• Title/Summary/Keyword: seismic performance and design

Search Result 1,416, Processing Time 0.024 seconds

Numerical Verification of the Proposed Design Procedure of MR Damper for Seismic Response Control of Building Structure (건축 구조물의 지진응답 제어를 위해 제안된 MR감쇠기 설계 절차의 수치적 검증)

  • Lee, Sang-Hyun;Min, Kyung-Won;Lee, Roo-Jee
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.521-528
    • /
    • 2005
  • In our previous study, we have developed a preliminary design procedure of MR dampers for controlling seismic response of building structures. In this paper, the effectiveness the proposed method is verified through the numerical analysis of the structures with various period and story number, and twenty earthquake loads are used for statistical assessment. The comparison between the proposed method and simplified sequential search algorithm indicates that the capacity, number and the placement of the MR damper which can achieve the given performance objective are reasonably determined using the proposed design procedure.

  • PDF

An Experimental Study on Seismic Performance Evaluation of Retrofitted Column of FRP Seismic Reinforcement that can be Emergency Construction (긴급시공이 가능한 FRP 내진보강재로 보강된 기둥의 내진성능평가 실험)

  • Kim, Jin-Sup;Kwon, Min-Ho;Seo, Hyun-Su;Lim, Jeong-Hee;Kim, Dong-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.21-30
    • /
    • 2013
  • As increasing number of large-size earthquake, the social interest of seismic retrofitting of RC structure is growing. Especially, the RC columns that are not reflected seismic design can not resist lateral loads by the earthquake. The brittle fracture of Non-seismic designed columns lead to full collapse of the building. Thus, the emergency columns reinforcement method is needed. That have a fast construction time, do not cause damage to the column. In the past, cross-sectional expansion method, a steel plate reinforcing method is applied mainly, but in recent years, carbon fiber sheet taking advantage of FRP (Fiber Reinforced Polymer) is widely used. In this study, retrofitting effect of seismic performance of FRP seismic reinforcement, which is possible to emergency construction, was examined. Reinforced concrete specimens were constructed to experimental study. The seismic performence of specimes retrifitted with FRP seismic reinforcement were evaluated. As a result, the seismic performance of specimen reinforced with FRP seismic reinforcement has been improved.

Seismic Performance Enhancement of Residential Flat Plate Structure by Using Base Isolation Devices. (면진장치를 사용한 주거용 무량판구조의 내진성능 향상)

  • Lee, Hyun Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.185-191
    • /
    • 2007
  • For the seismic performance enhancement of residential flat plate structure and for the selection of earthquake records, the possibility of base isolation is evaluated and the time history results are reviewed. By evaluating a base isolated stiffness, a target period, and an envelope curve analysis, seismic performance of structure, which has strong rotational mode, is evaluated. For the propriety evaluation of earthquake records usage and scaling method, time history analysis is done with variables such as DBE(design base earthquake) level, MCE(maximum considerable earthquake) level, and 1.4DBE level. From the analysis results, following conclusions can be made; the earthquake records, which are used in base isolation analysis, should be selected by similar soil type which the structure is considered, and should be intensity scaled in a range of mean ${\pm}$ standard deviation of code based design response spectrum.

Parametric Analysis of Damping Performance of TLD for Seismic Design of High-Rise Building (고층건물 내진설계용 TLD의 감쇠성능 파라메트릭 해석)

  • Lee, Jae-Hoon;Park, Seong-Woo;Cho, Jin-Rae
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2007.04a
    • /
    • pp.783-788
    • /
    • 2007
  • Many researches have been studied several vibration control device such as TMD and TLD to reduce the influence of wind or seismic waves for high-rise buildings. TLD provides some advantages such as easy installation and low maintenance cost. However, because of the difficulties in evaluating the characteristics of TLD, the dynamic characteristics of TLD must be investigated by experiment or analysis. In this study, the dynamic response analysis of structure with TLD was carried out to verify the vibration control ability of the proposed TLD for high-rise building. The parameter of interest was chosen by the height of the water level and the frequency of input seismic wave in the same shape of water tank.

  • PDF

Weight Drop Impact Tests of Earthquake-Proof Table (내진테이블의 중량물 낙하 충격실험)

  • Eom, Tae Sung;Huh, Seok Jae;Park, Tae Won;Lee, Sang Hyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.7
    • /
    • pp.369-378
    • /
    • 2018
  • Full-scale seismic retrofit of old and deteriorated masonry buildings requires a lot of cost and time. In such buildings, installing an emergency evacuation space can be considered as an alternative. In this study, requirements of the earthquake-proof table used as an emergency evacuation space for buildings hit by earthquake are investigated. Load conditions required for the table, including the impact effects due to building debris drop, are explained. To investigate the impact effects in more detail, weight drop test is performed for an prototype earthquake-proof table. In the test, the weight of the falling object and free fall height were considered as the main test parameters. The results showed that the duration of impact is very short (0.0226~0.0779sec), and thus the impact forces increase to 15.8~45.2 times the weight of the falling object. Based on these results, design considerations and performance verification criteria of the earthquake-proof table as an emergency evacuation space are given.

A Study on Improvement Plans of Earthquake Disaster Safety Management in National Industrial Complexes (국가산업단지 지진재난 안전관리 개선방안 연구)

  • Song, Chang Young;Lee, Dae Jin
    • Journal of Korean Society of Disaster and Security
    • /
    • v.13 no.3
    • /
    • pp.1-14
    • /
    • 2020
  • The purpose of this study is to identify the problems of the earthquake disaster safety management in the national industrial complexes and to suggest improvement counter-measure. Literature review for the safety management system of the Korea Industrial Complex Corporation and interview with practitioners was conducted. and Seismic design application survey was conducted on 28 national industrial complexes. In order to improve Earthquake Disaster Safety Management, Counter-measures were suggested such as the reinforcement of laws and regulations related Seismic. It is expected that the improvement counter-measures presented in this study can be used as policy-making data for improving the seismic performance of the national industrial complexes in the future.

