilyl ester-trimethylsilyl ethers, were obtained and their advantages and disadvantages in GC-SIM analysis are discussed.

  • PDF

GC/MS and GC/ECD Analysis of Residual Pesticides in Herbal drugs (GC/MS와 GC/ECD를 이용한 한약재 중 잔류 농약의 분석)

  • Kim, Ho-Kyoung;Park, So-Yeon;Ko, Byoung-Seob
    • The Journal of Korean Medicine
    • /
    • v.20 no.1 s.37
    • /
    • pp.44-51
    • /
    • 1999
  • Analysis of residual pesticides in herbal drugs was performed by GC-ECD and GC-MS. Especially, selected ion monitoring(SIM) technique was applied to increase the GC/MS sensitivity. Analysis of residual pesticides was determined sensitivity and selectively without any internal standard by setting the SIM technique to their characteristic fragments for quantitation ion and confirmation ion. The combination of two detector, GC-ECD and MS-SIM technique, is abailable for determining a multiclass residual pesticides in herbal drugs. The average recoveries through the method were $65.9%{\sim}99.7%$ in herbal drugs. The data of gas chromatographic analysis was compared with the limits of residual pesticides in herbal drugs and agricultural foods. 4. 4-DDT was detected above the limits to the residual pesticides in herbal drugs. Diazinon and EPN were detected, but the limits of residual pesticides were less than that of agricultural foods.

  • PDF

Analysis of Residual Pesticides in Herbal Drugs: GC/MS Analysis of 27 Controlled Pesticides (생약 중 잔류 농약의 분석법: GC/MS에 의한 27종 잔류 규제 농약의 분석)

  • Park, Man-Ki;Park, Jeong-Hill;Yoon, Hye-Ran;Yoon, In-Byoung;Cho, Sool-Yeon;Hwang, Gwi-Seo
    • YAKHAK HOEJI
    • /
    • v.40 no.2
    • /
    • pp.141-148
    • /
    • 1996
  • GC/MS analysis of 27 controlled pesticides in herbal drugs was studied. Selected ion monitoring(sim) technique was applied to increase the GC/MS sensitivity. Typical peaks in th e mass spectrum of each pesticides were selected as quantitation, comfirmation or alternate ion. Twenty seven pesticides were divided into five groups according to their retention time and the peaks for SIM were programmed accordingly. The combination of two ionization methods, electron impact(EI)-SIM-MS and negative ion chemical ionization(NCI)-SIM-MS, were well-fitted for the detection, confirmation and quantitation of multiclass residual pesticides in herbal drugs.

  • PDF

Analysis of Benzophenone in Sediment and Soil by Gas Chromatography/Mass Spectrometry (기체크로마토그래피/질량분석기에 의한 저질 및 토양시료 중 벤조페논의 분석법 연구)

  • 권오승;김은영;류재천
    • Environmental Analysis Health and Toxicology
    • /
    • v.16 no.3
    • /
    • pp.121-126
    • /
    • 2001
  • Analytical method of benzophenone (BP) in sediment and soil was developed by gas chromatography/mass selective detector/selected ion monitoring (GC/MSD/SIM). The ultrasonic extraction of US EPA (method 3550B) method and liquid-liquid extraction for sediment and soil samples were used for the analysis of BP from sediment and soil. BP was extracted with n-hexane. Organic layer was washed with 5% sodium chloride solution. 1∼2 l of the concentrated solution of organic layer was applied to GC/MSD. The retention time of BP peak was 11.10 min. Recovery (%) of BP by ultrasonication from sediment and soil samples was 96.0∼100.6% and 40.0∼83.0%, respectively. Recovery of BP by liquid-liquid extraction was 51∼59% in soil samples. The detection limit of BP in sediment and soil samples were determined to 0.1 ng/g.

  • PDF

Simultaneous Analysis of Semi-Volatile Organic Base/Neutral Priority Pollutants in Soil (토양 중의 비휘발성 염기/중성 유기 Priority Pollutants 동시 분석에 관한 연구)

  • Lee, Seung Seok;Park, Gyo Beom;Lee, Seok Geun
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.6
    • /
    • pp.418-426
    • /
    • 1994
  • This study was aimed at the detection of 40 semi-volatile organic base/neutral compounds from soil among 129 priority pollutants listed by EPA. Two extraction procedures, sonication extraction and Soxhlet extraction, were studied as a extraction and concentration method for priority pollutants in soil. Extracts were analyted by GC/MS-SIM(selected ion monitoring). The analytical methods were tested by standard compounds spiked into blank soil. Accuracy and precision of the methods were measured by calculation of mean recovery and mean relative standard deviation. And the method detection limits were estimated.

