• Title/Summary/Keyword: seismic resistance

Search Result 462, Processing Time 0.023 seconds

Study of Seismic Resistance Performance Evaluation Method for Existing Mid-Low Story RC Structure Buildings by Applying Fuzzy Theory (퍼지이론을 적용한 기존 중저층 철근콘크리트 건축물의 내진성능평가기법 연구)

  • Kim, Dong-Hee;Kim, Hyun-Su
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.2
    • /
    • pp.53-62
    • /
    • 2017
  • This study aims to establish a seismic resistance performance evaluation method that makes sure to secure the seismic resistance performance of the existing mid-low story reinforced concrete structures. This study focuses on the development of the seismic resistance performance evaluation method for the overall seismic resistance performance evaluation on the buildings by applying fuzzy theory. This seismic resistance performance evaluation method considers the mutual relations among the type of force, the type of member, the type of story, and the states of deterioration of the buildings. The total seismic resistance performance index from this method was calculated by the intensity weight of each evaluation item, fuzzy measure, fuzzy integration. Moreover, the evaluation methodology was established in this study to identify the performance level of the Immediate Occupancy, Life Safe, Collapse Prevention by applying the fuzzy theory.

A Study on the Current State of Seismic-Resistance and the Feature of Seismic Performance in School Buildings (학교건축물의 내진현황과 내진성능 특성에 관한 연구)

  • Jo, Min-Joo;Lee, Ju-Na
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.19 no.3
    • /
    • pp.33-40
    • /
    • 2012
  • At present, the problem to secure seismic resistance capacity is one of the most important issue in school buildings. However, the range of facilities to consider retrofit or the proper direction of seismic retrofit haven't provided in details. Therefore in this study, a series of school buildings were chosen as established time, and the structure composition and the seismic performance of the school buildings were investigated to get the comprehensive features of seismic resistance capacity in school buildings. At result, it was presented that the member capacities were less than criteria and structure system was showed the brittle behavior at the collapse prevention level at the school buildings before 1990 year. At the school buildings after 1990 year, though it is hard to get general features for various compositions, it was presented that they have problems for seismic performance evaluation in some buildings at life safety level, specially in the direction of X axis. So, considering the introduction process of seismic criteria in Korea, the school buildings before 2005 year should be examined for seismic resistance capacity and the seismic performance should be examined as well as member capacity to resist seismic.

Probabilistic seismic and fire assessment of an existing reinforced concrete building and retrofit design

  • Miano, Andrea;de Silva, Donatella;Compagnone, Alberto;Chiumiento, Giovanni
    • Structural Engineering and Mechanics
    • /
    • v.74 no.4
    • /
    • pp.481-494
    • /
    • 2020
  • In this paper, a probability-based procedure to evaluate the performance of existing RC structures exposed to seismic and fire actions is presented. The procedure is demonstrated with reference to an existing old school building, located in Italy. The vulnerability assessment of the building highlights deficiencies under both static and seismic loads. Retrofit operations are designed to achieve the seismic safety. The idea of the work consists in assessing the performance of the existing and retrofitted building in terms of both the seismic and fire resistance. The seismic retrofit and fire resistance upgrading follow different paths, depending on the specific configuration of the building. A good seismic retrofit does not entail an improving of the fire resistance and vice versa. The goal of the current work is to study the variation of response due to the uncertainties considered in records/fire curves selection and to carry out the assessment of the studied RC structure by obtaining fragility curves under the effect of different records/temperature. The results show the fragility curves before and after retrofit operations and both in terms of seismic performance and fire resistance performance, measuring the percent improving for the different limit states.

Seismic resistance of dry stone arches under in-plane seismic loading

  • Balic, Ivan;Zivaljic, Nikolina;Smoljanovic, Hrvoje;Trogrlic, Boris
    • Structural Engineering and Mechanics
    • /
    • v.58 no.2
    • /
    • pp.243-257
    • /
    • 2016
  • The aim of this study is to investigate the seismic resistance of dry stone arches under in-plane seismic loading. For that purpose, several numerical analyses were performed using the combined finite-discrete element method (FDEM). Twelve types of arches with different ratios of a rise at the mid-span to the span, different thicknesses of stone blocks and different numbers of stone blocks in the arch were subjected to an incremental dynamic analysis based on excitation from three real horizontal and vertical ground motions. The minimum value of the failure peak ground acceleration that caused the collapse of the arch was adopted as a measure of the seismic resistance. In this study, the collapse mechanisms of each type of stone arch, as well as the influence of the geometry of stone blocks and stone arches on the seismic resistance of structures were observed. The conclusions obtained on the basis of the performed numerical analyses can be used as guidelines for the design of dry stone arches.

A Study on the Seismic Response Analysis of Reinforced Concrete Building (철근콘크리트 건물의 지진응답해석에 관한 연구)

  • 한상훈;이상호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.507-512
    • /
    • 1997
  • The objective of present paper is to provide the fundamental data of earthquake-resistance design such as estimating the resistance capacity and evaluating the design seismic load. With one bending failed building, it is checked and compared between real damaged result and analysis value by means of static and dynamic analysis using multi-degree of freedom system. In this analysis, four kinds of the earthquake waves are used. Through elasto-plastic seismic response analysis of reinforced concrete building, we could estimate dynamic behaviour of building.

