• Title/Summary/Keyword: seismic force

Search Result 901, Processing Time 0.024 seconds

Dynamic Behaviour of Bridges with Hysteric Isolator under Seismic Acceleration (이력 감진장치를 설치한 교량의 지진에 의한 동적 거동)

  • Im, Jung-Soon;Jo, Jae-Byung;An, Young-Gi;Lee, Hee-Mok;Hong, Soon-Jin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.3
    • /
    • pp.149-156
    • /
    • 1999
  • Numerical studies were carried out to investigate the mechanical properties of competent hysteric isolators for seismic design of bridge. For dynamic analysis, bridges with isolator were simplified to a model with single degree of freedom. The initial stiffness and the yielding forces of hysteric isolators were varied. Seismic responses obtained by time history analysis show that about 4% of the weight acting as the inertia force is appropriate for the yielding force of isolator. And also better results could be achieved with the values about two times the weight per unit displacement for the initial stiffness of isolator.

  • PDF

A Comparative Study on Displacement-Based Seismic Design Method of Bridge Structures (변위기반설계법에 의한 교량 내진설계의 비교연구)

  • Ju, Jeong-Hun;Cho, Yang-Hee
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.308-315
    • /
    • 2006
  • Most of seismic designs of major structures up to now have been performed by the traditional 'force-based design' approaches. However, they are not so efficient to evaluate the structural deformations by potential nonlinear behaviors which are directly related with the damages or performance levels during earthquakes. Lately, based on this situation, various kinds of new seismic design approaches based on the deformation, which is called 'displacement-based design' procedures, have been proposed. In this paper, most of detail techniques and procedures of the new design methods in the literature are comparatively reviewed and evaluated first, followed by a series of design examples of typical bridge structures. Comparing the results with those of the existing force-based design, the improved levels of performance and economy of the displacement-based seismic design have been validated.

  • PDF

Application of a ductile connection system to steel MRF strengthened with hinged walls

  • Zhi Zhang;Yulong Feng;Dichuan Zhang;Zuanfeng Pan
    • Steel and Composite Structures
    • /
    • v.51 no.5
    • /
    • pp.487-498
    • /
    • 2024
  • Steel moment resisting frames (MRFs) typically have inter-story drift concentrations at lower stories during earthquakes as found from previous research. Hinged walls (HWs) can be used as structural strengthening components to force the MRFs deform uniformly along the building height. However, large moment demands are often observed on HWs and make the design of HWs non-economical. This paper proposes a method to reduce the moment demand on HWs using a ductile connection system between the MRFs and the HWs. The ductile connection system is designed with a yield strength and energy dissipation capacity, for the purpose of limiting the seismic forces transferred to the HWs and dissipating seismic energy. Nonlinear time history analyses were performed using 10 far-filed earthquakes at maximum considered earthquake level. The analysis results show that the proposed ductile connection system can reduce: (1) seismic moment demands in the HWs; (2) floor accelerations; (3) the connection force between HWs and MRFs.

Surrounding rock pressure of shallow-buried bilateral bias tunnels under earthquake

  • Liu, Xin-Rong;Li, Dong-Liang;Wang, Jun-Bao;Wang, Zhen
    • Geomechanics and Engineering
    • /
    • v.9 no.4
    • /
    • pp.427-445
    • /
    • 2015
  • By means of finite element numerical simulation and pseudo-static method, the shallow-buried bilateral bias twin-tube tunnel subject to horizontal and vertical seismic forces are researched. The research includes rupture angles, the failure mode of the tunnel and the distribution of surrounding rock relaxation pressure. And the analytical solution for surrounding rock relaxation pressure is derived. For such tunnels, their surrounding rock has sliding rupture planes that generally follow a "W" shape. The failure area is determined by the rupture angles. Research shows that for shallow-buried bilateral bias twin-tube tunnel under the action of seismic force, the load effect on the tunnel structure shall be studied based on the relaxation pressure induced by surrounding rock failure. The rupture angles between the left tube and the right tube are independent of the surface slope. For tunnels with surrounding rock of Grade IV, V and VI, which is of poor quality, the recommended reinforcement range for the rupture angles is provided when the seismic fortification intensity is VI, VII, VIII and IX respectively. This study is expected to provide theoretical support regarding the ground reinforcement range for the shallow-buried bilateral bias twin-tube tunnel under seismic force.