  • PDF

Simultaneous Analysis of Semi-Volatile Organic Acid Priority Pollutants in Soil (토양 중의 비휘발성 산성 유기 Priority Pollutants 동시분석에 관한 연구)

  • Lee, Seung Seok;Park, Gyo Beom;Lee, Seong Geun
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.3
    • /
    • pp.246-253
    • /
    • 1994
  • The simultaneous analysis of 11 semi-volatile organic acid compound which are listed as priority pollutants by EPA, were performed by GC/MS-SIM(selected ion monitoring). Two extraction procedures, sonication extraction and Soxhlet extraction, were studied as an extraction and concentration method for priority pollutants in soil. Accurecy and precision of the methods were measured by the calculation of mean recovery, mean relative standard deviation, and method detection limit. Finally, limitations and prospects were discussed.

  • PDF

Analysis of Ginsenosides by Thermospray LC/MS (열분무 LC/MS에 의한 인삼사포닌의 분석)

  • Park, Man-Ki;Park, Jeong-Hill;Hwang, Gwi-Seo;Lee, Mi-Young;Park, In-Jeong
    • Journal of Ginseng Research
    • /
    • v.19 no.2
    • /
    • pp.134-137
    • /
    • 1995
  • Ginseng saponins were analyzed by thermospray (TSP) LCMS method using ODS column and with acetonitrile/ammonium acetate solution. Optimal condition for TSP Lchfs was found as follows: capillary temperature: 33$0^{\circ}C$ repelled voltage: 200 V, and concentration of ammonium acetate: 0. 05 M. Panaxadiol and panaxatriol type saponins showed characteristic fragment ions. The calibration curve of ginseng saponin showed good linearity with a correlation coefficient of 0.99. Detection limits using selected ion monitoring (SIM) technique were improved by 10~200 times compared to conventional HPLCnnr detection method.

  • PDF

Sensitive Determination of Alkylphenols, Chlorophenols, and Bisphenol A using GC/MS-SIM in Paper Materials (기체 크로마토그래피/질량분석기를 이용한 종이류 중 알킬페놀류, 클로로페놀류 및 비스페놀 A 정량)

  • Kim, Hyub;Kim, Jin-Ho
    • Environmental Analysis Health and Toxicology
    • /
    • v.18 no.1
    • /
    • pp.45-55
    • /
    • 2003
  • The alkylphenols, chlorophenols and bisphenol A were determined by gas chromatography/mass spectrom-etry-selected ion monitoring (GC/MS-SIM) mode followed by two work-up methods for comparison; isoBOC derivatization method and TBDMS derivatization method. Eleven phenols in paper samples were extracted with acetonitrile. Also, solid -phase extraction (SPE) with XAD -4 and subsequent conversion to isobutoxycarbonyl derivatives or tert.-butyldimethylsilyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The SIM responses were linear with the correlation coefficient varying 0.9717 ∼ 0.9995 (isoBOC derivatization), and 0.9842 ∼ 0.9980 (TBDMS derivatization). The recoveries were 82.4 ∼ 108.8%) by area ratio of phenanthrene -d$\_$10/ vs bisphenol A-d$\^$l6/. (isoBOC derivatization and TBDMS derivatization) The range of concentrations was respectively, 0.95 ∼ 1.44 ng/g in 2,4-dichlorophenol, 1.01 ∼ 1.17 ng/g in t-butylphenol,2.17 ∼ 5.84 ng/g in pentachlorophenol, 12.68 ∼ 14.88 ng/g in nonylphenol and 30.84 ∼ 153.72 ng/g in bisphenol A.

Application and Optimization of the IsoButoxycarbonyl Derivatization method to the Analysis of Trace Level Phenols in Environmental Samples (환경시료로부터 미량 페놀류의 분석을 위한 isoButoxycarbonyl 유도체화 분석방법 적용 및 최적화)

  • Kim, Hyub;Hong, Jong-Ki;Kim, Yong-Hwa;Kim, Kyoung-Rae
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.1
    • /
    • pp.37-51
    • /
    • 2002
  • Eleven phenols including two chlorophenols, eight alkylphenols and bisphenol A were derivatized with isobutylchloroformate to form their isobutoxycarbonyl derivatives. Standard phenol mixture was concentrated for the isobutoxycarbonyl (isoBOC) derivatization and analysed by gas chromatography/mass spectrometry (GC/MS). The recoveries of the derivatization method of alkylphenols, chlorophenols, and bisphenol A were calculated by gas chromatography/mass spectrometry-selected ion monitoring mode using two work-up methods for comparison; shaking and heating method. The linear detector responses were obtained in the concentration range of 5∼400 ng, with correlation coefficients varying from 0.9755∼0.9981. Recoveries of the alkylphenols, chlorophenols, and bisphenol A were determined by gas chromatography/mass spectrometry-selected ion monitoring mode using two work-up methods for comparison ; the US-EPA method and the isoBOC derivatization method, Eleven phenols in water samples were extracted with dichloromethane and then concentrated. Also, solid-phase extraction (SPE) with XAD-4 and subsequent conversion to isobutoxycarbonyl derivatives for sensitive analysis with the selected ion-monitoring (SIM) mode. The recoveries were 85.1∼109.9% and 90.3∼126.6% for the US-EPA method and the isoBOC.