Efficient Panel Shapes for Seismic Resistance of Stainless Steel Water Tank (스테인리스 물탱크 내진설계를 위한 효율적 패널 형상)

  • Kim, Sungwuk;Kim, Taeeun;Oh, Sungryoung;Ji-Hun Park
    • Journal of Urban Science
    • /
    • v.12 no.2
    • /
    • pp.19-30
    • /
    • 2023
  • The seismic design of water tanks for fire protection is important to prevent secondary earthquake damages due to fires. In this study, the seismic performance of stainless steel water tanks was evaluated considering both static and dynamic water pressure effects, and the influence of different panel shapes was investigated through numerical analysis. First, a basic water tank model comprised of flat panels was built, and then water pressure distribution including sloshing effects was evaluated. In the result of structural analysis, many panels of the basic water tank exceeded a specified allowable stress for load combinations including earthquake loads. In order to reduce the bending stress of the panel by increasing the moment of inertial of the panel section, alternative shapes of a truncated quadrangular pyramid were developed. Five water tanks with different alternative panel shapes were built and analyzed for the same load combinations. Based on the results of the numerical analysis, a number of effective aspect ratios were selected and modified to increase economic feasibility through additional analysis and structural safety check.

Earthquake Design Method for Structural Walls Based on Energy Dissipation Capacity (에너지 소산능력을 고려한 전단벽의 내진설계)

  • 박홍근;엄태성
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.6
    • /
    • pp.25-34
    • /
    • 2003
  • Recently, performance-based analysis/design methods such as the capacity spectrum method and the direct displacement-based design method were developed. In these methods, estimation of energy dissipation capacity of RC structures depends on empirical equations which are not sufficiently accurate, On the other hand, in a recent study, a simplified method for evaluating energy dissipation capacity was developed. In the present study, based on the evaluation method, a new seismic design method for flexure-dominated RC walls was developed. In determination of earthquake load, the proposed design method can address variations of energy dissipation capacity with design parameters such as dimensions and shapes of cross-sections, axial force, and reinforcement ratio and arrangement, The proposed design method was compared with the current performance-based design methods. The applicability of the proposed method was discussed.

Ductility and inelastic deformation demands of structures

  • Benazouz, Cheikh;Moussa, Leblouba;Ali, Zerzour
    • Structural Engineering and Mechanics
    • /
    • v.42 no.5
    • /
    • pp.631-644
    • /
    • 2012
  • Current seismic codes require from the seismically designed structures to be capable to withstand inelastic deformation. Many studies dealt with the development of different inelastic spectra with the aim to simplify the evaluation of inelastic deformation and performance of structures. Recently, the concept of inelastic spectra has been adopted in the global scheme of the performance-based seismic design through capacity-spectrum methods. In this paper, the median of the ductility demand ratio for 80 ground motions are presented for different levels of normalized yield strength, defined as the yield strength coefficient divided by the peak ground acceleration (PGA). The influence of the post-to-preyield stiffness ratio on the ductility demand is investigated. For fixed levels of normalized yield strength, the median ductility versus period plots demonstrated that they are independent of the earthquake magnitude and epicentral distance. Determined by regression analysis of the data, two design equations have been developed; one for the ductility demand as function of period, post-to-preyield stiffness ratio, and normalized yield strength, and the other for the inelastic deformation as function of period and peak ground acceleration valid for periods longer than 0.6 seconds. The equations are useful in estimating the ductility and inelastic deformation demands for structures in the preliminary design. It was found that the post-to-preyield stiffness has a negligible effect on the ductility factor if the yield strength coefficient is greater than the PGA of the design ground motion normalized by gravity.

Seismic fragility analysis of a new type of reinforced concrete energy dissipation structure

  • Penghui Yang;Xingwen Liang;Ren Xin;Huajing Zhao
    • Structural Engineering and Mechanics
    • /
    • v.92 no.3
    • /
    • pp.285-295
    • /
    • 2024
  • In order to improve the seismic performance of reinforced concrete (RC) frame structure, high performance fiber reinforced concrete (HPFRC) energy dissipation walls were installed in RC frame to form a new aseismic structure. Two half-scale HPFRC energy dissipation wall-RC frame specimens were designed and constructed. Quasi-static tests were performed to study the failure mechanism, deformation performance, and energy dissipation performance. The test results indicate that HPFRC energy dissipation wall-RC frame structures can achieve the seismic fortification objective of being "repairable after major earthquake". Based on the incremental dynamic analysis (IDA) method, seismic fragility analysis of the HPFRC energy dissipation wall-RC frame structure was performed by using PERFORM-3D structural analysis software and 44 ground motion records. The results show that the HPFRC material has good tensile strain hardening performance, which can improve the damage resistance and energy dissipation capacity of the structure or components. When the structure collapses, the average spectral acceleration response corresponding to the fundamental period of the structure calculated by 44 ground motion records is greater than the spectral acceleration corresponding to the fundamental period of the structure duringa rare earthquake with a fortification intensity of 8 degree, so the HPFRC energy dissipation wall-RC frame structure has good anti-collapse ability. Under the action of a rare earthquake of magnitude 8, the exceeding probability of collapse of the HPFRC energy dissipation wall-RC frame structureis 0.03%, which meets the requirements forseismic protection of the structure under the action of a large earthquake.