Control of a building complex with Magneto-Rheological Dampers and Tuned Mass Damper

  • Amini, F.;Doroudi, R.
    • Structural Engineering and Mechanics
    • /
    • v.36 no.2
    • /
    • pp.181-195
    • /
    • 2010
  • Coupled building control is a viable method to protect tall buildings from seismic excitation. In this study, the semi-active control of a building complex is investigated for mitigating seismic responses. The building complex is formed of one main building and one podium structure connected through Magneto-Rheological (MR) Dampers and Tuned Mass Damper. The conventional semi-active control techniques require a primary controller as a reference to determine the desired control force, and modulate the input voltage of the MR damper by comparing the desired control force. The fuzzy logic directly determines the input voltage of an MR damper from the response of the MR damper. The control performance of the proposed fuzzy control technique for the MR damper is evaluated for the control problem of a seismically-excited building complex. In this paper, a building complex that include a 14-story main building and an 8-story podium structure is applied as a numerical example to demonstrate the effectiveness of semi-active control with Magneto-Rheological dampers and its comparison with the passive control with the Tuned Mass Damper and two uncoupled buildings and hybrid semi-active control including the Tuned Mass Damper and Magneto-Rheological dampers while they are subject to the earthquake excitation. The numerical results show that semi-active control and hybrid semi-active control can significantly mitigate the seismic responses of both buildings, such as displacement and shear force responses, and fuzzy control technique can effectively mitigate the seismic response of the building complex.

Dynamic Analysis of Inclined Piles and Countermeasures against their Vulnerability (경사말뚝의 동적거동과 내진성능 향상을 위한 실험적 고찰)

  • 김재홍;황재익;김성렬;김명모
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2001.09a
    • /
    • pp.107-114
    • /
    • 2001
  • When group pile supporting structures are to be subjected to large lateral loads, generally, hatter piles are used in group pile with vertical piles. It is well known that batter piles resist lateral static loads which are acted upon the piles as axial farces quite well but, they show a poor performance under seismic loads. However, it is not yet known how the batter piles behave under dynamic loading and how to strengthen the batter piles to improve the seismic performance. Shaking table tests were performed to investigate the seismic behavior of the batter pile and to bring up the countermeasures to improve the seismic performance. As the result of the shaking table tests, batter piles failed due to not only the excessive increase of compressive force near the pile head but also that of tensile force. In case that the pile head was connected with pile cap by rubber joint, the max. acceleration at the pile cap was reduced due to the high damping ratio of rubber and the max. moment and max. axial farce at the pile head was decreased remarkably. When the inclinations(V:H) of the batter pile were 8:3 and 8:4, max. moment, max. shear force, and max. axial farce were reduced notably and max. acceleration and max. displacement at the pile cap was diminished, too.

  • PDF

The Study on Seismic Analysis Methods for Underground Structures (지중구조물의 내진해석방법에 관한 연구)

  • Jeong, Gwang-Mo;Bang, Myeong-Seok
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2011.11a
    • /
    • pp.75-84
    • /
    • 2011
  • In this paper various numerical analyses are carried out according to behavior characteristics of structures and types of seismic design methods as a study on the seismic analysis for underground structures. Equivalent Static Force Procedure and Response Displacement Method commonly used in practiral design are adopted and Time History Method regarded as the most accurate analysis method is selected to verify the results of two practical methods above. 3-D modelling for seismic analysis of structures is introduced to consider Structure Soil Interaction and all analyses are based on Korea Structural Concrete Design Code. After numerical analyses, Equivalent Static Force Procedure and Response Displacement Method showed relatively lager values than those of Time History Method, so it is identified that above two methods are suitable for practical design purpose.