  • PDF

Structural Performance of Seismic Resistance Capacity of Carbon Sheet-Angle Retrofitting Method in Wall-Slab Joint (탄소섬유와 L형강을 이용한 벽-슬래브 접합부의 보강성능)

  • Roh Gong-Ki;Park Tae-Won;Park Hyun-Soo;Chung Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.65-68
    • /
    • 2004
  • In the seismical capacity evaluation for RC structure wall-slab joint is very important factor. Because lateral load is resistance element and gravity load resistance element are acted mutually in the wall-slab joint. In this paper, to improve the seismic capacity of the wall-slab joint in the existing wall type apartments experiment which improve and retrofit a seismic capacity by unequal angle bracing and carbon sheet attachment are carried out. These methods are also economic and simple in mitigating seismic hazard, improve earthquake-resistance performance, and reduce risk level of building occupants. From the experimental results, the change of strength, degration of stiffness, and energy dissipation are evaluated. It can be concluded that these methods are effective in improving the seismic performance.

  • PDF

Calculation of Seismic Capacity Evaluation Index of Shear Wall System (전단벽 구조시스템의 내진성능평가 지표 산정)

  • Park, Tae-Won;Na, Seong-Uk;Woo, Woon-Taek;Chung, Lan
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.223-230
    • /
    • 2002
  • Earthquake resistance design has been developed many countries like Japan, USA, Mexico, New Zealand etc., which countries have experienced many earthquakes. Nowadays, earthquake resistance design has come into worldwide use. In Korea, the seismic design regulations have been established since 1988 in order to minimize the economic losses. Recently performance based design method has been adopted as a new Earthquake resistance design method. These regulations, however, are targeted for newly constructed buildings, In Korea, there are no regulations for existing buildings that built before 1988. On the other hand, in Japan and USA, the seismic performance evaluation is coded. In Japan, the evaluation index which can measure seismic performance has been made. So, we need to prepare the regulations that evaluate the seismic performance, furthermore proper retrofitting design guideline needs to be proposed when remodeling old buildings. In this research, various seismic performance evaluation methods which are being used in Japan and USA are reviewed in order to establish seismic performance evaluation index for those existing old structures in Korea.

  • PDF

Effect of Seismic Design Details in Reinforced Concrete Beams on Blast-Resistance Performance (철근콘크리트 보의 내진 설계 상세가 폭발 저항 성능에 미치는 영향)

  • Kim, Kuk-Jae;Kim, Han-Soo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.5
    • /
    • pp.427-434
    • /
    • 2017
  • Recently, awareness of the public about the explosion damage has increased due to the increased risk of terrorism. The criteria for blast-resistance design is not sufficient in Korea, it is necessary to develop blast-resistance design for the stability and safety of building by static analysis of current blast-resistance design. In addition, as the increase of earthquake occurrence necessitates the seismic design, it is studied to judge the blast-resistance performance of members applying seismic design without blast-resistance design. Currently, the general analysis of blast load is to refer to UFC 3-340-02 manual. Blast-resistance performance was studied by applying characteristics of blast load through UFC 3-340-02 manual, beam converted into equivalent SDOF System. It is proved that blast-resistance performance is improved when seismic detail is applied considering the maximum deflection of normal, intermediate, and special moment frames.

A Study on the Seismic Resistance Design of Sway Brace Device using Internet of Things (IoT를 활용한 흔들림 방지 버팀대의 내진설계에 관한 연구)

  • Thak, Sung-In;Yu, Bong-Geun;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.58-62
    • /
    • 2017
  • There is a growing need for seismic resistance design. But it is controversial that standards of sway brace device in non-structural elements for buildings like pump waterway is vary widely. Therefore, in this study to get a valid range of sway brace device in seismic resistance design, using load test of sway brace device. As a result, load of safe range from 0 to 18.5 kN and under 29.4 kN, no structural fault of sway brace device. And using internet of things get a data of seismic resistance design from sensor node like accelerometer, GPS, tilt sensor and temperature sensor through steps of sampling and prediction. These results will be acceptable for monitoring system for seismic resistance in non-structural elements.

Seismic performance of RC frames retrofitted with haunch technique

  • Akbar, Junaid;Ahmad, Naveed;Alam, Bashir;Ashraf, Muhammad
    • Structural Engineering and Mechanics
    • /
    • v.67 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • Shake table tests performed on five 1:3 reduced scale two story RC moment resisting frames having construction defects, have shown severe joint damageability in deficient RC frames, resulting in joint panels' cover spalling and core concrete crushing. Haunch retrofitting technique was adopted herein to upgrade the seismic resistance of the deficient RC frames. Additional four deficient RC frames were built and retrofitted with steel haunch; both axially stiffer and deformable with energy dissipation, fixed to the beam-column connections to reduce shear demand on joint panels. The as-built and retrofitted frames' seismic response parameters are calculated and compared to evaluate the viability of haunch retrofitting technique. The haunch retrofitting technique increased the lateral stiffness and strength of the structure, resulting in the increase of structure's overstrength. The retrofitting increased response modification factor R by 60% to 100%. Further, the input excitation PGA was correlated with the lateral roof displacement to derive structure response curve that have shown significant resistance of retrofitted models against input excitations. The technique can significantly enhance the seismic performance of deficient RC frames, particularly against the frequent and rare earthquake events, hence, promising for seismic risk mitigation.