  • PDF

Seismic behavior of soft storey mid-rise steel frames with randomly distributed masonry infill

  • Quayyum, Shahriar;Alam, M. Shahria;Rteil, Ahmad
    • Steel and Composite Structures
    • /
    • v.14 no.6
    • /
    • pp.523-545
    • /
    • 2013
  • In this study, the effect of presence and distribution of masonry infill walls on the mid-rise steel frame structures having soft ground storey was evaluated by implementing finite element (FE) methods. Masonry infill walls were distributed randomly in the upper storey keeping the ground storey open without any infill walls, thus generating the worst case scenario for seismic events. It was observed from the analysis that there was an increase in the seismic design forces, moments and base shear in presence of randomly distributed masonry infill walls which underlines that these design values need to be amplified when designing a mid-rise soft ground storey steel frame with randomly distributed masonry infill. In addition, it was found that the overstrength related force modification factor increased and the ductility related force modification factor decreased with the increase in the amount of masonry infilled bays and panels. These must be accounted for in the design of mid-rise steel frames. Based on the FE analysis results on two mid-rise steel frames, design equations were proposed for determining the over strength and the ductility related force modification factors. However, it was recommended that these equations to be generalized for other steel frame structure systems based on an extensive analysis.

Seismic Performance of Dual Damper System Using High Damping Rubber and Steel (고감쇠 고무와 강재를 사용한 이중감쇠 제진시스템의 내진성능)

  • Kim, Jung-Uk;Kim, Dong-Keon
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.21 no.1
    • /
    • pp.185-192
    • /
    • 2019
  • Recently, the frequency and magnitude of earthquakes are increasing worldwide. In Korea, the Gyeongju earthquake (2016) and the Pohang earthquake (2017) caused structural damage to many buildings. Since Korea's seismic design standards were revised to three or more stories in 2005, five-story buildings built before the revision are not designed to be earthquake-resistant. In this situation, if strong earthquake occurs in Korea, there will be great damage. To prevent this, seismic retrofit of buildings should be necessary. The seismic retrofit of classical method is mainly used to reduce the displacement generated in the structure by strengthening stiffness and strength. However, since this method increases the base shear force of the structure, it is difficult to apply it to buildings which have weak foundation. Therefore, in this study, we propose the damper system that reduces the response displacement of buildings and suppresses the increase of base shear force by using high damping rubber and steel. And the seismic performance of the damper system is verified through the experiment and the seismic analysis of the structure.

Configurations of the Friction Dampers Installed in a Reinforced Concrete Shear Wall-Moment Frame System (철근콘크리트 전단벽-모멘트골조 형식 건물에 대한 마찰형 감쇠기 설치방식 비교연구)

  • Park, Ji-Hun;Kim, Gil-Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.2
    • /
    • pp.53-67
    • /
    • 2008
  • In this study, seismic control performance of friction dampers installed in a reinforced concrete shear wall-moment frame system, of which main lateral force resisting system is a shear wall, is investigated. Three configurations of friction dampers are investigated. One is a diagonal brace type reinforcing the shear wall directly, another is a diagonal brace type reinforcing the moment frame without the shear wall, and the other one is a vertical boundary element type installed at both ends of the shear wall. In addition, various levels of the total friction force and its distribution methods are examined. Time history analysis considering material nonlinearity is conducted for seismic loads increased by the enhanced design code compared to the initial design loads, and energy dissipation, lateral loads and structural member damages are analyzed. As a result, the shear wall-reinforcing diagonal brace type with the total friction force of 30 % of the reference friction force gives the best performance on the whole, and the distribution methods of the friction force do not have remarkable difference in effects. Also, concentrated installation in adjacent four stories shows just a little compromised control performance compared to the entire story installation.